ATTO Technology FastFrame NQ41, FastFrame NQ42 Installation And Operation Manual

Page 1
ATTO FastFrame Network Interface Card
Installation and Operation Manual
FastFrame NQ41
40Gb Single Port PCIe 3.0 Network Interface Card
FastFrame NQ42
40Gb Dual Port PCIe 3.0 Network Interface Card
Page 2
ATTO Technology, Inc.
155 CrossPoint Parkway Amherst, New York 14068 USA
www.attotech.com
Tel (716) 691-1999 Fax (716) 691-9353
Sales support: sls@attotech.com Technical support: Please visit
techsupp@attotech.com (716) 691-1999 ext. 242
© 2015 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
9/2015
........................................ ...... ......... ....... .............. ................. ........ ,,,,,,,,,,,, ,, ,,,,,,,,,,,,,,,,,,,,,
https://www.attotech.com/support/
for hours of operation.
PRMA-0471-000
Page 3
Contents
1 ATTO FastFrame NIC Features & Overview ....................................................1
Getting started FastFrame NQ41 Adapter FastFrame NQ42 Adapter
2 Driver Installation ...............................................................................................8
3 Hardware Installation .........................................................................................10
4 Troubleshooting .................................................................................................20
General suggestions Windows Linux
Appendix A Glossary ............................................................................................i
Appendix B Accessories ......................................................................................iii
Appendix C ATTO Adapter Selection Guides ....................................................iv
Appendix D Standards, Compliances .................................................................viii
FCC standards: radio and television interference Compliances
Appendix E Safety, Warranty ...............................................................................xi
Safety ATTO Technology, Inc. limited warranty
Page 4
1 ATTO FastFrame 40Gb Ethernet Features &
Note
Overview
FastFrame 40Gb Ethernet Adapters provides high-performance, low-latency 40 Gbps Ethernet connectivity.
ATTO’s 40Gb Ethernet Adapter solutions are single­and dual-channel PCIe 3.0 x8 solutions offering near line-rate throughput via the usage of Remote Direct Memory Access (RDMA), specifically the RDMA over Converged Ethernet (RoCE) protocol. Simultaneously improving CPU utilization and throughput by allowing for direct memory transfers bypassing the CPU and TCP/IP stacks, RoCE is the key for any user of 40Gb Ethernet looking to take full advantage of 40Gb bandwidth. ATTO’s 40Gb Ethernet FastFrame cards come in both optical (with QSFP+s included) and Direct-Attached options, providing flexibility for numerous installations.
Driver support for 40Gb Ethernet includes multiple installations of both Windows and Linux.
FastFrame 40Gb NICs provide high-performance, low-latency 40 Gigabit Ethernet connectivity. Built using silicon provided by the industry’s leader in low latency Ethernet, Mellanox, ATTO FastFrame NICs provide the most performance and the lowest utilization of CPU cycles, in addition to industry­leading power efficiency. Supporting numerous protocols from standard TCP/IP to NFS RDMA to iSCSI, ATTO’s FastFrame 40Gb NICs are available in single- and dual-port configurations, with optical QSFP+ or direct attached copper support.
• Provides sufficient bandwidth for numerous streams of uncompressed 4k video, in addition to uncompressed 8k video
• Industry-leading latency allows for more usage of 40GbE pipe. NICs without RDMA support top out at about 21Gbps performance; with ATTO’s RDMA implementation, performance can reach near line-rate at 39Gbps.
• Lowest power utilization profile and CPU utilization profile on market combines to provide highest ROI (in terms of gigabytes transferred per dollar spent on power) among 40GbE NICs on the market.
Getting started
In general, to install the ATTO Network Interface Adapter, you must:
1 Ensure you have the equipment and software
you need for the installation:
• FastFrame 40Gb Ethernet Adapter
• A computer with an available expansion slot
Install your FastFrame NIC into a PCIe 3.0 x8 expansion slot for best performance
• Cables
http://www.attotech.com/products/cable-finder/
2 Install drivers for your operating system. Refer
to Driver Installation
3 Install the FastFrame Adapter. Refer to
Hardware Installation
4 Attach your NIC to a switch or server using an
ATTO recommended cables and QSFPs:
Optical (NQ41, NQ42)
• CBL_-0130-001 (1m)
• CBL_-0128-003 (3m)
• CBL_-0310-005 (5m)
• CBL_-0310-020 (20m)
• QSFP-0040-R00 40Gb/s, QSFP, MPO
850nm, up to 30m
on page 6.
on page 8.
1
Page 5
FastFrame NQ42 Adapter
ATTO’s comprehensive line of FastFrame 40-Gigabit Ethernet products includes dual port models to provide added connectivity for users in a wide variety of applications and enhancing support for additional streams of video in media and entertainment applications, and provides the high-quality and high­performance experience ATTO customers are accustomed to.
The FastFrame NQ42 QSFP+ NIC is best suited for users interested in utilizing qualified, high-quality pluggable optical QSFP+ transceivers providing connectivity distances of up to 30m. As a bonus, all ATTO FastFrame models which support optical QSFP+ transceivers come with QSFP+s, the cost of which can cost up to 1/2 the price of 40Gb NICs themselves.
• Tx/Rx IP, TCP & UDP checksum offloading (IPv4, IPv6) capabilities, Transmission control protocol (TCP), User datagram protocol (UDP), Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• PCI Express 3.0 (1.1 and 2.0 compatible) through a x8 edge connector
• PCIe Base 3.0 compliant
• 2.5, 5.0, or 8.0GT/s link rate x8
• Auto-negotiates to x8, x4, x2, x2
• Support for MSI/MSI-X mechanisms
Environmental & physical specifications
• Length: 2.71 inches
• Height: 5.6 inches
• Operating temperature: 0 to 55º C (32 to 131º F)
• Storage temperature: -40 to 70º C (-40 to 158º F)
• Relative humidity: 90%
• Power draw 7.69 W
• RoHS compliant
Technical specifications
• Simultaneously supports multiple networking and storage protocols: TCP/IP, iSCSI
• Supports Data Center Bridging; Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and DCB Exchange (DCBX) protocol
• Up to 40Gb/s throughput per port
• High-performance x8 PCIe 3.0 bus
Ethernet features
• Data rate per port: 40Gb/s, 10Gb/s
• Jumbo frame support up to 9,000 bytes
External connectivity
• Easy to install full height connection bracket
• External LEDs indicate link and activity
• Two pluggable optical QSFP+ modules included
Software specifications
• Microsoft Windows Server® 2012 R2
• Microsoft Windows® 8.1
• Suse Linux Enterprise® Server (latest versions)
• Red Hat Enterprise Linux® (latest versions)
2 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 6
FastFrame NQ41 Adapter
ATTO’s comprehensive line of FastFrame products includes single port 40GbE models suitable for a wide variety of high-performance applications, and provides the high-quality and high-performance experience ATTO customers are accustomed to.
The FastFrame NQ41 QSFP+ NIC is best suited fro users interested in utilizing qualified, high-quality pluggable optical QSFP+ transceivers providing connectivity distances of up to 30m. As a bonus, all ATTO FastFrame models which support optical QSFP+ transceivers come with QSFP+s, the cost of which can cost up to 1/2 the price of 40Gb NICs themselves.
• Tx/Rx IP, TCP & UDP checksum offloading (IPv4, IPv6) capabilities, Transmission control protocol (TCP), User datagram protocol (UDP), Internet protocol (IP)
• Large send offloads (LSO)
Host bus specifications
• PCI Express 3.0 (1.1 and 2.0 compatible) through an x8 edge connector
• PCIe Base 3.0 complaint
• 2.5, 5.0, or 8.0GT/s link rate x8
• Auto-negotiates to x8, x4, x2, x2
• Support for MIS/MSI-X mechanisms
Environmental & physical specifications
• Length: 2.12 inches
• Height: 5.6 inches
• Operating temperature: 0 to 55º C (32 to 131º F)
• Storage temperature: -40 to 70º C (-40 to 158º F)
• Relative humidity: 90%
• Power draw 6.54 W
• RoHS compliant
Technical specifications
• Simultaneously supports multiple networking and storage protocols: TCP/IP, iSCSI
• Supports Data Center Bridging; Priority-based Flow Control (PFC), Enhanced Transmission Selection (ETS) and DCB Exchange (DCBX) protocol
• Up to 40Gb/s throughput per port
• High-performance x8 PCIe 3.0 bus
Ethernet features
• Data rate per port: 40Gb/s, 10Gb/s
• Jumbo frame support up to 9,000 bytes
External connectivity
• Easy to install full height connection bracket;
• External LEDs indicate link and activity
• One pluggable optical QSFP+ modules included
Software specifications
• Microsoft Windows Server® 2012 R2
• Microsoft Windows 8.1
• Red Hat Enterprise Linux® (latest versions)
• SUSE Linux Enterprise® Server (latest versions)
3
Page 7
Selection guide: FastFrame adapters
Product Features FFRM-NQ41 FFRM-NQ42
Ports 12
Maximum Transfer Rate (Full Duplex) 8GT/S 16GT/S
Bus type PCIe 3.0 PCIe 3.0
Bus characteristics 8 lane 8 lane
Optical interface QSFP+ SR QSFP+ SR
Maximum cable length 30m 30M
Low profile form factor
Advanced Data Streaming (ADS™) Technology
Windows driver support
Linux Driver Support
Mac OS X driver support Q1 2016 Q1 2016
Cable length varies by interface and cable type.
Interface Cable type Max Distance
40Gb Passive Copper 1m 40Gb
Passive Copper
40Gb Active Fibre 5m
40Gb Active Fibre 20m
   
3m
4 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 8
2 Driver Installation
Note
Note
Note
Before installing your FastFrame adapter, you must configure your system to recognize it by installing drivers for your operating system.
9 Follow the on-screen instructions to complete
the driver installation.
If you already have one or more FastFrame adapters installed and you are installing additional adapter(s), you do not need to perform any of these procedures unless you are updating a previously installed driver.
10 Follow the on-screen instructions to complete
the driver installation.
Linux
Windows
Windows 8 and Server 2012 R2 may utilize a new User Account Control Feature. Because of this there may be additional confirmations that will need to be performed to properly install the driver. These confirmations normally consist of a dialog where the user has to give Windows permission to perform an action. If you do not have the correct privileges during this, you will be prompted for an actual user name and password. You may need to contact your system administrator if you do not have this information.
1 Power on your system and log in as the
administrator or a user with proper
administrative privileges. 2Go to https://www.attotech.com/downloads/ 3 Register or log in if previously registered.
4 Click on Ethernet Adapters in the left dialog. 5 Navigate to your HBA model/family in the right
dialog and click on it. 6 Scroll down to and click the desired driver
depending on the operating system. 7 A download window appears. Choose Save
File. 8 Double-click the downloaded file to extract and
launch the driver setup program.
These steps assume a basic knowledge of Linux terminal commands. You must also have the correct kernel header files for the appropriate kernel already installed.
1 Power on your system and log in as the
administrator or a user with proper administrative privileges.
2Go to https://www.attotech.com/downloads/ 3 Register or log in if previously registered. 4 Click on Ethernet Adapters in the left dialog. 5 Navigate to your HBA model/family in the right
dialog and click on it.
6 Scroll down to and click the desired driver
depending on the operating system.
7 A download window appears. Choose Save
File.
8 After the download has completed, open the
FastFrame volume on the desktop. 9 Open the Linux folder. 10 Open the Drivers folder. 11 Copy the .tgz file to a temporary folder. 12 Open a terminal window and change the
location of the copied tgz. 13 Extract the file using the command tar -xfz
<filename.tgz>.
14 Change to the directory created above then run
the installer script ./install.sh.
6 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 9
3 Hardware Installation
CAUTIONCAUTION
Note
CAUTIONCAUTION
Note
Install the ATTO FastFrame Adapter and attach your devices to it using the instructions below.
For example, for the NQ4Xseries, the assignment will be as follows:
Back up your system data before changing or installing any hardware.
System requirements
The FastFrame Ethernet Adapter package contains the following:
• FastFrame 40Gb Ethernet Adapter
• QSFP+ Modules
If any of these items are missing, contact your ATTO authorized sales representative.
To install and use the FastFrame Ethernet Adapter you will need:
1 A computer with an available PCI Express
expansion slot
Install your FastFrame NIC into a PCIe 3.0 x8 expansion slot for best performance
2 The complete FastFrame Ethernet Adapter
package
MAC address
FastFrame NICs are configured with a unique MAC address designated by the Institute of Electrical and Electronic Engineers. This address, stored in flash memory, allows the system to recognize the FastFrame NIC as a unique part of your configuration. The address is clearly marked on the back of the adapter.
MAC address MAC address + 1 MAC address + 2 MAC address + 3
Installation
FastFrame NICs contain components that are sensitive to electrostatic discharge (ESD). ESD can cause damage to the FastFrame host adapter. Please follow standard methods to avoid ESD.
For bracket installation, please see the bracket installation guide included in your NIC product package.
1 Install the latest drivers. Refer to Driver
Installation on page 6.
2 Power down the computer and unplug the
computer from all power sources. 3 Open the case. 4 Remove the cover bracket from the PCI
Express slot (v1.1a or later). 5 Install the FastFrame NIC host adapter in any
open PCI Express expansion slot. If you have
questions about how to install an expansion
card in your system, consult your computer's
documentation.
The MAC address assigned to an adapter is assigned to the 1st port of the adapter. If the adapter has more than one port then the MAC address is incremented by and assigned to the 2nd port.
8 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
The FastFrame adapters fit into x8 or x16 mechanical PCI Express slots.
6 Repeat step 4 through 5 for each adapter you
want to install. 7 Close the case on the computer and power it
up.
Page 10
Bracket details
Exhibit 3-1 FFRM-NQ42 Dual-Port Bracket
Exhibit 3-2 FFRM-NQ41 Single-Port Bracket
9
Page 11
Adapter Board Details
Exhibit 3-3 FFRM-NQ41 Single-Port board
Exhibit 3-4 FFRM-NQ42 Dual-Port board
10 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 12
4 Troubleshooting
Note
This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology
General suggestions
• Check each cable connection on every device.
• Verify all cables are in proper working condition. Loose or broken cables are often the cause of errors or problems.
Windows
• If working properly the NIC should appear in the Device Manager.
• If the FastFrame NIC does not appear under the Network Adapters:
a. Remove power from the PC. b. Open the case. c. Check that the FastFrame NIC adapter is
properly seated in the PCI slot.
d. Replace the case and apply power.
website, ATTO Technology representative.
• Check that connected devices are plugged into
• If the adapter has been identified but there is an
If problems persist, contact your authorized ATTO Technology representative.
www.attotech.com
an AC outlet and are turned on before you add power to your computer.
exclamation point (!) on the listing:
a. Right click on the listing and select
Uninstall.
b. Reload the driver (see Driver Installation
on page 6.)
c. Reboot the system and repeat the
installation process.
, or contact an authorized
Linux
1 Verify the FastFrame driver is loaded with the
lsmod command. If lsmod does not show the driver, refer to the installation instructions to install and load the driver in Driver Installation on page 6.
2 Check the system log with the command
dmesg. The FastFrame driver creates status messages during initialization. Make sure that all installed cards are properly detected and initialized.
Advanced users only. Modify the
makefile
Upon loading, the displays detailed debugging information which may help troubleshoot the problem.
to enable debugging information.
FastFrame driver
driver
20 ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 13
Appendix A Glossary
Some terms used in the Network Interface industry are defined below. More information is available through the ATTO Technology website (
(
www.snia.org
Term Definition
ANSI American National Standards Institute BER Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent bit smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1 bus a collection of unbroken signal lines used to transmit information from one part of a computer
byte an ordered set of 8 bits channel a point-to-point link which transports data from one point to another CPU Central Processing Unit: the portion of the computer that actually performs computations CRC Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
device driver a program that allows a microprocessor to direct the operation of a peripheral device DMA Direct Memory Access: a way to move data from a storage device directly to RAM without using
DMA bus master allows a peripheral to control the flow of data to and from system memory by block as opposed to
full-duplex a communication protocol which allows transmission in both directions at the same time half duplex a communication protocol which allows transmission in both directions, but only one direction at a
host a processor, usually a CPU and memory, which communicates with devices over an interface initiator device a component which originates a command LED Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
LUN Logical Unit Number: an identifier for a logical unit (0-7) MAC Media Access Controller MAC Address A unique address assigned to an ethernet device multi-mode fiber an optical fiber which can carry several beams of light at once N_port a port attached to a node used with point to point or fabric configurations originator an initiating device; a component which originates a command parity checking a method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
PCI Peripheral Component Interconnect. Allows peripherals to be connected directly to computer
point-to-point a topology where two ports communicate Port an access point in a device: see N_port, NL_port, etc. port address also port number; the address, assigned by the PCI bus, through which commands are sent to a
port number
).
system to another; taps on the lines connect devices to the bus
and transmitted data; if no error has occurred during transmission, the CRC for both received and transmitted data should be the same
the CPU’s resources
allowing the processor to control the data by bytes (PIO or programmed I/O)
time
are used as indicator lights on all sorts of electronic devices
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error message occurs if the sum is not correct
memory, bypassing the slower ISA and EISA busses
host adapter board see port address
www.attotech.com
) and the Storage Area Networking Industry Association
RDMA
i ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Remote Direct Memory Access
Page 14
Term Definition
Receiver the ultimate destination of data transmission; a terminal device RoCE
RDMA over Converged Ethernet
scatter/gather
a device driver feature which allows the host adapter to modify a transfer data pointer so that a single host adapter can access many segments of memory, minimizing interrupts and transfer overhead
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source SNMP Simple Network Management Protocol: a standard for monitoring network-attached devices Topology logical layout of the parts of a computer system or network and their interconnections Transceiver a transmitter/receiver module Transfer rate the rate at which bytes or bits are transferred, as in megabytes or gigabits per second
ii
Page 15
Appendix B Accessories
The following accessories are available through ATTO Technology and authorized resellers. Contact an ATTO Technology authorized sales representative to order.
A variety of Fibre Channel, SAS and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information.
Fibre Channel solutions
ATTO Celerity
TM
Family of Fibre Channel Host Adapters
SCSI solutions
ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix )
SAS/SATA Solutions
ATTO ExpressSAS family of SAS Host and RAID Adapters (see Appendix )
Software
ATTO ConfigTool – Configuration and management software ATTO Express Power Center – Windows & Mac OS X RAID 0 and benchmark software
iii ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 16
Appendix C ATTO Adapter Selection Guides
Contact your ATTO representative or visit the ATTO website for details on all ATTO products.
ExpressSAS 6 Gb Host Adapters
Product Features H6F0 GT H6F0 H60F H680 H608 H644
Max Data Rate 6Gb/s 6Gb/s 6Gb/s 6Gb/s 6Gb/s 6Gb/s x8 PCI Express Number of ports 16 16 16 8 8 8 Port configuration
external/internal Connector type 4 mini
16/0 16/0 0/16 8/0 0/8 4/4
SAS (x4)
SFF-8644
external
4 mini
SAS (x4)
SFF-8088
external
4 mini
SAS (x4)
SFF-8087
internal
2 mini
SAS (x4)
SFF-8088
external
2 mini
SAS (x4)
SFF-8087
internal
1 mini
SAS (x4)
SFF-8088
external
1 mini
SAS (x4)
SFF-8087
internal
Number of devices supported
1.5 Gb SATA support 3 Gb SATA II support 3 Gb SAS support 6 Gb SATA II support 6 Gb SAS support Software RAID 0 0 0 0 0 0 Cable distances up to 8m SAS,
Advanced Data Streaming™
32-bit support 64-bit support Windows Linux Mac OS X VMware Low profile 1/2 height 1/2 height 1/2 height
2048
end-point
devices
1m SATA
512
end-point
devices
up to 8m SAS,
1m SATA
512
end-point
devices
up to 8m SAS,
1m SATA
256
end-point
devices
up to 8m SAS,
1m SATA
256
end-point
devices
up to 8m SAS,
1m SATA
256
end-point
devices
up to 8m SAS,
1m SATA
iv
Page 17
ExpressSAS 6 Gb RAID Adapters
Product Features R60F R680 R608 R644
Max Data Rate 6Gb/s 6Gb/s 6Gb/s 6Gb/s x8 PCI Express Number of ports 16 8 8 8 Port configuration external/internal 0/16 8/0 0/8 4/4 Connector type 4 mini SAS (x4)
SFF-8087
internal
2 mini SAS (x4)
SFF-8088
external
2 mini SAS (x4)
SFF-8087
internal
1 mini SAS (x4)
SFF-8088
external
1 mini SAS (x4)
SFF-8087
internal
Number of devices supported 128 SAS/SATA
targets
1.5 Gb SATA support 3 Gb SATA II support 3 Gb SAS support 6 Gb SATA II support 6 Gb SAS support Software RAID 0, 40, 50, 60 0, 40, 50, 60 0, 40, 50, 60 0, 40, 50, 60 Integrated RAID 0, 1, 4, 5, 6
JBOD, DVRAID RAID Management Utility Global Hot Spares Event notification E-mail, pop-up,
log file SNMP Memory (ECC) 512 MB 512 MB 512 MB 512 MB Cable distances up to 10m SAS,
1m SATA Advanced Data Streaming™ 32-bit support 64-bit support Windows Linux Mac OS X Low profile
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10 SAS,
1m SATA
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10m SAS,
1m SATA
128 SAS/SATA
targets
0, 1, 4, 5, 6
JBOD, DVRAID
E-mail, pop-up,
log file
up to 10m SAS,
1m SATA
v ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 18
Celerity 8-Gb Adapters
Product Features FC-84EN FC-82EN FC-81EN
Fibre Channel Ports 4 2 1
FC protocol 8-Gb 8-Gb 8-Gb
Maximum Transfer Rate (Full Duplex) 6.4GB/s 3.2GB/s 1.6GB/s
Maximum Transfer Rate (Half Duplex) 3.2GB/s 1.6GB/s 800MB/s
Bus type PCIe 2.0 PCIe 2.0 PCIe 2.0
Bus characteristics 8 lane 8 lane 4 lane
Optical interface SFP+LC SFP+LC SFP+ LC
Maximum cable length 300m@2-Gb
150m@4-Gb
50m@8-Gb
Low profile form factor
Advanced Data Streaming (ADS™) Technology
Software RAID support
Developer's kit (Target Mode & API)
Windows support
Linux driver support
Macintosh OS X driver support
VMware driver support
1 ATTO Express Power Center recommended
1
      
300m@2-Gb 150m@4-Gb
50m@8-Gb
300m@2-Gb 150m@4-Gb
50m@8-Gb

vi
Page 19
Appendix D Standards, Compliances
The Technical Specification sheet for each FastFrame NIC lists certifications for that model. Models covered by this page include the FastFrame FFRM-NS14, FFRM-NS12, FFRM-NS11, FFRM-NT12, FFRM-NT11
FCC standards: radio and television interference
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Canadian standards
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European standards
Declaration of Conformity
This following statement applies to all FastFrame adapter. This device has been tested in the basic operating configuration and found to be compliant with the
following European Union standards: Application of Council Directive: 2004/108/EC Standard(s) to
which conformity is declared: EN55024:2010; EN55022:2010 CLASS B. This Declaration will only be valid when this product is used in conjunction with other CE approved devices and
when the entire system is tested to the applicable CE standards and found to be compliant
Japanese standards
Voluntary Control Council for Interference by Information Technology Equipment (VCCI, Japan) This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information
Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.
vii ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 20
Compliances
Chi na RoHS S tat us Ce rti fi cate
中国 RoHS 认证概况
Table of Toxic and Hazardous Substances/ El ements and thei r Content
有毒有害物 质/成分及其含量表
Part Name
(部件名称)
Toxic and Hazardous Substances and Elements
Lead ( Pb)
Merc ury (Hg)
Cadmi um
(Cd)
Hexavalent
Chro mium ( Cr6)
六价
biphenols
(PBB)
溴联苯
diphenyl ethers
(PBDE)
溴二苯醚
FFRM-NQ41
Ethernet Adapter Card
X O O O O O
FFRM-NQ42
Ethernet Adapter Card
X O O O O O
Notes 注意:
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006.
O: 表明该部件的所有同种材料中本有毒或有害物质的含量低于 SJ/T11363- 2006 标准所要求的限量。
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materi als used for this par t is above the l imit requirement in SJ/T11363-2006.
X: 表明该部件使用的同种材料中,至少有一种材料的有毒或有害物质的含量超过了 SJ/T11363-2006
准所要求的限量。
ATTO FastFrame cards comply with Directive 2011/65/EU on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO representative regarding RoHS compliant products.
The FastFrame family of adapters take the following RoHS exemptions:
7(a) - Lead in high melting temperature type solders (i.e. lead based alloys containing 85% by
weight or more lead).
7(c)-I - Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in capacitors, (e.g. piezoelectronic devices, or in a glass or ceramic matrix compound).
7(c)-III - Lead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DC.
13(a) - Lead in white glasses used for optical applications.
15 - Lead in solders to complete a viable electrical connection between semiconductor die and carrier within integrated circuit flip chip packages.
Polybrominated
Polybrominated
viii
Page 21
The Environment-Friendly Use Per iod (EFUP) for all enclosed products and their parts are per the symbol shown here, unless other wis e marked. Certain fi eldreplaceable parts may have a different EFUP (for example, battery modules) number. The Environment-Friendly Use
Per i od i s va lid only when the product is operated under the conditions defined in the product manual.
除非? 外特别的标注,此 标志为针对所涉及产品的 环 保使用期限标志. 某些可更换的零 部件可能会有一个不同的环保使用期限(例如,电池单元模 块). 环 保使用期限只适用于产 品在 产 品手册中所 规 定的条件下工作.
ix ATTO Technology Inc. FastFrame NIC Installation and Operation Manual
Page 22
Appendix E Safety, Warranty
All ATTO host adapter products have been tested to meet applicable safety standards when operated in proper electrical and thermal environments.
Safety
Please review the specifications for your specific host adapter before installing and operating it in any computer system to ensure compatibility.
Installation
Before installing an ATTO host adapter product into your computer system, unplug the computer from its electrical power source and allow adequate time for electrical discharge and the internal components to cool down before removing the computer system cover. This will decrease the risk of personal injury from electrical shock or touching the hot surface of an electrical component.
Once an ATTO host adapter is installed in a computer system, the computer cover must be reinstalled properly before turning the computer system back on.
Operation
ATTO host adapters require adequate cooling to function properly. If you have any questions as to the airflow provided by your computer system, please refer to your computer system manual or contact your computer system manufacturer.
To facilitate proper air circulation, ATTO host adapters should never be operated in a computer system without the cover installed or with an inoperable fan as this may cause safety or thermal problems which could damage the ATTO host adapter and void the warranty.
ATTO Technology, Inc. limited warranty
ATTO Technology, Inc. (“ATTO”) warrants to the original purchaser of this product (“Product”) that the Product is free from defects in material and workmanship for the term described for this specific Product on ATTO's website (
www.attotech.com
option. There is no charge for parts or labor if ATTO determines that this product is defective.
PRODUCTS WHICH HAVE BEEN SUBJECT TO ABUSE, MISUSE, ALTERATION, NEGLECT, OR THOSE PRODUCTS THAT HAVE BEEN SERVICED, REPAIRED OR INSTALLED BY UNAUTHORIZED PERSONNEL WILL NOT BE COVERED UNDER THIS WARRANTY. DAMAGE RESULTING FROM INCORRECT CONNECTION OR AN INAPPROPRIATE APPLICATION OF THIS PRODUCT SHALL NOT BE THE RESPONSIBILITY OF ATTO. LIABILITY UNDER THIS LIMITED WARRANTY IS LIMITED TO ATTO PRODUCT(S). DAMAGE TO OTHER EQUIPMENT CONNECTED TO ATTO PRODUCT(S) IS THE CUSTOMER'S RESPONSIBILITY. THIS LIMITED WARRANTY IS MADE IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. ATTO DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT IMPLIED WARRANTIES CANNOT BE EXCLUDED, SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD APPLICABLE TO THE PRODUCT. BECAUSE SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, THE ABOVE MAY NOT BE APPLICABLE. ATTO'S RESPONSIBILITY TO REPAIR OR REPLACE A DEFECTIVE PRODUCT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY.
). ATTO's liability shall be limited to replacing or repairing any defective product at ATTO's
x
Page 23
ATTO IS NOT RESPONSIBLE FOR DAMAGE TO OR LOSS OF ANY DATA, PROGRAMS OR ANY MEDIA. THE PRODUCTS ARE NOT INTENDED FOR USE IN: (I) MEDICAL DEVICES OR THE MEDICAL FIELD; OR (II) USE IN RUGGED APPLICATIONS.
ATTO IS NOT LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, IRRESPECTIVE OF WHETHER ATTO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. NO ATTO DEALER, AGENT OR EMPLOYEE IS AUTHORIZED TO MAKE ANY MODIFICATION, EXTENSION OR ADDITION TO THIS WARRANTY.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.