General suggestions
Windows Server 2012, 2008, 2003; Windows 8, 7, Vista
Linux
Mac OS X
Appendix A Glossary ............................................................................................i
Appendix B Accessories ......................................................................................iii
Appendix C ATTO Adapter Selection Guides ....................................................iv
Appendix D Standards, Compliances .................................................................viii
FCC standards: radio and television interference
Compliances
Appendix E Safety, Warranty ...............................................................................xi
Safety
ATTO Technology, Inc. limited warranty
1 ATTO FastFrame NIC Features & Overview
Note
FastFrame 10Gb Ethernet NICs provide flexible and scalable unified LAN and SAN storage connectivity.
Built on industry-leading Intel® silicon for universal
usability, ATTO FastFrame NICs lead in high
performance I/O connectivity for Mac OS X
environments while offering broad support for
Windows and Linux server and workstation operating
systems. They provide reliable, inexpensive, fast
network access to block storage via iSCSI, with
lossless Ethernet (CEE) and Data Center Bridging
(DCB) for improved iSCSI quality of service. ATTO
FastFrame NICs comprise a full range of products for
flexible design—single, dual, and quad-port
configurations, as well as support for Direct Attach
Copper.
New to the FastFrame family, ATTO FastFrame
10GBASE-T NICs operate with existing structured
shielded or unshielded twisted pair copper cabling
familiar to network professionals.
Getting started
In general, to install the ATTO Network Interface
Adapter, you must:
1Ensure you have the equipment and software
you need for the installation:
• FastFrame NIC
• ATTO FastFrame NIC drivers
• OS X driver can be found on the
FastFrame NIC Installation CD
• Windows and Linux drivers must be
downloaded. Refer to Install Drivers
page 14.
• A computer with an available expansion slot
on
Strong reseller & OEM programs plus exceptional
support provided by ATTO make the FastFrame line of
NICs the choice for system builders seeking a lasting
footprint in storage-intensive and data center markets.
• Extensively tested and optimized by ATTO for
high-performance in Media & Entertainment
applications, as well as applications with similar
profiles such as medical imaging, and oil & gas
• 10GbE cards, ports & cabling are backwards
compatible to Gig-E for staged upgrades or
future-proofing— and you can run 10GBASE-T
NICs with Cat6a cabling that’s already in place
• 30% lower power rating means lower energy
costs, lower data center maintenance fees, and
less heat to dissipate
2Install the FastFrame Adapter. Refer to
Hardware Installation
3Install drivers for your operating system. Refer
to Install Drivers
4Attach your NIC to a switch or server using an
ATTO recommended cable:
Optical (NS14, NS12, NS11)
• CBL-LCLC-R03 (3 Meter)
• CBL-LCLC-R10 (10 Meter)
10GBASE-T (NT12, NT11)
• CAT6a
on page 8.
on page 14.
Install your FastFrame NIC into a PCIe 2.0
x8 expansion slot for best performance
• Storage, cables and connectors
http://www.attotech.com/products/cable-finder/
1
FastFrame NS14 Adapter
FastFrame's comprehensive, easy-to-understand
portfolio includes single-, dual-, and quad-port
adapters with included high-quality SFP+ connectors a hidden cost with some competitor cards - and
support for direct attach copper cables. Quad-port
adapters conserve PCI slots for more flexible system
design. FastFrame™ draws up to 60% less power
than competing solutions. A lower power rating means
lower energy costs, lower data center maintenance
fees, and fewer worries about heat dissipation. In
addition to wide support for Windows and Linux server
and desktop operating systems, ATTO leads in high
performance I/O connectivity for Mac OS X
environments.
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
interconnect
• Conforms to PCI Express Base Spec 2.0
• Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 6.52 inches
• Height: 4.375 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 15.7 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket
• External LEDs for on-line and speed status for
each port
• Four pluggable optical LC SFP+ modules
included
Technical specifications
• Simultaneously supports multiple networking
and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput
for critical applications
• Supports Data Center Bridging; Priority-based
Flow Control (PFC), Enhanced Transmission
Selection (ETS) and DCB Exchange (DCBX)
protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s
• Jumbo frame support up to 9,000 bytes
• Tx/Rx IP, TCP & UDP checksum offloading
(IPv4, IPv6) capabilities, Transmission control
protocol (TCP), User datagram protocol (UDP),
Internet protocol (IP)
• Large send offloads (LSO)
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• openSUSE
• Fedora
TM
TM
13 & 14
11.2 & 11.3
5.x
6.x
2 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
FastFrame NS12 Adapter
FastFrame's comprehensive, easy-to-understand
portfolio includes single-, dual-, and quad-port
adapters with included high-quality SFP+ connectors a hidden cost with some competitor cards - and
support for direct attach copper cables. FastFrame™
draws up to 60% less power than competing solutions.
A lower power rating means lower energy costs, lower
data center maintenance fees, and fewer worries
about heat dissipation. In addition to wide support for
Windows and Linux server and desktop operating
systems, ATTO leads in high performance I/O
connectivity for Mac OS X environments.
Technical specifications
• Simultaneously supports multiple networking
and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput
for critical applications
• Supports Data Center Bridging; Priority-based
Flow Control (PFC), Enhanced Transmission
Selection (ETS) and DCB Exchange (DCBX)
protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s
• Jumbo frame support up to 9,000 bytes
• Tx/Rx IP, TCP & UDP checksum offloading
(IPv4, IPv6) capabilities, Transmission control
protocol (TCP), User datagram protocol (UDP),
Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
interconnect
• Conforms to PCI Express Base Spec 2.0
• Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 5.9 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket;
low-profile bracket included in finished goods
packaging
• External LEDs for on-line and speed status for
each port
• Two pluggable optical LC SFP+ modules
included
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• openSUSE
• Fedora
TM
TM
13 & 14
11.2 & 11.3
5.x
6.x
3
FastFrame NS11 Adapter
FastFrame's comprehensive, easy-to-understand
portfolio includes single-, dual-, and quad-port
adapters with included high-quality SFP+ connectors a hidden cost with some competitor cards - and
support for direct attach copper cables. FastFrame™
draws up to 60% less power than competing solutions.
A lower power rating means lower energy costs, lower
data center maintenance fees, and fewer worries
about heat dissipation. In addition to wide support for
Windows and Linux server and desktop operating
systems, ATTO leads in high performance I/O
connectivity for Mac OS X environments.
• 400,000 IOPs per port delivers high-throughput
for critical applications
• Supports Data Center Bridging; Priority-based
Flow Control (PFC), Enhanced Transmission
Selection (ETS) and DCB Exchange (DCBX)
protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
interconnect
• Conforms to PCI Express Base Spec 2.0
• Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 4.7 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket;
low-profile bracket included in finished goods
packaging
• External LEDs for on-line and speed status for
each port
• Pluggable optical LC SFP+ module included
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• openSUSE
• Fedora
TM
TM
13 & 14
11.2 & 11.3
5.x
6.x
Ethernet features
• Data rate per port: 10Gb/s
• Jumbo frame support up to 9,000 bytes
• Tx/Rx IP, TCP & UDP checksum offloading
(IPv4, IPv6) capabilities, Transmission control
protocol (TCP), User datagram protocol (UDP),
Internet protocol (IP)
• Large send offloads (LSO)
4 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
FastFrame NT12 Adapter
Built on industry-leading Intel® silicon for universal
usability, ATTO FastFrame NICs lead in high
performance I/O connectivity for Mac OS X
environments while offering broad support for
Windows and Linux server and workstation operating
systems. They provide reliable, inexpensive, fast
network access to block storage via iSCSI, with
lossless Ethernet (CEE) and Data Center Bridging
(DCB) for improved iSCSI quality of service. New to
the FastFrame family, ATTO FastFrame 10GBASE-T
NICs operate with existing structured shielded or
unshielded twisted pair copper cabling familiar to
network professionals. 10GbE cards, ports & cabling
are backwards compatible to Gig-E for staged
upgrades or future-proofing— and you can run
10GBASE-T NICs with Cat6a cabling that’s already in
place.
• Tx/Rx IP, TCP & UDP checksum offloading
(IPv4, IPv6) capabilities, Transmission control
protocol (TCP), User datagram protocol (UDP),
Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• x8 mechanical and x8 electrical PCI Express 2.0
interconnect
• Backward compatible with PCI Express 1.1
• Supports PCI Express Base Spec 2.0
• Supports PCI Express CEM Spec 2.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 13.6W (typical), 16.0W (max)
• 200 lf/m (minimum) airflow recommended
• RoHS compliant
Technical specifications
• Intel X540 10GBASE-T Ethernet Controller
• Simultaneously supports multiple networking
and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput
for critical applications
• Supports Data Center Bridging; Priority-based
Flow Control (PFC), Enhanced Transmission
Selection (ETS) and DCB Exchange (DCBX)
protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s, 1Gb/s, 100Mb/s
• Jumbo frame support up to 9,000 bytes
External connectivity
• Easy to install full height connection bracket;
low-profile bracket included in finished goods
packaging
• External LEDs for link speed and activity for
each port
• Compatible with CAT-7, CAT-6a, and CAT-6
Ethernet cables for 10GBASE-T connections
and CAT-5e for 1000BASE-T and 100BASE-TX
connections
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• SUSE Linux Enterprise® Server 11 SP1
• Fedora
• CentOS 5 & 6
TM
13 & 14
5.x
6.x
5
FastFrame NT11 Adapter
Built on industry-leading Intel® silicon for universal
usability, ATTO FastFrame NICs lead in high
performance I/O connectivity for Mac OS X
environments while offering broad support for
Windows and Linux server and workstation operating
systems. They provide reliable, inexpensive, fast
network access to block storage via iSCSI, with
lossless Ethernet (CEE) and Data Center Bridging
(DCB) for improved iSCSI quality of service. New to
the FastFrame family, ATTO FastFrame 10GBASE-T
NICs operate with existing structured shielded or
unshielded twisted pair copper cabling familiar to
network professionals. 10GbE cards, ports & cabling
are backwards compatible to Gig-E for staged
upgrades or future-proofing— and you can run
10GBASE-T NICs with Cat6a cabling that’s already in
place.
• Tx/Rx IP, TCP & UDP checksum offloading
(IPv4, IPv6) capabilities, Transmission control
protocol (TCP), User datagram protocol (UDP),
Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• x8 mechanical and x8 electrical PCI Express 2.0
interconnect
• Backward compatible with PCI Express 1.1
• Supports PCI Express Base Spec 2.0
• Supports PCI Express CEM Spec 2.0
Environmental & physical specifications
• Length: 5.6 inches
• Height: 2.71 inches
• Operating temperature: 0-55 ºC (32-131 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 13.6W (typical), 16.0W (max)
• 200 lf/m (minimum) airflow recommended
• RoHS compliant
Technical specifications
• Intel X540 10GBASE-T Ethernet Controller
• Simultaneously supports multiple networking
and storage protocols: TCP/IP, iSCSI
• 400,000 IOPs per port delivers high-throughput
for critical applications
• Supports Data Center Bridging; Priority-based
Flow Control (PFC), Enhanced Transmission
Selection (ETS) and DCB Exchange (DCBX)
protocol
• Up to 10Gb/s throughput per port
• High-performance x8 PCIe 2.0 bus
Ethernet features
• Data rate per port: 10Gb/s, 1Gb/s, 100Mb/s
• Jumbo frame support up to 9,000 bytes
External connectivity
• Easy to install full height connection bracket;
low-profile bracket included in finished goods
packaging
• External LEDs for link speed and activity for
each port
• Compatible with CAT-7, CAT-6a, and CAT-6
Ethernet cables for 10GBASE-T connections
and CAT-5e for 1000BASE-T and 100BASE-TX
connections
Software specifications
• Windows 8®, 7®, Vista®
• Windows Server® 2012, 2008, 2008 R2, 2003
• Mac OS® X (10.6 and up)
• Red Hat Enterprise Linux®
• Red Hat Enterprise Linux®
• SUSE Linux Enterprise® Server 10 & 11
• SUSE Linux Enterprise® Server 11 SP1
• Fedora
• CentOS 5 & 6
TM
13 & 14
5.x
6.x
6 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Install the ATTO FastFrame Adapter and attach your devices to it using the instructions below.
The assignment will be as follows:
Back up your system data before
changing or installing any hardware.
System requirements
The FastFrame NIC package contains the
following:
• FastFrame Network Interface Adapter
• ATTO Utilities CD
• Warranty and registration card
• SFP+ Modules (NS adapters only)
If any of these items are missing, contact your ATTO
authorized sales representative.
To install and use the FastFrame NIC you will
need:
1A computer with an available PCI Express
expansion slot
Install your FastFrame NIC into a PCIe 2.0
x8 expansion slot for best performance
2The complete FastFrame NIC package
MAC address
FastFrame NICs are configured with a unique MAC
address designated by the Institute of Electrical
and Electronic Engineers. This address, stored in
flash memory, allows the system to recognize the
FastFrame NIC as a unique part of your
configuration. The address is clearly marked on the
back of the adapter.
The MAC address assigned to an adapter is assigned
to the 1st port of the adapter. If the adapter has more
than one port then MAC address is incremented by
and assigned to the 2nd port, incremented by 2 and
assigned to the 3rd port and incremented by 3 and
assigned to the 4th port.
MAC address1st port of NS11, NS12 & NS14
MAC address + 12nd port of NS12 & NS14
MAC address + 23rd port of NS14
MAC address + 34th port of NS14
Installation
FastFrame NICs contain components that
are sensitive to electrostatic discharge
(ESD). ESD can cause damage to the
FastFrame host adapter. Please follow
standard methods to avoid ESD.
For bracket installation, please see the bracket
installation guide included in your NIC product
package.
1Install the latest drivers. Refer to Chapter 3 on
page 14.
2Power down the computer and unplug the
computer from all power sources.
3Open the case.
4Remove the cover bracket from the PCI
Express slot (v1.0a or later).
5Install the FastFrame NIC host adapter in any
open PCI Express expansion slot. If you have
questions about how to install an expansion
card in your system, consult your computer's
documentation.
The FastFrame adapters fit into x8 or x16
mechanical PCI Express slots.
6Repeat step 4 through 5 for each adapter you
want to install.
7Close the case on the computer and power it
up.
8 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Bracket details
Exhibit 2-1 FFRM-NS14 Bracket
Exhibit 2-3 FFRM-NS11
Full & Low Profile Bracket
Exhibit 2-2 FFRM-NS12 Full & Low Profile Bracket
9
Exhibit 2-4 FFRM-NT12 Full & Low Profile BracketExhibit 2-5 FFRM-NT11 Full & Low Profile Bracket
10 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Adapter board details
Exhibit 2-6 FFRM-NS14 board
Exhibit 2-7 FFRM-NS12
board
11
Exhibit 2-8 FFRM-NS11 board
Exhibit 2-9 FFRM-NT12 board
12 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Exhibit 2-10 FFRM-NT11 board
13
3 Install Drivers
Note
Note
Note
Before installing your FastFrame adapter, you must configure your system to recognize it by installing drivers for
your operating system.
1Download the latest install package from the
Intel support website at
If you already have one or more FastFrame
adapters installed and you are installing
additional adapter(s), you do not need to
perform any of these procedures unless you
are updating a previously installed driver.
The FastFrame NIC Installation CD, referred to in
these instructions, is the Installation CD that shipped
with your adapter.
OS X and the manuals for the FastFrame products.
It is recommended that the ATTO download page is
checked to get the latest OS X driver. You must
follow the directions below to get the installation
package for the OS X operating system.
This CD does not include drivers for Windows or
Linux operating systems. You must follow the
directions below to get the driver installation
packages for Windows and Linux operating
systems.
This CD contains the drivers for
http://www.intel.com/p/en_US/support
transfer it to the system.
2Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller.
The download files are the same and they are
appropriate for the FastFrame NIC controllers.
3Select the version of Windows on which the
driver will run. Then select either the
ProWin32.exe or the ProWinx64.exe file based
upon the Windows installation of 32-bit or 64-
bit.
4Download the file.
5Start the installation by double clicking the
downloaded follow.
6Follow the instructions to install the NIC driver.
and
Linux
Intel Website (NS14, NS12, NS11, NT12, NT11)
Windows
Intel Website (NS14, NS12, NS11, NT12, NT11)
Windows 8, 7, Vista, Server 2012 and
2008 may utilize a new User Account
Control Feature. Because of this there
may be additional confirmations that will
need to be performed to properly install
the driver. These confirmations normally
consist of a dialog where the user has to
give Windows permission to perform an
action. If you do not have the correct
privileges during this, you will be prompted
for an actual user name and password.
You may need to contact your system
administrator if you do not have this
information.
These steps assume a basic knowledge of
Linux terminal commands. You must also
have the correct kernel header files for the
appropriate kernel already installed.
1Download the latest install package from the
Intel support website at
http://www.intel.com/p/en_US/support
transfer it to the system.
2Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller.
The download files are the same and they are
appropriate for the FastFrame NIC controllers.
3Select the latest driver for Network Connections
under Linux.
4Download the file.
5There is a Read Me (txt) file that provides
instructions on building the Linux driver. Follow
those directions to install the NIC driver under
Linux.
and
14 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Mac OS X
ATTO Website (NS14, NS12, NS11, NT12, NT11)
1Go tohttp://www.attotech.com/downloads.html
2Log in. First-time visitors will be required to
complete registration.
3Under ‘Select Product’ choose Ethernet
Adapters.
4Select 10GbE Network Interface Cards.
5Download the latest Mac driver.
6Open the driver from the location in which it was
saved.
7Follow the on-screen instructions.
Installation CD (NS14, NS12, NS11, NT12, NT11)
1Power on your system and log in as the
administrator or a user with proper
administrative privileges.
2Insert the Installation CD.
3After the CD mounts, open the FastFrame
volume on the desktop.
4Open the Drivers folder.
5Open the folder corresponding to the OS X
version in use.
6Launch the installer package.
7Follow the on-screen instructions.
15
4 Updating Drivers
Your FastFrame NIC should ship with the latest flash and drivers, but these may need to be updated as new
versions become available. Visit the ATTO website, www.attotech.com, to download the latest drivers and flash
bundle.
Updating Windows drivers
1Download the latest install package from the
Intel support website at
http://www.intel.com/p/en_US/support
transfer it to the system.
2Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller.
The download files are the same and they are
appropriate for the FastFrame NIC controllers.
3Select the version of Windows on which the
driver will run. Then select either the
ProWin32.exe or the ProWinx64.exe file based
upon the Windows installation of 32-bit or 64-
bit.
4Download the file.
5Start the installation by double clicking the
downloaded follow.
6Follow the instructions to install the NIC driver.
and
Updating Linux drivers
1Download the latest install package from the
Intel support website at
http://www.intel.com/p/en_US/support
transfer it to the system.
2Select the Intel X540-T2 Ethernet Controller or
the Intel 82599 10 Gigabit Ehternet Controller.
The download files are the same and they are
appropriate for the FastFrame NIC controllers.
3Select the latest driver for Network Connections
under Linux.
4Download the file.
5There is a Read Me (txt) file that provides
instructions on building the Linux driver. Follow
those directions to install the NIC driver under
Linux.
and
Updating OS X drivers
1Go to http://www.attotech.com/downloads.html
2Log in. First-time visitors will be required to
complete registration.
3Under ‘Select Product’ choose Ethernet
Adapters.
4Select 10GbE Network Interface Cards
5Download the latest Mac driver.
6Open the driver from the location in which it was
saved.
7Follow the on-screen instructions.
16 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
5 Troubleshooting
Note
This chapter contains solutions for the most common problems you might encounter. If you need additional
assistance, please refer to the ATTO Technology website,
Technology representative.
General suggestions
www.attotech.com
, or contact an authorized ATTO
• Check each cable connection on every device.
• Verify all cables are in proper working condition.
Loose or broken cables are often the cause of
errors or problems.
• Check that connected devices are plugged into
an AC outlet and are turned on before you add
power to your computer.
Windows Server 2012, 2008, 2003; Windows 8, 7, Vista
• If working properly the NIC should appear in the
Device Manager.
• If the FastFrame NIC does not appear under the
Network Adapters:
a. Remove power from the PC.
b. Open the case.
c. Check that the FastFrame NIC adapter is
properly seated in the PCI slot.
d. Replace the case and apply power.
• If the adapter has been identified but there is an
exclamation point (!) on the listing:
a. Right click on the listing and select
Uninstall.
b. Reload the driver (see Updating Windows
drivers on page 16.
c. Reboot the system and repeat the
installation process.
If problems persist, contact your authorized ATTO
Technology representative.
Linux
1Verify the FastFrame driver is loaded with the
lsmod command. If lsmod does not show the
driver, refer to the installation instructions to
install and load the driver in Updating Windows
drivers on page 16.
2Check the system log with the command
dmesg. The FastFrame driver creates status
messages during initialization. Make sure that
all installed cards are properly detected and
initialized.
3Examine the contents of the file(s): /proc/scsi/
fastframe/x, where x is the adapter's host
number. This file contains details such as link
status, connection speed and discovered
devices.
Advanced users only. Modify the
makefile
Upon loading, the
displays detailed debugging information
which may help troubleshoot the problem.
to enable debugging information.
FastFrame driver
driver
17
Mac OS X
Note
Note
Note
The ATTO FastFrame supports Mac OS X
versions 10.6.x and later.
1Open the ATTO ConfigTool from the ATTO
Utilities CD or download it from the ATTO
website. Refer to the ATTO Utilities Installation
and Operations Manual for additional
information.
2If the adapter does not appear in the System
Profiler, make sure the card is seated properly
in the PCIe slot.
a. Shut down and remove power from the
Mac.
b. Remove the side of the case.
c. Check the PCIe slot
d. Replace the side of the case.
e. Apply power
If the Fastframe adapter is properly seated
and devices are still not accessible check the
cable to verify the link light is illuminated. If
not contact an authorized ATTO
representative.
3Verify the driver is loaded.
a. Click on the adapter name in the Device
Listing to view the Basic Info screen.
b. If the Driver Information section indicates
Unknown: driver not loaded, reinstall the
driver. Refer to Updating Hardware Flash
Drivers on page 25.
c. If reinstalling the driver does not fix the
problem, contact an authorized ATTO
representative.
4Reset the NVRAM for all channels to defaults
and reboot. If the problem persists, contact an
authorized ATTO representative.
When calling ATTO Technical Support
please have a printout of the IOreg listing,
Apple System Profiler, Serial number of the
adapter, and what driver and firmware that is
currently loaded in your Apple computer.
18 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Appendix A Glossary
Some terms used in the Network Interface industry are defined below. More information is available through the
ATTO Technology website (
(
www.snia.org
TermDefinition
ANSIAmerican National Standards Institute
BERBit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent
bitsmallest unit of data a computer can process: a single binary digit with a value of either 0 or 1
busa collection of unbroken signal lines used to transmit information from one part of a computer
bytean ordered set of 8 bits
channela point-to-point link which transports data from one point to another
CPUCentral Processing Unit: the portion of the computer that actually performs computations
CRCCyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
device drivera program that allows a microprocessor to direct the operation of a peripheral device
DMADirect Memory Access: a way to move data from a storage device directly to RAM without using
DMA bus masterallows a peripheral to control the flow of data to and from system memory by block as opposed to
full-duplexa communication protocol which allows transmission in both directions at the same time
half duplexa communication protocol which allows transmission in both directions, but only one direction at a
hosta processor, usually a CPU and memory, which communicates with devices over an interface
initiator devicea component which originates a command
LEDLight-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
LUNLogical Unit Number: an identifier for a logical unit (0-7)
MACMedia Access Controller
MAC AddressA unique address assigned to an ethernet device
multi-mode fiberan optical fiber which can carry several beams of light at once
N_porta port attached to a node used with point to point or fabric configurations
originatoran initiating device; a component which originates a command
parity checkinga method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
PCIPeripheral Component Interconnect. Allows peripherals to be connected directly to computer
point-to-pointa topology where two ports communicate
portan access point in a device: see N_port, NL_port, etc.
port addressalso port number; the address, assigned by the PCI bus, through which commands are sent to a
port numbersee port address
receiverthe ultimate destination of data transmission; a terminal device
).
system to another; taps on the lines connect devices to the bus
and transmitted data; if no error has occurred during transmission, the CRC for both received and
transmitted data should be the same
the CPU’s resources
allowing the processor to control the data by bytes (PIO or programmed I/O)
time
are used as indicator lights on all sorts of electronic devices
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error
message occurs if the sum is not correct
memory, bypassing the slower ISA and EISA busses
host adapter board
www.attotech.com
) and the Storage Area Networking Industry Association
i
TermDefinition
scatter/gathera device driver feature which allows the host adapter to modify a transfer data pointer so that a
single host adapter can access many segments of memory, minimizing interrupts and transfer
overhead
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source
SNMPSimple Network Management Protocol: a standard for monitoring network-attached devices
topologylogical layout of the parts of a computer system or network and their interconnections
transceivera transmitter/receiver module
transfer ratethe rate at which bytes or bits are transferred, as in megabytes or gigabits per second
ii ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Appendix B Accessories
The following accessories are available through ATTO Technology and authorized resellers. Contact an ATTO
Technology authorized sales representative to order.
Optical Cables
CBL-FCFI-05x5 m. cable – Duplex 50 Micron Multi-mode FC/Optical
CBL-LCSC-0033 m. 50/125 optical cable (LC to SC)
CBL-LCSC-01010 m. 50/125 optical cable (LC to SC)
A variety of Fibre Channel, SAS and SCSI products are also available from ATTO Technology. Please contact
your ATTO sales representative for product descriptions and part number information.
Fibre Channel solutions
ATTO Celerity
TM
Family of Fibre Channel Host Adapters
SCSI solutions
ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix C)
SAS/SATA Solutions
ATTO ExpressSAS family of SAS Host and RAID Adapters (see Appendix C)
Software
ATTO ConfigTool – Configuration and management software
ATTO Express Power Center – Windows & Mac OS X RAID 0 and benchmark software
iii
Appendix C ATTO Adapter Selection Guides
Contact your ATTO representative or visit the ATTO website for details on all ATTO products.
ExpressPCI SCSI host adapters
Ultra 320 SCSI
Product Features
Max. transfer rate (MB/sec.)640MB/s640MB/s640MB/s
Low Voltage Differential
Single-ended SCSI
Number of SCSI Channels (internal/external)2/20/22/2
Number of SCSI IDs supported303030
Low profile
Max Data Rate6Gb/s6Gb/s6Gb/s6Gb/s
x8 PCI Express• • • •
Number of ports16888
Port configuration external/internal0/168/00/84/4
Connector type4 mini SAS (x4)
SFF-8087
internal
2 mini SAS (x4)
SFF-8088
external
2 mini SAS (x4)
SFF-8087
internal
1 mini SAS (x4)
SFF-8088
external
1 mini SAS (x4)
SFF-8087
internal
Number of devices supported128 SAS/SATA
targets
1.5 Gb SATA support• • • •
3 Gb SATA II support• • • •
3 Gb SAS support• • • •
6 Gb SATA II support• • • •
6 Gb SAS support• • • •
Software RAID0, 40, 50, 600, 40, 50, 600, 40, 50, 600, 40, 50, 60
Integrated RAID0, 1, 4, 5, 6
JBOD, DVRAID
RAID Management Utility• • • •
Global Hot Spares• • • •
Event notificationE-mail, pop-up,
1m SATA
Advanced Data Streaming™• • • •
32-bit support• • • •
64-bit support• • • •
Windows• • • •
Linux • • • •
Mac OS X • • • •
Low profile• • • •
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10 SAS,
1m SATA
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10m SAS,
1m SATA
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10m SAS,
1m SATA
vi ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Celerity 8-Gb Adapters
Product FeaturesFC-84ENFC-82ENFC-81EN
Fibre Channel Ports421
FC protocol8-Gb8-Gb8-Gb
Maximum Transfer Rate (Full Duplex)6.4GB/s3.2GB/s1.6GB/s
Maximum Transfer Rate (Half Duplex)3.2GB/s1.6GB/s800MB/s
Bus typePCIe 2.0PCIe 2.0PCIe 2.0
Bus characteristics8 lane8 lane4 lane
Optical interfaceSFP+LCSFP+LCSFP+ LC
Maximum cable length300m@2-Gb
150m@4-Gb
50m@8-Gb
Low profile form factor
Advanced Data Streaming (ADS™) Technology
Software RAID support
Developer's kit (Target Mode & API)
Windows support
Linux driver support
Macintosh OS X driver support
VMware driver support
1 ATTO Express Power Center recommended
1
300m@2-Gb
150m@4-Gb
50m@8-Gb
300m@2-Gb
150m@4-Gb
50m@8-Gb
vii
Appendix D Standards, Compliances
The Technical Specification sheet for each FastFrame CNA lists certifications for that model. Models covered by
this page include the FastFrame FFRM-NS14, FFRM-NS12, FFRM-NS11, FFRM-NT12, FFRM-NT11
FCC standards: radio and television interference
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual,
may cause interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Canadian standards
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European standards
Declaration of Conformity
This following statement applies to all FastFrame adapter.
This device has been tested in the basic operating configuration and found to be compliant with the
following European Union standards: Application of Council Directive: 2004/108/EC Standard(s) to
which conformity is declared: EN55024:2010; EN55022:2010 CLASS B.
This Declaration will only be valid when this product is used in conjunction with other CE approved devices and
when the entire system is tested to the applicable CE standards and found to be compliant
Japanese standards
Voluntary Control Council for Interference by Information Technology Equipment (VCCI, Japan)
This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information
Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may
cause radio interference. Install and use the equipment according to the instruction manual.
viii ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Compliances
China RoHS Status Certifica te
中国 RoHS 认证概况
Table of Toxic and Hazardous Substances/Elements and their Content 有毒有害物质/成分及其含量表
ATTO FastFrame cards comply with Directive 2002/95/EC on the Restriction of the Use of
Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO
representative regarding RoHS compliant products.
The FastFrame family of adapters take the following RoHS exemptions:
7(a) - Lead in high melting temperature type solders (i.e. lead based alloys containing 85% by weight or more
lead).
7(c)-I - Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in
capacitors, (e.g. piezoelectronic devices, or in a glass or ceramic matrix compound).
7(c)-III - Lead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DC.
13(a) - Lead in white glasses used for optical applications.
15 - Lead in solders to complete a viable electrical connection between semiconductor die and carrier within
integrated circuit flip chip packages.
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials
for this part i s below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous
materi als used for this part is above the limit require me nt in SJ/T 11 36 3 -20 0 6.
ix
The Environment-Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise
marked. Certain fieldreplaceable parts may have a different EFUP (for example, battery modules) number. The Environment-Friendly Use
Per iod i s va lid on ly wh en th e produ ct is operated under the conditions defined in the product manual.
x ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Appendix E Safety, Warranty
All ATTO host adapter products have been tested to meet applicable safety standards when operated in proper
electrical and thermal environments.
Safety
Please review the specifications for your specific host adapter before installing and operating it in any computer
system to ensure compatibility.
Installation
Before installing an ATTO host adapter product into your computer system, unplug the computer from its electrical
power source and allow adequate time for electrical discharge and the internal components to cool down before
removing the computer system cover. This will decrease the risk of personal injury from electrical shock or
touching the hot surface of an electrical component.
Once an ATTO host adapter is installed in a computer system, the computer cover must be reinstalled properly
before turning the computer system back on.
Operation
ATTO host adapters require adequate cooling to function properly. If you have any questions as to the airflow
provided by your computer system, please refer to your computer system manual or contact your computer
system manufacturer.
To facilitate proper air circulation, ATTO host adapters should never be operated in a computer system without
the cover installed or with an inoperable fan as this may cause safety or thermal problems which could damage
the ATTO host adapter and void the warranty.
ATTO Technology, Inc. limited warranty
ATTO Technology, Inc. warrants to the original purchaser of this product that it is free from defects in material and
workmanship as described in the ATTO Technology website,
ATTO Technology, Inc. liability shall be limited to replacing or repairing, at its option, any defective product. There
is no charge for parts or labor should ATTO Technology, Inc. determine that this product is defective.
Products which have been subject to abuse, misuse, alteration, neglected, or have been serviced, repaired or
installed by unauthorized personnel shall not be covered under this warranty provision. Damage resulting from
incorrect connection or an inappropriate application of this product shall not be the responsibility of ATTO
Technology, Inc. Liability is limited to ATTO Technology, Inc.product(s); damage to other equipment connected to
ATTO Technology, Inc.product(s) is the customer’s responsibility.
This warranty is made in lieu of any other warranty, express or implied. ATTO Technology, Inc. disclaims any
implied warranties of merchantability or fitness for a particular purpose.
ATTO Technology, Inc. responsibility to repair or replace a defective product is the sole and exclusive remedy
provided to the customer for breech of this warranty. ATTO Technology, Inc. is not liable for any indirect, special,
incidental, or consequential damages irrespective of whether ATTO Technology, Inc. has advance notice of the
possibility of such damages.
No ATTO Technology, Inc. dealer, agent or employee is authorized to make any modification, extension or
addition to this warranty.
www.attotech.com