Appendix A Standards and compliances ............................................i
FCC standards: radio and television interference
Canadian standards
European standards
Declaration of Conformity
Usage restrictions
Appendix B Accessories .......................................................................iii
Appendix C SCSI adapter selection guide ..........................................iv
Appendix D Contact ATTO Technology, Inc. ......................................v
1ATTO provides Fibre Channel solutions
The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and
scalability. Celerity FC storage adapters simplify advanced storage networking needs such as
switching, backup and data management. Specifically designed to enhance the functionality of third
party fabric hardware and software, Celerity FC products are the industry-leading platform for storage
connectivity
Celerity FC-42ES Adapter
The Celerity FC-42ES is a dual-channel storage
adapter, providing port density for Enterprise
server and workstation applications. The FC42ES leverages two next-generation storage
technologies: PCI Express interconnect and 4Gigabit Fibre Channel. With 4-Gb FC speeds of
up to 800 MB/second per channel, the FC-42ES
supports the most demanding application
requirements, including high-definition video,
rich content databases and other high-bandwidth
environments.
Additionally the FC-42ES takes advantage of the
latest in host interconnect technology, PCI
Express, a serial, high-speed connection that
supports aggregate throughput up to 2 GB/second
(x8 PCIe). The FC-42ES is software compatible
with existing PCI and PCI-X products using the
same device drivers as the other Celerity FC
family products, simplifying user installation and
support.
The Celerity FC-42ES is backward compatible
with existing 2-Gb and 1-Gb Fibre Channel
infrastructure, protecting existing technology
investments.
Hardware specifications
• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex
throughput per channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports Target and Initiator modes
• Supports Windows
• Supports Exclusive Advanced Data Streaming
(ADS
TM
) Technology
®
FDMI and WMI
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
Interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI to PCI/PCI-X Bridge spec 1.0
Environmental & physical specifications
• Conforms to PCI standard height, half length
form-factor specifications
• Length: 6.525 inches
• Height: 3.81 inches
• Operating Temperature: 0-45ºC (32º-113ºF)
• Storage Temperature: -40º to 70ºC (-40º to
158ºF)
• Relative Humidity: 5 to 95% non-condensing
• 12V@ .035A (max.)
• 3.3V @ 1.42A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
1 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual
• External LEDs for on-line and speed status for
each channel
• Two pluggable optical LC SFP transceivers
included
Celerity FC-44ES Adapter
Software specifications
• Windows XP, 2000 and Server 2003
• Red Hat Linux
•SUSE
®
Linux (2.6 kernel)
®
(2.4 and 2.6 kernel)
The Celerity FC-44ES leverages two nextgeneration storage technologies: PCI Express
Interconnect and 4-Gigabit Fibre Channel.
With 4-Gb FC speeds of up to 800 MB/sec. per
channel, the FC-44ES supports the most
demanding application requirements, including
high-definition video, rich content databases and
other high bandwidth environments.
The FC-44ES takes advantage of the latest in host
interconnect technology, PCI Express, a serial,
high-speed connection that supports aggregate
throughput up to 2.2 GB/sec. (x8PCIe). With
software compatible with existing PCI and PCI-X
products, the FC-44ES uses the same device
drivers as the other Celerity FC family products,
simplifying installation and support.
Hardware specifications
• Four independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports Target and Intitiator modes
• Supports Windows
• Supports Exclusive Advanced Data Streaming
(ADS
TM
) Technology
FDMI and WMI
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
Interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI to PCI/PCI-X Bridge spec 1.0
Environmental & physical specifications
• Conforms to PCI standard height, half length
form-factor specifications
• Length: 6.525 inches
• Height: 3.81 inches
• Operating Temperature: 0-45ºC (32º-113ºF)
• Storage Temperature: -40º to 70ºC (-40º to
158ºF)
• Relative Humidity: 5 to 95% non-condensing
• 12V@ 2.1A (max.)
• 3.3V @ 3.0A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for
each channel
• Four pluggable optical LC SFP transceivers
included
Software specifications
• Windows XP, 2000 and Server 2003
• Red Hat Linux
• SUSE Linux (2.6 kernel)
(2.4 and 2.6 kernel)
2
Celerity FC-42XS Adapter
The dual-channel Celerity FC-42XS storage
adapter provides the highest available throughput
for Fibre Channel applications while protecting
technology investments via backward
compatibility with existing infrastructure.
With speeds of up to 800 MB/sec. per channel,
the FC-42XS is capable of supporting the most
intensive data applications, including digital
content creation, tape streaming and backup, rich
content delivery and complete database
environments.
To ensure a smooth transition path, the FC-42XS
leverages the existing Celerity FC software
hardware architecture, allowing ATTO to deliver
industry-leading quality and stable software
architecture.
Hardware specifications
• Two independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports Target and Intitiator modes
• Supports Windows
• Exclusive Advanced Data Streaming (ADS
Technology
FDMI and WMI
TM
)
Environmental & physical specifications
• Conforms to PCI low profile form factor
standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating Temperature: 0-45ºC (32º-113ºF)
• Storage Temperature: -40º to 70ºC (-40º to
158ºF)
• Relative Humidity: 5 to 95% non-condensing
• 5V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for
each channel
• Two optical LC SFP transceivers included
PCI bus specifications
• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only
3 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
•Mac
®
OS X
Celerity FC-41XS Adapter
The single-channel Celerity FC-41XS is the nextgeneration of ATTO advanced storage
connectivity solutions, leveraging the latest in
storage technology: 4-Gigabit Fibre Channel.
With speeds of up to 800 MB/sec., the FC-41XS
is capable of supporting the most data-intense
applications such as digital content creation, tape
streaming, backup rich content delivery and
complex database environments. Additionally the
FC-41XS leverages existing Celerity FC software
and hardware architectures, allowing ATTO to
deliver cutting-edge performance with top-notch
quality and design stability. Providing costeffective connectivity for client and server
applications alike, the FC-41XS offers full 4Gigabit performance as well as full backward
compatibility with existing 2-Gb and 1-GB Fibre
Channel infrastructure, protecting existing
technology investments.
Hardware specifications
• One Fibre Channel port
• 4-Gigabit FC data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput.
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• Exclusive Advanced Data Streaming (ADS
Technology
FDMI and WMI
TM
PCI bus specifications
• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only
Environmental & physical specifications
• Conforms to PCI low profile form factor
standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating Temperature: 0-45ºC (32º-113ºF)
• Storage Temperature: -40º to 70ºC (-40º to
158ºF)
• Relative Humidity: 5 to 95% non-condensing
• 5V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status
• One optical LC SFP transceiver included
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X
)
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic
negotiation among 4-Gb, 2Gb and 1-Gb Fibre Channel
• Supports Target and
Intitiator modes
4
Celerity FC-21PS Adapter
The Celerity FC-21PS Fibre Channel Storage
Adapter provides a single 2-Gb Fibre Channel
connection from host devices to the Storage Area
Network (SAN) fabric.
The FC-21PS supports the leading operating
systems, providing a single solution for all
connectivity needs. As with all Celerity FC
products, the FC-21PS is designed for highquality data transmission, ensuring that critical
information is delivered correctly the first time to
reduce fabric traffic and improve overall fabric
efficiency.
Hardware specifications
• One Fibre Channel port
• 400 MB/sec. throughput in full duplex mode
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• On-demand, automatic negotiation between 2Gb and 1-Gb Fibre Channel
• Supports Target and Intitiator modes
• Supports Windows
• Exclusive Advanced Data Streaming (ADS
Technology
PCI bus specifications
• 64-bit/32-bit, 66/33 MHz PCI compatible
• PCI 2.3 compliant
• 3.3V and 5V PCI signaling with universal
connector
FDMI and WMI
TM
)
Environmental & physical specifications
• Conforms to PCI low profile form factor
standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating Temperature: 0-45ºC (32º-113ºF)
• Storage Temperature: -40º to 70ºC (-40º to
158ºF)
• Relative Humidity: 5 to 95% non-condensing
• 5V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• Integrated optical LC SFF fixed transceiver
• External LEDs for on-line and speed status
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X
5 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual
Celerity FC-22XH
The Celerity FC-22XH is a Fibre Channel storage
adapter which uses embedded hub technology to
provide four external connections to two
independent FC channels. The hub technology
helps simplify SAN fabric design and provides
more capabilities than found in a typical adapter.
The FC-22XH allows you to solve cost and
configuration issues in workgroup and complex
SAN designs. Several users may share Fibre
Channel connections to maximize the value of
each channel without the added expense of using
additional adapters or PCI expansion slots. The
FC-22XH design provides reduced total cost of
ownership (TCO).
These capabilities are provided without
sacrificing link quality. The onboard hub digitally
retimes all signals to reduce jitter (poor signal
quality) to attached devices. Port bypass circuitry
automatically detours around unused or
malfunctioning ports.
Hardware specifications
• Four external ports connect to two independent
FC channels
• 2.125-Gigabit data transfer rates per channel
• 400 MB/sec. maximum full duplex throughput
per channel, shared between ports
connected to each channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point