Audio Technica PRO-5 Owners Manual

Pro Series 5
UHF Wireless Systems
Installation and Operation
PRO-501
UniPak® Transmitter System
PRO-501/G
PRO-501/H
Headworn Microphone System
PRO-501/H92
Miniature Headworn Microphone System
PRO-501/H92-TH
Miniature (beige) Headworn Microphone System
PRO-501/L
Lavalier Microphone System
PRO-502
Handheld Microphone System
2
Pro Series 5 Installation and Operation
This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference.
This device complies with INDUSTRY CANADA R.S.S. 210, en conformité avec IC: RSS-210/CNR210. Operation issubject to the following conditions: 1) This device may not cause harmful interference and 2) this device must accept any interference received, including interference which may cause undesired operation. Changes or modications not expressly approved by Audio-Technica could void your authority to operate this equipment.
CAUTION! Electrical shock can result from removal of the receiver cover. Refer servicing to qualied service personnel. No user­serviceable parts inside. Do not expose to rain or moisture.
The circuits inside the receiver and transmitter have been precisely adjusted for optimum performance and compliance with federal regulations. Do not attempt to open the receiver or transmitter. To do so will void the warranty, and may cause improper operation.
Notice to individuals with implanted cardiac pacemakers or AICD devices:
Any source of RF (radio frequency) energy may interfere with normal functioning of the implanted device. All wireless microphones have low-power transmitters (less than 0.05 watts output) which are unlikely to cause difculty, especially if they are at least a few inches away. However, since a “body-pack” mic transmitter typically is placed against the body, we suggest attaching it at the belt, rather than in a shirt pocket where it may be immediately adjacent to the medical device. Note also that any medical-device disruption will cease when the RF transmitting source is turned off. Please contact your physician or medical-device provider if you have any questions, or experience any problems with the use of this or any other RF equipment.
Thank you for choosing an Audio-Technica professional wireless system. You have joined thousands of other satised customers who have chosen our products because of their quality, performance and reliability. This Audio-Technica wireless microphone system is the successful result of years of design and manufacturing experience.
Each Pro Series 5 wireless system provides a choice of eight PLL synthesized UHF frequencies in the 542-561 MHz band (TV channels 26-29). All Pro Series 5 wireless systems offer both manual and automatic frequency scanning. Each wireless system includes a receiver and either a body-pack or handheld transmitter. Individual components are also available separately.
The PRO-R500 receiver features Diversity Reception. Logic circuitry monitors reception, selecting the superior signal from two antennas, providing better sound quality and reducing the possibility of interference and dropouts. Soft-touch controls provide convenient access to selection of operating frequency and automatic scanning, while an LED display indicates selected channel and scanning operation.
®
The versatile PRO-T501 UniPak low- and high-impedance inputs plus a bias connection, for use with dynamic and electret condenser microphones, as well as Hi-Z instrument pickups. The UniPak® transmitter also offers separate trim controls for guitar and microphone, plus switchable high/low RF power.
body-pack transmitter has both
Transmitters in the Pro Series 5 use two 1.5V AA batteries for economical operation and wide availability. Both transmitters also feature a multi-color Power/Mute/Battery indicator.
Pro Series 5 receivers feature a sophisticated Tone Lock™ tone squelch system that opens the receiver’s audio output only when a Pro Series 5 transmitter is detected, reducing the possibility of interference. As a result, Pro Series 5 transmitters and receivers must be used together and should not be used with components from other Audio-Technica wireless systems, or with those of other manufacturers.
Please note that in multiple-system applications there must be a transmitter-receiver combination set to a separate channel (frequency) for each input desired (only one transmitter for each receiver).
Because the wireless frequencies are within UHF TV frequency bands, only certain channels (operating frequencies) may be useable in a particular geographic area. The eight channels (operating frequencies) that are used in the Pro Series 5 have been selected for multi-channel compatibility. Subject to frequency availability in a particular geographic area, any of these eight channels may be used together.
The operating frequencies that correspond to each of the eight channels are listed on page 7.
Receiver Installation
Location
For best operation the receiver should be at least 3' (1 m) above the ground and at least 3' (1 m) away from a wall or metal surface to minimize reections. Keep the receiver antennas away from noise sources such as digital equipment, motors, automobiles and neon lights, as well as away from large metal objects. In multi-channel systems, position receivers at least 3' (1 m) apart and keep operating transmitters at least 6' (2 m) from the receivers to help assure maximum RF performance.
Output Connection
There are two audio outputs on the back panel: balanced (-16.5 dBV) and unbalanced (-13.5 dBV). Use shielded audio cable for the connection between the receiver and the mixer. If the input of the mixer is a 1/4" jack, connect a cable from the 1/4" unbalanced audio output on the back of the receiver housing to the mixer. If the input of the mixer is an XLR-type input, connect a cable from the balanced XLR-type audio output on the back panel to the mixer.
Power Connection
Connect the DC plug on the included AC power adapter to the DC power input on the back of the receiver. Secure the cord over the cord hook on the back of the receiver, to keep the plug from being detached by an accidental tug on the cord. Then plug the adapter into a standard 120 Volt 60 Hz AC power outlet.
Antennas
Extend the permanently attached UHF antennas. The antennas are normally positioned in the shape of a “V” (both 45° from vertical) for best reception. Diversity Indicators on the receiver front panel will indicate which antenna is active.
The PRO-T502 handheld dynamic microphone/transmitter features a rugged dynamic unidirectional element designed for professional live­sound venues.
Receiver Controls and Functions
3
Pro Series 5 Installation and Operation
1 1
2 4 5 6
3
Figure A — Front Panel Controls and Functions
1. ANTENNAS: Position the antennas as shown in Figure A Fully extend both antennas by pulling on the endcaps.
2. AF PEAK INDICATOR: Indicates when maximum transmitter modulation without distortion has been reached. Not affected by position of Volume control (Fig. B).
3. LED WINDOW: LED Display indicates channel setting and scanning operation.
4. DIVERSITY INDICATORS: Indicates which antenna (A or B) has better reception and is in operation.
5. SELECT BUTTON (for manual channel selection): Press the Select button repeatedly until desired channel is reached. Press and hold the Set/Scan button to manually set the receiver to indicated
6. SET/SCAN BUTTON: The Set/Scan button can be used in two ways: 1) in conjunction with the Select button to permit manual selection of an operating channel in Manual Set Mode (see “Select button” description above); and 2) Automatic Scan/Set Mode, to initiate the automatic channel scan and selection, as follows: Automatic Scan/Set Mode: Press and hold the Set/Scan button for about two seconds. The current channel will ash three times quickly; then the system will begin to scan for the next open channel. When it nds an open channel, it will ash the open channel three times and then set the channel. (If an open channel is not found, the automatic scan will return to the
original channel and ash 5 times.) channel. Channel number will stop ashing. (A brief touch of the Set/Scan button will revert to previously set channel). If the Set button is not pressed within 10 seconds to conrm the selection, the system will revert to its original channel.
1 2 43 5
Figure B — Rear Panel Controls and Functions
1. UNBALANCED AUDIO OUTPUT JACK:
1
/4" phone jack. Can be connected to an unbalanced aux-level input of a mixer, guitar amp or tape recorder.
2. AF LEVEL (VOLUME) CONTROL: Adjusts audio output level of both AF Output jacks; maximum output is fully clockwise.
3. BALANCED AUDIO OUTPUT JACK: XLRM-type connector. A standard 2-conductor shielded cable can be used to connect the receiver output to a balanced microphone-level input on a mixer or integrated amplier.
4. CORD HOOK: Loop the cord around the cord hook to keep the DC plug from pulling out accidentally.
5. POWER INPUT JACK: Connect the DC plug from the included in-line AC adapter.
Loading...
+ 5 hidden pages