Audio Technica SpectraPulse drm141, SpectraPulse aci707, SpectraPulse mtu101, SpectraPulse cei007 Setup And Operation

SpectraPulse
Ultra Wideband Wireless Microphone System
drm141 Digital Receiver Module aci707 Audio Control Interface mtu101 Microphone Transmitter Unit cei007 Charging/Encryption Interface
2
This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference.
This device complies with INDUSTRY CANADA R.S.S. 210, en conformité avec IC: RSS-210/ CNR210.
Operation is subject to the following conditions: 1) This device may not cause harmful interference and 2) this device must accept any interference
received, including interference which may cause undesired operation. Changes or modifications not expressly approved by Audio-Technica could
void your authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is unlikely to cause harmful interference. However, if the equipment does cause harmful interference, the user
will be required to correct the interference at own expense.
CAUTION! Electrical shock can result from removal of SpectraPulse™components' covers. Refer servicing to qualified service personnel.
No user-serviceable parts inside. Do not expose to rain or moisture.
The circuits inside the SpectraPulse™components have been precisely adjusted for optimum performance and compliance with federal
regulations. Do not attempt to open the drm141 Digital Receiver Module (main assembly), aci707 Audio Control Interface, mtu101 Boundary
Microphone Transmitter or cei007 Charger Encryption Interface. To do so will void the warranty, and may cause improper operation.
Notice to individuals with implanted cardiac pacemakers or AICD devices:
Any source of RF (radio frequency) energy may interfere with normal functioning of the implanted device. All wireless microphones have low-
power transmitters (less than 0.05 watts output) which are unlikely to cause difficulty, especially if they are at least a few inches away. Note
also that any medical-device disruption will cease when the RF transmitting source is turned off. Please contact your physician or
medical-device provider if you have any questions, or experience any problems with the use of this or any other RF equipment.
Please note that your SpectraPulse™system operates in a frequency band in a way which may make its use subject to certain FCC and other
regulatory agency restrictions and licensing requirements. No changes or modifications may be made to this equipment except by the
expressly approved responsible party for compliance. Changes or modifications could void the user's authority to operate the equipment, and
will also void Audio-Technica warranty coverage. For further information, Please contact your local office of the FCC as applicable.
Battery precautions
• Each mtu101 Boundary Microphone Transmitter is powered by 2 AA batteries; alkaline batteries are included,
but rechargeable SANYO brand 2700 mAH NiMH AA batteries are recommended.
• Each cei007 Charging/Encryption Interface includes 14 rechargeable SANYO brand NiMH AA batteries.
Note: Other models of NiMH batteries may work, but the cei007 and the mtu101 are optimized for use with SANYO 2700 mAH NiMH
AA batteries.
• SpectraPulse™cei007 Charging/Encryption Interface is intended only for use of mtu101 Boundary Microphone Transmitters equipped with
rechargeable AA Nickel Metal Hydride (NiMH) batteries. Do not use the charging station for products other than the Audio-Technica
SpectraPulse™system. WARNING: Do not use the cei007 Charging/Encryption Interface to charge batteries of other types besides
NiMH or damage may result.
• Rechargeable batteries must be charged before initial use or after prolonged non-use.
• When recharging, follow instructions in this manual.
• When inserting batteries into the mtu101, observe correct polarity as marked.
• Do not use a leaking battery. If battery leakage occurs, avoid contact with skin. If contact occurs, immediately wash thoroughly with soap
and water. If battery leakage comes into contact with your eyes, immediately flush with water and seek medical attention.
• Do not expose the batteries to fire. Do not heat, deform, solder, disassemble or modify the batteries.
• Do not peel off or damage the outer tube of a battery.
• Do not use these batteries together with dry cells, other types of batteries, new and old batteries together, or batteries with different
charge levels.
Note: This SpectraPulse™system is approved for indoor use only.
3
Contents
SpectraPulse System Features 3
SpectraPulse UWB Wireless Microphone System Components 4
SpectraPulse System Installation & Operation 5
drm141 Digital Receiver Module 5
aci707 Audio Control Interface 5
mtu101 Boundary Microphone Transmitter Unit 6
cei007 Charging/Encryption Interface 7
drm141 Digital Receiver Module Controls and Functions 8
aci707 Audio Control Interface Front Panel Controls and Functions 10
aci707 Audio Control Interface Rear Panel Controls and Functions 11
mtu101 Boundary Microphone Transmitter Controls and Functions 13
cei007 Charging/Encryption Interface Controls 14
Specifications 15
System Features
• Ultra Wideband (UWB) wireless operation
Delivers clear, intelligible audio without the performance and set-up issues associated with conventional RF wireless microphone systems.
• Easy to set up and operate
Designed for quick, intuitive setup and user-friendly operation.
• Interference-free performance
Very few RF devices are approved to operate in the frequencies where the SpectraPulse™UWB wireless microphone system operates.
• No problems in crowded RF environments
Bypasses the increasingly congested UHF, VHF and 2.4GHz frequency bands; ideal for use in areas with high RF congestion.
• No frequency hunting or coordination
14 simultaneous channels operate with no frequency coordination required. Channel selection is quick and easy.
• Immunity to multipath interference
Offers extremely reliable performance; no dropouts or sputters.
• Inherent security
UWB data is transmitted in extremely short-duration pulses sent in a timed sequence over a wide frequency spectrum. To decode the pulses, the Digital Receiver Module must know exactly when, where and how to listen. This makes SpectraPulse inherently secure.
• Encryption available
Optional encryption package meets NIST-approved AES 128-bit encryption standard developed by the U.S. government for securing sensitive material.
• Contact closure input/output (on Audio Control Interface) Provides control interface with external devices.
• Flexible performance
Soft-touch button on boundary microphone/transmitter is configurable for push-to-talk, push-to-mute, and toggle operation.
• Minimal Rack Space Required
7 channels in 1 rack space, 14 channels in 2 rack spaces.
• Optional rechargeable batteries and charging/encryption station
Extended mAH rechargeable AA NiMH batteries (preferred for best battery life performance) are included with optional cei007Charging/Encryption Interface.
• Excellent audio quality
Digital signal requires no compression; imperceptible latency; microphone muting is silent.
• Universal interface
Connects with teleconference systems, videoconference systems, PA/local sound systems, archive recording and logging systems.
4
SpectraPulse™Components
and Included Accessories
The SpectraPulse™UWB wireless microphone system consists of four components: the drm141 Digital Receiver Module, designed for ceiling­or wall-mount; the aci707 Audio Control Interface, which is designed to be rack-mounted; the mtu101 Boundary Microphone/Transmitter; and the cei007 Charging/Encryption Interface (optional).
drm141 Digital Receiver Module
• 25' shielded Category 5 (Cat 5) cable with RJ45 connectors for use between aci707 and drm141
• Ferrite bead (for use with user-supplied Cat 5 cable)
mtu101 Boundary Microphone Transmitter
• AA Alkaline batteries (2 batteries per transmitter)
aci707 Audio Control Interface
• IEC power cable
• Seven 3-pin Phoenix-type connectors (audio outputs)
• Two 8-pin Phoenix-type connectors (control i/o connections)
• 8" shielded Cat 5 cable with RJ45 connectors (for linking two aci707 units together)
cei007 Charging Encryption Interface
• Power supply
• Rechargeable AA NiMH batteries (14 batteries)
System Installation & Operation
Thank you for purchasing the Audio-Technica SpectraPulse™UWB wireless microphone
system. It is our hope that the system will bring you years of trouble-free performance.
Please follow the information contained in this manual closely, as it will assist you in using
your equipment effectively.
drm141 Digital Receiver Module
The drm141 Digital Receiver Module functions as both the UWB receiver and antenna for 14
channels. It consists of three assembly components that can be used for different mounting
requirements: the main assembly, the front bezel, and the plastic rear housing. Note: Do not
disassemble the main assembly. Doing so may void your warranty and possibly void the
authority to operate the unit.
Note: Never plug or unplug the shielded Cat 5 cable to or from the drm141 if the cable is
already connected to the aci707 and the power is on. Make certain aci707 power is off
before connecting or disconnecting the cable.
1. Placement – Locate the drm141 within 300 feet of the aci707. The drm141 Digital Receiver
Module should be mounted to a wall or ceiling or set on a flat surface. Ideal placement is
high, with clear line of sight to all the microphone/transmitter units. Note: The drm141 must
be in the same room as the microphone/transmitters.
5
2. To flush-mount the drm141 inside a 3-gang, 2-1/2" deep electrical box, see Mounting to a
3-gang electrical box, page 9.)
3. For more portable or surface applications, the unit is shipped assembled in the plastic rear
housing, which provides key-hole slots on the back for mounting on a wall; or the unit may
be placed on a flat surface. (See Mounting in the supplied plastic rear housing, page 9.)
4. Connect the shielded Cat 5 cable (supplied) to the RJ45 connector on the rear of the drm141.
The other end of this Cat 5 cable will be connected to the “Link In” RJ45 connector on the
rear of the aci707 Audio Control Interface (with aci707 power off). (See Link-Out and Link-In
RJ45 Connectors on page 11.) Note: A 25' shielded Cat 5 cable is supplied with the
system; you may supply your own shielded Cat 5 cable for lengths up to 300'. If you
use your own CAT 5 cable, attach the provided ferrite bead to the cable as close to the
drm141 as feasible. Do not plug cable from the aci707 into an Ethernet port.
aci707 Audio Control Interface
The SpectraPulse™aci707 Audio Control Interface provides the connection point to the audio
system, and a control platform to set the system functions. It also provides control interface
points (contact closures) for interface to external equipment. These closures can be used to
activate lights, control cameras, etc.
1. Placement – Locate the aci707 Audio Control Interface within 300 feet of the drm141 Digital
Receiver Module. Note: The aci707 does not have to be in the same room as the drm141.
2. Plug the aci707 Audio Control Interface into the AC power source. (See Power cord, page 11.)
Note: Make certain you do not turn on the power until after all the system connections
are made.
3. With the power off, connect the shielded Cat 5 cable exiting the drm141 to the “Link In”
RJ45 input connector on the rear of the aci707. Note: Do not plug RJ45 connector or Cat
5 cable into the aci707 with the power on. Do not plug cable from the aci707 into an
Ethernet port. (See Link-Out and Link-In RJ45 Connectors on page 11.)
If a second aci707 is used, connect the included 8" shielded Cat 5 cable from the Link-Out
on the first aci707 to the Link-In in the second aci707.
(contined on page 6)
Loading...
+ 11 hidden pages