Thank you for choosing Aube’s non­programmable thermostat. Your new electronic thermostat is equipped with a microprocessor and proportional integral adaptive (PIA) temperature control technology for total comfort. Depending on the selected model , thi s th erm os tat h as been designed to control:
electric heating system)
AF:The Ambient temperature with Floor
TH116
Public Area
temperature limit (using a floor heating system to heat the room)
F:The Floor temperature (floor heating)
NOTE: This control module must be
mounted on a PB112 Series power base.
The thermostat has an On/Standby switch making it possible to put the thermostat in sleep mode when its use is no longer
TH113
required (e.g. summer).
Control Module Installation
Align the bracket tabs on the control module with the holes located on the power base.
Follow the same procedure for the TH116.
Control module
Power base
NOTE: Keep the thermostat's air vents clean and free
from obstructions.
NOTE: The screw cannot be removed completely.
FOR A AND AF MODELS ONLY At the rear o f the control module is a switch that has been
factory-set to the applicable temperature control.
NOTE: The AF model can be used for all temperature
control types (A, F and AF).
Note: The ambient sensor is not operational when the switch is set to I (u p ) .
GFCI Test
ߺߴߓߙߓ ߺߵߓ ࠣࠢࠪ࠘ࠥߓߓ
The GFCI monitors the electrical flow for any loss of current; if there is any loss, the thermostat will cut off power to the heating system. We reco mmend you test the GFCI immediately after installing the control module, and once a month thereafter to ensure it is operating properly. To test:
! Press the TEST button:
Successful: TEST warn­ing light is ON and power to heating system is cut off.
Unsucessful: The TEST warning light is OFF. Cut power to heating system from the main power panel and call customer service.
" When successful, reset thermostat (STANDBY/ON)
to power heating system.
NOTE: If the test warning light comes ON during normal
operation, cut power to heating system from the main power panel and hav e a n el ec tric ia n v erif y t he i ns tal lation.
At the rear of the control module are two potentiometers. These potentiometers act like a temperature lock. Even when occupants adjust the temperature using the dial on the front/rear of the control module, the potentiometers override the dial and maintain the temperature within the locked-in minimum and maximum range.
A - ambient temperature
F & AF - floor temperature limit
Use a flat tip screwdriver to rotate the pote nti om ete rs un til the notch points to the desired temperature.
Potentiometers
Notch
Remote Input
The TH113 and TH116 are equipped with a remote input which allows connection of an optional telephone controller (CT240) or any other remote control system. When a command signal is received through this input, the thermostat automatically lowers its setpoint by 3.5°C. The LED lights up to indicate the signal’s presence (except for GA and GB models).
Bypass (not available for GA and GB power base):
The TEST button can be used to bypass the signal for a 2-hour period. The LED goes off to indicate the bypass.
NOTE: When combined with a GA/GB power base, the
TEST button is used only for GFCI testing. The bypass function is not available with these power base models.
Technical Specifications
Models: TH113 and TH116 A / AF / F Setting range: 45°F, 59°F to 95°F (7°C, 15°C to 35°C) Potentiometers: minimum: 41°F to 77°F (5°C to 25°C)
maximum: 59°F to 95°F (15°C to 35°C)
Accuracy: ± 0.9°F (0.5°C) Storage: -4°F to 120°F (-20°C to 50°C)
Turn the di al to the desired temperature.
TH113: The dial is located on the front of the control
module.
TH116: The dial is located on the rear of the control
module. The min. position indicates the minimum temperature setpoint: 45°F (7°C).
Temperature
dial
TH113 TH116
Warranty
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is guar anteed against workmansh ip defects for a one year
period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product whic h has been use d under normal condition s. The warranty does not cover del ivery costs and does not apply to products poorly installed or randomly damaged following installation. This war ranty cancels and replaces any other manufacturer's express or implied warranty as well as an y other compa ny comm itm ent. AU BE Te chnolog ies Inc. cannot be held liable for related or random damages following the installation of this product. Th e defective product as well as the purchase invoice must be returned to the place of purchase or ma iled, prepaid an d insured, to the following address:
Aube Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8
If you have any questions concerning the TH113 or the TH116
thermostat, call our technical support team at:
Phone: Montreal area: (450) 358-4600
Canada / U.S.: 1-800-831-AUBE
Fax: y(450) 358-4650 Email: service@aubetech.com
Monday to Friday from 8:30 AM to 5:00 PM EST. For more information on our products, visit us at:
www.aubetech.com
01/08/03 920-113-001-00-1-A
(2823)
PB112-024T
Installation Instructions
24 V Low-Voltage Power Base
n
The PB112-024T power base can be used on any TH11x series thermostat (with the exception of the TH110 model). This low-voltage power base operates on 15-minute cycles and can be connected to a line-voltage load using a relay or directly to a 24-volt device. The PB112-024T is compatible with most relays; however, the following Aube relays are optimized for use with this power base:
RT850 solid-state relay (SSR)
RT850T solid-state relay (SSR) with built-in 24-V transformer
RC840 electromechanical relay
RC840T electromechanical relay with built-in 24-V transformer
o
Applications
Supplied Parts
n One (1) power base o Two (2) plastic anchors p Two (2) mounting screws
p
For a new installation, choose a location about 1.5 m (5 ft.)The thermostat must be installed on an inside wall facing theAvoid locations where there are air drafts (top of staircase, air
q
The installation must be carried out by an electrician and com­ply with local electrical codes.
Installation Guidelines
above the floor. heating system (except for floor heating systems). outlet), dead air spots (behind a door), direct sunlight or
concealed chimney or stove pipes (except for floor heating systems).
Installation Procedure
n Turn off power to the heating system at the main electrical panel
to avoid electrical shock.
o Wire the base according to your application. See typical wirin g
diagrams in sections 4.1 to 4.4.
p For a floor heating system installation, con-
nect the floor sensor between the S and R ter­minals.
q Secure the base to the wall using the provided
screws and wall anchors.
r Configure the switches located on the control module (if any).
Refer to the user guide.
s Install the control module onto the base. t Apply power to the heating system. u Verify the installation by checking that the heating system can be
turned on or off using the thermostat.
1.
4.1 Single SSR with Built-in Transformer
Electrical Panel
Blue
Red
Black
Heater
4.2 Multiple SSRs with External Transformer
2.
Electrical Panel
Black
3.
Heater
Heater
Red
Black
Red
External 24 V Transformer
4.3 Electromechanical Relay with External Transformer
Electrical Panel
4.
External 24 V Transformer
Heater
4.4 Hot Water Heater Valve
Electrical Panel
External 24 V Transformer
r
Maximum load: 0.5 A / 24 VAC Heating cycle length: 15 minutes Operating temperature: 32°F to 122°F (0°C to 50°C) Storage: -4°F to 122°F (-20°C to 50°C) Size (H•W•D): 124 x 70 x 23 mm (4.89 x 2.76 x 0.91 in) Wire gauge: 14 to 22 AWG
Technical Specifications
Valve
5.
PB112-024T 400-112-000-B 18/1/06 1/1