Audio-Technica AE2300 Specifications

AE2300
Cardioid Dynamic Instrument Microphone
Features
• Tailored to capture sound from guitar amps, brass and woodwinds, drums and percussion instruments with equal clarity and precision
• Proprietary double-dome diaphragm construction improves high­frequency and transient response
• Excels in high-SPL applications and maintains directionality across the entire frequency range
• Minimal off-axis coloration (frequency response is nearly identical at 0°, 90°, and 180°) helps to maintain phase coherence in multiple microphone setups
• Switchable low-pass lter removes harsh, high-frequency content without negatively affecting the overall tone of an instrument
• Low-prole design allows microphone to be placed easily and unobtrusively in a wide variety of setups
• Rugged, brass metal construction ensures dependable performance in live music applications
• Isolation stand clamp provides secure mounting, versatile positioning, and effective dampening of unwanted mechanical noise
artist elite® live sound microphones
Operation and Maintenance
Output is low impedance (Lo-Z) balanced. The signal appears across Pins 2 and 3; Pin 1 is ground (shield). Output phase is “Pin 2 hot”— positive acoustic pressure produces positive voltage at Pin 2.
To avoid phase cancellation and poor sound, all mic cables must be wired consistently: Pin 1-to-Pin 1, etc.
An integral 6,000 Hz low-pass lter provides easy switching from a at frequency response to a high-end roll-off. The roll-off position reduces the pickup of high-frequency noise, such as hiss from a guitar amp or high­hat bleed into the snare sound. To engage the low-pass lter, use the end tip of a paperclip or other small pointed instrument to slide the switch toward the “bent” line.
Avoid leaving the microphone in the open sun or in areas where temperatures exceed 110° F (43° C) for extended periods. Extremely high humidity should also be avoided.
Take care to keep foreign particles from entering the windscreen. An accumulation of iron or steel lings on the diaphragm, and/or foreign material in the windscreen’s mesh surface, can degrade performance.
Description
The AE2300 is a dynamic microphone with a cardioid polar pattern. It is designed specically for musical instrument pickup in the studio and on stage.
The cardioid polar pattern of the microphone is more sensitive to sound originating directly in front of the element, making it useful for controlling feedback and reducing pickup of unwanted sounds.
The output of the microphone is a 3-pin XLRM-type connector.
The microphone is equipped with a switch that permits choice of at response or high-frequency roll-off (via integral 6 kHz low-pass lter).
The microphone is enclosed in a rugged housing. The included AT8471 isolation clamp permits mounting on any microphone stand with 5/8"-27 threads. A soft protective pouch is also included.
To reduce the environmental impact of a multi-language printed document, product information is available online at www.audio-technica.com in a selection of languages.
An de réduire l’impact sur l’environnement de l’impression de plusieurs langues, les informations concernant les produits sont disponibles sur le site www.audio-technica.com dans une large sélection de langue.
Para reducir el impacto al medioambiente, y reducir la producción de documentos en varios leguajes, información de nuestros productos están disponibles en nuestra página del Internet: www.audio-technica.com.
Para reduzir o impacto ecológico de um documento impresso de várias linguas, a Audio-Technica providência as informações dos seus produtos em diversas linguas na www.audio-technica.com.
Per evitare l’impatto ambientale che la stampa di questo documento determinerebbe, le informazioni sui prodotti sono disponibili online in diverse lingue sul sito www.audio-technica.com.
Der Umwelt zuliebe nden Sie die Produktinformationen in deutscher Sprache und weiteren Sprachen auf unserer Homepage: www.audio-technica.com.
Om de gevolgen van een gedrukte meertalige handleiding op het milieu te verkleinen, is productinformatie in verschillende talen “on-line” beschikbaar op: www.audio-technica.com.
www.audio-technica.com
本公司基于减少对环境的影响,将不作多语言文檔的印刷,有关产品信息可在 www.audio-technica.com的官方网页上选择所属语言和浏览。
Specications
Element
Polar pattern
Frequency response
High frequency roll-off
Open circuit sensitivity
Impedance
Switches
Weight
Dimensions
Output connector
Audio-Technica case style
Accessories furnished
In the interest of standards development, A.T.U.S.
offers full details on its test methods to other industry
1 Pascal = 10 dynes/cm
1
Typical, A-weighted, using Audio Precision System One.
Specications are subject to change without notice.
professionals on request.
2
= 10 microbars = 94 dB SPL
AE2300
Dynamic Cardioid 60-20,000 Hz 6,000 Hz, 6 dB/octave –57 dB (1.4 mV) re 1V at 1 Pa 250 ohms Flat, roll-off 138 g (4.9 oz)
95.6 mm (3.8") long,
28.0 mm (1.1") maximum diameter Integral 3-pin XLRM-type S4 AT8471 isolation stand clamp for 5/8"-27 threaded stands; 5/8"-27 to 3/8"-16 threaded adapter; soft protective pouch
frequency response: 60 –20,000 Hz
10 dB
Response in dB
50
100
LEGEND
polar pattern
330˚
300˚
270˚
240˚
210˚
SCALE IS 5 DECIBELS PER DIVISION
Audio-Technica Corporation audio-technica.com ©2016 Audio-Technica P52586-01
500
200
Frequency in Hertz 12" or more on axis Roll-off
30˚
150˚
180˚
1k
60˚
120˚
90˚
2k
LEGEND
200 Hz
1 kHz 5 kHz 8 kHz
5k
10k
20k