AUO Confidential For STAR Internal Use Only / 2011/12/13
document version 0.1 2
Product Specification
AU OPTRONICS CORPORATION
M240HW01 V8
Record of Revision
Version and Date Page
0.1
2011/03/15
0.2
2011/6/24
12 2D/3D switch voltage define remove
First Version
20,26
Pin1 : 2D/3D switch Pin1 : NC
Old description New Description Remark
www.jxlcd.com
www.jxlcd.com
document version 0.1 3
AUO Confidential For STAR Internal Use Only / 2011/12/13
Product Specification
AU OPTRONICS CORPORATION
M240HW01 V8
1.0 Handling Precautions
1) Since front polarizer is easily damaged, pay attention not to scratch it.
2) Be sure to turn off power supply when inserting or disconnecting from input connector.
3) Wipe off water drop immediately. Long contact with water may cause discoloration or spots.
4) When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth.
5) Since the panel is made of glass, it may break or crack if dropped or bumped on hard surface.
6) Since CMOS LSI is used in this module, take care of static electricity and insure human earth
when handling.
7) Do not open or modify the Module Assembly.
8) Do not press the reflector sheet at the back of the module to any directions.
9) In case if a Module has to be put back into the packing container slot after once it was taken
out from the container, do not press the center of the LED lightbar edge. Instead, press at the
far ends of the LED light bar edge softly. Otherwise the TFT Module may be damaged.
10) At the insertion or removal of the Signal Interface Connector, be sure not to rotate nor tilt the
Interface Connector of the TFT Module.
11) After installation of the TFT Module into an enclosure, do not twist nor bend the TFT Module
even momentary. At designing the enclosure, it should be taken into consideration that no
bending/twisting forces are applied to the TFT Module from outside. Otherwise the TFT
www.jxlcd.com
Module may be damaged.
12) Small amount of materials having no flammability grade is used in the LCD module. The LCD
module should be supplied by power complied with requirements of Limited Power Source
(IEC60950 or UL1950), or be applied exemption.
13) Pls avoid touching COF position while you are doing mechanical design
14) When storing modules as spares for a long time, the following precaution is necessary:
Store them in a dark place. Do not expose the module to sunlight or fluorescent light. Keep
the temperature between 5555℃℃℃℃ and 35
www.jxlcd.com
and 35℃℃℃℃ at normal humidity.
and 35 and 35
AUO Confidential For STAR Internal Use Only / 2011/12/13
at normal humidity.
at normal humidity. at normal humidity.
document version 0.1 4
Product Specification
AU OPTRONICS CORPORATION
2.0 General Description
This specification applies to the24 inch-FHD Color a-Si TFT-LCD Module M240HW01. The
display supports the FHD - 1920(H) x 1080(V) screen format and 16.7M colors (RGB 6-bits +
Hi-FRC data). The light source of this TFT-LCD module is W-LED. All input signals are 4-channel
LVDS interface and this module doesn’t contain a driver for backlight.
2.1 Display Characteristics
The following items are characteristics summary on the table under 25℃ condition:
ITEMS Unit SPECIFICATIONS
Screen Diagonal [mm] 609.7(24.0”)
Active Area [mm] 531.36 (H) x 298.89 (V)
Pixels H x V 1920(x3) x 1080
Pixel Pitch [um] 276.75 (per one triad) ×276.75
Pixel Arrangement R.G.B. Vertical Stripe
Display Mode TN Mode, Normally White
White Luminance ( Center ) [cd/m2]
Contrast Ratio 1000 (Typ.)
Optical Response Time [msec] 5ms (Typ., on/off)
Nominal Input Voltage VDD [Volt] +5.0 V (Typ)
Power Consumption
(VDD line + LED line)
Weight [Grams] 2200 Typ.
Physical Size [mm] 556.0(H)x323.2(V)x14.4(D)
Electrical Interface 4 channel LVDS
Support Color 16.7M colors (RGB 6-bit + Hi_FRC )
Surface Treatment Anti-Glare, 3H
Temperature Range
Operating
Storage (Shipping)
RoHS Compliance RoHS Compliance
TCO Compliance TCO 5.1 Compliance
www.jxlcd.com
www.jxlcd.com
350 cd/m2 (Typ.)
[Watt] PCBA:7.25W
BL : 19.71W
[oC]
[oC]
0 to +50
-20 to +60
M240HW01 V8
AUO Confidential For STAR Internal Use Only / 2011/12/13
document version1.4 5
2.2 Optical Characteristics
Product Specification
AU OPTRONICS CORPORATION
M240HW01 V8
The optical characteristics are measured under stable conditions at 25℃:
Item Unit Conditions Min. Typ. Max. Note
Horizontal (Right)
CR = 10 (Left)
Viewing Angle [degree]
Vertical (Up)
CR = 10 (Down)
Contrast ratio Normal Direction
Raising Time (TrR)
Response Time [msec]
Color / Chromaticity
Coordinates (CIE)
www.jxlcd.com
www.jxlcd.com
Color Coordinates (CIE) White
Central Luminance [cd/m2] 300 350 - 6
Luminance Uniformity
Crosstalk (in 60Hz)
Flicker
[%]
[%]
dB
Falling Time (TrF)
Raising + Falling
Red x
Red y
Green x
Green y
Blue x
Blue y
White x
White y
75
75
70
70
600
0.620 0.650 0.680
0.299 0.329 0.359
0.301 0.331 0.361
0.592 0.622 0.652
0.121 0.151 0.181
0.023 0.053 0.083
0.283 0.313 0.343
0.299 0.329 0.359
75 80
85
85
80
80
1000 -
-
-
-
3.5 7.4
1.5 2.6
5 10
-
-
-
-
-
1.5 8
-20
2
3
4
5
7
9
AUO Confidential For STAR Internal Use Only / 2011/12/13
document version1.4 6
Center of the screen
Note 1: Measurement method
Product Specification
AU OPTRONICS CORPORATION
M240HW01 V8
The LCD module should be stabilized at given temperature for 30 minutes to avoid abrupt
temperature change during measuring (at surface 35
measurement should be executed after lighting Backlight for 30 minutes in a stable, windless and
dark room.
)
. In order to stabilize the luminance, the
Photo detector
Measured distance
www.jxlcd.com
Note 2: Definition of viewing angle measured by ELDIM (EZContrast 88)
Viewing angle is the measurement of contrast ratio ≧10, at the screen center, over a 180°
horizontal and 180° vertical range (off-normal viewing angles). The 180° viewing angle range is
broken down as follows; 90° (θ) horizontal left and right and 90° (Φ) vertical, high (up) and low
(down). The measurement direction is typically perpendicular to the display surface with the screen
rotated about its center to develop the desired measurement viewing angle.
www.jxlcd.com
document version1.4 7
AUO Confidential For STAR Internal Use Only / 2011/12/13
Product Specification
100
90
10
0
response
T
100
10
0
response
1 Frame
1 Frame
T
AU OPTRONICS CORPORATION
M240HW01 V8
Note 3: Contrast ratio is measured by TOPCON SR-3
Note 4: Definition of Response time measured by Westar TRD-100A
The output signals of photo detector are measured when the input signals are changed from “Full
Black” to “Full White” (rising time, TrR), and from “Full White” to “Full Black” (falling time, TrF),
respectively. The response time is interval between the 10% and 90% (1 frame at 60 Hz) of
amplitudes.
%
Optical
Optical
%
White
rF
Black
Black
rR
White
TrR + TrF =5 msec (typ.).
Note 5: Color chromaticity and coordinates (CIE) is measured by TOPCON SR-3
Note 6: Central luminance is measured by TOPCON SR-3
www.jxlcd.com
www.jxlcd.com
Note 7: Luminance uniformity of these 9 points is defined as below and measured by
TOPCON SR-3
AUO Confidential For STAR Internal Use Only / 2011/12/13
Uniformity =
document version1.4 8
9)-(1 points 9in LuminanceMinimum
9)-(1 Points 9in LuminanceMaximum
Product Specification
Level
DC
AU OPTRONICS CORPORATION
Note 8:Crosstalk is defined as below and measured by TOPCON SR-3
CT = | YB – YA | / YA × 100 (%)
Where
YA = Luminance of measured location without gray level 0 pattern (cd/m2)
YB = Luminance of measured location with gray level 0 pattern (cd/m2)
M240HW01 V8
Note 9: Test Patern: Subchecker Pattern measured by TOPCON SR-3
G B R G B
R
R G B R G B
www.jxlcd.com
R G B R G B
Method: Record dBV & DC value with TRD-100
Amplitude
www.jxlcd.com
DC
Gray Level = L127
Gray Level = L0
log20(dB)Flicker =
AC
Time
Hz) 30Level(at AC
AUO Confidential For STAR Internal Use Only / 2011/12/13
document version1.4 9
Backlight
DC
Connector
LVD
S
Y
-
Driver IC
Connector
3.0 Functional Block Diagram
Product Specification
AU OPTRONICS CORPORATION
M240HW01 V8
The following diagram shows the functional block of the
+5V
LVDS
Receiver
DC/DC
Converter
AUO
ASIC
Timing
Controller
miniLVDS
Transmitter
Gamma
Correction
24.0 inch Color TFT-LCD Module:
G1
TFT-LCD
1920(x3) x 1080
Pixels
G1080
D1
D5760
LED
www.jxlcd.com
www.jxlcd.com
I/F PCB Interface:
185132-15021/P-two
Mating Type:
12507HS-15L/Yeon Ho
I/F + X-PCB
LED Driver on system
AUO Confidential For STAR Internal Use Only / 2011/12/13
document version1.4 10