2. Absolute Maximum Ratings
The following are maximum values which, if exceeded, may cause faulty operation or
damage to the unit.
ParameterSymbolMin.Max.UnitNote
Logic/LCD Driving Voltage V
Input Voltage of SignalVin-0.34
BLU Input Voltage V
BLU Control VoltageBL
Operating Temperature T
Storage Temperature H
Operating Ambient Humidity H
Storage Humidity H
www.panelook.com
DD
DDB
ON
OP
ST
OP
ST
-0.314
-0.327
-0.37.0
050
-2060
1090
1090
V.1
V.1
V1
V1
2
2
%RH2
%RH2
Note 1 : Duration = 50msec
Note 2 : Maximum Wet-Bulb should be 39 and No condensation.
The relative humidity must not exceed 90% non-condensing at temperatures of 40 or less. At
temperatures greater than 40, the wet bulb temperature must not exceed 39 .
PDF created with FinePrint pdfFactory Pro trial version www.pdffactory.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
s
µ
3. Electrical Specification
3-1 Electrical Characteristics
The T370XW02 V0 requires two power inputs. One is employed to power the LCD electronics and to
drive the TFT array and liquid crystal. The second input which powers the CCFL, is typically generated by
an inverter.
www.panelook.com
ParameterSymbol
Min.Typ.Max.
LCD
Power Supply Input Voltage V
Power Supply Input Current I
Power Consumption P
Inrush Current I
Backlight Power Consumption-(120)(132)W
Lamp Life Time50000(60,000)hr3
Note :
1.Vcc=12.0V,
2.Duration = 400
3.The performance of the Lamp in LCM, for example life time or brightness, is extremely influenced by
the characteristics of the DC-AC Inverter. So all the parameters of an inverter should be carefully
designed so as not to produce too much leakage current from high-voltage output of the inverter. When
you design or order the inverter, please make sure unwanted lighting caused by the mismatch of the
=vf60Hz, fCLK=81.5Mhz , 25, Test pattern : white pattern.
LCD
LCD
C
RUSH
(10.8)12.0(13.2)V.
-(0.55)(0.66)A.1
-(6.6)(7.92)W1
--TbdA2
Value
UnitNote
lamp and the inverter (no lighting, flicker, etc) never occurs. When you confirm it, the LCD Assembly
should be operated in the same condition as installed in your instrument.
4.Do not attach a conducting tape to lamp connecting wire. If the lamp wire attach to conducting tape,
TFT-LCD Module have a low luminance and the inverter has abnormal action because leakage current
occurs between lamp wire and conducting tape.
5.The relative humidity must not exceed 80% non-condensing at temperatures of 40 or less. At
temperatures greater than 40, the wet bulb temperature must not exceed 39. When operate at low
temperatures, the brightness of CCFL will drop and the life time of CCFL will be reduced.