This air conditioner design has been certified by the Canadian
Standards Association for installation in recreation vehicles.
SERVICE CALLS & QUESTIONS
Location and phone numbers of qualified Service Centers can
be found at our website http:/www.atwoodmobile.com or call
866-869-3116 to locate a Service Center.
WARNING: It is important that this installation
manual is read and understood before
installation. The unit must be installed by a
qualified service technician. Failure to properly
install the unit or attempting to modify it in any
way can be extremely hazardous and may
result in property damage and personal injury
and will void the warranty.
BEFORE INSTALLATION
Ensure that the installation instructions have been
properly read and understood.
Installation must conform to Local wiring codes and
regulations or, in the absence of local codes, the
Standard on Recreational Vehicles, NFPA 1192. and
National Electrical Code NFPA 70.
DO NOT attempt to modify or add components to the
installation procedure.
This equipment must only be serviced by a licensed
refrigeration mechanic to maintain warranty
coverage.
If your installation varies from the method outlined
please contact Atwood Mobile Products, LLC for specialty
advice.
Atwood will not be held responsible for problems
relating to incorrect or improper installation
methods.
AC IOM 3/01/2013 rev 1 1
GENERAL INFORMATION
I.
PURPOSE
This Atwood AirCommand air conditioning unit is designed
for installation on the roof of a recreational vehicle to
provide cooling with AC-1351 models and
cooling/heating with AC-1501 models.
-The roof must be capable of supporting the weight of the
unit which is 86lbs (39Kg).
-The absolute minimum thickness of the roof must not be
less than 1 inch (25mm).
-The maximum thickness of the roof must not exceed
5 inches (125mm).
-Trimming of the ductwork and/or bolts may be necessary
depending on the roof thickness
It is important that the unit is installed properly and
according to the recommended guidelines.
II.
ENSURING EFFECTIVE OPERATION
The effectiveness of the air conditioner is dependent on
several factors e.g. size and heat load of the vehicle. When
an Atwood unit is installed Atwood assumes that the
vehicle is well insulated with 1 inch (25mm) foam minimum
in all wall s and roof, that the windows are of moderate size
(preferably double glazed) and the roof vents are airtight
when closed. Other methods of reducing heat load include:
-Closing all doors, hatches, windows and blinds
-Position the vehicle so if porch is used, it will face the sun
and protect the windows from direct radiation.
-Turning off appliances that might increase the heat load
-Ensuring the vehicle is parked in a shaded position.
In periods of extreme high temperature it is recommended
to start the air conditioner earlier in the morning to greatly
improve its ability to cope with the expected high heat load.
III.
CONDENSATION
In areas of high humidity, the humid air within the RV will
cause “sweating” or condensation in parts of the unit as the
humid warm air contacts the colder air discharge system. If
this occurs please ensure the following:
-Closing all doors, hatches, windows and blinds to limit the
ingress of warm humid air
-
Avoid running the inside fan on LOW or AUTO in such
conditions. Running the fan on HI fan speed will result in
higher airflow and reduce the tendency to have
condensation form.
INSTALLATION PARTS LIST
MAIN COMPONENTS
1)
Atwood AirCommand
Rooftop Air conditioner
2)
Roof Seal Gasket 2 Pcs
3)
Adapter
4) Extension Duct
5)
Brace Assembly
6) Plenum
7) Plenum Filters x2
FITTINGS & FIXTURES
8)
M8 Bolts x 4
9) Hold Down Bars x 4
10)
Plenum Cover Screws x 4
11)
Self Tapping Screws x 6
INSTALLATION POSITION
Minimum 1” clearance
from side grilles to any
obstruction
AC IOM 3/01/2013 rev 1 2
Minimum 8” clearance from
rear grilles to any vertical face,
4” to any 45 degree face.
Unit Installation (Non-Ducted)
CAUTION
WARNING
Before beginning, mark out the position of the
unit considering the following important
requirements:
-
The air conditioner should be situated as
centrally as possible on the vehicle, to ensure
even air distribution.
-
The front of the unit MUST face the direction of
travel; failure to follow this instruction will result
in damage to the condenser fans.
-
If the vehicle is over 23’ in length, or has an
unusually high heat load (see General Operating
Information section regarding expectations
about insulation etc.), Atwood recommends 2 or
more units to cool effectively.
-
When considering the installation position
remember to check for clearance around the
plenum inside the vehicle.
-
Avoid an installation position where a
bulkhead, cupboard or light fitting could interfere
with the discharge air flow from the plenum.
It is important that the unit is never more
than 5° from the horizontal and the rear of
the unit should never be higher than the front.
-
Contact Atwood if your installation differs
significantly.
ASSESS ROOF STRENGTH
-
The roof members MUST be strong enough to
support the weight of the unit 99 lbs (45kg)
without any roof deflection that will cause
“pooling” of water around the unit. Contact your
RV manufacturer to confirm the max load the
roof is able to handle. If in any doubt consider
the use of an external “H” frame.
-
If the roof does not have an existing hole
one must be cut. Cut from the roof then use the
roof hole as a guide to cut through the ceiling.
Contact your RV manufacturer for the best
method to cut through the roof.
-
The square hole in the roof (14” x 14”) MUST
be boxed up with minimum 3/4 inch square
timber to provide a structure strong enough to
withstand the compression of the installation
bolts. This is also to ensure that air in not drawn
from the roof cavity (Fig 3 & 4). Remember to
leave access for wiring.
-
Longitudinals MUST be fixed securely to the
transverse roof members to transfer load
(see Fig 3).
There may be electrical wiring located between the roof and
ceiling. Ensure that power is properly disconnected at the
supply (mains and/or battery). Failure to do so may result in
personal injury or death
TIP:
Always use crawl boards across the roof to avoid damage
POSITION UNIT ON ROOF
-
Remove the air conditioner from the carton.
-
Position the unit over the gasket so that
the corners of the square hole in the RV roof line up with the corners
of the square hole underneath the air conditioner (Fig 6). TIP:
one person inside the RV looking through the hole while the other
is on the roof adjusting the position of the unit.
Have
AC IOM 3/01/2013 rev 1 3
CAUTION
WARNING
The unit weights approximately 86lbs
(39kg). Ensure a two person lift or use
a mechanical hoist to avoid the risk of
injury.
-
DO NOT slide the unit on the roof, this may
damage the gasket and result in leaks.
-
Four M8 mounting holes on the chassis
underneath the air conditioner will line up with
the corners of the square roof hole (Fig 7).
ATTACH ADAPTER TO UNIT
-
Screw adapter to the underside of unit with
the 4 screws provided (this step can also be
done before the unit is positioned on the roof
but be careful not to damage while fitting)
-
The adapter will only fit one way, be careful
to ensure adapter is positioned correctly
(Fig 8) and avoid affixing back to front.
Ensure that power is properly
disconnected at the supply (mains
and/or battery). Failure to do so may
result in damage to the unit and
personal injury or death.
Fig 6- Position the unit over the roo f gasket and set down gently.
Position the unit so the 4 mounting holes (circled) line up with the
corners.
Fig 8: Shows positioning of adapter to be attached to underside of unit. Ensure adapter is
mounted the correct way, screw holes will not line up if attached out of phase.
CONNECT ELECTRICAL SUPPLY
Installation must conform to local wiring codes
and regulations or, in the absence of local codes, the Standard on
Recreational Vehicles, NFPA 1192. and National Electrical Code
NFPA 70.
-
Connect AC power supply to wire leads from unit
Note:
Brown wire from rooftop unit to Black or Red from customer – AC Hot
Blue wire from rooftop unit to White wire from customer – AC Common
Yellow/Green wire from rooftop unit to Green wire from customer - Ground
Note: Atwood strongly recommends the use of the Molex connector
described on the next page.
AC IOM 3/01/2013 rev 1 4
COC-1 Self Contained Power Connector Installation Instructions
Wire Range
AWG
Order
No.
Optional
Hand Tool
Optional Bench
Mount Tool
Optional Bench
Arbor Press
Housing
Color
12-14
19045-1000
(COC-1)
19285-0074 N/A
64006-0200
White
For 2 Wire Cable With Ground Applications
The 2-circuit-with-ground connectors will splice non-metallic-sheathed cable in the following wire ranges and types:
Self Contained Connector 2 Circuit with ground for Solid Wire
FIG. 2
Reference Information
UL File Number: E182087,
CSA File Number: LR18689-C53
NEC Article: 550, 551, and 545
HUD Section: 3280.801
Current: 20A,Voltage: 300V
Installation Procedure:
1. Carefully strip and prepare the wires to the configuration as shown in Figure 1 using helpful
hints shown in photographs of Figure 2.
2. Hold the clear strain relief cover with bottom facing upward as shown in Figure 3.
3. Lay wire into locator slots, making sure the black wire is placed into the polarization slot as
shown in Figure 3.
4. Press the cable sheath into the integral strain relief slot as shown in Figure 3. Trimming of
ground wire and possibly others will be necessary. Wires must not extend beyond the
locators as shown in Figure 4!
5. While holding the strain relief cover, position the housing’s hinge posts into the hinge slots
and press down until both lock into place as shown in Figure 4.
6. Close the strain relief cover and housing by hand. Place the connector assembly into Molex
tool (preferred) as shown in Figure 5. Squeeze the tool until the connector bottoms out and
the locking latches engage on both sides. OR alternately, squeeze the top and bottom
closed with tongue and groove pliers as shown in Figure 5.1. Pliers must be a minimum of
10" long. Squeeze
firmly on both sides, squarely across the connector between ribs A and B to ensure wires seat
completely into slots.
7. Inspect the connector to ensure the wires have been properly engaged into the housing
assembly contacts. A properly terminated wire is fully seated into its proper slots with no
significant bow of the cover. If the wires extend past the insulations tops, the wires must be
re-terminated with a NEW CONNECTOR. Once the cover has been closed the connector
cannot be re-used. Failure to comply with this procedure may result in the failure of the
connector.
8. Mating and un-mating the completed connector is illustrated in Figure 6.