Audio-Technica U855QL Datasheet

U855QL
12" or more on axis
LEGEND
Frequency in Hertz
Response in dB
10 dB
100
50
200
10k
5k
1k
500
2k
20k
Cardioid Dynamic Gooseneck Microphone
unipoint® microphones
Architect’s and Engineer’s Specications
The microphone shall be a moving coil dynamic. It shall have a cardioid polar pattern and a frequency response of 150 Hz to 16,000 Hz. Nominal open-circuit output voltage shall be 2.2 mV at 1V, 1 Pascal. Output shall be low impedance balanced (600 ohms).
The microphone shall have an XLRM-type connector at the base for direct connection to a mating XLRF-type panel jack or cable connector.
The microphone shall be an adjustable gooseneck design, with an overall length of 448.0 mm (17.64") and a head diameter of 30.0 mm (1.18"). Weight shall be 278 grams (9.8 oz). Finish shall be low-reectance black.
Features
• Designed for use as a high-quality talk-back, paging & dispatch microphone in entertainment, commercial and industrial applications
• Quick-mount design with 3-pin XLRM-type connector insert at base plugs into any standard XLRF-type surface or cable connector
• Low-prole element provides uniform cardioid polar pattern with 120º acceptance angle
• Easy-to-adjust, rugged gooseneck permits quick positioning
• Frequency response tailored for excellent intelligibility in environments with excessive ambient noise
• Cardioid polar pattern reduces pickup of sounds from the sides and rear, improving isolation of desired sound source
• Protective screen reduces wind noise and “popping” when used in close talking situations
U855QL Description
The U855QL is a moving coil dynamic microphone with a cardioid polar pattern. It is designed for use as an extremely durable, high-quality talk-back, paging and dispatch microphone in entertainment, commercial and industrial applications.
The versatile gooseneck design allows for exible positioning and dependable performance. Its custom-tailored frequency response ensures excellent intelligibility in environments with excessive ambient noise. The U855QL stands 448 mm (17.64") from the table or podium.
An XLRM-type connector insert at the base allows the microphone to be plugged directly into an XLRF-type panel jack or microphone cable.
The microphone is enclosed in a rugged housing with a low-reectance black nish.
Specications
Element
Polar pattern
Frequency response
Open circuit sensitivity
Impedance
Weight
Dimensions
Dynamic Cardioid 150-16,000 Hz –53 dB (2.2 mV) re 1V at 1 Pa 600 ohms 278 g (9.8 oz)
448.0 mm (17.64") long,
30.0 mm (1.18") head diameter,
19.0 mm (0.75") base diameter
Output connector
Audio-Technica case style
In the inter est of standards devel opment, A.T.U.S.
offers full details on its test me thods to other industr y
1 Pascal = 1 0 dynes/cm
Specication s are subject to chang e without notice.
professional s on request.
2
= 10 microb ars = 94 dB SPL
frequency response: 150–16,000 Hz polar pattern
200
100
12" or more on axis
500
1k
Frequency in Hertz
5k
2k
10k
50
LEGEND
Integral 3-pin XLRM-type S8
10 dB
Response in dB
20k
330˚
300˚
270˚
240˚
210˚
180˚
SCALE IS 5 DECIBELS PER DIVISION
30˚
60˚
90˚
120˚
LEGEND
200 Hz
150˚
1 kHz 5 kHz 8 kHz
Installation and Operation
Output is low impedance (Lo-Z) balanced. The signal appears across Pins 2 and 3; Pin 1 is ground (shield). Output phase is “Pin 2 hot”— positive acoustic pressure produces positive voltage at Pin 2.
Take care to keep foreign particles from entering the windscreen. An accumulation of iron or steel lings on the diaphragm, and/or foreign material in the windscreen’s mesh surface, can degrade performance.
Audio-Technica U.S., Inc., 1221 Commerce Drive, Stow, Ohio 44224 Audio-Technica Limited, Old Lane, Leeds LS11 8AG England ©2010 Audio-Technica U.S., Inc. audio-technica.com 0001-0272-00