The CT241 telephone controller is designed to remotely control up to four independent loads.
For example, you could connect a sprinkler system, a water heater, etc. Another example would be to connect an output to the thermo­stat’s phone interface (which requires a dry contact) to switch from Comfort mode to V acation mode and vice versa.
Loads can be activated or deactivated remotely (by telephone) or manually (on-site).
)LJXUH
ЛнкЯрЮпϫКсансдат
Any device connected to a telephone line must conform to the coun­try's standards. The CT241 telephone controller meets:
• FCC68 standards for installation on the North American network.
• FDTBR21 standards for installation on the European network.
2.1 Included Parts
• One CT241 telephone controller)
• One power transformer 120 V (North America) or 250 V (Europe)
• One 5 m (16 foot) telephone cable
2.2 Installation Procedure
NOTE: If you are usi ng an ans wering m achine, positi on the a nswer-
ing machine switch to ON befo re insta lling th e CT241. M ake sure that your answering machine answers after a minimum of 4 rings.
)LJXUH
ЌйотандйвϫИЬЮгдйаϫ ОтдпЮг
)LJXUH
ПфлдЮЬзϫДйопЬззЬпдкй
n Mount the CT241 near a telephone outlet.
NOTE: If you plan to connect a load having more that 30 volts on the
auxiliary outputs, the CT241 must be installed inside a certified elec­trical box.
o OPTIONAL. Connect your phone (or answering machine) to the
PHONE connector of the CT241.
p Connect one end of t he telephone ca ble to the LINE co nnector of
the CT241 and the other end to the telephone outlet in your home.
q Connect the loads.
The four outputs of the CT241 allow you, for example, t o activate or deactivate the light ing s ys tem , the s prin kl er sy ste m, th e w a ter heater, etc. You can also connect a thermostat’s telephone interface (which requires a dry contact) to automatically switch from Comfort mode to Vacation mode and vice versa.
NOTE: The cap acity per output is 10 A @ 240 VAC. However, to
avoid electrical shocks, the direct connection of a load exceeding 30 VAC is not permitted unless the CT241 is installed inside a certi­fied electrical box.
r When all connections have been made, connect the power
transformer to the 9 V outlet of the CT241 and the other end to the wall electrical outlet. The power indicator light is ON when the circuit is powered.
1 . Introduction
1 Power Indicator. Indicates the CT241 is pow ered on. T o turn
it off, unplug the power transformer.
2 Communication Indicator. Indicates the CT241 has
answered and is awaiting a command.
3 Ring Indicator. This indicator flashes when the phone rings. 4 Reset. This button can be used to reset the CT241 to its
default values. Seesection 3.2.
5 Manual Output Activation Button. C an be used to manually
activate or deactivate a relay.
6 Terminal Board. See section 2.
2. Installation
CT241 Telephone
Controller
Installation Instructions and User Manual
400-241-001-A
NOTE: The CT241 will automatically hang up if no key is pressed
during the 30 seconds following the CT241 answering a call.
Default values: access code (1234), number of rings (4)
BEGIN A SESSION (without answering machine)
BEGIN A SESSION (with an answering machine)
ENTERYOURACCESSCODE
OUTPUT S TATUS/MOD IFY STATU S
MODIFY THE ACCESS CODE
MODIFY THE NUMBER OF RINGS
SKRQHRQO\
END SESSION
3.1 Manual Output Activation Buttons
You can switch a relay status by pressing the corresponding input’s button directly on the CT241.
This function is not accessible while the CT241 is answering a tele­phone call.
3.2 Reset Operation
Insert a pointed object (e.g. paper clip) in the hole located under the Reset light. The light will flash 3 times to indicate that the CT241 has been reset:
• number of rings: 4
• access code: 1234
• relays’ status: open
Power supply: 9 VAC / 60Hz (50 Hz Europe) Outputs: Four SPST with the following capacity:
• 5 A / 30 VAC inductive / Power Factor: 0.4
• 10 A / 30 VAC resistive (if installed in a certified electrical box)
• 10 A / 240 VAC resistive (if installed in a certified electrical box)
• 1/2 HP / 120 VAC motor (if installed in a certified electrical box)
• 1 HP / 240 VAC motor (if installed in a certified electrical box)
Protection: Class II Access code (default): 1234 Number of rings (default):4 rings Memory protection: In case of power failure, access code and out-
put status are protected.
Phone certification standard:
• FDTBR21: European telephone network
• FCC68: North American telephone network
Approvals:
• c UL us (North America)
• CE (Europe)
Dimensions (H W D): 2.7 x 5.4 x 1.2 in. (69 x 137 x 31 mm)
AUBE TECHNOLOGIES INC. THREE (3) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a three­year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and with­out charge, any defective prod uc t w hi ch has be en u se d u nde r normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation.
This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commit­ment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.
The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the nearest shipping address.
3. Operation
Dial your phone number Wait for the number of rings... CT241 answers
Dial your phone number Let it ring once and hang up Wait 10 seconds ... Dial your phone number again within the next 30 seconds
CT241 answers (1
st
ring)
Enter your 4-digit access code (default: 1234)
Accepted
Error
Press the output’s corresponding number for status
Deactivated
(open)
Press to change its status
Activated
(closed)
Press
Enter your new 4-digit access code
Enter the access code again
Accepted
Error
Press Enter the number of rings after
which the CT241 will answer (between 1 and 9)
x the number of
selected rings
Press to end the session
4. Technical Specifications
5. Warranty
705 Montrichard Saint-Jean-sur-Richelieu Quebec, Canada J2X 5K8
Tel.: 1 (450) 358-4600 Toll Free: 1-800-831-AUB E Fax: 1 (450) 358-4650
service@aubetech.com
10 Ampère Street 95500 Gonesse France 33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19 advaube@comintes.com
For more information on our products, visit us
at: www.aubetech.com
29/10/2003 400-241-001-A
Loading...