Appendix A Standards and compliances ............................................i
FCC standards: radio and television interference
Canadian standards
European standards
Appendix B Accessories .......................................................................iii
Appendix C SCSI adapter selection guide ..........................................iv
Appendix D SAS adapter selection guide ...........................................v
Appendix E Safety, warranty, contacts ................................................vi
Safety
ATTO Technology, Inc. limited warranty
Page 4
1 ATTO provides Fibre Channel solutions
The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and
scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching,
backup and data management. Specifically designed to enhance the functionality of third party fabric
hardware and software, Celerity FC products are the industry-leading platform for storage connectivity.
Celerity FC-44ES Adapter
The Celerity FC-44ES uses PCI Express Interconnect
and 4-Gigabit Fibre Channel to provide 4-Gb FC
speeds of up to 800 MB/sec. per channel. The FC44ES supports high-definition video, rich content
databases and other high bandwidth environments.
The FC-44ES uses PCI Express, a serial, high-speed
connection that supports aggregate throughput up to 4
GB/sec. (x8 PCIe) full-duplex. With software
compatible with existing PCI and PCI-X products, the
FC-44ES uses the same device drivers as other
Celerity FC family products, simplifying installation
and support.
Hardware specifications
• 4 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Supports exclusive ATTO Advanced Data
Streaming (ADS) Technology
FDMI and WMI
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
Interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI Express to PCI/PCI-X Bridge spec 1.0
Environmental & physical specifications
• Conforms to PCI standard height, half length
form-factor specifications
• Length: 6.525 inches
• Height: 3.81 inches
• Operating temperature: 0-45ºC (32-113ºF)
• Storage temperature: -40 to 70ºC (-40 to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 12V@ 2.1A (max.)
• 3.3V @ 3.0A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for
each channel
• 4 pluggable optical LC SFP transceivers
included
Software specifications
• Windows XP, 2000, Server 2003 and Vista
• Mac OS X (10.4.x, 10.5.x)
• Red Hat Linux
• SUSE Linux (2.6 kernel)
(2.4 and 2.6 kernel)
1 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 5
Celerity FC-42ES Adapter
The Celerity FC-42ES is a dual-channel host adapter
providing port density for Enterprise server and
workstation applications. With 4-Gb FC speeds of up
to 800 MB/sec. per channel, the FC-42ES supports the
most demanding application requirements.
Additionally the FC-42ES takes advantage of the latest
in host interconnect technology, PCI Express, a serial,
high-speed connection that supports aggregate
throughput up to 4 GB/sec. (x8 PCIe) full-duplex. The
FC-42ES is software compatible with existing PCI and
PCI-X products using the same device drivers as other
Celerity FC family products, simplifying user
installation and support. It is backward compatible
with existing 2-Gb and 1-Gb Fibre Channel
infrastructure, protecting existing technology.
Hardware specifications
• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• Storage temperature: -40º to 70ºC (-40º to
158ºF)
• Relative humidity: 5 to 95% non-condensing
• 100 lf/m (minimum) airflow recommended
• Conforms to PCI half height, half length formfactor specifications
• 12V@ 04A (max.); 3.3V @ 1.5A (max.)
• Length: 5.6 inches
• Height: 2.712 inches
• RoHS compliant
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for
each channel
• 2 pluggable optical LC SFP transceivers
included
Software specifications
• Windows XP, 2000, Server 2003 and Vista
• Mac OS X (10.4.x, 10.5.x)
• Red Hat Linux
• SUSE Linux (2.6 kernel)
(2.4 and 2.6 kernel)
2
Page 6
Celerity FC-41ES Adapter
The Celerity FC-41ES is a single-channel host adapter
providing support for the most demanding application
requirements. With 4-Gb FC speeds of up to 800
MB/sec. per channel, the FC-41ES is a cost effective
connectivity solution for environments requiring
maximum throughput.
The FC-41ES also takes advantage of the latest in host
interconnect technology: PCI Express, a serial, highspeed connection that supports aggregate throughput
up to 2 GB/sec. (x4 PCIe) full-duplex. The FC-41ES is
software compatible with existing PCI and PCI-X
products using the same device drivers as other
Celerity FC products, simplifying user installation and
support. It is backward compatible with existing 2-Gb
and 1-Gb Fibre Channel infrastructure, protecting
existing technology investments.
Hardware specifications
• 1 Fibre Channel port
• 4-Gigabit FC data transfer rates
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Features exclusive Advanced Data Streaming
(ADS) Technology
FDMI and WMI
Host bus specifications
• x4 mechanical and x4 electrical PCI Express
interconnect
• Supports PCI Express Base Spec 1.0a and CEM
Spec 1.0a
• Supports PCI Express to PCI/PCI-X bridge spec
1.0
Environmental & physical specifications
• Conforms to PCIe low profile form factor
specifications
• Length: 5.600 inches
• Height: 2.712 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to
158ºF)
• Relative humidity: 5 to 95% non-condensing
• 100 lf/m (minimum) airflow recommended
• Power: 12V@ 0.4A max; 3.3V@1.0A max.
• RoHS compliant
External connectivity
• Easy-to-install full height connection bracket
• External LEDs for on-line and speed status
• Pluggable optical LC SFP transceiver included
Software specifications
• Windows XP, 2000, Server 2003 and Vista
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4.x, 10.5.x)
3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 7
Celerity FC-41EL Adapter
The Celerity FC-41EL is a single-channel host
adapter. With 4-Gb FC speeds of up to 800 MB/sec.,
the FC-41EL supports the most demanding application
requirements.
The FC-41EL takes advantage of the latest in host
interconnect technology, PCI Express, a serial, highspeed connection that supports aggregate throughout
up to 2 GB/sec.full-duplex. The FC-41EL is software
compatible with existing PCI and PCI-X products
using the same device drivers as other Celerity FC
family products, simplifying user installation and
support. It is backward compatible with existing 2-Gb
and 1-Gb FC infrastructures, protecting existing
technology investments.
Hardware specifications
• 1 Fibre Channel port
• 4-Gigabit data transfer rate
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation between 4Gb, 2-Gb and 1-Gb Fibre Channel
• Supports initiator and target modes
• Supports Windows® FDMI and WMI
• Supports exclusive ATTO Advanced Data
Streaming (ADS™) technology
Host bus specifications
• x4 mechanical and x4 electrical PCIExpress
interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
Environmental & physical specifications
• Conforms to PCIe low profile form factor
specifications
• Operating temperature: 0 to 45º C (32-113º F)
• Storage temperature: -40 to 70ºC (-40 to 158º F)
• Relative humidity: 10 to 90% non-condensing
• 100 lf/m (minimum) airflow recommended
• Conforms to PCI Express low-profile form-factor
specification
• 12V @ 0.5A (max)
• Length: 5.600 inches
• Height: 2.712 inches
• RoHS compliant
External connectivity
• Easy-to-install full and low-profile connection
plates
• External LEDs for on-line and speed status
• A pluggable optical LC SFP transceiver included
Software specifications
• Windows XP, 2000, Server 2003 and Vista
• Mac OS X (10.4.x, 10.5.x)
4
Page 8
Celerity FC-42XS Adapter
The dual-channel Celerity FC-42XS host adapter
provides the highest available throughput for Fibre
Channel applications while protecting technology
investments via backward compatibility with existing
infrastructure.
With speeds of up to 800 MB/sec. per channel, the FC42XS is capable of supporting the most intensive data
applications.
To ensure a smooth transition path, the FC-42XS
leverages the existing Celerity FC software hardware
architecture, allowing ATTO to deliver industryleading quality and stable software architecture.
Hardware specifications
• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Includes exclusive ATTO Advanced Data
Streaming (ADS) Technology
FDMI and WMI
PCI bus specifications
• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only
Environmental & physical specifications
• Conforms to PCI low profile form factor
standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to
158ºF)
• Relative humidity: 5 to 95% non-condensing
• 3.3V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for
each channel
• 2 optical LC SFP transceivers included
Software specifications
• Windows XP, 2000, Server 2003 and Vista
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4x, 10.5x)
5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 9
Celerity FC-41XS Adapter
The single-channel Celerity FC-41XS provides speeds
of up to 800 MB/sec. using full 4-Gigabit Fibre
Channel performance while being fully backwardcompatible with existing 2-GB and 1-Gb Fibre
Channel infrastructure, protecting existing technology
investments. It is capable of supporting the most dataintense applications.
Hardware specifications
• 1 Fibre Channel port
• 4-Gigabit data transfer rates
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Includes exclusive ATTO Advanced Data
Streaming (ADS) Technology
FDMI and WMI
PCI bus specifications
• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only
Environmental & physical specifications
• Conforms to PCI low profile form factor
standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to
158ºF)
• Relative humidity: 5 to 95% non-condensing
• 3.3V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status
• Optical LC SFP transceiver included
Software specifications
• Windows XP, 2000, Server 2003 and Vista
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4.x, 10.5.x)
6
Page 10
Celerity FC-21PS Adapter
The Celerity FC-21PS Fibre Channel host adapter
provides a single 2-Gb Fibre Channel connection from
host devices to the Storage Area Network (SAN)
fabric.
The FC-21PS supports the leading operating systems,
providing a single solution for all connectivity needs.
As with all Celerity FC products, the FC-21PS is
designed for high-quality data transmission, ensuring
that critical information is delivered correctly the first
time to reduce fabric traffic and improve overall fabric
efficiency.
Hardware specifications
• 1 Fibre Channel port
• 400 MB/sec. throughput full-duplex
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
2003 and Vista support
Linux (Red Hat, SUSE) driver
Macintosh OS X driver
Novell Netware support
Solaris support
Free BSD
RoHS compliant
1 Performance ceiling is constrained by 133 MHz PCI-X bus transfer speed
2 Backward compatible to 32-bit and 33 MHz PCI; FC-21PS is 3.3V/5V Universal
3 ATTO ExpressStripe for OS X available; Express Power Center and other software RAID supported for Windows
4 FC-41EL 32-bit support only
• •
• • • • • •
• •
• •
• •
• • • • •
ES only
ES only
ES only
ES only
• • •
• •
• •
• •
2
Celerity
FC-21PS
64-bit
133 MHz
500m@1-Gb
300m@2-Gb
2
8
Page 12
2 Fibre Channel is a key technology for storage
Fibre Channel is a serial communications technology designed to transfer large amounts of data among
a variety of hardware systems over long distances. It is a key technology for applications that require
shared, high bandwidth access to storage.
Fibre Channel provides a logical, point-to-point,
serial channel for the transfer of data between a
buffer at a source device and a buffer at a
destination device. It moves buffer contents from
one port to another, without regard to the format
or meaning of the data so different upper level
protocols are able to run over Fibre Channel
hardware.
The Fibre Channel architecture is structured as a
hierarchical set of protocol layers. Defined within
these layers are rules for signal interfaces, serial
encoding and decoding, error control, frame
format and communications protocols.
Glossary
Some terms used in the Fibre Channel industry are defined below. More information is available through
the ATTO Technology website
(
www.fibrechannel.com
(
www.snia.org
)
, and the Fibre Channel Consortium (
TermDefinition
ANSIAmerican National Standards Institute
arbitrateprocess of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop
arbitrated loopa loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can
auto negotiationhardware senses and automatically responds depending on configuration
BERBit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent
bitsmallest unit of data a computer can process: a single binary digit with a value of either 0 or 1
busa collection of unbroken signal lines used to transmit information from one part of a computer
bytean ordered set of 8 bits
channela point-to-point link which transports data from one point to another
CPUCentral Processing Unit: the portion of the computer that actually performs computations
CRCCyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
destination
address
device drivera program that allows a microprocessor to direct the operation of a peripheral device
DMADirect Memory Access: a way to move data from a storage device directly to RAM without using
DMA bus masterallows a peripheral to control the flow of data to and from system memory by block as opposed to
)
, Cern (
(
www.attotech.com
www.cern.ch
at the same time
communicate at one time; low-cost solution which may or may not use hubs and switches
system to another; taps on the lines connect devices to the bus
and transmitted data; if no error has occurred during transmission, the CRC for both received and
transmitted data should be the same
a value in the frame header of each frame which identifies the port in the node where the frame is
being sent
the CPU’s resources
allowing the processor to control the data by bytes (PIO or programmed I/O)
)
, the Fibre Channel Industry Association
)
, the Storage Area Networking Industry Association
www.iol.unh.edu/consortiums
, click on FC)
.
9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 13
TermDefinition
fabrica Fibre Channel switch of two or more Fibre Channel switches interconnected to physically
transmit data between any two N_Ports on the switch or switches
FCFibre Channel
F_porta port in the Fibre Channel fabric where a N_port may attach
FL_porta port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop
framean indivisible unit for transfer of information in Fibre Channel
frame headerthe first field in the frame containing the address and other control information about the frame
full-duplexa communication protocol which allows transmission in both directions at the same time
half duplexa communication protocol which allows transmission in both directions, but only one direction at a
time
hosta processor, usually a CPU and memory, which communicates with devices over an interface
initiator devicea component which originates a command
L_porta port in an arbitrated loop, either a NL_port or a FL_port
LEDLight-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
are used as indicator lights on all sorts of electronic devices
LUNLogical Unit Number: an identifier for a logical unit (0-7)
multi-mode fiberan optical fiber which can carry several beams of light at once
N_porta port attached to a node used with point to point or fabric configurations
NL_ porta port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration
originatoran initiating device; a component which originates a command
parity checkinga method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error
message occurs if the sum is not correct
PCIPeripheral Component Interconnect. Allows peripherals to be connected directly to computer
memory, bypassing the slower ISA and EISA busses
point-to-pointa topology where two ports communicate
portan access point in a device: see N_port, NL_port, etc.
port addressalso port number; the address, assigned by the PCI bus, through which commands are sent to a
host adapter board
port numbersee port address
receiverthe ultimate destination of data transmission; a terminal device
scatter/gathera device driver feature which allows the host adapter to modify a transfer data pointer so that a
single host adapter can access many segments of memory, minimizing interrupts and transfer
overhead
SCSISmall Computer Systems Interface: a processor-independent standard for system-level interface
between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers,
scanners, etc.
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source
topologylogical layout of the parts of a computer system or network and their interconnections
transceivera transmitter/receiver module
transfer ratethe rate at which bytes or bits are transferred, as in megabytes or gigabits per second
10
Page 14
3 Installing and updating drivers
Before installing your Celerity adapter, you must configure your system to recognize and use it by
installing drivers for your operating system.
Configure your system to recognize and use your
Celerity adapter by
• installing drivers for your operating system
• updating the adapter firmware if necessary (refer
to Updating hardware flash
Note
If you already have one or more Celerity
adapters installed and you are installing
additional adapter(s), you do not need to
perform any of these procedures unless you
are updating a previously installed driver.
on page 22)
Specialized configurations
Some specialized applications may benefit from
modification of adapter settings. The ATTO
Utilities Installation and Operation Manual
provides detailed information on using ATTO
Technology configuration utilities found on the
ATTO Utilities CD or downloaded from the
ATTO website. For best performance, use the
most recent device driver and flash version.
Verify the version based on your operating
system.
Windows:
from the ATTO Utilities CD, or download it from
www.attotech.com
string during system boot or look in the
Manager
Use the ATTO Configuration Tool
, or view the adapter boot
Device
.
ATTO Celerity adapters ship with the latest
firmware installed.
The Celerity FC Installation CD shipped with
your adapter contains the latest driver.
The Installation CD automatically starts when
inserted in the system CD-ROM drive. Navigate
the easy-to-use HTML-based menu to find the
driver that you want to install.
If the CD does not automatically start, open the
CD and click on
Note
Windows NT is only supported with Celerity
driver version 1.31 or earlier. If you are using
Windows NT, contact your service
representative.
Mac OS X
autorun.bat
.
: Use the ATTO Configuration Tool on
the ATTO Utilities CD, or download it from
www.attotech.com,
or use the Apple System
Profiler.
Linux
: Use the ATTO Configuration Tool on the
ATTO Utilities CD, or download it from
www.attotech.com
examine
/proc/scsi/celerityfc/X
, or to find the driver version,
, where X is the
adapter’s host number.
Windows 2000/XP/Server 2003/Vista
Five procedures are described below. Review
each thoroughly to ensure that you are using the
one that best fits your needs. If you have one or
more Celerity FC adapters installed in your
system and you are installing additional
adapter(s), you do not need to perform any of
11 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
these procedures unless you are updating a
previously installed driver.
The Celerity FC Installation Disk can be the
Installation CD shipped with your adapter, a
folder containing the latest downloaded and
expanded driver, or a Celerity FC installation
floppy disk.
Page 15
Upgrading an existing Celerity FC driver
1Log on to Windows as the System
Administrator.
2Insert your Celerity FC Installation Disk and run
autorun.bat
3In Windows Drivers, select your operating
system version.
4Click on Install Driver.
Adding a Celerity FC adapter to an
existing installation
Note
Complete this installation procedure before
attaching any devices to the adapter.
1Complete the steps in Updating hardware flash
on page 22 to pre-install the driver.
2Close Windows and turn off power to your PC
when Setup prompts you to do so.
3Install your new Celerity FC adapter into an
available PCI expansion slot.
a. If the Celerity FC adapter is replacing
another adapter in the system, disconnect
the FC cables from the adapter and
remove the adapter from the system, or
move the Celerity FC adapter to the PCI
slot that the previous adapter occupied.
b. Attach the appropriate FC cables to the
Celerity FC adapter.
4Close the computer chassis
5Turn on the power and restart Windows.
6During the boot process, Windows detects your
Celerity FC adapter and the Found New Hardware Wizard is displayed.
Follow the directions in the Found New Hardware Wizard, selecting the default
settings for each adapter channel.
7Insert the Celerity FC Installation disk when
asked to do so.
8When adapter installation is complete, the
Found New Hardware Wizard displays an
ATTO Phantom Device for each channel. Use
the wizard default settings to complete the
installation.
Creating a boot disk
Note
The procedure described below does not
apply to Windows Server 2003 for Itanium
systems because the Celerity FC driver does
not support boot functionality on Itanium
systems.
1Start Windows text mode setup as found in the
instructions provided with Windows.
2Press F6 when Windows Setup, displays. The
setup program displays a prompt in the status
window on the bottom left of the monitor. Setup
continues to load files after you press F6.
3A new window displays instructions to specify
additional mass storage devices. Press S to
install the ATTO Celerity as a storage device.
4Insert the Celerity FC installation diskette in
drive A and press Enter.
5A screen displays a list of Celerity FC adapters.
Select your adapter and press Enter.
6Windows Setup loads the files from the floppy
and then displays the screen described in Step
2. The ATTO Celerity FC device should now be
listed as detected.
7Repeat steps 2
supplied driver installation disks.
8After all other drivers have been processed,
press Enter and proceed with the rest of the
Windows installation procedure.
Note
When Windows begins copying files to your
hard disk, a display prompts you to insert the
Celerity FC installation disk and any other
vendor-supplied disks you used during
custom installation. This is normal. The first
time you inserted the disks, Windows loads
the drivers into memory; the second time you
insert the disk(s), Windows copies the driver
to your hard disk.
to 6 for any other vendor-
12
Page 16
Creating a Celerity FC installation floppy
Note
You must have a floppy disk with the Celerity
FC driver software to install a fresh copy of
the Windows OS onto a disk attached to a
Celerity FC adapter.
1Insert the Installation CD into a CD-ROM. The
installation starts automatically.
If the Celerity FC installation does not start,
navigate to the root of the CD and run
autorun.bat
2Select Windows Drivers from the items on the
left side of the screen.
3Select the appropriate CPU-based operating
system from operating system choices.
4Select Create Miniport Driver Diskette or
Create StorPort Driver Diskette for the
desired operating system.
5Follow the instructions for creating the floppy
disk.
Creating a floppy disk from a download
1Download the latest driver software from the
2The download is a self-extracting executable
3Navigate to the folder with the desired Celerity
4Run makedisk.bat and follow the instructions
Mac OS X driver installation, update
ATTO website,
that expands the driver software package. Run
the self-extracting executable and select a
folder to place the expanded software package.
FC driver.
Note
The expanded software package contains a
Miniport driver and may contain a StorPort
driver. The Celerity FC Windows Miniport
driver is in the base directory of the
expanded software package. The Celerity
FC Windows StorPort driver is in the
StorPort subdirectory.
for creating the floppy disk.
www.attotech.com.
1Extract the latest version of the device driver file
to your desktop.
2Double click the installer icon and follow the on
screen prompts.
Linux driver installation, update
Note
You must have kernel header files for the
appropriate kernel installed.
You must be logged in as
1At the command prompt type rmmod
celerityfc
root
.
3Reboot your system for the changes to take
effect.
2Download the appropriate version of the device
driver from the ATTO website.
3At the command prompt, extract the file using
the command tar -xfz <filename.tgz>
4Enter the directory created in the above step
and type make install to overwrite any
previously-installed driver.
5Start the driver by typing modprobe celerityfc
13 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 17
14
Page 18
4 Hardware installation
You need a basic understanding of Fibre Channel before installing the Celerity FC host adapter. Please
refer to
Fibre Channel is a key technology for storage
on page 9 for a list of related websites.
CAUTIONCAUTION
Back up your system data before changing
or installing any hardware.
System requirements
The Celerity FC host adapter package contains the
host adapter, the ATTO Utilities CD and a
warranty and registration card. If any of these
items are missing, contact your ATTO authorized
sales representative.
To install and use the Celerity Fibre Channel host
adapter you need
• A computer with an available PCI, PCI-X or PCI
Express expansion slot
• The complete Celerity FC host adapter package
Fibre Channel address
Celerity FC adapters are configured with a unique
address designated by the Institute of Electrical
and Electronic Engineers. The WorldWide Port
Name (WWN) and Node Name are the two
components of the address assigned to Fibre
Channel products. This address, stored in flash
memory, allows the system to recognize the
Celerity host adapter as a unique part of your
configuration. The address is clearly marked on
the back of the board for easy identification.
Please keep a reference copy of the number in a
safe place or write in the space provided on this
page.
Celerity FC host adapter WWNs are assigned for
each channel. The WWN listed on your host
adapter is assigned to the first channel (0).
Sequential WWNs apply for additional channels.
WWN 0 all adapters
WWN 1: 44ES, 42ES, 42XS
WWN 2 44ES
WWN 3 44ES
Installation
CAUTIONCAUTION
Celerity FC host adapters contain
components that are sensitive to
electrostatic discharge (ESD). ESD can
cause damage to the Celerity FC host
adapter. Please follow standard methods to
avoid ESD.
1Install the latest drivers. Refer to Installing and
updating drivers on page 11.
2Power down the computer and unplug the
computer from all power sources.
3Open the case.
4
Install the Celerity FC host adapter in any open
PCI, PCI-X or PCI Express expansion slot. If
you have questions about how to install an
expansion card in your system, consult your
computer’s documentation.
Drawings of Celerity brackets begin on page 16
and drawings of boards begin on page 18.
Note
The Celerity FC-41XS, and FC-42XS host
adapters only fit in 3.3V slots.
The Celerity FC-42ES, FC-41ES and FC-41EL
fit into x4, x8, or x16 mechanical PCI Express
slots.
If you have trouble seating your adapter in a 32bit PCI bus computer, check to make sure the
connector can accommodate 64-bit host
adapters.
5Connect Fibre Channel devices by inserting a
Fibre Channel cable from the devices to the
connectors on the Celerity FC host adapter until
you hear a click.
6Close the case on the computer and power it
up.
15 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 19
Bracket details
Exhibit 4-1 FC-44ES Adapter
Exhibit 4-3 FC-41ES low profile, full height adapters
Exhibit 4-2 FC-42ES low profile, full height adapters
Exhibit 4-4 FC-41EL low profile, full height adapters
16
Page 20
Exhibit 4-5 FC-42XS low profile, full height adapters
Exhibit 4-7 FC-21PS Adapter
Exhibit 4-6 FC-41XS low profile, full height adapters
17 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 21
Adapter board details
Exhibit 4-8 FC-44ES
Exhibit 4-9 FC-42ES
SFP LC optical
connectors
FC controller
PCIe connector
18
Page 22
Exhibit 4-10 FC-41ES
SFP LC optical
connector
Exhibit 4-11 FC-41EL
FC controller
PCIe connector
SFP LC
optical
connector
PCIe connector
19 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 23
Exhibit 4-12 FC-42XS
Exhibit 4-13 FC-41XS
20
Page 24
Exhibit 4-14 FC-21PS
21 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 25
5 Updating hardware flash
Your Celerity FC host adapter was flashed before shipment, but the flash memory may need to be
updated as new versions become available or if the factory-installed version becomes corrupt. Visit the
ATTO website,
www.attotech.com
, to download the latest drivers and flash bundle.
Hardware flash memory may need to be updated
as new versions become available or if the
factory-installed version becomes corrupt.
Updating flash in all operating systems
1Download the most recent version of the
Configuration Tool from the ATTO website.
Refer to the ATTO Utilities Installation and
Operation Manual for additional information on
downloading and using the Configuration Tool.
2Download the proper flash bundle (adapter
specific) from the ATTO website.
3Extract these files to your desktop.
4Install the Configuration Tool on your system.
5Launch the Configuration Tool.
6In the Device window, select the adapter that
needs to be updated.
7In the Flash window, click on the Browse
button to find the flash bundle that you
previously downloaded to your desktop.
8Click Update to update your flash ROM.
9Reboot your system for the changes to take
effect.
Updating flash on a PC
You may update hardware flash on a PC using
BIOS utilities.
Note
BIOS utilities do not work on Itanium
systems. Use the ATTO Configuration Tool
to update flash on Itanium systems.
1Download the latest driver software from the
ATTO Technology website.
2The download is a self-extracting executable
that expands the driver software package. Run
the self-extracting executable and select a
folder in which to place the expanded software
package.
The expanded software package contains a
Miniport driver and may contain a StorPort
driver. The Celerity FC Windows Miniport driver
is in the base directory of the expanded
software package. The Celerity FC Windows
StorPort driver is in the StorPort subdirectory.
3Navigate to the folder with the desired Celerity
FC driver.
4Run makedisk.bat and follow the instructions
for creating the floppy disk.
Note
The flash update must be loaded from a
floppy because CD-ROM drivers are not
loaded at this point in the system boot
process.
5Reboot the PC.
6During the reboot, an ATTO Technology
banner displays that the host adapter was
detected.
7Enter Control-F when prompted to begin the
set-up utility within a few seconds after the
banner appears.
If you do not enter Control-F soon enough after
the banner appears, repeat steps 5 and 6.
8In the utility, select the Upgrade Flash ROM
option.
9Insert the disk into the drive slot.
10 Follow the on-screen instructions.
11 Remove the disk and reboot your system for
the flash ROM changes to take effect
22
Page 26
6 Troubleshooting
This chapter contains solutions for the most common problems you might encounter. If you need
additional assistance, please refer to the ATTO Technology website,
authorized ATTO Technology representative.
www.attotech.com
, or contact an
General suggestions
• Check each cable connection on every device.
• Verify all cables are in proper working condition.
Loose or broken cables are often the cause of
errors or problems.
Mac OS X
Note
The Celerity FC supports Mac OS X versions
10.3 and later.
1Open the ATTO Configuration Tool from the
ATTO Utilities CD or download from the ATTO
website. Refer to the ATTO Utilities Installation
and Operation Manual for additional
information.
2If the adapter does not appear in the Device
Listing, make sure it is properly seated in the
PCI slot.
a. Remove power from the PC.
b. Remove the case.
c. Check the PCI slot.
d. Replace the case.
e. Apply power.
Note
If the Celerity adapter is properly seated and
devices are still not accessible, contact an
authorized ATTO representative.
• Check that Fibre Channel devices are plugged
into an AC outlet and are turned on before you
add power to your computer.
3Verify the driver is loaded.
a. Click on the adapter name in the
Device Listing to view the Basic Info
screen.
b. If the Driver Information section
indicates Unknown: driver not loaded, reinstall the driver. Refer to
Installing and updating drivers
11.
c. If reinstalling the driver does not fix the
problem, contact an authorized ATTO
representative.
4Reset the NVRAM for all channels to defaults
and reboot. If the problem persists, contact an
authorized ATTO representative.
Note
When calling ATTO Technical Support,
please have a printout of the IOreg listing
and output from the Apple System Profiler
available.
on page
Windows 2000/XP/Server 2003/Vista
• If the card has been recently re-flashed, the new
Windows driver must be installed. Follow the
procedure in Installing and updating drivers
page 11.
• All of the external devices connected to the host
adapter should be identified. If they do not
appear in the Device Manager, the external
devices or connection may not be working
properly.
• For Intel-based PCs, check the computer CMOS
setup and verify that the PCI slots are configured
correctly.
23 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
on
• Procedures vary greatly: refer to the manual
supplied with your system or call the computer
supplier for configuration assistance.
• Windows 2000/XP/Server 2003/Vista are Plugn-Play operating systems: be sure your
computer’s BIOS is set accordingly.
• If these do not solve the problem, re-flash the
host adapter and re-install the Windows
2000/XP/Server 2003/Vista driver. See
Installing and updating drivers
on page 11.
Page 27
If the devices connected to the Celerity FC host
adapter are not accessible
1Right-click My Computer.
2Select Properties.
3Select the Hardware tab.
4Select Device Manager.
• If the Celerity FC host adapter does not appear
under the SCSI and RAID controllers, remove
power from the PC, open the case, and check
that the Celerity FC adapter is properly seated in
the PCI slot. Replace the case and apply power.
Linux
• If the adapter has been identified but there is an
exclamation point (!) on the listing, right click on
the listing and select Uninstall.
5Reload the driver (see Installing and updating
drivers on page 11).
6Reboot the system and repeat the installation
process.
7If problems persist, contact your authorized
ATTO Technology representative.
1Verify the celerityfc driver is loaded with the
lsmod
command. If lsmod does not show the
driver, refer to the installation instructions to
install and load the driver in Installing and
updating drivers on page 11.
2Check the system log with the command
dmesg
messages during initialization. Make sure that
all installed cards are properly detected and
initialized.
. The celerityfc driver creates status
3Examine the contents of the file(s)
/proc/scsi/celerityfc/X, where X is the
adapter’s host number. This file contains details
such as link status, connection speed and
discovered devices.
Note
Advanced users only. Modify the
makefile
Upon loading, the
detailed debugging information which may
help troubleshoot the problem.
to enable debugging information.
celerityfc driver
driver
displays
24
Page 28
Appendix A Standards and compliances
The equipment described in this manual generates and uses radio frequency energy. The Technical
Specification sheet for a particular Celerity FC host adapter lists certifications for that model.
FCC standards: radio and television interference
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Canadian standards
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European standards
Declaration of Conformity
This following statement applies to the Celerity FC host adapter.
This device has been tested in the basic operating configuration and found to be
compliant with the following European Union standards: Application of Council
Directive: 89/336/EEC
Standard(s) to which conformity is declared: EN55024:2002; EN55022:2002 CLASS B
This Declaration will only be valid when this product is used in conjunction with other CE approved
devices and when the entire system is tested to the applicable CE standards and found to be compliant.
Some ATTO Celerity cards comply with Directive 2002/95/EC on the Restriction
of the Use of Hazardous Substances in Electrical and Electronic Equipment
(RoHS). Contact your ATTO representative regarding RoHS compliant products.
i ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 29
The following apply to the Celerity FC-42XS host adapter only:
ii
Page 30
Appendix B Accessories
The following Fibre Channel accessories are available through ATTO Technology and authorized
resellers. Contact an ATTO Technology authorized sales representative to order.
Optical Cables
CBL-FCFI-05x5 m. cable– Duplex 50 Micron Multi-mode FC/Optical
CBL-LCSC-0033 m. 50/125 optical cable (LC to SC)
CBL-LCSC-01010 m. 50/125 optical cable (LC to SC)
A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology.
Please contact your ATTO sales representative for product descriptions and part number information.
Fibre Channel and iSCSI solutions
ATTO FibreBridgeTMFibre Channel-to-SCSI bridge
ATTO iPBridgeiSCSI to SCSI, iSCSI to Fibre Channel bridges
SCSI solutions
ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix C)
SAS/SATA Solutions
ATTO ExpressSAS family of SAS Adapters (see Appendix D)
Software
ATTO UtilitiesConfiguration and management software
ATTO ExpressStripe Mac OS X RAID and benchmark software
ATTO Express Power CenterWindows-based striping utility
iii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 31
Appendix C SCSI adapter selection guide
Ultra 320 SCSI
Product Features
Max. transfer rate (MB/sec.)640640640320
Low Voltage Differential
Single-ended SCSI
Number of SCSI Channels
Number of SCSI IDs supported
Low profile
Large file transfers
Cable distances (m)
32-bit PCI compatible
64-bit PCI compatible
33 MHZ PCI
133 MHZ PCI-X
66 MHz PCI
x4 PCI Express
Windows 2000/XP, Server 2003/Vista support
Linux support
Mac OS X support
Novell Netware support
RoHS compliant
UL5DUL5D LPUL4DUL4S
• • • •
• • • •
2/20/22/21/1
30303030
•
• • • •
12.512.512.512.5
• •
• •
• •
• •
• •
• •
• • • •
• • • •
• • • •
• • • •
• • • •
iv
Page 32
Appendix D SAS adapter selection guide
Product Features
Max.transfer rate
x8 PCI Express
Number of ports
Port configuration external/internal
Connector type
Number of devices supported
1.5 Gb SATA support
3 Gb SATA II support
3 Gb SAS support
Cable distances
Integrated RAID
RAID Management Utility
Global Hot Spares
Event notification
Memory (ECC)
Advanced Data Streaming™
Battery backup
32-bit support
64-bit support
Windows 2000/CP, Server
2003/Vista support
Linux (Red Hat, SUSE) support
Mac OS X support
RoHS compliant
Low profile
1
Performance ceiling constrained by PCIe bus transfer speed
2
Future support
1
(full duplex)
user selectable 4/4 or 0/8
1 mini SAS (x4) SFF-8088 external
2 mini SAS (x4) SFF-8087 internal
64 SAS/SATA targets
128 virtual devices
0, 1, 4, 5, 62, 10, 50, 602, JBOD,
E-mail, pop-up, log fileE-mail, pop-up, log file
258 MB standard
512 upgradeable (OEM)
ATTO ExpressSAS RAID Adapters
R348R380
4 GB/sec.4 GB/sec.
• •
88
4/8
• •
• •
• •
up to 8mup to 8m
DVRAID
• •
• •
• •
optionaloptional
• •
• •
• •
• •
• •
• •
• •
8/0
2 mini SAS (x4) SFF-8088 external
64 SAS/SATA targets
128 virtual devices
0, 1, 4, 5, 62, 10, 50, 602, JBOD,
DVRAID
258 MB standard
512 upgradeable (OEM)
v ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 33
Appendix E Safety, warranty, contacts
All ATTO host adapter products have been tested to meet applicable safety standards when operated in
proper electrical and thermal environments.
Safety
Please review the specifications for your specific host adapter before installing and operating it in any
computer system to ensure compatibility.
Installation
Before installing an ATTO host adapter product into your computer system, unplug the computer from
its electrical power source and allow adequate time for electrical discharge and the internal components
to cool down before removing the computer system cover. This will decrease the risk of personal injury
from electrical shock or touching the hot surface of an electrical component.
Once an ATTO host adapter is installed in a computer system, the computer cover must be reinstalled
properly before turning the computer system back on.
Operation
ATTO host adapters require adequate cooling to function properly. If you have any questions as to the
airflow provided by your computer system, please refer to your computer system manual or contact your
computer system manufacturer.
To facilitate proper air circulation, ATTO host adapters should never be operated in a computer system
without the cover installed or with an inoperable fan as this may cause safety or thermal problems which
could damage the ATTO host adapter and void the warranty.
ATTO Technology, Inc. limited warranty
ATTO Technology, Inc. warrants to the original purchaser of this product that it is free from defects in
material and workmanship as described in the ATTO Technology website,
ATTO Technology, Inc. liability shall be limited to replacing or repairing, at its option, any defective
product. There is no charge for parts or labor should ATTO Technology, Inc. determine that this product
is defective.
Products which have been subject to abuse, misuse, alteration, neglected, or have been serviced, repaired
or installed by unauthorized personnel shall not be covered under this warranty provision. Damage
resulting from incorrect connection or an inappropriate application of this product shall not be the
responsibility of ATTO Technology, Inc. Liability is limited to ATTO Technology, Inc.product(s);
damage to other equipment connected to ATTO Technology, Inc.product(s) is the customer’s
responsibility.
This warranty is made in lieu of any other warranty, express or implied. ATTO Technology, Inc.
disclaims any implied warranties of merchantability or fitness for a particular purpose.
www.attotech.com
.
vi
Page 34
ATTO Technology, Inc. responsibility to repair or replace a defective product is the sole and exclusive
remedy provided to the customer for breech of this warranty. ATTO Technology, Inc. is not liable for
any indirect, special, incidental, or consequential damages irrespective of whether ATTO Technology,
Inc. has advance notice of the possibility of such damages.
No ATTO Technology, Inc. dealer, agent or employee is authorized to make any modification,
extension or addition to this warranty.
vii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.