ATTO Technology FC-44ES User Manual

Page 1
ATTO Celerity Fibre Channel Host Adapters
Installation and Operation Manual
Celerity FC-44ES
4-Gb FC quad channel PCIe host adapter
Celerity FC-42ES
4-Gb FC dual channel PCIe host adapter
Celerity FC-41ES
4-Gb FC single channel PCIe host adapter
Celerity FC-41EL
4-Gb FC single channel host adapter
Celerity FC-42XS
Celerity FC-41XS
4-Gb FC single channel PCI-X host adapter
Celerity FC-21PS
2-Gb FC single channel PCI-X host adapter
Page 2
ATTO Technology, Inc.
155 CrossPoint Parkway Amherst, New York 14068 USA
www.attotech.com
Tel (716) 691-1999 Fax (716) 691-9353
Sales support: sls@attotech.com Technical support: Monday -- Friday, 8am-8pm EST
techsupp@attotech.com
© 2007 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
9/2007
........................................................................................................
Document Control Number: PRMA-0344--000
Page 3
Contents
1 ATTO provides Fibre Channel solutions ..........................................1
Celerity FC-44ES Adapter Celerity FC-42ES Adapter Celerity FC-41ES Adapter Celerity FC-41EL Adapter Celerity FC-42XS Adapter Celerity FC-41XS Adapter Celerity FC-21PS Adapter Celerity selection guide
2 Fibre Channel is a key technology for storage ................................9
Glossary
3 Installing and updating drivers .........................................................11
Specialized configurations Windows 2000/XP/Server 2003/Vista Mac OS X driver installation, update Linux driver installation, update
4 Hardware installation ..........................................................................15
Bracket details Adapter board details
5 Updating hardware flash ....................................................................22
6 Troubleshooting ..................................................................................23
Mac OS X Windows 2000/XP/Server 2003/Vista Linux
Appendix A Standards and compliances ............................................i
FCC standards: radio and television interference Canadian standards European standards
Appendix B Accessories .......................................................................iii
Appendix C SCSI adapter selection guide ..........................................iv
Appendix D SAS adapter selection guide ...........................................v
Appendix E Safety, warranty, contacts ................................................vi
Safety ATTO Technology, Inc. limited warranty
Page 4

1 ATTO provides Fibre Channel solutions

The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching, backup and data management. Specifically designed to enhance the functionality of third party fabric hardware and software, Celerity FC products are the industry-leading platform for storage connectivity.

Celerity FC-44ES Adapter

The Celerity FC-44ES uses PCI Express Interconnect and 4-Gigabit Fibre Channel to provide 4-Gb FC speeds of up to 800 MB/sec. per channel. The FC­44ES supports high-definition video, rich content databases and other high bandwidth environments.
The FC-44ES uses PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec. (x8 PCIe) full-duplex. With software compatible with existing PCI and PCI-X products, the FC-44ES uses the same device drivers as other Celerity FC family products, simplifying installation and support.

Hardware specifications

• 4 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Supports exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI

Host bus specifications

• x8 mechanical and x8 electrical PCI Express Interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI Express to PCI/PCI-X Bridge spec 1.0

Environmental & physical specifications

• Conforms to PCI standard height, half length form-factor specifications
• Length: 6.525 inches
• Height: 3.81 inches
• Operating temperature: 0-45ºC (32-113ºF)
• Storage temperature: -40 to 70ºC (-40 to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 12V@ 2.1A (max.)
• 3.3V @ 3.0A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant

External connectivity

• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for each channel
• 4 pluggable optical LC SFP transceivers included

Software specifications

• Windows XP, 2000, Server 2003 and Vista
• Mac OS X (10.4.x, 10.5.x)
• Red Hat Linux
• SUSE Linux (2.6 kernel)
(2.4 and 2.6 kernel)
1 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 5

Celerity FC-42ES Adapter

The Celerity FC-42ES is a dual-channel host adapter providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-42ES supports the most demanding application requirements.
Additionally the FC-42ES takes advantage of the latest in host interconnect technology, PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec. (x8 PCIe) full-duplex. The FC-42ES is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC family products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb Fibre Channel infrastructure, protecting existing technology.

Hardware specifications

• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-AL, FC-AL2, FC-FCP, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Supports exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI

Host bus specifications

• x4 mechanical and x4 electrical PCI Express interconnect (RoHS compliant)
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI Express to PCI/PCI-X Bridge spec 1.0

Environmental & physical specifications

• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 100 lf/m (minimum) airflow recommended
• Conforms to PCI half height, half length form­factor specifications
• 12V@ 04A (max.); 3.3V @ 1.5A (max.)
• Length: 5.6 inches
• Height: 2.712 inches
• RoHS compliant

External connectivity

• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for each channel
• 2 pluggable optical LC SFP transceivers included

Software specifications

• Windows XP, 2000, Server 2003 and Vista
• Mac OS X (10.4.x, 10.5.x)
• Red Hat Linux
• SUSE Linux (2.6 kernel)
(2.4 and 2.6 kernel)
2
Page 6

Celerity FC-41ES Adapter

The Celerity FC-41ES is a single-channel host adapter providing support for the most demanding application requirements. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-41ES is a cost effective connectivity solution for environments requiring maximum throughput.
The FC-41ES also takes advantage of the latest in host interconnect technology: PCI Express, a serial, high­speed connection that supports aggregate throughput up to 2 GB/sec. (x4 PCIe) full-duplex. The FC-41ES is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb Fibre Channel infrastructure, protecting existing technology investments.

Hardware specifications

• 1 Fibre Channel port
• 4-Gigabit FC data transfer rates
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Features exclusive Advanced Data Streaming (ADS) Technology
FDMI and WMI

Host bus specifications

• x4 mechanical and x4 electrical PCI Express interconnect
• Supports PCI Express Base Spec 1.0a and CEM Spec 1.0a
• Supports PCI Express to PCI/PCI-X bridge spec
1.0

Environmental & physical specifications

• Conforms to PCIe low profile form factor specifications
• Length: 5.600 inches
• Height: 2.712 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 100 lf/m (minimum) airflow recommended
• Power: 12V@ 0.4A max; 3.3V@1.0A max.
• RoHS compliant

External connectivity

• Easy-to-install full height connection bracket
• External LEDs for on-line and speed status
• Pluggable optical LC SFP transceiver included

Software specifications

• Windows XP, 2000, Server 2003 and Vista
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4.x, 10.5.x)
3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 7

Celerity FC-41EL Adapter

The Celerity FC-41EL is a single-channel host adapter. With 4-Gb FC speeds of up to 800 MB/sec., the FC-41EL supports the most demanding application requirements.
The FC-41EL takes advantage of the latest in host interconnect technology, PCI Express, a serial, high­speed connection that supports aggregate throughout up to 2 GB/sec.full-duplex. The FC-41EL is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC family products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb FC infrastructures, protecting existing technology investments.

Hardware specifications

• 1 Fibre Channel port
• 4-Gigabit data transfer rate
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 4

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation between 4­Gb, 2-Gb and 1-Gb Fibre Channel
• Supports initiator and target modes
• Supports Windows® FDMI and WMI
• Supports exclusive ATTO Advanced Data Streaming (ADS™) technology

Host bus specifications

• x4 mechanical and x4 electrical PCIExpress interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a

Environmental & physical specifications

• Conforms to PCIe low profile form factor specifications
• Operating temperature: 0 to 45º C (32-113º F)
• Storage temperature: -40 to 70ºC (-40 to 158º F)
• Relative humidity: 10 to 90% non-condensing
• 100 lf/m (minimum) airflow recommended
• Conforms to PCI Express low-profile form-factor specification
• 12V @ 0.5A (max)
• Length: 5.600 inches
• Height: 2.712 inches
• RoHS compliant

External connectivity

• Easy-to-install full and low-profile connection plates
• External LEDs for on-line and speed status
• A pluggable optical LC SFP transceiver included

Software specifications

• Windows XP, 2000, Server 2003 and Vista
• Mac OS X (10.4.x, 10.5.x)
4
Page 8

Celerity FC-42XS Adapter

The dual-channel Celerity FC-42XS host adapter provides the highest available throughput for Fibre Channel applications while protecting technology investments via backward compatibility with existing infrastructure.
With speeds of up to 800 MB/sec. per channel, the FC­42XS is capable of supporting the most intensive data applications.
To ensure a smooth transition path, the FC-42XS leverages the existing Celerity FC software hardware architecture, allowing ATTO to deliver industry­leading quality and stable software architecture.

Hardware specifications

• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Includes exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI

PCI bus specifications

• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only

Environmental & physical specifications

• Conforms to PCI low profile form factor standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 3.3V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant

External connectivity

• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for each channel
• 2 optical LC SFP transceivers included

Software specifications

• Windows XP, 2000, Server 2003 and Vista
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4x, 10.5x)
5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 9

Celerity FC-41XS Adapter

The single-channel Celerity FC-41XS provides speeds of up to 800 MB/sec. using full 4-Gigabit Fibre Channel performance while being fully backward­compatible with existing 2-GB and 1-Gb Fibre Channel infrastructure, protecting existing technology investments. It is capable of supporting the most data­intense applications.

Hardware specifications

• 1 Fibre Channel port
• 4-Gigabit data transfer rates
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Includes exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI

PCI bus specifications

• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only

Environmental & physical specifications

• Conforms to PCI low profile form factor standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 3.3V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant

External connectivity

• Easy-to-install full height connection plate
• External LEDs for on-line and speed status
• Optical LC SFP transceiver included

Software specifications

• Windows XP, 2000, Server 2003 and Vista
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4.x, 10.5.x)
6
Page 10

Celerity FC-21PS Adapter

The Celerity FC-21PS Fibre Channel host adapter provides a single 2-Gb Fibre Channel connection from host devices to the Storage Area Network (SAN) fabric.
The FC-21PS supports the leading operating systems, providing a single solution for all connectivity needs. As with all Celerity FC products, the FC-21PS is designed for high-quality data transmission, ensuring that critical information is delivered correctly the first time to reduce fabric traffic and improve overall fabric efficiency.

Hardware specifications

• 1 Fibre Channel port
• 400 MB/sec. throughput full-duplex
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• Flash ROM for easy field upgrades
• Simultaneous multi-protocol support
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA, IETF-IPFC

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand, automatic negotiation between 2­Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Includes exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI

PCI bus specifications

• 64-bit/32-bit, 66/33 MHz PCI compatible
• PCI 2.3 compliant
• 3.3V and 5V PCI signaling with universal connector

Environmental & physical specifications

• Conforms to PCI low profile form factor standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 5V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended

External connectivity

• Easy-to-install full height connection plate
• Integrated optical LC SFF fixed transceiver
• External LEDs for on-line and speed status

Software specifications

• Windows XP, 2000, Server 2003 and Vista
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4.x, 10.5.x)
7 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 11

Celerity selection guide

Celerity FC-41ES FC-41EL
800 MB/sec 1 GB/sec
4
300m@2-Gb 150m@4-Gb
Celerity
FC-42XS
64-bit
133 MHz
300m@2-Gb 150m@4-Gb
Celerity
FC-41XS
1
800 MB/sec 400 MB/sec
2
64-bit
133 MHz
300m@2-Gb 150m@4-Gb
Product Features
Fibre Channel Ports FC protocol Maximum Transfer Rate (half
duplex) Maximum Transfer Rate (full-
duplex) Bus Type
Bus Characteristics
Optical Interface
Maximum Cable Length
Low Profile form factor ATTO Advanced Data
Celerity
FC-44ES
42 1 211
4-Gb 4-Gb 4-Gb 4-Gb 4-Gb 2-Gb
1.6 GB/sec 800 MB/sec 400 MB/sec 800 MB/sec 400 MB/sec 200 MB/sec
2 GB/sec
PCIe PCIe PCIe PCI-X PCI-X PCI-X
8 lane 4 lane 4 lane
SFP LC SFP LC SFP LC SFP LC SFP LC SFF LC
300m@2-Gb 150m@4-Gb
• • • • • •
Celerity
FC-42ES
1 GB/sec (ES)
1.6 GB/sec (EN)
300m@2-Gb 150m@4-Gb
• • • • •
Streaming (ADS) Technology Software RAID support
3
Developer's Kit (Target Mode & API)
Windows XP, 2000, Server
• • • • • •
• •
• • • • • •
ES only
• • •
2003 and Vista support Linux (Red Hat, SUSE) driver Macintosh OS X driver Novell Netware support Solaris support Free BSD RoHS compliant
1 Performance ceiling is constrained by 133 MHz PCI-X bus transfer speed 2 Backward compatible to 32-bit and 33 MHz PCI; FC-21PS is 3.3V/5V Universal 3 ATTO ExpressStripe for OS X available; Express Power Center and other software RAID supported for Windows 4 FC-41EL 32-bit support only
• •
• • • • • •
• •
• •
• •
• • • • •
ES only
ES only
ES only
ES only
• • •
• •
• •
• •
2
Celerity
FC-21PS
64-bit
133 MHz
500m@1-Gb 300m@2-Gb
2
8
Page 12

2 Fibre Channel is a key technology for storage

Fibre Channel is a serial communications technology designed to transfer large amounts of data among a variety of hardware systems over long distances. It is a key technology for applications that require shared, high bandwidth access to storage.
Fibre Channel provides a logical, point-to-point, serial channel for the transfer of data between a buffer at a source device and a buffer at a destination device. It moves buffer contents from one port to another, without regard to the format or meaning of the data so different upper level
protocols are able to run over Fibre Channel hardware.
The Fibre Channel architecture is structured as a hierarchical set of protocol layers. Defined within these layers are rules for signal interfaces, serial encoding and decoding, error control, frame format and communications protocols.

Glossary

Some terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology website
(
www.fibrechannel.com
(
www.snia.org
)
, and the Fibre Channel Consortium (
Term Definition
ANSI American National Standards Institute
arbitrate process of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop
arbitrated loop a loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can
auto negotiation hardware senses and automatically responds depending on configuration
BER Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent
bit smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1
bus a collection of unbroken signal lines used to transmit information from one part of a computer
byte an ordered set of 8 bits
channel a point-to-point link which transports data from one point to another
CPU Central Processing Unit: the portion of the computer that actually performs computations
CRC Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
destination address
device driver a program that allows a microprocessor to direct the operation of a peripheral device
DMA Direct Memory Access: a way to move data from a storage device directly to RAM without using
DMA bus master allows a peripheral to control the flow of data to and from system memory by block as opposed to
)
, Cern (
(
www.attotech.com
www.cern.ch
at the same time
communicate at one time; low-cost solution which may or may not use hubs and switches
system to another; taps on the lines connect devices to the bus
and transmitted data; if no error has occurred during transmission, the CRC for both received and transmitted data should be the same
a value in the frame header of each frame which identifies the port in the node where the frame is being sent
the CPU’s resources
allowing the processor to control the data by bytes (PIO or programmed I/O)
)
, the Fibre Channel Industry Association
)
, the Storage Area Networking Industry Association
www.iol.unh.edu/consortiums
, click on FC)
.
9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 13
Term Definition
fabric a Fibre Channel switch of two or more Fibre Channel switches interconnected to physically
transmit data between any two N_Ports on the switch or switches
FC Fibre Channel
F_port a port in the Fibre Channel fabric where a N_port may attach
FL_port a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop
frame an indivisible unit for transfer of information in Fibre Channel
frame header the first field in the frame containing the address and other control information about the frame
full-duplex a communication protocol which allows transmission in both directions at the same time
half duplex a communication protocol which allows transmission in both directions, but only one direction at a
time
host a processor, usually a CPU and memory, which communicates with devices over an interface
initiator device a component which originates a command
L_port a port in an arbitrated loop, either a NL_port or a FL_port
LED Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
are used as indicator lights on all sorts of electronic devices
LUN Logical Unit Number: an identifier for a logical unit (0-7)
multi-mode fiber an optical fiber which can carry several beams of light at once
N_port a port attached to a node used with point to point or fabric configurations
NL_ port a port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration
originator an initiating device; a component which originates a command
parity checking a method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error message occurs if the sum is not correct
PCI Peripheral Component Interconnect. Allows peripherals to be connected directly to computer
memory, bypassing the slower ISA and EISA busses
point-to-point a topology where two ports communicate
port an access point in a device: see N_port, NL_port, etc.
port address also port number; the address, assigned by the PCI bus, through which commands are sent to a
host adapter board
port number see port address
receiver the ultimate destination of data transmission; a terminal device
scatter/gather a device driver feature which allows the host adapter to modify a transfer data pointer so that a
single host adapter can access many segments of memory, minimizing interrupts and transfer overhead
SCSI Small Computer Systems Interface: a processor-independent standard for system-level interface
between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers, scanners, etc.
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source
topology logical layout of the parts of a computer system or network and their interconnections
transceiver a transmitter/receiver module
transfer rate the rate at which bytes or bits are transferred, as in megabytes or gigabits per second
10
Page 14

3 Installing and updating drivers

Before installing your Celerity adapter, you must configure your system to recognize and use it by installing drivers for your operating system.
Configure your system to recognize and use your Celerity adapter by
• installing drivers for your operating system
• updating the adapter firmware if necessary (refer to Updating hardware flash
Note
If you already have one or more Celerity adapters installed and you are installing additional adapter(s), you do not need to perform any of these procedures unless you are updating a previously installed driver.
on page 22)

Specialized configurations

Some specialized applications may benefit from modification of adapter settings. The ATTO Utilities Installation and Operation Manual provides detailed information on using ATTO Technology configuration utilities found on the ATTO Utilities CD or downloaded from the ATTO website. For best performance, use the most recent device driver and flash version.
Verify the version based on your operating system.
Windows:
from the ATTO Utilities CD, or download it from
www.attotech.com
string during system boot or look in the
Manager
Use the ATTO Configuration Tool
, or view the adapter boot
Device
.
ATTO Celerity adapters ship with the latest firmware installed.
The Celerity FC Installation CD shipped with your adapter contains the latest driver.
The Installation CD automatically starts when inserted in the system CD-ROM drive. Navigate the easy-to-use HTML-based menu to find the driver that you want to install.
If the CD does not automatically start, open the CD and click on
Note
Windows NT is only supported with Celerity driver version 1.31 or earlier. If you are using Windows NT, contact your service representative.
Mac OS X
autorun.bat
.
: Use the ATTO Configuration Tool on
the ATTO Utilities CD, or download it from
www.attotech.com,
or use the Apple System
Profiler.
Linux
: Use the ATTO Configuration Tool on the
ATTO Utilities CD, or download it from
www.attotech.com
examine
/proc/scsi/celerityfc/X
, or to find the driver version,
, where X is the
adapter’s host number.

Windows 2000/XP/Server 2003/Vista

Five procedures are described below. Review each thoroughly to ensure that you are using the one that best fits your needs. If you have one or more Celerity FC adapters installed in your system and you are installing additional adapter(s), you do not need to perform any of
11 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
these procedures unless you are updating a previously installed driver.
The Celerity FC Installation Disk can be the Installation CD shipped with your adapter, a folder containing the latest downloaded and expanded driver, or a Celerity FC installation floppy disk.
Page 15

Upgrading an existing Celerity FC driver

1 Log on to Windows as the System
Administrator.
2 Insert your Celerity FC Installation Disk and run
autorun.bat
3In Windows Drivers, select your operating
system version.
4 Click on Install Driver.

Adding a Celerity FC adapter to an existing installation

Note
Complete this installation procedure before attaching any devices to the adapter.
1 Complete the steps in Updating hardware flash
on page 22 to pre-install the driver.
2 Close Windows and turn off power to your PC
when Setup prompts you to do so.
3 Install your new Celerity FC adapter into an
available PCI expansion slot. a. If the Celerity FC adapter is replacing
another adapter in the system, disconnect the FC cables from the adapter and remove the adapter from the system, or move the Celerity FC adapter to the PCI slot that the previous adapter occupied.
b. Attach the appropriate FC cables to the
Celerity FC adapter.
4 Close the computer chassis
5 Turn on the power and restart Windows.
6 During the boot process, Windows detects your
Celerity FC adapter and the Found New Hardware Wizard is displayed.
Follow the directions in the Found New Hardware Wizard, selecting the default settings for each adapter channel.
7 Insert the Celerity FC Installation disk when
asked to do so.
8 When adapter installation is complete, the
Found New Hardware Wizard displays an ATTO Phantom Device for each channel. Use
the wizard default settings to complete the installation.

Creating a boot disk

Note
The procedure described below does not apply to Windows Server 2003 for Itanium systems because the Celerity FC driver does not support boot functionality on Itanium systems.
1 Start Windows text mode setup as found in the
instructions provided with Windows.
2 Press F6 when Windows Setup, displays. The
setup program displays a prompt in the status window on the bottom left of the monitor. Setup continues to load files after you press F6.
3 A new window displays instructions to specify
additional mass storage devices. Press S to install the ATTO Celerity as a storage device.
4 Insert the Celerity FC installation diskette in
drive A and press Enter.
5 A screen displays a list of Celerity FC adapters.
Select your adapter and press Enter.
6 Windows Setup loads the files from the floppy
and then displays the screen described in Step
2. The ATTO Celerity FC device should now be
listed as detected.
7 Repeat steps 2
supplied driver installation disks.
8 After all other drivers have been processed,
press Enter and proceed with the rest of the Windows installation procedure.
Note
When Windows begins copying files to your hard disk, a display prompts you to insert the Celerity FC installation disk and any other vendor-supplied disks you used during custom installation. This is normal. The first time you inserted the disks, Windows loads the drivers into memory; the second time you insert the disk(s), Windows copies the driver to your hard disk.
to 6 for any other vendor-
12
Page 16

Creating a Celerity FC installation floppy

Note
You must have a floppy disk with the Celerity FC driver software to install a fresh copy of the Windows OS onto a disk attached to a Celerity FC adapter.
1 Insert the Installation CD into a CD-ROM. The
installation starts automatically.
If the Celerity FC installation does not start, navigate to the root of the CD and run autorun.bat
2Select Windows Drivers from the items on the
left side of the screen.
3 Select the appropriate CPU-based operating
system from operating system choices.
4Select Create Miniport Driver Diskette or
Create StorPort Driver Diskette for the desired operating system.
5 Follow the instructions for creating the floppy
disk.

Creating a floppy disk from a download

1 Download the latest driver software from the
2 The download is a self-extracting executable
3 Navigate to the folder with the desired Celerity
4Run makedisk.bat and follow the instructions

Mac OS X driver installation, update

ATTO website,
that expands the driver software package. Run the self-extracting executable and select a folder to place the expanded software package.
FC driver.
Note
The expanded software package contains a Miniport driver and may contain a StorPort driver. The Celerity FC Windows Miniport driver is in the base directory of the expanded software package. The Celerity FC Windows StorPort driver is in the StorPort subdirectory.
for creating the floppy disk.
www.attotech.com.
1 Extract the latest version of the device driver file
to your desktop.
2 Double click the installer icon and follow the on
screen prompts.

Linux driver installation, update

Note
You must have kernel header files for the appropriate kernel installed.
You must be logged in as
1 At the command prompt type rmmod
celerityfc
root
.
3 Reboot your system for the changes to take
effect.
2 Download the appropriate version of the device
driver from the ATTO website.
3 At the command prompt, extract the file using
the command tar -xfz <filename.tgz>
4 Enter the directory created in the above step
and type make install to overwrite any previously-installed driver.
5 Start the driver by typing modprobe celerityfc
13 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 17
14
Page 18

4 Hardware installation

You need a basic understanding of Fibre Channel before installing the Celerity FC host adapter. Please refer to
Fibre Channel is a key technology for storage
on page 9 for a list of related websites.
CAUTIONCAUTION
Back up your system data before changing or installing any hardware.

System requirements

The Celerity FC host adapter package contains the host adapter, the ATTO Utilities CD and a warranty and registration card. If any of these items are missing, contact your ATTO authorized sales representative.
To install and use the Celerity Fibre Channel host adapter you need
• A computer with an available PCI, PCI-X or PCI Express expansion slot
• The complete Celerity FC host adapter package

Fibre Channel address

Celerity FC adapters are configured with a unique address designated by the Institute of Electrical and Electronic Engineers. The WorldWide Port Name (WWN) and Node Name are the two components of the address assigned to Fibre Channel products. This address, stored in flash memory, allows the system to recognize the Celerity host adapter as a unique part of your configuration. The address is clearly marked on the back of the board for easy identification. Please keep a reference copy of the number in a safe place or write in the space provided on this page.
Celerity FC host adapter WWNs are assigned for each channel. The WWN listed on your host adapter is assigned to the first channel (0). Sequential WWNs apply for additional channels.
WWN 0 all adapters
WWN 1: 44ES, 42ES, 42XS
WWN 2 44ES WWN 3 44ES

Installation

CAUTIONCAUTION
Celerity FC host adapters contain components that are sensitive to electrostatic discharge (ESD). ESD can cause damage to the Celerity FC host adapter. Please follow standard methods to avoid ESD.
1 Install the latest drivers. Refer to Installing and
updating drivers on page 11.
2 Power down the computer and unplug the
computer from all power sources.
3 Open the case.
4
Install the Celerity FC host adapter in any open
PCI, PCI-X or PCI Express expansion slot. If you have questions about how to install an expansion card in your system, consult your computer’s documentation.
Drawings of Celerity brackets begin on page 16 and drawings of boards begin on page 18.
Note
The Celerity FC-41XS, and FC-42XS host adapters only fit in 3.3V slots.
The Celerity FC-42ES, FC-41ES and FC-41EL fit into x4, x8, or x16 mechanical PCI Express slots.
If you have trouble seating your adapter in a 32­bit PCI bus computer, check to make sure the connector can accommodate 64-bit host adapters.
5 Connect Fibre Channel devices by inserting a
Fibre Channel cable from the devices to the connectors on the Celerity FC host adapter until you hear a click.
6 Close the case on the computer and power it
up.
15 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 19

Bracket details

Exhibit 4-1 FC-44ES Adapter

Exhibit 4-3 FC-41ES low profile, full height adapters

Exhibit 4-2 FC-42ES low profile, full height adapters

Exhibit 4-4 FC-41EL low profile, full height adapters

16
Page 20

Exhibit 4-5 FC-42XS low profile, full height adapters

Exhibit 4-7 FC-21PS Adapter

Exhibit 4-6 FC-41XS low profile, full height adapters

17 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 21

Adapter board details

Exhibit 4-8 FC-44ES

Exhibit 4-9 FC-42ES
SFP LC optical
connectors
FC controller
PCIe connector
18
Page 22
Exhibit 4-10 FC-41ES
SFP LC optical
connector
Exhibit 4-11 FC-41EL
FC controller
PCIe connector
SFP LC
optical
connector
PCIe connector
19 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 23
Exhibit 4-12 FC-42XS
Exhibit 4-13 FC-41XS
20
Page 24
Exhibit 4-14 FC-21PS
21 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 25

5 Updating hardware flash

Your Celerity FC host adapter was flashed before shipment, but the flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt. Visit the ATTO website,
www.attotech.com
, to download the latest drivers and flash bundle.
Hardware flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt.

Updating flash in all operating systems

1 Download the most recent version of the
Configuration Tool from the ATTO website.
Refer to the ATTO Utilities Installation and Operation Manual for additional information on downloading and using the Configuration Tool.
2 Download the proper flash bundle (adapter
specific) from the ATTO website.
3 Extract these files to your desktop.
4 Install the Configuration Tool on your system.
5 Launch the Configuration Tool.
6 In the Device window, select the adapter that
needs to be updated.
7 In the Flash window, click on the Browse
button to find the flash bundle that you previously downloaded to your desktop.
8 Click Update to update your flash ROM.
9 Reboot your system for the changes to take
effect.

Updating flash on a PC

You may update hardware flash on a PC using BIOS utilities.
Note
BIOS utilities do not work on Itanium systems. Use the ATTO Configuration Tool to update flash on Itanium systems.
1 Download the latest driver software from the
ATTO Technology website.
2 The download is a self-extracting executable
that expands the driver software package. Run the self-extracting executable and select a folder in which to place the expanded software package.
The expanded software package contains a Miniport driver and may contain a StorPort driver. The Celerity FC Windows Miniport driver is in the base directory of the expanded software package. The Celerity FC Windows StorPort driver is in the StorPort subdirectory.
3 Navigate to the folder with the desired Celerity
FC driver.
4Run makedisk.bat and follow the instructions
for creating the floppy disk.
Note
The flash update must be loaded from a floppy because CD-ROM drivers are not loaded at this point in the system boot process.
5 Reboot the PC.
6 During the reboot, an ATTO Technology
banner displays that the host adapter was detected.
7 Enter Control-F when prompted to begin the
set-up utility within a few seconds after the banner appears.
If you do not enter Control-F soon enough after the banner appears, repeat steps 5 and 6.
8 In the utility, select the Upgrade Flash ROM
option.
9 Insert the disk into the drive slot.
10 Follow the on-screen instructions.
11 Remove the disk and reboot your system for
the flash ROM changes to take effect
22
Page 26

6 Troubleshooting

This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website, authorized ATTO Technology representative.
www.attotech.com
, or contact an

General suggestions

• Check each cable connection on every device.
• Verify all cables are in proper working condition. Loose or broken cables are often the cause of errors or problems.

Mac OS X

Note
The Celerity FC supports Mac OS X versions
10.3 and later.
1 Open the ATTO Configuration Tool from the
ATTO Utilities CD or download from the ATTO website. Refer to the ATTO Utilities Installation and Operation Manual for additional information.
2 If the adapter does not appear in the Device
Listing, make sure it is properly seated in the PCI slot.
a. Remove power from the PC. b. Remove the case. c. Check the PCI slot. d. Replace the case. e. Apply power.
Note
If the Celerity adapter is properly seated and devices are still not accessible, contact an authorized ATTO representative.
• Check that Fibre Channel devices are plugged into an AC outlet and are turned on before you add power to your computer.
3 Verify the driver is loaded.
a. Click on the adapter name in the
Device Listing to view the Basic Info screen.
b. If the Driver Information section
indicates Unknown: driver not loaded, reinstall the driver. Refer to
Installing and updating drivers
11.
c. If reinstalling the driver does not fix the
problem, contact an authorized ATTO representative.
4 Reset the NVRAM for all channels to defaults
and reboot. If the problem persists, contact an authorized ATTO representative.
Note
When calling ATTO Technical Support, please have a printout of the IOreg listing and output from the Apple System Profiler available.
on page

Windows 2000/XP/Server 2003/Vista

• If the card has been recently re-flashed, the new Windows driver must be installed. Follow the procedure in Installing and updating drivers page 11.
• All of the external devices connected to the host adapter should be identified. If they do not appear in the Device Manager, the external devices or connection may not be working properly.
• For Intel-based PCs, check the computer CMOS setup and verify that the PCI slots are configured correctly.
23 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
on
• Procedures vary greatly: refer to the manual supplied with your system or call the computer supplier for configuration assistance.
• Windows 2000/XP/Server 2003/Vista are Plug­n-Play operating systems: be sure your computer’s BIOS is set accordingly.
• If these do not solve the problem, re-flash the host adapter and re-install the Windows 2000/XP/Server 2003/Vista driver. See
Installing and updating drivers
on page 11.
Page 27
If the devices connected to the Celerity FC host adapter are not accessible
1 Right-click My Computer.
2Select Properties.
3 Select the Hardware tab.
4Select Device Manager.
• If the Celerity FC host adapter does not appear under the SCSI and RAID controllers, remove power from the PC, open the case, and check that the Celerity FC adapter is properly seated in the PCI slot. Replace the case and apply power.

Linux

• If the adapter has been identified but there is an exclamation point (!) on the listing, right click on the listing and select Uninstall.
5 Reload the driver (see Installing and updating
drivers on page 11).
6 Reboot the system and repeat the installation
process.
7 If problems persist, contact your authorized
ATTO Technology representative.
1Verify the celerityfc driver is loaded with the
lsmod
command. If lsmod does not show the driver, refer to the installation instructions to install and load the driver in Installing and
updating drivers on page 11.
2 Check the system log with the command
dmesg
messages during initialization. Make sure that all installed cards are properly detected and initialized.
. The celerityfc driver creates status
3 Examine the contents of the file(s)
/proc/scsi/celerityfc/X, where X is the adapter’s host number. This file contains details such as link status, connection speed and discovered devices.
Note
Advanced users only. Modify the
makefile
Upon loading, the detailed debugging information which may help troubleshoot the problem.
to enable debugging information.
celerityfc driver
driver
displays
24
Page 28

Appendix A Standards and compliances

The equipment described in this manual generates and uses radio frequency energy. The Technical Specification sheet for a particular Celerity FC host adapter lists certifications for that model.

FCC standards: radio and television interference

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help

Canadian standards

This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

European standards

Declaration of Conformity

This following statement applies to the Celerity FC host adapter.
This device has been tested in the basic operating configuration and found to be compliant with the following European Union standards: Application of Council Directive: 89/336/EEC
Standard(s) to which conformity is declared: EN55024:2002; EN55022:2002 CLASS B
This Declaration will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant.
Some ATTO Celerity cards comply with Directive 2002/95/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO representative regarding RoHS compliant products.
i ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 29
The following apply to the Celerity FC-42XS host adapter only:
ii
Page 30

Appendix B Accessories

The following Fibre Channel accessories are available through ATTO Technology and authorized resellers. Contact an ATTO Technology authorized sales representative to order.

Optical Cables

CBL-FCFI-05x5 m. cable– Duplex 50 Micron Multi-mode FC/Optical CBL-LCSC-0033 m. 50/125 optical cable (LC to SC) CBL-LCSC-01010 m. 50/125 optical cable (LC to SC)
A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information.

Fibre Channel and iSCSI solutions

ATTO FibreBridgeTMFibre Channel-to-SCSI bridge ATTO iPBridge iSCSI to SCSI, iSCSI to Fibre Channel bridges

SCSI solutions

ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix C)

SAS/SATA Solutions

ATTO ExpressSAS family of SAS Adapters (see Appendix D)

Software

ATTO Utilities Configuration and management software ATTO ExpressStripe Mac OS X RAID and benchmark software ATTO Express Power CenterWindows-based striping utility
iii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 31

Appendix C SCSI adapter selection guide

Ultra 320 SCSI
Product Features
Max. transfer rate (MB/sec.) 640 640 640 320 Low Voltage Differential
Single-ended SCSI
Number of SCSI Channels
Number of SCSI IDs supported
Low profile
Large file transfers
Cable distances (m)
32-bit PCI compatible
64-bit PCI compatible
33 MHZ PCI
133 MHZ PCI-X
66 MHz PCI
x4 PCI Express
Windows 2000/XP, Server 2003/Vista support
Linux support
Mac OS X support
Novell Netware support
RoHS compliant
UL5D UL5D LP UL4D UL4S
• • • •
• • • •
2/2 0/2 2/2 1/1
30 30 30 30
• • • •
12.5 12.5 12.5 12.5
• •
• •
• •
• •
• •
• •
• • • •
• • • •
• • • •
• • • •
• • • •
iv
Page 32

Appendix D SAS adapter selection guide

Product Features
Max.transfer rate
x8 PCI Express
Number of ports
Port configuration external/internal
Connector type
Number of devices supported
1.5 Gb SATA support
3 Gb SATA II support
3 Gb SAS support
Cable distances
Integrated RAID
RAID Management Utility
Global Hot Spares
Event notification
Memory (ECC)
Advanced Data Streaming™
Battery backup
32-bit support
64-bit support
Windows 2000/CP, Server 2003/Vista support
Linux (Red Hat, SUSE) support
Mac OS X support
RoHS compliant
Low profile
1
Performance ceiling constrained by PCIe bus transfer speed
2
Future support
1
(full duplex)
user selectable 4/4 or 0/8
1 mini SAS (x4) SFF-8088 external
2 mini SAS (x4) SFF-8087 internal
64 SAS/SATA targets
128 virtual devices
0, 1, 4, 5, 62, 10, 50, 602, JBOD,
E-mail, pop-up, log file E-mail, pop-up, log file
258 MB standard
512 upgradeable (OEM)
ATTO ExpressSAS RAID Adapters
R348 R380
4 GB/sec. 4 GB/sec.
• •
88
4/8
• •
• •
• •
up to 8m up to 8m
DVRAID
• •
• •
• •
optional optional
• •
• •
• •
• •
• •
• •
• •
8/0
2 mini SAS (x4) SFF-8088 external
64 SAS/SATA targets
128 virtual devices
0, 1, 4, 5, 62, 10, 50, 602, JBOD,
DVRAID
258 MB standard
512 upgradeable (OEM)
v ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Page 33

Appendix E Safety, warranty, contacts

All ATTO host adapter products have been tested to meet applicable safety standards when operated in proper electrical and thermal environments.

Safety

Please review the specifications for your specific host adapter before installing and operating it in any computer system to ensure compatibility.

Installation

Before installing an ATTO host adapter product into your computer system, unplug the computer from its electrical power source and allow adequate time for electrical discharge and the internal components to cool down before removing the computer system cover. This will decrease the risk of personal injury from electrical shock or touching the hot surface of an electrical component.
Once an ATTO host adapter is installed in a computer system, the computer cover must be reinstalled properly before turning the computer system back on.

Operation

ATTO host adapters require adequate cooling to function properly. If you have any questions as to the airflow provided by your computer system, please refer to your computer system manual or contact your computer system manufacturer.
To facilitate proper air circulation, ATTO host adapters should never be operated in a computer system without the cover installed or with an inoperable fan as this may cause safety or thermal problems which could damage the ATTO host adapter and void the warranty.

ATTO Technology, Inc. limited warranty

ATTO Technology, Inc. warrants to the original purchaser of this product that it is free from defects in material and workmanship as described in the ATTO Technology website,
ATTO Technology, Inc. liability shall be limited to replacing or repairing, at its option, any defective product. There is no charge for parts or labor should ATTO Technology, Inc. determine that this product is defective.
Products which have been subject to abuse, misuse, alteration, neglected, or have been serviced, repaired or installed by unauthorized personnel shall not be covered under this warranty provision. Damage resulting from incorrect connection or an inappropriate application of this product shall not be the responsibility of ATTO Technology, Inc. Liability is limited to ATTO Technology, Inc.product(s); damage to other equipment connected to ATTO Technology, Inc.product(s) is the customer’s responsibility.
This warranty is made in lieu of any other warranty, express or implied. ATTO Technology, Inc. disclaims any implied warranties of merchantability or fitness for a particular purpose.
www.attotech.com
.
vi
Page 34
ATTO Technology, Inc. responsibility to repair or replace a defective product is the sole and exclusive remedy provided to the customer for breech of this warranty. ATTO Technology, Inc. is not liable for any indirect, special, incidental, or consequential damages irrespective of whether ATTO Technology, Inc. has advance notice of the possibility of such damages.
No ATTO Technology, Inc. dealer, agent or employee is authorized to make any modification, extension or addition to this warranty.
vii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Loading...