RC-8
Spacing and Installation :
• Wall Installation: Secure RC-8 horizontally 3” from the bottom
and top of your wall, then approx. every 24” on center (Example:
An 8’ high wall would require (5) 8-foot sections of RC-8 per 8’ of
wall width). RC-8 is installed with the flange on bottom as shown
in the figure 1.
• Ceiling Installation: Secure RC-8 to ceiling joists every 12” on
center if using multiple layers of drywall and/or SheetBlok. Space
every 16” on center if using only a single layer of drywall.
• Floor Installation: DO NOT use RC-8 on floor installations. RC-8
is NOT intended or designed for floor installations. Auralex
recommends using U-Boat Floor Floaters when isolating a floor.
General Notes:
• RC-8 creates a nominal 1/2” spacing between the wall stud or ceiling joist and the drywall.
Resilient Channel
Installation Guidelines
Figure 1
• When mounting two sections of RC-8 to a single wall stud or ceiling joist, overlap the pieces and secure them together with the
same screw. Do not butt the ends of the channel together, see figure 1.
• When mechanically fastening drywall to the RC-8, do not anchor the drywall to the wall stud or ceiling joist. Auralex recommends
securing the drywall at the midpoints between studs and joists to prevent accidental coupling.
• Up to two layers of ⅝” drywall may be hung on RC-8 OR one layer ⅝” drywall, one layer of Auralex SheetBlok™ mass loaded
vinyl barrier and one layer of ½” drywall.
For best sound isolation, Auralex recommends incorporating
the following products into your room construction as shown
in figure 2:
• SheetBlok™ Sound Barrier
™
RC-8
Resilient
Channel
2” Mineral Fiber
Insulation
SheetBlok
™
• Mineral Fiber Insulation
• StopGap™ Acoustical Sealant
• U-Boat™ Floor Floaters
Figure 2
SheetBlok
™
U-Boat Floor Floaters™
4” Mineral Fiber Insulation
1294-415.RC-8 U ser Guid e (05/ 27/2015 - 9:51 A M)
www.Auralex.com | 1-800-959-3343 | AuralexInfo@Auralex.com | Total Sound Control
®