atwood 1H2C User Manual

LITERATURE NUMBER MPD 31492
hydro flame™
/9<
Atwood Mobile Products llx: 1120 North Main Street • Elkhart, IN 46514 PHONE: 574-264-2131 FAX; 574-262-25 50 INTERNET: http://www.atwoodmobile.com
ENGLISH, FRANÇAIS (et Canada) «Installation «Operation
THIS THERMOSTAT HAS BEEN DESIGNED TD DPERATE STANDARD AIR CONDITIDNING UNITS IN CONJUNCTION WITH A RV FURNACE.
Atwood'
Digital Thermostat
FOR STANDARD FURNACES
& A/C SYSTEMS
Effective 9/21/04
Operating Voltage Current Consumption at 12V0C
Operating Temp.....................................-40F to +185F
Room Temp. Range ................................+55F to +90F
Room Temp. Display Range Thermostat Accuracy
Switching Capability A/C............................up to 24 VAC
uispiay Kioaesei
THERMOSTAT INSTALLATION
Thermostat js very sensitive, handle
WITH CARE AT ALL TIMES.
Locate thermostat 48” to 54" above floor on an INTERIOR Wall. Pick a dry area where air circulation is good.
EXTERIOR wall location must have a
3/4" spacer between thermostat and exterior wall.
1. Be sure all electrical power has been disconnected from the air conditioner, furnace and the power supply.
2. Do not install the thermostat where there are unusual heating conditions: such as direct sunlight, heat producing appliances (television, radio, wall lamp, etc.) or a furnace or air conditioner supply register.
3. AHACHING THE WALL THERMOSTAT. Separate the thermostat body from the sub-base by gently squeezing the top and bottom, connecting wiring per requirements. Attach thermostat sub-base to the wall at desired mounting location.
SPECIFICATIONS
...............................
..........................................
9VDC to 18VDC
........................
....................
•Note: Move jumper to positions 3 and 4 for RVP Unit. Discard jumper for Dometic”.
PMtSW MM
100mA
+35F to +99F
t/- 1F
(max. 2 AMPs)
SLIDE SWITCH
LEFT RIGHT
OFF
COOL
OFF HEAT FAN
COOL
OFF HEAT
COOL
OFF HEAT
COOL
HEAT FAN
SCROLL ORDER OF
DISPLAYED MODES
HI
Furnace Operation
Furnace cycles to satisfy set point.
OPERATION
Air Conditioner Operation
Air conditioner automatically switches compressor and high and low speed fan when cycling to satisfy set point.
set point.
LO Air conditioner compressor and low speed fan cycle to satisfy
set point.
Fan Operation
Air conditioner fan runs at low speed to circulate air.
LO
Off
No operation occurs.
FAN
FAN
AU
HI Air conditioner compressor and high speed fan cycle to satisfy
HI Air conditioner fan runs at high speed to circulate air.
OF
WIRING REQUIREMENTS FOR ATWOOD THERMOSTAT