AUDIOFOCUS VENU, VENU12, VENU10, VENU8, VENU15 User Manual

Page 1
VENU series
USER’S MANUAL V1.0
Page of 1 19
USERS MANUAL V1.0
Page 2
Page of 2 19
USER’S MANUAL V1.0
Page 3
1 SUMMURY
2 SECURITY STATEMENT
2.1 NORMS
2.2 HANDLING
2.3 SOUND LEVEL
3 SYSTEM COMPONENT
3.1 INTRODUCTION
3.2 VENU series
3.3 LOW END
3.4 HARDWARE AND COVER
4 SETUP
4.1 VOLUME
4.2 PRESET SELECTION
4.3 DELAY
4.4 EASEFOCUS PREDICTION
4.5 DIRECTIVITY
4.6 RIGGING
4.7 WIRING
4.8 ETHERNET PORT
4.9 MAINTENANCE
5 TECHNICAL SPECIFICATIONS
6 CONTACT AND LINK
Page of 3 19
USER’S MANUAL V1.0
Page 4
2 SECURITY STATEMENT
2.1 NORMS
LDC,EMC,RoHS and CE guidelines
Audiofocus s.a. rue du Polissou 17 B-5590 Achêne Belgium Tel: +32 (0) 83 21 80 54 Fax: +32 (0) 83 21 80 57
declare that the VENU series and VENU series hardware are conform to the CE registration.
Tests standard: IEC60065:2001+A1 and EN60065:2002+A1:2006 EN55013:2001+A1/2003+A2:2006 EN55020:2002=A1:2003+A2:2005 EN61000-3-2:2000+A2:2005 EN61000-3-2:2295+A1:2001+A2:2005
Ing. Xavier Marchal Audiofocus R&D Director
Maximum load have been tested and approved by Vinçotte, s.a.-CERTEST Products
2.2 HANDLING
Keep this device away from rain and moisture!
AUDIOFOCUS© is not responsible for third party material use, for example foot lift.
2.3 SOUND LEVEL
VENU series can deliver high sound pressure level that could damage ear permanently. The system has to be used with care for the user and public exposed to sound.
Page of 4 19
USER’S MANUAL V1.0
Page 5
3 SYSTEM COMPONENT
3.1 INTRODUCTION
Thank you for choosing the AUDIOFOCUS© VENU series.
VENU come in four different format: 8 inches, 10 inches, 12 inches and 15 inches.
This user manual contains essential information for rigging and deploying VENU series
elements to their full capability. Carefully read this document in order to become familiar
with the system.
Whether you’re using it laid, pole mounted or lifted, we’re sure you will find the VENU
series to be highly versatile units in your professional sound reinforcement inventory.
3.2 VENU series
VENU series are high end two ways versatile speaker that can also be used on a stand as
a FOH alone or with subwoofer or as a monitor suitable for a wide range of sound
reinforcement applications from small to medium scale concerts, installation or theater
where sound quality is crucial.
VENU series come as an active self-powered unit or passive unit.
VENU series can be fine tuned via AF Manager software. Please refer to AF Manager
manual for more informations.
Page of 5 19
USER’S MANUAL V1.0
Page 6
3.3 LOW END
3.3.1 S15/S18/S21
VENU series can be used with the S series self powered subwoofer. System can be configured as needed.
3.4 HARDWARE AND COVER
Page of 6 19
USER’S MANUAL V1.0
Page 7
The VENU back amp cover protect the system from direct rain and direct sunshine. Ambient temperature and amplifier temperature are related but not the same! (amplifier start limiting at 75°c)
Flightcase for VENU series and rain cover are recommended to ensure a long life to the system.
4 SETUP
Page of 7 19
USER’S MANUAL V1.0
Page 8
The four LEVEL/PRESET LED always display the preset engage. They will display the level setting while changing level and delay setting while changing delay.
Fonction
description
Preset description
4.1 VOLUME
Page of 8 19
USER’S MANUAL V1.0
Encoder
Status LED
Signal LED
Page 9
Turning the rotative encoder give direct access to volume change.
The signal led blink while changes are being made. The four LEVEL/PRESET led display the level adjustment:
4.2 PRESET SELECTION
Pushing one time the rotative encoder give access to preset selection. Once the right preset is selected, push 2 seconds to validated the choice.
The VENU series amplifier come with 4 presets choices:
Preset 1: EXTENDED. Preset with low end extension which give the feel of a subwoofer addition.
Preset 2: FULL RANGE. Preset used with the combination of a subwoofer.
Preset 3: MONITOR. Preset when VENU is set up as a floor monitor.
Preset4: HP. Preset without low end to maximise the power on the vocal frequency range. Can be used in a four way configuration too.
Preset 5 to 8 are the same but can be modified by user within the help of AF network manager software.
Page of 9 19
USER’S MANUAL V1.0
Page 10
4.3 DELAY
Pushing the rotative encoder 5seconds give access to delay selection. Each step is 5meters delay increase. For longer or accurate tuning, use the AFNetworkManager software.
Page of 10 19
USER’S MANUAL V1.0
Page 11
4.4 EASEFOCUS PREDICTION
Please refer to Easefocus quick start guide.
4.5 DIRECTIVITY
VENU 8 and 10 have a symmetrical directivity of 80°. VENU 12 and 15 have a directivity of 60°x100°. The horn directivity of VENU12 and VENU15 can be adjusted regarding the need of the configuration and this with every preset in used. Front grill must be removed and horn unscrewed to be adjusted.
4.6 RIGGING
VENU series can be hang using AUDIOFOCUS© accessories.
Page of 11 19
USER’S MANUAL V1.0
Page 12
VENU series can also be hang by using the M8 port on the side of the cabinet with proper eye bolt:
Page of 12 19
USER’S MANUAL V1.0
Page 13
4.7 WIRING
Audiofocus power and signal cables with the appropriate section, length and connectors for passive and active speaker are recommended
Connect power and signal cables as describe on the technical drawing. Make sure the preset, volume are right. Check the signal output before application.
Page of 13 19
USER’S MANUAL V1.0
XLR OUTPUT
XLR INPUT
POWERCON LINK
POWERCON INPUT
AFMANAGER AESOP DANTE(option)
ENCODER
Page 14
4.8 ETHERNET PORT
AF network manager software allows you to change parameters of amplifiers (preset, input delay, input EQ, volume, phase).! AF network manager software run on a windows environment. It connects to amplifier module thru the RJ45 port with CAT6 cable. Secondary port allow to connect following module from one to the other. ! AF network manager work on a fixed IP architecture. Please refer to network quick start manual for more information. ! RJ45 port can handle both AF network manager, AESOP and Dante (option) at the same time.!
4.9 MAINTENANCE
Remove the cover if any liquid hit it, let it dry. If you need to clean it, use no agressive product for synthetic material.
You want to have regular check of the general aspect of the cabinet. Wood paint part can be clean with maintenance furniture product, metal part with a microfiber.
Audiofocus preset upgrade is available on every speaker thru AF Manager software, with a RJ45 connection. See AUDIOFOCUS website for the last upgrade.
Page of 14 19
USER’S MANUAL V1.0
Page 15
5 TECHNICAL SPECIFICATIONS
VENU8 Description 2-way, Vented self-powered/passive speaker
Usable bandwith (-3dB): Passive: 67 Hz-20 kHz Active : 55 Hz-20 kHz Maximum SPLrms/1m: Passive: 121 dBSPL Active: 125 dBSPL Maximum SPL peak/1m (Burst pink noise on HP preset): Passive: 128 dB (Crest factor 9dB) Active: 133dB (Crest factor 11dB) Coverage directivity (-6dB): 80° conical Active Input impedance:10 kΩ balanced Passive impedance:8ohm Passive sensitivity 1W/1m: 95dBSPL RMS power handling: Passive: 400Wrms / 800W peak Active: 500Wrms/ 800W peak Wedge angle 40° from vertical (left and right, mirror wedge) Connectors: Analog, AES (RJ45), Dante (RJ45) Weight: Active: 11,5kg /25.4lb Passive: 10,1kg/22.3 lb Baltic birch plywood Finish Black polyurethane coating UV resistant Dimensions (HxWxD) 430 x 275 x 290 mm 16,77’’ x 10,82’’ x 11,41’’
Page of 15 19
USER’S MANUAL V1.0
Page 16
VENU10 Description 2-way, Vented self-powered/passive speaker
Usable bandwith (-3dB): Passive: 65 Hz-20 kHz Active: 50 Hz-20 kHz Maximum SPL rms/1m : Passive: 123 dBSPL Active: 125# dBSPL Maximum SPL peak/1m (Burst pink noise on HP preset): Passive: 131 dB (Crest factor 8dB) Active: 134 dB (Crest factor 10dB) Coverage directivity (-6dB): 80° conical Active Input impedance:10 kΩ balanced Passive impedance:8ohm Passive sensitivity 1W/1m: 97dBSPL RMS power handling: Passive: 400Wrms / 800W peak Active: 500Wrms/ 800W peak Wedge angle 45° from vertical (left and right, mirror wedge) Connectors: Analog, AES (RJ45), Dante (RJ45) Weight: Active: 15,5kg /34,2lb Passive: 14,6kg/32.2 lb Baltic birch plywood Finish Black polyurethane coating UV resistant Dimensions (HxWxD) 495x 320 x 295 mm 19,49’’ x 12,59’’ x 11,61’’
Page of 16 19
USER’S MANUAL V1.0
Page 17
VENU12 Description 2-way, Vented self-powered/passive speaker
Usable bandwith (-3dB): Passive: 60 Hz-20 kHz Active: 40 Hz-20 kHz Maximum SPL rms/1m : Passive: 124 dBSPL Active: 127# dBSPL Maximum SPL peak/1m (Burst pink noise on HP preset): Passive: 133 dB (Crest factor 9dB) Active: 136 dB (Crest factor 9dB) Coverage directivity (-6dB): 100°x60° rotative horn Active Input impedance:10 kΩ balanced Passive impedance:8ohm Passive sensitivity 1W/1m: 97dBSPL RMS power handling: Passive: 600Wrms/ 1600W peak Active: 1000Wrms / 1800W peak Wedge angle 45° from vertical (left and right, mirror wedge) Connectors: Analog, AES (RJ45), Dante (RJ45) Weight: Active: 18,5kg /40,8lb Passive: 17,3kg/38.1 lb Baltic birch plywood Finish Black polyurethane coating UV resistant Dimensions (HxWxD) 566x 362 x 357 mm 22,28’’ x 14,25’’ x 14,05’’
Page of 17 19
USER’S MANUAL V1.0
Page 18
VENU15 Description 2-way, Vented self-powered/passive speaker
Usable bandwith (-3dB): Passive: 55Hz-20 kHz Active: 36Hz-20 kHz Maximum SPL rms/1m : 127# dBSPL (passive) 127,5 dBSPL (active) Maximum SPL peak/1m (Burst pink noise on HP preset): Passive: 135 dB (Crest factor 9dB) Active: 136,5 dB (Crest factor 8dB) Coverage directivity (-6dB): 100°x60° rotative horn Active Input impedance:10 kΩ balanced Passive impedance:8ohm Passive sensitivity 1W/1m: 97dBSPL RMS power handling: Passive: 900Wrms/ 1800W peak Active: 1100Wrms / 2000W peak Wedge angle 45° from vertical (left and right, mirror wedge) Connectors: Analog, AES (RJ45), Dante (RJ45) Weight: Active: 18,5kg /40,8lb Passive: 17,3kg/38.1 lb Baltic birch plywood Finish Black polyurethane coating UV resistant Dimensions (HxWxD) 566x 362 x 357 mm 22,28’’ x 14,25’’ x 14,05’’
6 CONTACT AND LINK
www.audiofocus.eu
Page of 18 19
USER’S MANUAL V1.0
Page 19
info@audiofocus.eu
www.facebook.com/AudiofocusPage/
www.facebook.com/groups/AUDIOFOCUS/
Page of 19 19
USER’S MANUAL V1.0
Loading...