NEVER ATTEMPT TO CHARGE ALKALINE OR DRY CELL BATTERIES, AS
BATTERIES MAY BURST CAUSING PERSONAL INJURY AND DAMAGE
TO THE PRODUCT. WHEN RECHARGING NICKEL METAL HYDRIDE
(NiMH) BATTERIES WITH THE SUPPLIED AUDIOVOX CHARGER AND
WALL ADAPTER, USE ONLY AUDIOVOX-APPROVED RECHARGEABLE
BATTERIES. USE OF THE AUDIOVOX CHARGER WITH OTHER BRANDS
OF BATTERIES IS NOT RECOMMENDED, AS BATTERY CHARGING TIMES
WILL VARY WITH DIFFERENT BRANDS. REFER TO THE
MANUFACTURER’S INSTRUCTIONS FOR CHARGING OTHER BRANDS
OF BATTERIES.
AVOID PLACING THE GMRS-3000PK RADIO TRANSCEIVER FOR PROLONGED PERIODS OF TIME IN DIRECT SUNLIGHT OR TEMPERATURES
BELOW -4° F (-20° C) OR ABOVE 140 ° F (60° C).
KEEP THE ANTENNA AT 1 INCH (2.5 cm) AWAY FROM YOUR HEAD AND
BODY. DO NOT USE YOUR GMRS-3000PK RADIO TRANSCEIVER WITH
A DAMAGED ANTENNA.
PLACE THE RUBBER COVERS ON JACKS WHEN NOT IN USE.
GMRS LICENSE:
USE OF THIS RADIO WITHIN THE UNITED STATES REQUIRES AN FCC
GMRS LICENSE. AN INDIVIDUAL 18 YEARS OF AGE OR OLDER, WHO IS
NOT A REPRESENTATAIVE OF A FOREIGN GOVERNMENT, IS ELIGIBLE
TO APPLY FOR A GMRS SYSTEM LICENSE. YOU WILL NEED TWO FORMS
FROM THE FCC; FCC FORM 159 AND FCC FORM 605 MAIN FORM AND
SCHEDULE F. YOU CAN FIND THE FORMS ONLINE AT:
HTTP://WWW.FCC.GOV/FORMPAGE.HTML, OR CALL 1-800-418-3676.
COMPLIANCE:
This transceiver complies with FCC regulations for use in the United
States of America. Use in other countries may be prohibited or restricted
by local regulation. Please check with the local regulating agency before using this device outside the United States of America.
2
128-6476
2 of 28
GMRS-3000PK Handset and Base Station Transceivers
The handset transceiver, when equipped with NiMH rechargable batteries,
can be recharged when placed in the fixed base station transceiver cradle,
which also acts as a desk-top charger.
BASE STATION
RETRACTABLE
ANTENNA
HANDSET
RECHARGABLE
TRANSCEIVER
HANDSET
TRANSCEIVER
ANTENNA
FIXED BASE
STATION
TRANSCEIVER
WALL ADAPTER
OUTPUT PLUG
(9 VDC)
BASE STATION
INPUT JACK
(DC 9V)
AC WALL ADAPTER
120 VAC TO 9 VDC
(P/N F30ADP)
3
128-6476
3 of 28
GMRS-3000PK Handset Controls and Indicators
5
6
5
(REF)
4
3
16
15
2
14
13
1
1. Battery Door
2. Monitor/Backlight Button
3. Detachable Carry Clip
4. Push-To-Talk (PTT) Button
5. Antenna
6. External Speaker(SPK)/Micro-
phone (MIC) Jacks
7. Liquid Crystal Display (LCD)
8. Combination Transmit Indi-
cator (Red)/Receive and Monitor Indicator (Green)
7
8
9
10
11
12
17
9. SCAN/Lock Button
10. Up Channel/Volume Button
11. Emergency (EMG) Call Button
12. Built-in Microphone
13. Built-in Speaker
14. Down Channel/Volume
Button
15. Power On/Off Control
16. MODE Button
17. Battery Charging Contacts
4
3
(REF)
1
(REF)
128-6476
4 of 28
GMRS-3000PK Base Unit Controls and Indicators
6
5
+
DC 9V
4
3
2
1
1. Handset Battery Charge
Contacts
2. Built-in Speaker
3. Up/Down Channel/Volume
Buttons
4. MODE Button
5. Antenna
6. Combination Transmit Indicator
(Red)/Receive and Monitor Indica
tor (Green)/Backlighting (Red/
Green)
7. DC 9V Charger Input Jack
8. Liquid Crystal Display (LCD)
7
8
9
10
11
16
12
13
14
17
15
9. Battery Charge LED (Red)
10.
Power On/Off and Function
Set Button
11. SCAN/Lock Button
12. Emergency (EMG) and
Monitor (M)/Backlight Button
13. Handset Battery CHG Button
14. Push-To-Talk (PTT) Button
15. Built-in Microphone
16. External Microphone (MIC)
Jack
17. External Headset/Speaker
(SPK) Jack
5
128-6476
5 of 28
GMRS-3000PK Handset and Base Station Displays
1
2
3
4
5
6
7
8
1. Beep Tone Indicator: Icon appears when beep confirmation tone is
selected; icon disappears when tone is off.
2. Monitor Indicator: Icon appears when the Monitor (M) button is
pressed and the channel monitor function is activated.
3. Key Lock Indicator: Icon appears when the keypad is locked. This
function disables keys such as channel up/down and MODE.
4. Signal Strength Indicator: Icon appears when a signal is being
received. The icon consists of five bars to indicate the received signal
level.
5. Continuous Tone Coded Squelch System (CTCSS) Indicator:
Indicator appears when the CTCSS tone function is active.
6. Large Segment Display: Indicates the GMRS/FRS channel number
in use.
7. Scan Indicator: This indicator appears when the scan function is
active to scan a channel every 0.5 second.
8. Dual Watch Mode Indicator: Indicator appears when dual watch mode
is active.
9. RogerBeep Tone On/Off Indicator: This icon appears when the
Roger Beep tone is on, and disappears when tone is not in use.
6
9
10
11
12
13
14
15
16
17
128-6476
6 of 28
10. Battery Level Indicator: Icon indicates the battery charge level.
11. Emergency (EMG) Indicator: EMG icon appears when the EMG/M
button pressed. (The emergency frequency is not monitored by
authorities.)
12. Weather Mode Indicator (Base Station Only): This icon appears
steady on the Base Station display when the weather mode is active;
it flashes when weather alert is active in the GMRS mode.
13.Power HI/LO Indicators: Appropriate icon appears when the transmit
power is set to desired output power on the GMRS channels only.
14.Caller Identification (ID) Indicator: This indication appears when
you select a caller identification code (between 1 and 10). ID selection
operates in conjunction with the small segment display, and can also
be used to identify a calling party in the monitor mode.
15.Small Segment Display: Displays the CTCSS tone option in the
channel from (01-38).
16.Out of Range Indicator: Icon flashes when signal strength becomes
weak and intermittant.
17. Voice Activated Transmission (VOX) Indicator: The indicator appears
when the VOX mode is activated.
7
128-6476
7 of 28
Powering the Transceivers:
Your GMRS-3000PK handset transceiver operates on four AAA batteries.
Alkaline batteries will provide slightly better performance than the supplied
rechargeable batteries. Only Audiovox approved rechargeable batteries
can be recharged in the handset transceiver using the Base Station
charging feature and the Wall Charging Adapter supplied with the unit.
This will ensure optimum performance for the GMRS-3000PK. Use of the
Base Unit charging feature with other brands of batteries is not
recommended as battery charging times will vary. Refer to the
manufacturer’s instructions for charging other brands of batteries.
Equipment and Accessories Supplied
1.Radio Transceivers (2)GMRS-3000PK (Handset and
Fixed Base Station)
2.Owner’s Manual (1)128-6476
3.Batteries (4)Rechargeable NiMH (P/N
F30BATT)
4.AC Wall Adapter(P/N F30ADP)
Batteries
There are three methods of powering the GMRS-3000PK Handset Transceiver:
1. Alkaline Batteries.
WARNING: Do not attempt to recharge Alkaline batteries. Also, make
sure to turn off the charger feature of the base station
when rechargeable batteries are not being used.
batteries, Base Station Transceiver, and Wall Charging Adapter
included as part of the GMRS-3000PK). Use only Audiovox approved
rechargeable batteries and Base Station charger when charging
batteries internal to the Handset Transceiver.
8
128-6476
8 of 28
3. Various Brands of Rechargeable Batteries - Use of the Base
Station charging feature with other brands of rechargeable batteries
is not recommended, as battery charging times will vary with different brands of batteries. Refer to the manufacturer’s instructions for
charging other brands of batteries.
The battery charge indicator icon displays the battery charge level in the
handset transceiver. When the AC adapter is connected to the base station
transceiver, it’s indicator icon will always indicate a full charge when the
base station is powered on. A full charge of batteries in the handset
transceiver is indicated by the battery icon as shown below:
Full Battery - three segments are illuminated.
Low Battery - one segment is illuminated.
Approximately 10-12 hours are required to fully charge the batteries in the
handset transceiver. The red H LED charging indicator (9) on the base
station transceiver will light whenever the batteries are charging. If the
charging indicator flashes on/off momentarily when the CHG button is
pressed to on, it is likely no batteries are installed in the handset unit. You
must set the CHG button off when using any batteries other than the ones
provided for the handset transceiver. Failure to do this may cause damage
to the batteries resulting in personal injury and/or damage to either, or
both, transceivers.
Caution: The charging adapter is intended for use with the supplied
rechargeable NiMH batteries, Part Number F30BATT. Do not
attempt to recharge any other type batteries.
Installing the Batteries in the Mobile Transceiver
Battery installation in the Mobile Transceiver is made more convenient
when the carry clip is removed. To do this, release the spring latch securing
the clip to radio and slide the clip downward and away from the radio body.
9
128-6476
9 of 28
Loading...