ATTO Technology FastFrame NS12, FastFrame NS14, FastFrame NS11, FastFrame NT12, FastFrame NT11 Installation And Operation Manual

ATTO FastFrame Network Interface Adapter
Installation and Operation Manual
FastFrame NS14
10GbE Quad Port PCIe 2.0 Network Interface Adapter
FastFrame NS12
10GbE Dual Port PCIe 2.0 Network Interface Adapter
FastFrame NS11
10GbE Single Port PCIe 2.0 Network Interface Adapter
FastFrame NT12
FastFrame NT11
10GBASE-T Single Port PCIe 2.0 Network Interface Adapter
ATTO Technology, Inc.
155 CrossPoint Parkway Amherst, New York 14068 USA
www.attotech.com
Tel (716) 691-1999 Fax (716) 691-9353
Sales support: sls@attotech.com Technical support: Monday -- Friday, 8am-6pm EST
techsupp@attotech.com (716) 691-1999 ext. 242
© 2012 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
10/2012
.......................................... ...... ......... ....... .............. ................. ........ ,,,,,,,,,,,, ,, ,,,,,,,,,,,,,,,,,,,,,
PRMA-0437-000MD
Contents
1 ATTO FastFrame NIC Features & Overview ....................................................1
Getting started FastFrame NS14 Adapter FastFrame NS12 Adapter FastFrame NS11 Adapter FastFrame NT12 Adapter FastFrame NT11 Adapter
2 Hardware Installation .........................................................................................8
3 Install Drivers .....................................................................................................14
4 Updating Drivers ................................................................................................16
5 Troubleshooting .................................................................................................17
General suggestions Windows Server 2012, 2008, 2003; Windows 8, 7, Vista Linux Mac OS X
Appendix A Glossary ............................................................................................i
Appendix B Accessories ......................................................................................iii
Appendix C ATTO Adapter Selection Guides ....................................................iv
Appendix D Standards, Compliances .................................................................viii
FCC standards: radio and television interference Compliances
Appendix E Safety, Warranty ...............................................................................xi
Safety ATTO Technology, Inc. limited warranty
1 ATTO FastFrame NIC Features & Overview
Note
FastFrame 10Gb Ethernet NICs provide flexible and scalable unified LAN and SAN storage connectivity.
Built on industry-leading Intel® silicon for universal usability, ATTO FastFrame NICs lead in high performance I/O connectivity for Mac OS X environments while offering broad support for Windows and Linux server and workstation operating systems. They provide reliable, inexpensive, fast network access to block storage via iSCSI, with lossless Ethernet (CEE) and Data Center Bridging (DCB) for improved iSCSI quality of service. ATTO FastFrame NICs comprise a full range of products for flexible design—single, dual, and quad-port configurations, as well as support for Direct Attach Copper.
New to the FastFrame family, ATTO FastFrame 10GBASE-T NICs operate with existing structured shielded or unshielded twisted pair copper cabling familiar to network professionals.
Getting started
In general, to install the ATTO Network Interface Adapter, you must:
1 Ensure you have the equipment and software
you need for the installation:
• FastFrame NIC
• ATTO FastFrame NIC drivers
• OS X driver can be found on the FastFrame NIC Installation CD
• Windows and Linux drivers must be downloaded. Refer to Install Drivers page 14.
• A computer with an available expansion slot
on
Strong reseller & OEM programs plus exceptional support provided by ATTO make the FastFrame line of NICs the choice for system builders seeking a lasting footprint in storage-intensive and data center markets.
• Extensively tested and optimized by ATTO for high-performance in Media & Entertainment applications, as well as applications with similar profiles such as medical imaging, and oil & gas
• 10GbE cards, ports & cabling are backwards compatible to Gig-E for staged upgrades or future-proofing— and you can run 10GBASE-T NICs with Cat6a cabling that’s already in place
• 30% lower power rating means lower energy costs, lower data center maintenance fees, and less heat to dissipate
2 Install the FastFrame Adapter. Refer to
Hardware Installation
3 Install drivers for your operating system. Refer
to Install Drivers
4 Attach your NIC to a switch or server using an
ATTO recommended cable:
Optical (NS14, NS12, NS11)
• CBL-LCLC-R03 (3 Meter)
• CBL-LCLC-R10 (10 Meter)
10GBASE-T (NT12, NT11)
• CAT6a
on page 8.
on page 14.
Install your FastFrame NIC into a PCIe 2.0 x8 expansion slot for best performance
• Storage, cables and connectors
http://www.attotech.com/products/cable-finder/
1
FastFrame NS14 Adapter
FastFrame's comprehensive, easy-to-understand portfolio includes single-, dual-, and quad-port adapters with included high-quality SFP+ connectors ­a hidden cost with some competitor cards - and support for direct attach copper cables. Quad-port adapters conserve PCI slots for more flexible system design. FastFrame™ draws up to 60% less power than competing solutions. A lower power rating means lower energy costs, lower data center maintenance fees, and fewer worries about heat dissipation. In addition to wide support for Windows and Linux server and desktop operating systems, ATTO leads in high performance I/O connectivity for Mac OS X environments.
Host bus specifications
• x8 mechanical and x8 electrical PCI Express interconnect
• Conforms to PCI Express Base Spec 2.0
• Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 6.52 inches
• Height: 4.375 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 15.7 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket
• External LEDs for on-line and speed status for each port
• Four pluggable optical LC SFP+ modules included
Technical specifications
• Simultaneously supports multiple networking and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput for critical applications
• Supports Data Center Bridging; Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and DCB Exchange (DCBX) protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s
• Jumbo frame support up to 9,000 bytes
• Tx/Rx IP, TCP & UDP checksum offloading (IPv4, IPv6) capabilities, Transmission control protocol (TCP), User datagram protocol (UDP), Internet protocol (IP)
• Large send offloads (LSO)
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• openSUSE
• Fedora
TM
TM
13 & 14
11.2 & 11.3
5.x
6.x
2 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
FastFrame NS12 Adapter
FastFrame's comprehensive, easy-to-understand portfolio includes single-, dual-, and quad-port adapters with included high-quality SFP+ connectors ­a hidden cost with some competitor cards - and support for direct attach copper cables. FastFrame™ draws up to 60% less power than competing solutions. A lower power rating means lower energy costs, lower data center maintenance fees, and fewer worries about heat dissipation. In addition to wide support for Windows and Linux server and desktop operating systems, ATTO leads in high performance I/O connectivity for Mac OS X environments.
Technical specifications
• Simultaneously supports multiple networking and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput for critical applications
• Supports Data Center Bridging; Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and DCB Exchange (DCBX) protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s
• Jumbo frame support up to 9,000 bytes
• Tx/Rx IP, TCP & UDP checksum offloading (IPv4, IPv6) capabilities, Transmission control protocol (TCP), User datagram protocol (UDP), Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• x8 mechanical and x8 electrical PCI Express interconnect
• Conforms to PCI Express Base Spec 2.0
• Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 5.9 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket; low-profile bracket included in finished goods packaging
• External LEDs for on-line and speed status for each port
• Two pluggable optical LC SFP+ modules included
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• openSUSE
• Fedora
TM
TM
13 & 14
11.2 & 11.3
5.x
6.x
3
FastFrame NS11 Adapter
FastFrame's comprehensive, easy-to-understand portfolio includes single-, dual-, and quad-port adapters with included high-quality SFP+ connectors ­a hidden cost with some competitor cards - and support for direct attach copper cables. FastFrame™ draws up to 60% less power than competing solutions. A lower power rating means lower energy costs, lower data center maintenance fees, and fewer worries about heat dissipation. In addition to wide support for Windows and Linux server and desktop operating systems, ATTO leads in high performance I/O connectivity for Mac OS X environments.
Technical specifications
• Simultaneously supports multiple networking and storage protocols: FCoE, TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput for critical applications
• Supports Data Center Bridging; Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and DCB Exchange (DCBX) protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Host bus specifications
• x8 mechanical and x8 electrical PCI Express interconnect
• Conforms to PCI Express Base Spec 2.0
• Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 4.7 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket; low-profile bracket included in finished goods packaging
• External LEDs for on-line and speed status for each port
• Pluggable optical LC SFP+ module included
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• openSUSE
• Fedora
TM
TM
13 & 14
11.2 & 11.3
5.x
6.x
Ethernet features
• Data rate per port: 10Gb/s
• Jumbo frame support up to 9,000 bytes
• Tx/Rx IP, TCP & UDP checksum offloading (IPv4, IPv6) capabilities, Transmission control protocol (TCP), User datagram protocol (UDP), Internet protocol (IP)
• Large send offloads (LSO)
4 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
FastFrame NT12 Adapter
Built on industry-leading Intel® silicon for universal usability, ATTO FastFrame NICs lead in high performance I/O connectivity for Mac OS X environments while offering broad support for Windows and Linux server and workstation operating systems. They provide reliable, inexpensive, fast network access to block storage via iSCSI, with lossless Ethernet (CEE) and Data Center Bridging (DCB) for improved iSCSI quality of service. New to the FastFrame family, ATTO FastFrame 10GBASE-T NICs operate with existing structured shielded or unshielded twisted pair copper cabling familiar to network professionals. 10GbE cards, ports & cabling are backwards compatible to Gig-E for staged upgrades or future-proofing— and you can run 10GBASE-T NICs with Cat6a cabling that’s already in place.
• Tx/Rx IP, TCP & UDP checksum offloading (IPv4, IPv6) capabilities, Transmission control protocol (TCP), User datagram protocol (UDP), Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• x8 mechanical and x8 electrical PCI Express 2.0 interconnect
• Backward compatible with PCI Express 1.1
• Supports PCI Express Base Spec 2.0
• Supports PCI Express CEM Spec 2.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 13.6W (typical), 16.0W (max)
• 200 lf/m (minimum) airflow recommended
• RoHS compliant
Technical specifications
• Intel X540 10GBASE-T Ethernet Controller
• Simultaneously supports multiple networking and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput for critical applications
• Supports Data Center Bridging; Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and DCB Exchange (DCBX) protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s, 1Gb/s, 100Mb/s
• Jumbo frame support up to 9,000 bytes
External connectivity
• Easy to install full height connection bracket; low-profile bracket included in finished goods packaging
• External LEDs for link speed and activity for each port
• Compatible with CAT-7, CAT-6a, and CAT-6 Ethernet cables for 10GBASE-T connections and CAT-5e for 1000BASE-T and 100BASE-TX connections
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• SUSE Linux Enterprise® Server 11 SP1
• Fedora
• CentOS 5 & 6
TM
13 & 14
5.x
6.x
5
FastFrame NT11 Adapter
Built on industry-leading Intel® silicon for universal usability, ATTO FastFrame NICs lead in high performance I/O connectivity for Mac OS X environments while offering broad support for Windows and Linux server and workstation operating systems. They provide reliable, inexpensive, fast network access to block storage via iSCSI, with lossless Ethernet (CEE) and Data Center Bridging (DCB) for improved iSCSI quality of service. New to the FastFrame family, ATTO FastFrame 10GBASE-T NICs operate with existing structured shielded or unshielded twisted pair copper cabling familiar to network professionals. 10GbE cards, ports & cabling are backwards compatible to Gig-E for staged upgrades or future-proofing— and you can run 10GBASE-T NICs with Cat6a cabling that’s already in place.
• Tx/Rx IP, TCP & UDP checksum offloading (IPv4, IPv6) capabilities, Transmission control protocol (TCP), User datagram protocol (UDP), Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• x8 mechanical and x8 electrical PCI Express 2.0 interconnect
• Backward compatible with PCI Express 1.1
• Supports PCI Express Base Spec 2.0
• Supports PCI Express CEM Spec 2.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 13.6W (typical), 16.0W (max)
• 200 lf/m (minimum) airflow recommended
• RoHS compliant
Technical specifications
• Intel X540 10GBASE-T Ethernet Controller
• Simultaneously supports multiple networking and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput for critical applications
• Supports Data Center Bridging; Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and DCB Exchange (DCBX) protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s, 1Gb/s, 100Mb/s
• Jumbo frame support up to 9,000 bytes
External connectivity
• Easy to install full height connection bracket; low-profile bracket included in finished goods packaging
• External LEDs for link speed and activity for each port
• Compatible with CAT-7, CAT-6a, and CAT-6 Ethernet cables for 10GBASE-T connections and CAT-5e for 1000BASE-T and 100BASE-TX connections
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• SUSE Linux Enterprise® Server 11 SP1
• Fedora
• CentOS 5 & 6
TM
13 & 14
5.x
6.x
6 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Selection guide: FastFrame adapters
Product Features FFRM-NS14 FFRM-NS12 FFRM-NS11 FFRM-NT12 FFRM-NT11
Ports 42121
Maximum Transfer Rate (Full Duplex) 8GB/s 5GB/s 2.5GB/s 5GB/s 2.5GB/s
Maximum Transfer Rate (Half Duplex) 4GB/s 2.5GB/s 1.25GB/s 2.5GB/s 1.25GB/s
Bus type PCIe 2.0 PCIe 2.0 PCIe 2.0 PCIe 2.0 PCIe 2.0
Bus characteristics 8 lane 8 lane 8 lane 8 lane 8 lane
Optical/Copper interface SFP+LC SFP+LC SFP+ LC RJ45 RJ45
Maximum cable length
Low profile form factor
Advanced Data Streaming (ADS™) Technology
Windows support
Mac OS driver support
Linux driver support
Cable length varies by interface and cable type.
Interface Cable type Max Distance
10GBASE-SR 62.5/125 µm multi-mode fiber (OM1) 26m 10GBASE-SR 50/125 µm MMF (OM2) 82m 10GBASE-SR Laser optimized 50/125 µm MMF (OM3) 300m
10GBASE-T CAT-7 100m 10GBASE-T CAT-6a 100m 10GBASE-T CAT-6 55m 1000BASE-T CAT-5e 100m 100BASE-TX CAT-5e 100m
See Chart
Below
   
See Chart
Below
See Chart
Below
See Chart
Below
See Chart
Below

7
2 Hardware Installation
CAUTIONCAUTION
Note
CAUTIONCAUTION
Note
Install the ATTO FastFrame Adapter and attach your devices to it using the instructions below.
The assignment will be as follows:
Back up your system data before changing or installing any hardware.
System requirements
The FastFrame NIC package contains the following:
• FastFrame Network Interface Adapter
• ATTO Utilities CD
• Warranty and registration card
• SFP+ Modules (NS adapters only)
If any of these items are missing, contact your ATTO authorized sales representative.
To install and use the FastFrame NIC you will need:
1 A computer with an available PCI Express
expansion slot
Install your FastFrame NIC into a PCIe 2.0 x8 expansion slot for best performance
2 The complete FastFrame NIC package
MAC address
FastFrame NICs are configured with a unique MAC address designated by the Institute of Electrical and Electronic Engineers. This address, stored in flash memory, allows the system to recognize the FastFrame NIC as a unique part of your configuration. The address is clearly marked on the back of the adapter.
The MAC address assigned to an adapter is assigned to the 1st port of the adapter. If the adapter has more than one port then MAC address is incremented by and assigned to the 2nd port, incremented by 2 and assigned to the 3rd port and incremented by 3 and assigned to the 4th port.
MAC address 1st port of NS11, NS12 & NS14 MAC address + 1 2nd port of NS12 & NS14 MAC address + 2 3rd port of NS14 MAC address + 3 4th port of NS14
Installation
FastFrame NICs contain components that are sensitive to electrostatic discharge (ESD). ESD can cause damage to the FastFrame host adapter. Please follow standard methods to avoid ESD.
For bracket installation, please see the bracket installation guide included in your NIC product package.
1 Install the latest drivers. Refer to Chapter 3 on
page 14.
2 Power down the computer and unplug the
computer from all power sources. 3 Open the case. 4 Remove the cover bracket from the PCI
Express slot (v1.0a or later). 5 Install the FastFrame NIC host adapter in any
open PCI Express expansion slot. If you have
questions about how to install an expansion
card in your system, consult your computer's
documentation.
The FastFrame adapters fit into x8 or x16 mechanical PCI Express slots.
6 Repeat step 4 through 5 for each adapter you
want to install. 7 Close the case on the computer and power it
up.
8 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Bracket details
Exhibit 2-1 FFRM-NS14 Bracket
Exhibit 2-3 FFRM-NS11
Full & Low Profile Bracket
Exhibit 2-2 FFRM-NS12 Full & Low Profile Bracket
9
Exhibit 2-4 FFRM-NT12 Full & Low Profile Bracket Exhibit 2-5 FFRM-NT11 Full & Low Profile Bracket
10 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Adapter board details
Exhibit 2-6 FFRM-NS14 board
Exhibit 2-7 FFRM-NS12
board
11
Exhibit 2-8 FFRM-NS11 board
Exhibit 2-9 FFRM-NT12 board
12 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Exhibit 2-10 FFRM-NT11 board
13
3 Install Drivers
Note
Note
Note
Before installing your FastFrame adapter, you must configure your system to recognize it by installing drivers for your operating system.
1 Download the latest install package from the
Intel support website at
If you already have one or more FastFrame adapters installed and you are installing additional adapter(s), you do not need to perform any of these procedures unless you are updating a previously installed driver.
The FastFrame NIC Installation CD, referred to in these instructions, is the Installation CD that shipped with your adapter. OS X and the manuals for the FastFrame products. It is recommended that the ATTO download page is checked to get the latest OS X driver. You must follow the directions below to get the installation package for the OS X operating system.
This CD does not include drivers for Windows or Linux operating systems. You must follow the directions below to get the driver installation packages for Windows and Linux operating systems.
This CD contains the drivers for
http://www.intel.com/p/en_US/support
transfer it to the system. 2 Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller.
The download files are the same and they are
appropriate for the FastFrame NIC controllers. 3 Select the version of Windows on which the
driver will run. Then select either the
ProWin32.exe or the ProWinx64.exe file based
upon the Windows installation of 32-bit or 64-
bit. 4 Download the file. 5 Start the installation by double clicking the
downloaded follow. 6 Follow the instructions to install the NIC driver.
and
Linux
Intel Website (NS14, NS12, NS11, NT12, NT11)
Windows
Intel Website (NS14, NS12, NS11, NT12, NT11)
Windows 8, 7, Vista, Server 2012 and 2008 may utilize a new User Account Control Feature. Because of this there may be additional confirmations that will need to be performed to properly install the driver. These confirmations normally consist of a dialog where the user has to give Windows permission to perform an action. If you do not have the correct privileges during this, you will be prompted for an actual user name and password. You may need to contact your system administrator if you do not have this information.
These steps assume a basic knowledge of Linux terminal commands. You must also have the correct kernel header files for the appropriate kernel already installed.
1 Download the latest install package from the
Intel support website at
http://www.intel.com/p/en_US/support
transfer it to the system. 2 Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller.
The download files are the same and they are
appropriate for the FastFrame NIC controllers. 3 Select the latest driver for Network Connections
under Linux. 4 Download the file. 5 There is a Read Me (txt) file that provides
instructions on building the Linux driver. Follow
those directions to install the NIC driver under
Linux.
and
14 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Mac OS X
ATTO Website (NS14, NS12, NS11, NT12, NT11)
1Go to http://www.attotech.com/downloads.html 2 Log in. First-time visitors will be required to
complete registration.
3 Under ‘Select Product’ choose Ethernet
Adapters. 4Select 10GbE Network Interface Cards. 5 Download the latest Mac driver. 6 Open the driver from the location in which it was
saved. 7 Follow the on-screen instructions.
Installation CD (NS14, NS12, NS11, NT12, NT11)
1 Power on your system and log in as the
administrator or a user with proper
administrative privileges. 2 Insert the Installation CD. 3 After the CD mounts, open the FastFrame
volume on the desktop. 4 Open the Drivers folder. 5 Open the folder corresponding to the OS X
version in use. 6 Launch the installer package. 7 Follow the on-screen instructions.
15
4 Updating Drivers
Your FastFrame NIC should ship with the latest flash and drivers, but these may need to be updated as new versions become available. Visit the ATTO website, www.attotech.com, to download the latest drivers and flash bundle.
Updating Windows drivers
1 Download the latest install package from the
Intel support website at
http://www.intel.com/p/en_US/support
transfer it to the system.
2 Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller. The download files are the same and they are appropriate for the FastFrame NIC controllers.
3 Select the version of Windows on which the
driver will run. Then select either the ProWin32.exe or the ProWinx64.exe file based upon the Windows installation of 32-bit or 64-
bit. 4 Download the file. 5 Start the installation by double clicking the
downloaded follow. 6 Follow the instructions to install the NIC driver.
and
Updating Linux drivers
1 Download the latest install package from the
Intel support website at
http://www.intel.com/p/en_US/support
transfer it to the system. 2 Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller.
The download files are the same and they are
appropriate for the FastFrame NIC controllers. 3 Select the latest driver for Network Connections
under Linux. 4 Download the file. 5 There is a Read Me (txt) file that provides
instructions on building the Linux driver. Follow
those directions to install the NIC driver under
Linux.
and
Updating OS X drivers
1Go to http://www.attotech.com/downloads.html 2 Log in. First-time visitors will be required to
complete registration.
3 Under ‘Select Product’ choose Ethernet
Adapters. 4Select 10GbE Network Interface Cards 5 Download the latest Mac driver. 6 Open the driver from the location in which it was
saved. 7 Follow the on-screen instructions.
16 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
5 Troubleshooting
Note
This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website, Technology representative.
General suggestions
www.attotech.com
, or contact an authorized ATTO
• Check each cable connection on every device.
• Verify all cables are in proper working condition. Loose or broken cables are often the cause of errors or problems.
• Check that connected devices are plugged into an AC outlet and are turned on before you add power to your computer.
Windows Server 2012, 2008, 2003; Windows 8, 7, Vista
• If working properly the NIC should appear in the Device Manager.
• If the FastFrame NIC does not appear under the Network Adapters:
a. Remove power from the PC. b. Open the case. c. Check that the FastFrame NIC adapter is
properly seated in the PCI slot.
d. Replace the case and apply power.
• If the adapter has been identified but there is an exclamation point (!) on the listing:
a. Right click on the listing and select
Uninstall.
b. Reload the driver (see Updating Windows
drivers on page 16.
c. Reboot the system and repeat the
installation process.
If problems persist, contact your authorized ATTO Technology representative.
Linux
1 Verify the FastFrame driver is loaded with the
lsmod command. If lsmod does not show the driver, refer to the installation instructions to install and load the driver in Updating Windows
drivers on page 16.
2 Check the system log with the command
dmesg. The FastFrame driver creates status messages during initialization. Make sure that all installed cards are properly detected and initialized.
3 Examine the contents of the file(s): /proc/scsi/
fastframe/x, where x is the adapter's host number. This file contains details such as link status, connection speed and discovered devices.
Advanced users only. Modify the
makefile
Upon loading, the displays detailed debugging information which may help troubleshoot the problem.
to enable debugging information.
FastFrame driver
driver
17
Mac OS X
Note
Note
Note
The ATTO FastFrame supports Mac OS X versions 10.6.x and later.
1 Open the ATTO ConfigTool from the ATTO
Utilities CD or download it from the ATTO website. Refer to the ATTO Utilities Installation and Operations Manual for additional information.
2 If the adapter does not appear in the System
Profiler, make sure the card is seated properly in the PCIe slot.
a. Shut down and remove power from the
Mac. b. Remove the side of the case. c. Check the PCIe slot d. Replace the side of the case. e. Apply power
If the Fastframe adapter is properly seated and devices are still not accessible check the cable to verify the link light is illuminated. If not contact an authorized ATTO representative.
3 Verify the driver is loaded.
a. Click on the adapter name in the Device
Listing to view the Basic Info screen.
b. If the Driver Information section indicates
Unknown: driver not loaded, reinstall the driver. Refer to Updating Hardware Flash Drivers on page 25.
c. If reinstalling the driver does not fix the
problem, contact an authorized ATTO representative.
4 Reset the NVRAM for all channels to defaults
and reboot. If the problem persists, contact an authorized ATTO representative.
When calling ATTO Technical Support please have a printout of the IOreg listing, Apple System Profiler, Serial number of the adapter, and what driver and firmware that is currently loaded in your Apple computer.
18 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Appendix A Glossary
Some terms used in the Network Interface industry are defined below. More information is available through the ATTO Technology website (
(
www.snia.org
Term Definition
ANSI American National Standards Institute BER Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent bit smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1 bus a collection of unbroken signal lines used to transmit information from one part of a computer
byte an ordered set of 8 bits channel a point-to-point link which transports data from one point to another CPU Central Processing Unit: the portion of the computer that actually performs computations CRC Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
device driver a program that allows a microprocessor to direct the operation of a peripheral device DMA Direct Memory Access: a way to move data from a storage device directly to RAM without using
DMA bus master allows a peripheral to control the flow of data to and from system memory by block as opposed to
full-duplex a communication protocol which allows transmission in both directions at the same time half duplex a communication protocol which allows transmission in both directions, but only one direction at a
host a processor, usually a CPU and memory, which communicates with devices over an interface initiator device a component which originates a command LED Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
LUN Logical Unit Number: an identifier for a logical unit (0-7) MAC Media Access Controller MAC Address A unique address assigned to an ethernet device multi-mode fiber an optical fiber which can carry several beams of light at once N_port a port attached to a node used with point to point or fabric configurations originator an initiating device; a component which originates a command parity checking a method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
PCI Peripheral Component Interconnect. Allows peripherals to be connected directly to computer
point-to-point a topology where two ports communicate port an access point in a device: see N_port, NL_port, etc. port address also port number; the address, assigned by the PCI bus, through which commands are sent to a
port number see port address receiver the ultimate destination of data transmission; a terminal device
).
system to another; taps on the lines connect devices to the bus
and transmitted data; if no error has occurred during transmission, the CRC for both received and transmitted data should be the same
the CPU’s resources
allowing the processor to control the data by bytes (PIO or programmed I/O)
time
are used as indicator lights on all sorts of electronic devices
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error message occurs if the sum is not correct
memory, bypassing the slower ISA and EISA busses
host adapter board
www.attotech.com
) and the Storage Area Networking Industry Association
i
Term Definition
scatter/gather a device driver feature which allows the host adapter to modify a transfer data pointer so that a
single host adapter can access many segments of memory, minimizing interrupts and transfer overhead
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source SNMP Simple Network Management Protocol: a standard for monitoring network-attached devices topology logical layout of the parts of a computer system or network and their interconnections transceiver a transmitter/receiver module transfer rate the rate at which bytes or bits are transferred, as in megabytes or gigabits per second
ii ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Appendix B Accessories
The following accessories are available through ATTO Technology and authorized resellers. Contact an ATTO Technology authorized sales representative to order.
Optical Cables
CBL-FCFI-05x5 m. cable – Duplex 50 Micron Multi-mode FC/Optical CBL-LCSC-0033 m. 50/125 optical cable (LC to SC) CBL-LCSC-01010 m. 50/125 optical cable (LC to SC)
A variety of Fibre Channel, SAS and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information.
Fibre Channel solutions
ATTO Celerity
TM
Family of Fibre Channel Host Adapters
SCSI solutions
ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix C)
SAS/SATA Solutions
ATTO ExpressSAS family of SAS Host and RAID Adapters (see Appendix C)
Software
ATTO ConfigTool – Configuration and management software ATTO Express Power Center – Windows & Mac OS X RAID 0 and benchmark software
iii
Appendix C ATTO Adapter Selection Guides
Contact your ATTO representative or visit the ATTO website for details on all ATTO products.
ExpressPCI SCSI host adapters
Ultra 320 SCSI
Product Features
Max. transfer rate (MB/sec.) 640MB/s 640MB/s 640MB/s Low Voltage Differential
Single-ended SCSI
Number of SCSI Channels (internal/external) 2/2 0/2 2/2 Number of SCSI IDs supported 30 30 30 Low profile
Large file transfers
Cable distances (m) 12.5 12.5 12.5 32-bit PCI compatible
64-bit PCI compatible
33 MHZ PCI
133 MHZ PCI-X
66 MHz PCI
x4 PCI Express
Windows 2000/XP, Server 2003/2008/Vista support
Linux support
Mac OS X support
Novell Netware support
RoHS compliant
UL5D UL5D LP UL4D
• • •
• • •
• • •
• •
• • •
• • •
• • •
• • •
• • •
iv ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
ExpressSAS 6 Gb Host Adapters
Product Features H6F0 GT H6F0 H60F H680 H608 H644
Max Data Rate 6Gb/s 6Gb/s 6Gb/s 6Gb/s 6Gb/s 6Gb/s x8 PCI Express • • • • • • Number of ports 16 16 16 8 8 8 Port configuration
external/internal Connector type 4 mini
16/0 16/0 0/16 8/0 0/8 4/4
SAS (x4)
SFF-8644
external
4 mini
SAS (x4)
SFF-8088
external
4 mini
SAS (x4)
SFF-8087
internal
2 mini
SAS (x4)
SFF-8088
external
2 mini
SAS (x4)
SFF-8087
internal
1 mini
SAS (x4)
SFF-8088
external
1 mini
SAS (x4)
SFF-8087
internal
Number of devices supported
1.5 Gb SATA support • • • • • • 3 Gb SATA II support • • • • • • 3 Gb SAS support • • • • • • 6 Gb SATA II support • • • • • • 6 Gb SAS support • • • • • • Software RAID 0 0 0 0 0 0 Cable distances up to 8m SAS,
Advanced Data Streaming™
32-bit support • • • • • • 64-bit support • • • • • • Windows • • • • • • Linux • • • • • • Mac OS X • • • • • • VMware • • • • • • Low profile • • • 1/2 height 1/2 height 1/2 height
2048
end-point
devices
1m SATA
• • • • • •
512
end-point
devices
up to 8m SAS,
1m SATA
512
end-point
devices
up to 8m SAS,
1m SATA
256
end-point
devices
up to 8m SAS,
1m SATA
256
end-point
devices
up to 8m SAS,
1m SATA
256
end-point
devices
up to 8m SAS,
1m SATA
v
ExpressSAS 6 Gb RAID Adapters
Product Features R60F R680 R608 R644
Max Data Rate 6Gb/s 6Gb/s 6Gb/s 6Gb/s x8 PCI Express • • • • Number of ports 16 8 8 8 Port configuration external/internal 0/16 8/0 0/8 4/4 Connector type 4 mini SAS (x4)
SFF-8087
internal
2 mini SAS (x4)
SFF-8088
external
2 mini SAS (x4)
SFF-8087
internal
1 mini SAS (x4)
SFF-8088
external
1 mini SAS (x4)
SFF-8087
internal
Number of devices supported 128 SAS/SATA
targets
1.5 Gb SATA support • • • • 3 Gb SATA II support • • • • 3 Gb SAS support • • • • 6 Gb SATA II support • • • • 6 Gb SAS support • • • • Software RAID 0, 40, 50, 60 0, 40, 50, 60 0, 40, 50, 60 0, 40, 50, 60 Integrated RAID 0, 1, 4, 5, 6
JBOD, DVRAID RAID Management Utility • • • • Global Hot Spares • • • • Event notification E-mail, pop-up,
log file SNMP • • • • Memory (ECC) 512 MB 512 MB 512 MB 512 MB Cable distances up to 10m SAS,
1m SATA Advanced Data Streaming™ • • • • 32-bit support • • • • 64-bit support • • • • Windows • • • • Linux • • • • Mac OS X • • • • Low profile • • • •
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10 SAS,
1m SATA
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10m SAS,
1m SATA
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10m SAS,
1m SATA
vi ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Celerity 8-Gb Adapters
Product Features FC-84EN FC-82EN FC-81EN
Fibre Channel Ports 4 2 1
FC protocol 8-Gb 8-Gb 8-Gb
Maximum Transfer Rate (Full Duplex) 6.4GB/s 3.2GB/s 1.6GB/s
Maximum Transfer Rate (Half Duplex) 3.2GB/s 1.6GB/s 800MB/s
Bus type PCIe 2.0 PCIe 2.0 PCIe 2.0
Bus characteristics 8 lane 8 lane 4 lane
Optical interface SFP+LC SFP+LC SFP+ LC
Maximum cable length 300m@2-Gb
150m@4-Gb
50m@8-Gb
Low profile form factor
Advanced Data Streaming (ADS™) Technology
Software RAID support
Developer's kit (Target Mode & API)
Windows support
Linux driver support
Macintosh OS X driver support
VMware driver support
1 ATTO Express Power Center recommended
1
      
300m@2-Gb 150m@4-Gb
50m@8-Gb
300m@2-Gb 150m@4-Gb
50m@8-Gb

vii
Appendix D Standards, Compliances
The Technical Specification sheet for each FastFrame CNA lists certifications for that model. Models covered by this page include the FastFrame FFRM-NS14, FFRM-NS12, FFRM-NS11, FFRM-NT12, FFRM-NT11
FCC standards: radio and television interference
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Canadian standards
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European standards
Declaration of Conformity
This following statement applies to all FastFrame adapter. This device has been tested in the basic operating configuration and found to be compliant with the
following European Union standards: Application of Council Directive: 2004/108/EC Standard(s) to
which conformity is declared: EN55024:2010; EN55022:2010 CLASS B. This Declaration will only be valid when this product is used in conjunction with other CE approved devices and
when the entire system is tested to the applicable CE standards and found to be compliant
Japanese standards
Voluntary Control Council for Interference by Information Technology Equipment (VCCI, Japan) This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information
Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.
viii ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Compliances
China RoHS Status Certifica te
中国 RoHS 认证概况
Table of Toxic and Hazardous Substances/Elements and their Content 有毒有害物质/成分及其含量表
Part Name
(部件名称)
Toxic and Hazardous Substances and Elements
Lead (Pb) 铅 Mercury (Hg)
Cadmium
(C d)
Hexavalent
Chromium (Cr6)
六价
Polybrominated
biphenols
(PBB)
溴联苯
Polybrominated di ph en yl ethers
(PBDE)
溴二苯醚
FFRM-NS14
Host B us Ad apte r
主机总线 适配器
X O O O O O
FFRM-NS12
Host B us Ad apte r
主机总线 适配器
X O O O O O
FFRM-NS11
Host B us Ad apte r
主机总线 适配器
X O O O O O
FFRM-NT12
Host B us Ad apte r
主机总线 适配器
X O O O O O
FFRM-NT11
Host B us Ad apte r
主机总线 适配器
X O O O O O
Notes 注意:
O: 表明该部件的所有同 种 材料中本有毒或有害物质 的含量低于 S J/T 1136 3- 20 06 标 准所要求的限量。
X: 表明该部件使用的同 种 材料中,至少有一种材料的有毒或有害物质 的含量超过了 SJ/T11363-2006 准所要求的限量。
ATTO FastFrame cards comply with Directive 2002/95/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO representative regarding RoHS compliant products.
The FastFrame family of adapters take the following RoHS exemptions:
7(a) - Lead in high melting temperature type solders (i.e. lead based alloys containing 85% by weight or more lead).
7(c)-I - Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in capacitors, (e.g. piezoelectronic devices, or in a glass or ceramic matrix compound).
7(c)-III - Lead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DC.
13(a) - Lead in white glasses used for optical applications.
15 - Lead in solders to complete a viable electrical connection between semiconductor die and carrier within integrated circuit flip chip packages.
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part i s below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materi als used for this part is above the limit require me nt in SJ/T 11 36 3 -20 0 6.
ix
The Environment-Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise marked. Certain fieldreplaceable parts may have a different EFUP (for example, battery modules) number. The Environment-Friendly Use
Per iod i s va lid on ly wh en th e produ ct is operated under the conditions defined in the product manual.
除非? 外特别的标注,此标志为针对所涉及产品的 环 保使用期限标志. 某些可更换的零 部件可能会有一个不同的环保使用期限(例如,电池单元模 块). 环 保使用期限只适用于产 品在 产 品手册中所 规 定的条件下工作.
x ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Appendix E Safety, Warranty
All ATTO host adapter products have been tested to meet applicable safety standards when operated in proper electrical and thermal environments.
Safety
Please review the specifications for your specific host adapter before installing and operating it in any computer system to ensure compatibility.
Installation
Before installing an ATTO host adapter product into your computer system, unplug the computer from its electrical power source and allow adequate time for electrical discharge and the internal components to cool down before removing the computer system cover. This will decrease the risk of personal injury from electrical shock or touching the hot surface of an electrical component.
Once an ATTO host adapter is installed in a computer system, the computer cover must be reinstalled properly before turning the computer system back on.
Operation
ATTO host adapters require adequate cooling to function properly. If you have any questions as to the airflow provided by your computer system, please refer to your computer system manual or contact your computer system manufacturer.
To facilitate proper air circulation, ATTO host adapters should never be operated in a computer system without the cover installed or with an inoperable fan as this may cause safety or thermal problems which could damage the ATTO host adapter and void the warranty.
ATTO Technology, Inc. limited warranty
ATTO Technology, Inc. warrants to the original purchaser of this product that it is free from defects in material and workmanship as described in the ATTO Technology website,
ATTO Technology, Inc. liability shall be limited to replacing or repairing, at its option, any defective product. There is no charge for parts or labor should ATTO Technology, Inc. determine that this product is defective.
Products which have been subject to abuse, misuse, alteration, neglected, or have been serviced, repaired or installed by unauthorized personnel shall not be covered under this warranty provision. Damage resulting from incorrect connection or an inappropriate application of this product shall not be the responsibility of ATTO Technology, Inc. Liability is limited to ATTO Technology, Inc.product(s); damage to other equipment connected to ATTO Technology, Inc.product(s) is the customer’s responsibility.
This warranty is made in lieu of any other warranty, express or implied. ATTO Technology, Inc. disclaims any implied warranties of merchantability or fitness for a particular purpose.
ATTO Technology, Inc. responsibility to repair or replace a defective product is the sole and exclusive remedy provided to the customer for breech of this warranty. ATTO Technology, Inc. is not liable for any indirect, special, incidental, or consequential damages irrespective of whether ATTO Technology, Inc. has advance notice of the possibility of such damages.