MODEL TH110A-SP-P (120 V)
LOAD
120 V LINE
120 VAC
60 HZ
B
B
W
B
W
W
W
B
OLD
THERMOSTAT
LOAD
SUPPLY
BLACK
BLACK
BLACK
WHITE
BLACK
2400 W (NI) @ 120 Vca
SUMMARY
OPTIONS SELECTION
u
At the back of the thermostat, there are three selection switches to set at your preferences.
Temperature in °C or °F, time in 12 or 24 hours and Early Start function.
u
TO SET TIME AND DAY Press on DAY, HOUR and MIN buttons to adjust time and day.
u
TO RECORD THE (COMFORT) SETPOINT TEMPERATURE Select chosen setpoint temperature by using or button. Press on
button (2 to 3 seconds) until icon appears on display.
u
TO RECORD THE (ECONOMY) SETPOINT TEMPERATURE Select chosen setpoint temperature by using or button.
Press on button (2 to 3 seconds) until icon appears on display .
O RECORD THE (VACATION) SETPOINT TEMPERATURE
T
u
To program the Vacation temperature, select the desired degree using the
buttons and press on the and buttons simultaneously
until the icon is displayed (app. 3 seconds).
u
OPERATING MODES To select an operating mode, use MODE button.
AUTO: Runs the program. or shows temperature setting
MAN: Maintains the selected temperature. or changes
and can override temporarily your programming up to the next program.
the temperature setting.
INSTALLATION
NOTE : The "Problems and Solutions" section at the end of this user's guide will
help you to correct your problems during the installation. This thermostat has been designed to operate with any installation
which has a RESISTIVE load not exceeding 2400 W (20 A) @ 120 VAC such as electric baseboards, radiant ceilings and floors, electric con­vectors, etc. It is not compatible with a low voltage controller used by a central heating system.
Electricians or experienced technicians should install the thermostat. This thermostat is designed to be used with a self-protected heating
system equipped with thermal cut off and circuit breaker.
PARTS INCLUDED
- One (1) TH110A-SP-P (120 VAC) thermostat
- Two (2) 6-32 screws
- Four (4) solderless connectors (for copper wire)
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat
clean and free from obstructions.
1) Connecting wires and mounting thermostat
Connect the rear thermostat wires to the 120 V LINE and to the load using solderless connectors for copper wires. See schematic diagram.
Push the excess wire back into the electrical box to prevent interference with the thermostat. Secure the thermostat using two (2) 6-32 screws. Once the thermostat is properly installed, return power to heating system.
BEFORE
AFTER
NOTE : All cables and connections must conform to the local electrical code.
WARNING: Special CO/ALR solderless connectors must be used when connecting with aluminum conductors.
Power-up
Set the On/Stand by switch to On.
When power is applied for the first time, the display must show the time 00:00, the room temperature and the Manual mode icon ( ). Other information might show up on the display if installation is defective or does not comply with the instructions.
NOTE : The On/Stand by switch set to Stand by
will place the thermostat in sleep mode. Ideal for summertime.
920-110-001-00-1-B 1/3
OPERATING MODES
The TH110A-SP-P has two (2) operating modes.
MANUAL ( )
This mode allows you to maintain a constant temperature in the room. 1- To activate this mode, press on Mode button to display the icon.
2- Set the desired temperature using the buttons or select the
pre-programmed , or settings. (To select the setting, press on and simultaneously.)
AUTOMATIC ( )
This mode executes your own programming. To activate this mode, press on Mode button to display the icon.
The or icon indicates which temperature setting is used. Also, the icon of the program number will be shown.
Memory back-up
In the event of a power failure, an internal circuit will maintain the programming and the time. But only the time could have to be set if power failure is more than 2 hours.
Early Start function
The thermostat is providing a built-in function enabling it to calculate the optimum time to start the heating system to achieve the desired temperature setting at the programmed time. This function could start the heating system as early as 6 hours prior to the programmed time. To enable this function, set the switch E.S. to “ON” at the back of the thermostat.
For savings to be obtained, you must lower the temperature for a period of 2 to 3 times the delay required to bring the temperature back to your comfort level.
Example : If your system takes one hour to go from your saving temperature level
to your comfort temperature Ievel, it is useless to lower the temperature for a period less than 2 to 3 hours.
a) To Program your Schedule
1- Press on PGM button to access the programming mode. 2- Press on Day button to select the day to be programmed. You can select
all days of the week by pressing on Day button for 3 seconds. 3- Press on PGM button to select program 1, 2, 3 or 4. 4- Press on Hour and Min buttons to program the time. 5- When you have completed your programming, press on Mode button
to exit this function.
b) To Erase a Program :
Select the program using PGM and Day buttons, and press on Clear button. The time field displays --:-- when the program is inactive.
c) Example 1 : Comfort period from 7:00 AM to 10:30 PM
Economy period from 10:30 PM to 7:00 AM Identical schedule for all days of the week.
1- Press on PGM button to access the programming mode. 2- Press on Day button 3 seconds to select every day of the week. 3- Press on Hour button to enter 7:00 AM, Prog. 1 ( ). 4- Press on PGM button again to select Prog. 2 ( ), and press on
Hour and Min buttons to enter 10:30 PM.
5- Press on Mode button to exit this function.
PROGRAMMING
Programming the time and day
1- Set the time using the Hour and Min buttons. 2- Set the day using the Day button.
Programming the Comfort, Economy and Vacation settings
The Comfort , Economy and Vacation settings respectively represent the temperatures that you wish to have during the day , at night or while you are away at work , or while you are away for an extended period .
To program your settings
a) To program the Comfort temperature, select the desired degree using the
(app. 3 seconds).
b) To program the Economy temperature, select the desired degree using the
(app. 3 seconds).
c) To program the Vacation temperature, select the desired degree using the
until the icon is displayed (app. 3 seconds).
d) Press the Mode button to exit this function and return to the normal
operating mode.
Schedule programming
The TH110A-SP-P allows 4 setting changes for each day of the week. There are no pre-set programs.The programs are tailored to perfectly adapt to your life style. The principle is very simple. For each day, enter the time at which you wake up (P1), the time you leave for work (P2), the time you arrive back home (P3) and the time you go to bed (P4).
buttons and press the button until the icon is displayed
buttons and press the button until the icon is displayed
buttons and press on the and buttons simultaneously
Program
1 2 3
4
Mode
Time Wake-up time Departure time
Return time Bed time
d) Example 2 : Comfort period: Monday to Friday from 6:15 AM to
Schedule/Day PROG. 1 PROG. 2 PROG. 3 PROG. 4
NOTE : It is faster to program the same schedule for every day and then modify
1- Press on PGM button to access the programming mode. 2- Press on Day button 3 seconds to select every day of the week. 3- Press on Hour and Min buttons to enter 6:15 AM, Prog. 1 ( ). 4- Press on PGM button to select Prog. 2 ( ) and Hour and Min buttons to
enter 8:15 AM.
5- Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).
NOTE : When making modifications, make sure you are in the right
To modify the Saturday and Sunday schedules:
6- Press on Day button until SA or SU is displayed. 7- Press on PGM button to select Prog. 1 ( ) and Hour and Min
buttons to enter 7:30 AM.
8- Press on PGM button to select Prog. 2 ( ) and then Clear button to
erase it.
9- Press on PGM button to select Prog. 3 ( ) and then Clear button to
erase it.
10- Press on PGM button to select Prog. 4 ( ) and then Hour and Min
buttons to enter 11:00 PM.
11- Press on Mode button to exit this function.
8:15 AM and from 5:00 PM to 10:00 PM. Saturday & Sunday from 7:30 AM to 11:00 PM.
5 PM
TUES. 6:15 AM 8:15 AM
5 PM
10 PM
WED. 6:15 AM 8:15 AM
5 PM
10 PM
6:15 AM 8:15 AM
MON. 6:15 AM 8:15 AM
10 PM
the exception days.
program.
THU.
5 PM
10 PM
FRI. 6:15 AM 8:15 AM
5 PM
10 PM
SAT.
7:30 AM
---
---
11 PM
SUN.
7:30 AM
11
---
---
PM
920-110-001-00-1-B 2/3
Loading...