
Technical
Information
no.
912-100-0123
page
1/8
Heater Mini
Content:
1 Safety advises
2 Device description
3 Function description
4 Operation
5 Installation
6 Technical data
7 Maintenance
8 Spare parts
9 Optional accessories
10 Fault diagnosis
A U R O R A
Konrad G. Schulz GmbH & Co. KG
Tel.: 0 62 84 / 92 02-0
info@aurora-eos.com
www.aurora-eos.com
The information on this document and the copyrights are ownership of
AURORA Konrad G. Schulz GmbH & Co. KG, Joachim Schulz str.4, D-69427 Mudau.
Transmission or duplication of this document or the utilization of the contents is not allowed without the
agreement of AURORA Konrad G. Schulz GmbH & Co. KG otherwise it is explicit allowed. Violation will be
prosecuted. All rights of patents, industrial designs and trademarks are reserved.
Please pay attention to ISO 16016.
We reserve the right to make technical modifications
author: 15.04.1999 KH
date/name
checked: 25.03.15 CK
date/name
released: 25.03.15 i.A.CK
date/name
a) 7726 14.05.01 KH e) 11717 11.07.06 KH i) 20613 11.11.13 KH
b) 8639 19.03.03 KH f) 12014 24.10.06 KH j) 21985 10.03.15 KH
c) 9708 28.06.04 KH g) 16415 05.10.10 KH
d) 11440 18.04.06 KH h) 19358 08.11.12 KH

Technical
Information
no.
912-100-0123
page
2/8
1 Safety advises
Please consider the following advice for your own safety.
• Please have maintenance work and repairs exclusively carried out by authorised personnel.
• Do not grip into the unit and do not put objects inside.
• Maintenance work is to be carried out only when the blower-motor is not running. In order to
avoid injuries, the motor is to be separated from the current circuit.
• Attention! Danger of burning! Please do not get into contact with the heat exchanger and
its connections. Cooling tubes and cooling hoses can be hot and stand under pressure. Be
careful by touching them.
• This also applies for 2-speed versions to the resistor when working at the opened unit and
the construction part has not completely cooled down.
• Attention: cables may not affect the resistor!
• At maintenance work and repairs wear necessary protective clothing.
Advice for installation and maintenance work:
Please pay attention to the rules for the prevention of accidents.
2 Device description
The heater versions differences are the nominal voltage, the air outlets and the heat exchanger
connections.
This technical information is valid for the following versions:
AURORA-part no. nominal
voltage
Air outlets
Heat exchanger connection-∅
151-301/302-0000 12V/24V 2 air grids 120x60 mm
∅12 straight connection
151-301-0001 12V 2 air grids 120x60 mm
∅12 straight connection
151-301/302-0002 12V/24V 2 air grids 120x60 mm
∅12 90° connection
151-301/302-0003 12V/24V 2 air grids 120x60 mm
∅12 90° connection
151-301/302-0004 12V/24V without air grids
∅12 straight connection
151-301/302-0005 12V/24V without air grids
∅12 straight connection
151-301/302-0006 12V/24V without air grids
∅12 90° connection
151-301/302-0007 12V/24V 2 air grids 120x60 mm
∅12 90° connection
151-301/302-0008 12V/24V 2 air grids 120x60 mm
∅15 straight connection
151-302-0009 24V 2 air grids 120x60 mm
∅12 straight connection
151-302-0010 24V 2 air grids 120x60 mm
∅15 straight connection
151-301/302-0011 12V/24V 2 air grids 120x60 mm
∅12 straight connection
151-301-0012 12V air outlet box with 2 oval
sockets
∅12 straight connection
151-301-0013 12V angular air outlet hood
∅12 straight connection
151-301-0014 12V air outlet hood with socket
∅70 mm
∅12 straight connection
151-301-0015 12V air outlet hood with socket
∅70 mm
∅12 straight connection
151-301/302-0016 12V/24V air outlet box with flap and 1
socket ∅70 mm
∅12 straight connection

Technical
Information
no.
912-100-0123
page
3/8
AURORA-part no. nominal
voltage
Air outlets
Heat exchanger connection-∅
151-301-0017 12V air outlet box with flap and 1
socket ∅55 mm
∅12 straight connection
151-301/302-0018 12V/24V air outlet box with flap and 1
socket ∅55 mm
∅12 straight connection
151-301/302-0019 12V/24V air outlet box with flap and 1
socket ∅55 mm
∅12 straight connection
151-301/302-0020 12V/24V air outlet box with flap and 2
sockets ∅42 mm
∅12 straight connection
151-301/302-0021 12V/24V air outlet box with flap and 2
sockets ∅55/∅42
∅12 straight connection
151-301/302-0022 12V/24V air outlet box with flap and 2
sockets ∅42 mm
∅12 straight connection
151-301/302-0023 12V/24V air outlet box with flap and 2
sockets ∅55/∅42
∅12 90° connection
151-301-0024 12V air outlet box with 1 socket
∅42 mm and 1 oval socket
78x55x3
∅12 straight connection
151-301-0025 12V air outlet box with flap and 1
socket 78x55x3mm
∅12 straight connection
151-301-0026 12V air outlet box with flap and 1
socket ∅55 mm
∅12 straight connection
151-301-0027 12V air outlet box with flap and 2
oval sockets
∅12 straight connection
151-301-0028 12V air outlet box with flap and 1
sockets ∅42 mm
∅12 straight connection
151-301/302-0029 12V/24V air outlet box with flap and 1
sockets ∅42 mm
∅12 straight connection
151-301-0030 12V air outlet box with flap and 2
sockets ∅42 mm
∅12 straight connection
151-301-0031 12V air outlet box with 1 socket
∅55 mm
∅15 90° connection
151-301-0032 12V 2 air grids 120x60 mm
∅12 straight connection
151-301-0033 12V 2 air grids 120x60 mm
∅12 90° connection
151-302-0034 24V 2 air grids 120x60 mm
∅12 straight connection
151-302-0035 24V 2 air grids 120x60 mm
∅12 straight connection
151-301/302-0036 12V/24V air outlet box with flap and 2
sockets ∅42 mm
∅12 straight connection
151-301-0037 12V/24V air outlet box with 1 socket
∅80 mm
∅12 straight connection
151-302-0038 24V 2 air grids 120x60 mm
∅12 straight connection
151-301/302-0039 12V/24V 2 air grids 120x60 mm Ø12 90° connection
151-301-0040 12V air outlet hood with round
nozzle RD 85.0
∅15 bent connection
151-302-0041 24V air outlet hood Ø70
∅15 straight connection
151-301/302-0042 12V/24V 2-speed with resistor
∅15 straight connection
151-301-0043 12V air outlet hood Ø70
∅15 bent connection
151-302-0044 24V air outlet hood Ø70
∅15 straight connection
151-301/302-0045 12V/24V 2-speed with resistor
∅15 straight connection
151-301-0046
12V 2-speed with resistor
air outlet hood Ø70
180° rotated from the
suction side
∅12 straight connection
Note: Some versions are no longer available