Introduction
The ADX is the industry’s most controllable analog audio matrix, featuring multiple control interfaces and an attractive design
that is sure to compliment any equipment rack or shelf. Capable of distributing sixteen analog audio channels to sixteen
destinations, it is the perfect solution for analog audio distribution in both small and medium size installations.
Features
• Sixteen source input, sixteen zone output matrix switcher (ADX-1616) or eight source input, eight zone output matrix
switcher (ADX-0808)
• Rack mountable with included 2U rack mount ears
• Control via Ethernet, RS-232 Serial, front panel IR, rear panel IR, and front panel controls
• Capacitive touch front panel – easy to clean and no physical buttons to wear out
• IR codes available for use with third party control systems
• USB 1.1 and 2.0 compliant for the convenient Import and Export of system congurations as well as future Firmware
updates
• Manufactured in Lexington, Kentucky USA
Carton Contents
• Model ADX-1616 or ADX-0808 Analog Audio Matrix
• 18-volt power supply
• Rack ears
• User manual
Other Materials You May Need
• Patch cables (Ethernet, RCA)
• Infrared receiver
• Third party programmable remote
• USB 1.1 or USB 2.0 compliant drive
Warnings
To reduce the risk of re or electric shock, do not expose this unit to rain or moisture.
The exclamation point symbol alerts users to important operating and
maintenance instructions in this booklet.
!
• Read this manual before installing or using this product.
• This product must be installed by qualied personnel.
• Do not open the cover—there are no user-serviceable parts inside.
• Do not expose this unit to excessive heat.
• Install only in dry, indoor locations.
• Do not obstruct the ventilation slots.
• Clean the unit only with a dry or slightly dampened soft cloth.
4
Page 5
ADX Series
Audio Matrix Switcher
Dim Button
J
S
O
USB
18V DC
POWER
R
www.audioauthority.com
1- SLEEVE = +12V
2- RING = GROUND
800-322-8346 • 859-233-4599
Model ADX-1616 Audio Matrix
GF
LINK
SPEED
ETHERNET
IR
IJ
N
E
H
3- TIP = SIGNAL
INPUT
RS-232 SERIAL
3.5MM
IR
Q
P
3.5MM IR Input Jack
3-Wire IR Input Terminal Block
5.5MM 18V Center Positive Power Connection
Q
R
S
All Selection Button
G
Multi Function Knob
D
Power Indication LED
Getting to Know the ADX
*ADX-1616 shown
A
Menu Selection Button
Back Button
H
I
Group Selection Button
Favorite Selection Button
E
F
Front Panel IR Receiver
Vacuum Fluorescent Display (VFD)
B
C
ADX Series
Audio Matrix Switcher
L
R
1 2 3 4 5 6 7 8
OUTPUT
ZONES 1 - 8
OUT TO AMPLIFIER
KM
INPUT
L
9 10 11 12 13 14 15 16INPUT
OUTPUT
L
R
ZONES 9 - 16
OUT TO AMPLIFIER
Ethernet Connector with Link and Speed Indicators
USB Connection Port
RS-232 DB9 Connector
N
O
P
ABCD
L
R
1 2 3 4 5 6 7 8
L
R
9 10 11 12 13 14 15 16
Analog Audio Input Jacks 1-16 for ADX-1616 or 1-8 for ADX-0808
DB25 Connector(s) for future use
Analog Audio Output Jacks 1-16 for ADX-1616 or 1-8 for ADX-0808
K
L
M
5
Page 6
Getting Started
• Conrm that nothing is missing from your shipping carton. Refer to Carton Contentson page 4.
• Record the serial number (found on the product rear panel) in the space provided on the inside of the front cover of this
manual for easy reference.
• Activate your warranty and receive future upgrade notications by registering your purchase on our website,
www.audioauthority.com/register.
• Read the entire instruction manual to become familiar with the various terms and operations of this product.
Although it is highly recommended that you follow the more detailed installation instructions provided in this manual, a very
basic installation may be accomplished by performing the following steps:
1. Connect your source equipment to the input jacks 1-16.
(You can nd detailed instructions in the Installation Section)
2. Connect your audio receiver equipment to the zone output jacks 1-16.
(You can nd detailed instructions in the Installation Section)
3. Connect the product to a suitable power outlet using only the power supply furnished. Once power has been
connected, the ADX will power on, there is no power button or switch. After a moment for the system to boot, the
ADX is ready to control your new audio system matrix. Use the front panel controls to select the input port number of
your preferred source and the output port number(s) of your preferred listening zones.
Now relax and enjoy your audio.
Choosing a Control Interface
For more detailed instructions on the various control methods available to you, please refer to the following sections:
• If you prefer to control the ADX through RS-232, see page 8
• If you prefer to control the ADX through Ethernet, see page 8
• If you prefer to control the ADX through IR, see page 9
• If you prefer to control the ADX with the Front Panel, see page 10
Control Interface
Capabilities
All commands are
available on Ethernet and
RS-232, but other control
methods are limited as
shown.
Audio signal switching
Dimming
Lock IR
Lock front panel interface
Change Ethernet settings
Upgrade rmware
Group and Favorite creation
Group and Favorite switching
RS-232Ethernet Infrared Front Panel
XXXX
XXX
XX
XX
XX
X
XX
XXXX
6
Page 7
Installation
The ADX is easy to set up for both simple and advanced installations. Perform the following steps.
Installing the ADX
The ADX is conveniently designed so that it may be installed either on a shelf or in
a standard 19-inch equipment rack. If rack mounting, remove the feet and the cover
screws adjacent to the front panel of the unit. Reuse the cover screws to mount the
Model 1192A rack adapters supplied with the ADX. Be sure to place a spacer under
the adapters at every screw location. Secure the ADX to the rails of the equipment
rack with the screws supplied with the rack adapter kit.
Initial Audio Setup
Independently test each component to be connected to the ADX prior to system assembly. This will greatly reduce
time-consuming troubleshooting measures later. Verify basic ADX functionality by performing the
following steps:
1. Connect one source unit to a pair of input jacks numbered 1-8.
2. Connect one audio receiver to a pair of zone output jacks numbered 1-8.
3. Use high quality cable and keep the lengths as short as possible.
4. Turn on the source, receiver and the ADX for an initial test. Verify the audio pathway is performing acceptably by selecting
the appropriate source input and zone output from the front panel (detailed instructions for Front Panel operation can be
found on page 10). You should now hear the source material being played. If you do not, please refer to the Troubleshooting section found on page 16. If you are still experiencing difculty, please contact Technical Support by
phone at 859-233-4599 or toll free in the US at 1-800-322-8346.
5. Repeat steps 1-4 with jacks numbered 9-16.
6. If no problems have been noted, remove power and continue installation.
I/O Connections and Testing
• Determine the correct wiring conguration for your setup. It is a good idea to label the RCA cables as to the actual location
they either come from or go to (e.g. Input 1 - Cable Box, Input 2 - Music Server, Zone 1 - Kitchen, Zone - 2 Living Room etc.)
Be sure to use good quality RCA cables for optimal results.
• Connect the ADX power supply; the unit will immediately power on.
• Apply power to all sources and associated equipment. Use the front panel controls to verify audio signal integrity of sources
at each zone location.
7
Page 8
Advanced Setup and Remote Control Options
USB
Using the RS-232 Port.
System controllers and PCs can send all setup and control commands as well as receive feedback via the RS-232 serial port.
• Important: If a PC is connected directly to the ADX RS-232 port, use a standard serial cable.
• The baud rate is set to 9600 by default, but this may be changed using the Front Panel Menu screen “Serial”. The other
connectivity parameters are xed to 8 data bits, no parity, 1 stop bit, and no ow control.
• See the table and diagram below for the ADX serial port pinout.
This control method is capable of performing all commands (See Appendix A).
Transfer Rate
Data Bits
Parity
Stop Bits
Flow Control
Character type
Connector
Electrical Rat-
9600 bps Default (may be changed, see Appendix A)
8
None
1
None or Off
ASCII
DB-9
Pins 2 and 3, ±15 VDC
GND RX TX
5 4 3 2 1
9 8 7 6
DB-9 connector on rearpanel of ADX
P
ing
Pin out
Pin 2, Tx
Pin 3, Rx
Pin 5, Ground
Shell, Ground
Actual screen from ADX showing Serial Settings
Ethernet
Serial commands can be issued using an Ethernet connection and a telnet program.
There are two LED indicators located next to the Ethernet port on the rear panel that will help in identifying connection
issues:
ETHERNET
LINK
SPEED
• Link - The Link LED is steadily lit if a connection is detected and ashes when activity is present.
• Speed - The Speed LED is off for 10 base T, and on for 100 base T.
N
Using the Ethernet Port
Use of a telnet client or terminal program on a Mac or PC allows commands to be sent through the Ethernet port on
the ADX. Connect a PC directly to the Ethernet port using a crossover cable, or alternatively use a standard Ethernet hub
or switch and a standard patch cable. Once connected to a PC or network, the ADX by default will attempt to obtain an IP
address automatically using DHCP. To use Static settings, see the detailed instructions on page 9.
8
Page 9
DHCP
If DHCP is enabled on your network, simply connecting the ADX to the network with an existing DHCP server will enable it to
obtain all necessary information. DHCP is enabled on the ADX by default.
Static addressing connected directly to a PC
The ADX must be given an IP address which will not conict with the PC. Go to the network settings (which are found in
control panel -> network -> local connection properties of a PC running Windows XP).
Change the TCP/IP protocol properties, and set the IP address, gateway, and subnet mask, if they are not already set.
This can be arbitrarily done on a direct connection, but a good choice for the settings would be IP address of 192.168.0.1,
subnet mask of 255.255.255.0, and an empty default gateway. Once these values have been set, use serial commands to
set the network settings of the ADX-1616 in a similar manner, but use a different IP address than that of the computer (for
example, 192.168.0.2).
Static addressing on a network
The ADX must be set to the same settings as the PC except for the IP address, which must be one available on the network.
To determine this in Windows, use the DOS prompt (Start->Run->cmd) commands ipcong and ping. Ipcong will list the PC’s
settings, and ping will allow you to test addresses to make sure that nothing else on the network has that address. Enlist the
help of a network administrator if you are unfamiliar with setting up a network connection.
Once connectivity is established, a telnet program such as Hyper Terminal, Teraterm, PuTTY etc, must be used to connect
to the device. Enter the IP address of the ADX and leave the default port (23) to connect. Once connected, standard serial
commands (listed in Appendix A) can be issued in an identical manner to serial control.
Actual screen from ADX showing Network
Settings with DHCP set to ON
Using a Comprehensive IR Control System
The ADX uses a three wire IR circuit. It is imperative that the correct polarity be maintained when connecting third party IR
equipment. The 3.5MM pinout is shown in the illustration below and the connecting block pinout is screen printed on the back
panel of the ADX. Patch the IR signal from your IR receiver directly to the IR input port on the rear panel using the connection method of your choice. Alternatively, you may place a stick-on emitter from your infrared system on the ADX front panel
receiver.
If the ADX IR codes are available from your remote control company, download and/or activate those les.
A CCF le containing ADX codes can be downloaded from the Audio Authority
website,
www.audioauthority.com/page/software.
Tip = Signal
Tips for Using Infrared Control
• If you are using standard hand-held IR remote controls, ensure correct operation
by avoiding sources of light pollution such as Plasma and LCD TVs, direct
sunlight, uorescent light, etc. Experiment with the physical placement of the IR
receiver to avoid interference.
• If a source of interference cannot be eliminated or avoided, use IR receivers that
block that type of interference, such as Plasma-proof or LCD-proof receivers.
Ring = Ground
Sleeve = +12 Volts
9
Page 10
Operation
Front Panel
The front panel is operated by touching the sensitive key areas: Group , Favorite , All , Menu , Back , and Dim
to select the respective sub-menu. Once the desired screen has been selected, rotate the Multi Function Knob to navigate
to the item you want to change and press the knob to select that item. The previous selection is marked with a solid arrow “”,
and any others marked with an open arrow “.”
EFGHIJ
D
Zone/Source Selection Screen
This default screen performs zone/source switching. Rotating the knob while selecting the zone line selects a different zone.
Once the zone to be switched is selected, push the knob to move to the source selection line. Rotating the knob here allows a
new source to be selected for that zone. Press the knob to activate your selection.
Group Button > Group Selection Screen
This screen allows switching multiple output zones to a single input source through ten predened groups. Rotate the knob
while on the group selection line to choose the group. Push the knob to move the cursor to the source selection line. Rotate
the knob on the source selection line to select the source. Finally, push the knob to save the group of zones to the selected
source.
Group Switching
The ADX is capable of storing up to 10 Groups of Zones. Each Group may be assigned a unique name up to 16 characters in
length. Groups can only be congured and named using Serial commands. See Appendix A for the appropriate Group com-
mands.
Press the Group button, select the previously assigned Group number by rotating the knob until the desired Group is shown
and press the knob. Rotate the knob to select the desired Source.
E
Favorite Button > Favorite Selection Screen
This screen allows switching multiple output zones to multiple sources through ten predened favorites. Rotate the knob to
select a favorite, and push the knob to activate that favorite selection.
F
Favorite Switching
The ADX is capable of storing up to 10 Favorites of Source/Zone combinations. Each Favorite may be assigned a unique
name up to 16 characters in length. Favorites can only be congured and named using Serial commands. See Appendix A for
the appropriate Favorite commands.
Press the Favorite button, select the previously assigned Favorite number by rotating the knob until the desired Favorite is
shown and press the knob.
All Button > All Selection Screen
This screen allows switching all output zones to a single source. Rotate the knob to select a source, and push the knob to
activate the selection.
Back Button
Pressing this button will return you to the previous screen.
I
G
10
Page 11
Dim Button
This button toggles through four predened brightness levels for the VFD and keyboard LED indicators. After a ve minute
period, the VFD will enter a screen saver mode and turn off. The power and button LED’s will remain on at a very low level
to show that the unit is receiving power. Any key press or knob adjustment will cause the system to return the VFD and LED
indicators to the last selected brightness level.
J
Menu Button > Menu Screen
Press the Menu Button to access the following sub-menus: Volume, Tone and Balance, Equalizer, Serial, Network, Export File,
Import File, and Firmware Version.
Actual screens from ADX showing Menu selections
H
Volume
Turn the knob on the zone selection line to choose a zone to adjust, or all zones. Push
the knob to move the cursor to the volume adjustment line. Turn the knob on this line
to adjust the volume of the output zone up or down in real time. Push the knob to
return to the zone selection. In order to leave this screen, press the Back button .
Warning – adjusting the volume
levels of all zones at once can result
in high volume levels in unexpected
areas and should be done with
I
caution.
Tone and Balance
Turn the knob on the zone selection line to determine the active zone to adjust. Press the knob to cycle the cursor to the Bass,
Treble, and Balance parameter lines respectively. Turn the knob to adjust the parameter in real time. Bass and Treble levels
can be adjusted from -12dB to +12dB. The Balance level may be adjusted from +80 Left to +80 Right. Press the Back button
to return to the menu.
Equalizer
Turn the knob on the zone selection line to determine the active zone to adjust. Press the knob to cycle the cursor to the Band
and EQ lines respectively. Rotate the knob on the Band selection line to choose one of ten different frequency bands, ranging
from 32Hz to 16kHz. Rotate the knob on the EQ level line to adjust the selected Band from -10dB to +10dB. Press the Back
button to return to the menu.
Serial
Rotate the knob to select either 9600, 19200, or 115200 baud rate (9600 is the default) and press the knob to activate the
setting. The other connectivity parameters are xed to 8 data bits, no parity, 1 stop bit, and no ow control.
Network
Provides the current network settings information.
11
Page 12
Export File
With a USB 1.1 or USB 2.0 drive connected to the USB port on the rear panel of the ADX, simply follow the on screen
instructions to export to the default le name, “cong.adx”. If the le is already present, you will be prompted to overwrite it.
Note – The USB port is v1.1 and v2.0 compatible. There is a small delay when inserting a USB drive to identify the device and
mount the le system. Although many different drives were tested successfully with the system, not all USB drives will work
with the ADX. Tested le systems include FAT and FAT32.
O
Import File
This selection imports the conguration settings from a text le on a USB drive. Simply follow the on screen instructions to
select the le to import, which must have the “*.adx” format. Once the le has been selected, the fourth line of the screen
displays the commands as they are read from the le and a serial/telnet connection details the commands read and their
execution status.
Actual screens from ADX showing Export and Import prompts
Firmware Version
This screen details the rmware versions of the primary rmware and the boot-loader. The serial number is also displayed
here.
Actual screen from ADX showing
Firmware Versions and Serial Number
Programmable IR Remote
Operational codes may be downloaded directly from the Audio Authority website at www.audioauthority.com /page/software.
IR operation is possible via the front or back panel utilizing a programmable remote.
Please refer to your specic remote control User Manual to install the ADX code set.
Front Panel Lockout
The Front Panel Knob and Buttons can be locked out by serial commands. No front panel operation is possible while lockout is
enabled. If enabled, the VFD provides the message “Front Panel Lockout Activated.”
See Appendix A for serial commands.
12
Page 13
Appendix A: Serial Commands
DescriptionCommand StructureExample
Switch a zone
output to a
source input.
Switch all zones
to a single input
source.
Switch to
a favorite
zone/source
conguration.
Switch a group
of zones to the
specied source.
Query output
zone.
Name an output
zone.
Name an input
source.
Adjust zone
balance.
Adjust zone
equalization.
Adjust zone tone
control.
Set a zone
output volume
level.
Set all zones to
an output volume
level.
Un-mute a zone
output.
Mute a zone
output.
[CO##I##][CO1I2](CO1I2)Zone output 1 is connect to
[CXI##][CXI4](CXI4)All zone outputs are
[CF##][CF3](CF3)All zones that are a member
[CG##I##][CG1I3](CG1I3)All zones that are a member
[QO##][QO8](BO8L0R0)
[NO##”@”]
(Where @ represents up to
16 characters)
[NI##”@”]
(Where @ represents up to
16 characters)
[BO##L##R##][BO2L-3R0](BO2L-3R0)Zone 2 output level for the
[EO##B##L##][EO12B2L-4](EO12B2L-4)Zone 12 equalizer band 2 is
[TO##B##T##][TO2B-3T9](TO2B-3T9)Zone 2 output tone control
Returns the current settings
related to the output zone,
including balance, EQ levels
for each band, muting, tone,
volume level, current source
selection, and name.
left channel is attenuated 3
dB, while the right channel is
set at.
set to -4 dB.
is set to attenuate bass 3 dB
and amplify treble 9 dB.
is attenuated 10 dB from the
maximum level.
-30 dB.
and set back to the previously
set volume level.
13
Page 14
Query current
network
(Ethernet)
settings
Enable or disable
dynamic host
conguration
protocol (DHCP).
Dene the static
IP address.
Dene the
default gateway.
Dene the
subnet mask.
Set the serial
baud rate.
Query front panel
interface lockout
Enable or disable
front panel
interface lockout
Query front panel
IR lockout
Enable or disable
front panel IR
lockout
Set VFD
backlight and
LED dimming
level
Network Settings Adjustment
[QE][QE](DHCP1)
[DHCP#][DHCP1]
[DHCP0]
[IP###.###.###.###][IP192.168.0.212](IP192.168.0.212)Set the IP address to the
[GW###.###.###.###][GW192.168.0.2](GW192.168.0.2)Set the default gateway for
[NM###.###.###.###][NM255.255.255.0](NM255.255.255.0)Set the subnet mask, which
DHCP status, IP address,
subnet mask, gateway, and
MAC address are displayed by
this command.
DHCP is enabled (1) or
disabled (0). It is not possible
to statically set address while
DHCP is on.
specied value.
accessing computers outside
of the subnet.
determines the computers
that can be accessed without
traveling through the
gateway.
Baud rate is set to 9600 (0),
19200 (1), or 115200 (2)
Returns whether the front
panel interface is locked out
(1) or unlocked (0)
Front panel interface is locked
out (1) or unlocked (0)
Returns whether the front
panel IR is disabled (1) or
enabled (0)
Lock out front panel IR (1) or
allow it to operate (0)
level is set (0-3 are valid
levels)
14
Page 15
Favorites (see switching for activating a favorite conguration)
Query favorite.[QF##][QF10](F1AO1I3)
Add a zone/
source
combination to a
favorite.
Remove a
zone/source
combination from
a favorite.
Name a favorite.[NF##”@”]
Reset favorite
membership.
Query a group.[QG##][QG10](QG10)
Add a zone to a
group.
Remove a zone
from a group.
Name a group.[NG##”@”]
[F##AO##I##][F1AO3I2](F1AO3I2)Add to favorite 1 the zone 3,
[F##RO##][F1RO3](F1RO3)Remove zone 3 from favorite
[NF1”Gameday”](NF1”Gameday”)Favorite 1 is named
(Where @ represents up to
16 characters)
[FAR][FAR](FAR)All favorites now have no zone
Groups (see switching for activating a group conguration)
[G##AO##][G1AO3](G1AO3)Zone 3 is now a member of
[G##RO##][G1RO3](G1RO3)Zone 3 is removed from group
[NG1”Bedrooms”](NG1”Bedrooms”)Group 1 is named “Bedrooms”
(Where @ represents up to
16 characters)
(F1AO3I4)
(NF1”Favorite 1
Name”)
(QF10)
(NG10”Empty
Group”)
Query favorite membership
and settings. See the
favorite adding and naming
commands for how to read
the results.
source 2 combination.
1.
“Gameday”
members.
Group 10 has no members
and is named “Empty Group”
group 1.
1.
Reset group
membership.
Query the
current
conguration.
Load the
conguration
from memory.
Reset the
conguration to
factory defaults.
Save the current
conguration to
memory.
[GAR][GAR](GAR)All groups now have no zone
Conguration Utilities
[QX][QX](SC100)
(SD4)
(SBL100)
(SLED100)
(DHCP1)
…
[LOAD][LOAD](LOAD)Loads the conguration stored
[RESET][RESET](RESET)Loads the factory default
[SAVE][SAVE](SAVE)Saves the current
members.
All conguration information
is displayed.
in onboard memory.
settings for every option.
conguration settings
immediately. There is a
30 second timer which
automatically saves the
settings during normal
operation.
15
Page 16
Appendix B: Firmware Update Procedure
• The latest version of rmware is available for download from www.audioauthority.com/page/software.
• Save a copy of the rmware le to a USB drive.
• Power cycle the ADX, and press the knob just after power turns on and the screen displays “Press Knob to Update Firmware.”
• Insert the USB drive into the back of the unit.
• Follow the on screen prompts and select the downloaded le.
• After the rmware update is complete, you will be prompted to press the knob to reboot.
• The system will boot with the new rmware installed.
Appendix C: Troubleshooting
SymptomPossible Cause
No power• Check for available AC power from the wall outlet.
• Check to make sure there is 18V available from the provided power supply. If not, remove
the power supply from the wall and reconnect.
No Audio• Check for proper operation of Source and Receiver.
• Ensure cabling between the ADX and third party equipment is good and connected properly.
• Ensure power is connected to the ADX.
• Check volume levels at receiver and in ADX controls.
No Ethernet Control• Refer to Page 8 and Appendix A for Ethernet Setup and Control. If problem persists, contact
your Installer or Network Administrator for assistance.
No RS232 Response • Make sure the Baud Rate matches between the ADX and the Serial Terminal program being used
to issue commands. ADX Default = 9600
• Make sure Flow Control is turned off.
• Check cable pinout for compatibility between ADX and control equipment.
No USB Response• Ensure the USB storage device you are using is USB 1.1 or USB 2.0 compliant.
• Some USB storage devices may not be compatible with the ADX. If your device meets the standard
requirements but will not function with the ADX, try using a different USB storage device.
No IR Response• Check the Front Panel for “Front Panel Lockout Activated” message.
• Ensure proper connection and operation of any external IR receiver.
If you have exhausted the above troubleshooting suggestions and are still experiencing difculties,
contact Audio Authority Technical Support by phone at 1-859-233-4599 or toll free within the US at
1-800-322-8346. You can also email Technical Support at support@audioauthority.com.
16
Page 17
Specications
Audio Parameters
Analog/DigitalAnalog
Digital Input/Output TypeN/A
Input Impedance100K
Min Load Impedance10K
Multi-channel DigitalN/A
Frequency Response10-25kHz
S/N Ratio82dB
THD+Noise0.02%
Crosstalk-85dB
Power
Agency ApprovalsFCC
DC Input Connector5.5 x 2.1mm
DC Input Voltage/Polarity18V Center Positive
Max DC Input Current600mA/1.1A
Power Supply571-014/571-023
Heat Output38/68 BTU/hr
Limited Warranty
If this product fails due to defects in materials or workmanship within one year from the date of the
original sale to the end-user, Audio Authority guarantees that we will replace the defective product
at no cost. Freight charges for the replacement unit will be paid by Audio Authority (Ground service
only). A copy of the invoice from an Authorized Reseller showing the item number and date of purchase (proof-of-purchase) must be submitted with the defective unit to constitute a valid in-warranty
claim.
Units that fail after the warranty period has expired may be returned to the factory for repair at a
nominal charge, if not damaged beyond the point of repair. All freight charges for out-of-warranty
returns for repair are the responsibility of the customer. Units returned for repair must have a Customer Return Authorization Number assigned by the factory.
This is a limited warranty and is not applicable for products which, in our opinion, have been damaged, altered, abused, misused, or improperly installed. Audio Authority makes no other warranties either expressed or implied, including limitation warranties as to merchantability or fitness for
a particular purpose. Additionally, there are no allowances or credits available for service work or
installation performed in the field by the end user.
17
Page 18
18
Page 19
19
Page 20
2048 Mercer Road, Lexington, Kentucky 40511-1071
20
Phone: 859/233-4599 • Fax: 859/233-4510
Customer Toll-Free USA & Canada: 800/322-8346
Website: http://www.audioauthority.com
752-598
1/11
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.