Audio Technica unipoint U857R, unipoint U857RL Specifications

Frequency Response
Frequency in Hertz
LEGEND
12" or more on axis Roll-off
Response in dB
U857R/U857RL
Polar Pattern
SCALE IS 5 DECIBELS PER DIVISION
8 kHz
LEGEND
200 Hz
1 kHz 5 kHz
CARDIOID CONDENSER ADAPTER-MOUNT GOOSENECK MICROPHONES
• Designed for high-quality sound reinforcement, professional recording and broadcasting
• Super
ior off-axis rejection for maximum gain before feedback
RFI-shielding technology offers outstanding rejection of radio frequency interference (RFI)
• Easy-to-adjust, rugged, small-diameter, alternating gooseneck with virtually no “memory” permits quick positioning into desired shape
• UniSteep
®
filter provides a steep low-frequency attenuation to improve sound pickup without affecting voice quality
• Accepts interchangeab
le elements to permit angle of acceptance from 90° to 360°
• Two-stage foam windscreen yields dramatically improved resistance to P-pops and other breath b
• Direct mounts to any
5
/8"-27 stand, or to included threaded
lasts
mounting flange
The U857R stands 12.01" (305.0 mm) from the table or podium; it is also available in a 16.58" (421.0 mm) version as U857RL. The two models are identical in all other respects.
The U857R requires 11V to 52V phantom power for operation.
Output from the power module’s XLRM-type connector is low impedance (Lo-Z) balanced. The signal appears across Pins 2 and 3; Pin 1 is ground (shield). Output phase is “Pin 2 hot” – positive acoustic pressure produces positive voltage at Pin 2.
An integral 80 Hz high-pass UniSteep
®
filter provides easy switching from a flat frequency response to a low-end roll-off. The roll-off position reduces the microphone’s sensitivity to popping in close vocal use. It also reduces the pickup of low-frequency ambient noise (such as traffic, air-handling systems, etc.), room reverberation and mechanically coupled vibrations.
R/U857RL SPECIFICATIONS
U857 ELEMENT Fix
ed-charge back plate
manently polarized
per condenser
POLAR P FREQ LO
ATTERN
UENCY RESPONSE
W FREQUENCY ROLL-OFF
Cardioid 30-20,000 Hz 80 Hz, 18 dB/octa
ve
OPEN CIRCUIT SENSITIVITY –39 dB (11.2 mV) re 1V at 1 P IMPEDANCE 250 ohms MAXIMUM INPUT SOUND LEVEL 139 dB SPL, 1 kHz at 1%
YNAMIC RANGE
D SIGNAL-T
O-NOISE RATIO
(typical)
1
115 dB, 1 kHz at Max SPL
, 1 kHz at 1 Pa*
70 dB
T.H.D.
PHANTOM POWER 11-52V DC, 2 mA typical REQUIREMENTS
SWITCH Flat, roll-off WEIGHT
U857R
4.4 oz (124 g)
U857RL 4.6 oz (131 g) POWER MODULE 2.9 oz (81 g)
DIMENSIONS
U857R
12.01" (305.0 mm) long
U857RL 16.58" (421.0 mm) long
TH
BO
WER MODULE
PO
0.48" (12.2 mm) head diameter
3.66" (92.9 mm) long,
0.74" (18.9 mm) diameter
OUTPUT CONNECTOR Integral 3-pin XLRM-type (power module)
CABLE 9.8' (3.0 m) long (per
manently attached to microphone), 0.13" (3.2 mm) diameter
, 2-conductor, shielded cable with TA3F-type connector
OPTIONAL INTERCHANGEABLE UE-H hypercardioid (100°); ELEMENTS UE-O omnidirectional (360
UE-UL UniLine™(90
CCESSORIES FURNISHED
A
T8538 power module;
A
T8663 A-mount flange;
A
°);
°)
AT8664 A-mount cable pass­through adapter; AT8153 two­stage foam windscreen
In the interest of standards development, A.T.U.S. offers full details on its test methods to other industr
*1 Pascal = 10 dynes/cm
1
Typical, A-weighted, using Audio Precision System One.
Specifications are subject to change without notice
y professionals on request.
2
= 10 microbars = 94 dB SPL
.
a*
The U857R features a 9.8' (3.0 m) permanently attached miniature cable. It connects to the provided AT8538 power module via a special
TA3F-type connector designed to optimize RFI immunity. Cable exit is from the bottom of the microphone.The included pass­through adapter, designed for use with desk stands and microphone stands, provides a side-exit for the cable.
Avoid leaving the microphone in the open sun or in areas where temperatures exceed 110° F (43° C) for extended periods. Extremely high humidity should also be avoided.
NOTE: Audio-Technica has developed a special RFI-shielding mechanism, which is an integral part of the connectors in the UniPoint line. If you remove or replace the connector, you may adversely affect the unit's RFI immunity.
Audio-Technica U.S., Inc., 1221 Commerce Drive, Stow, Ohio 44224
Audio-Technica Limited, Old Lane, Leeds LS11 8AG England
www.audio-technica.com
P51689 ©2005 Audio-Technica U.S., Inc. Printed in U.S.A.