Audient Sumo Operational Manual

Operational Manual
Version 1.0 – October 2004
Operational Manual
Contents
© Audient v1.0 10/2004
2
Copyright 2004. All rights reserved.
The information in this document is subject to change without notice.
Audient plc makes no warranty of any kind with respect to the material in this document and shall not be liable for errors contained herein or for incidental or consequential damages related to the use of the material.
No part of this document may be reproduced without the prior written consent of Audient plc.
Operational Manual
Contents
© Audient v1.0 10/2004
3
Thank you for buying this audient product.
As can be found throughout the Audient range, your Sumo has been painstakingly designed and lovingly nurtured to give you years of productive, reliable, mix fattening performance. To make the most of this, we suggest that you have a good look through this manual before you get started.
The safety and installation information will help you to set your Sumo up with the minimum of danger and hassle, while the operational guide will take you on a whistle stop tour of Sumo’s knobs, dials and flashy lights – along with some handy hints for their use. Finally, if you’re experiencing any problems Sumo Surgery will root out most set-up and configuration issues to get you back on track in no time.
Anywhere you see this symbol, you should make sure to read the adjacent warning. These will prevent you from killing yourself, blowing up speakers, and wrecking your mix. All of which are to be avoided.
Text next to one of these symbols is, wait for it… a handy hint.
These are little operational titbits and guidelines to help you find
your way and get the most out of your Sumo.
!
Operational Manual
Contents
© Audient v1.0 10/2004 4
CONTENTS
SAFETY INFORMATION 5
INSTALLATION 7 OVERVIEW – THE BENEFITS OF ANALOGUE SUMMING 8 PLUGS AND SOCKETS
Analogue audio interfaces 10 Digita l interfaces 11
HOOKING UP 12 KNOBS, BUTTONS AND FLASHY LIGHTS Input section 15 Mix Compressor/Peak Limiter 16 Mix master/monitor section 17 Digital section 18 SUMO SURGERY (TROUBLESHOOTING) 19 Why can’t I hear anything? 20 ACCESSORIES 21 SPECIFICATIONS 21 WARRANTY 22
Operational Manual
Important safety instructions
© Audient v1.0 10/2004 5
IMPORTANT SAFETY INSTRUCTIONS
WARNING
THIS EQUIPMENT MUST
BE
EARTHED. DO NOT EXPO
SE
TO RAIN OR MOISTURE.
Please read all of the following instructions and save them for later reference before attempting to connect your Sumo to the
AC power source.
CAUTION
ATTENTION
RISK OF ELECTRIC
SHOCK
DO NOT OPEN
RISQUE DE
CHOC
NE PAS ENLEVER
Operational Manual
Safety Information
© Audient v1.0 10/2004 6
SAFETY INFORMATION
EARTH
This unit is connected via its power cord to the mains safety earth. NEVER OPERATE THE UNIT WITH THIS EARTH CONNECTION REMOVED.
COVERS
DO NOT remove the covers. Refer servicing to qualified personnel only.
VOLTAGE
Sumo is set to operate only at the voltage shown on the rear panel. CHECK that the correct voltage is available before connecting the AC mains supply.
FUSES
CHECK that the fuse fitted is of the correct type for the local mains voltage. ALWAYS replace fuse with the correct type.
MOISTURE
DO NOT expose the unit to rain or moisture. If your Sumo should become so exposed REMOVE the mains power immediately.
HEAT
ALWAYS site the Sumo away from sources of heat including direct sunlight and ensure adequate ventilation around the unit.
Operational Manual
Installation
© Audient v1.0 10/2004 7
INSTALLATION
Unpacking
Your Sumo has been carefully and meticulously tested before despatch.
Please check for any signs of transit damage. If any signs of mishandling are found please notify the carrier and your dealer immediately.
Mains Power Supply
Fuses Sumo can be switched to operate at mains voltages of either 230V or 115V. With the switch in the 230V position, the unit will operate without performance degradation from 210V to 250V. In the 115V setting, voltages from 105V to 125V will be accepted. Do not attempt to operate the unit outside the relevant range defined above. For 100V operation, please contact your dealer.
Please note that the fuse ratings are different for each of the voltage ranges. 20mm T250mA for the 230V setting and 20mm T500mA for 115/100V.
The mains fuse is very unlikely to fail under normal use and caution should be exercised if a failure should occur. Check the mains voltage, the condition of the mains cord and the integrity of the mains supply before replacing the fuse.
Mechanical Installation
Care should be taken not to obstruct the unit’s ventilation holes. Adequate
airflow must be provided within rack cases above and below the unit to prevent overheating.
!