ATTO Technology ExpressSAS H1288 HBA, ExpressSAS H1280 HBA, ExpressSAS H1244 HBA, ExpressSAS H1248 HBA, ExpressSAS H644 HBA Installation And Operation Manual

...
ATTO ExpressSAS Host and RAID Adapter
Installation and Operation Manual
ExpressSAS H1208 HBA ExpressSAS H1280 HBA ExpressSAS H120F HBA ExpressSAS H12F0 HBA ExpressSAS H1244 HBA ExpressSAS H1248 HBA ExpressSAS H1288 HBA
ExpressSAS H644 HBA ExpressSAS H608 HBA ExpressSAS H680 HBA ExpressSAS H60F HBA
ExpressSAS R644 RAID Adapter ExpressSAS R608 RAID Adapter ExpressSAS R680 RAID Adapter
ExpressSAS R60F RAID Adapter
ATTO Technology, Inc.
155 CrossPoint Parkway Amherst, New York 14068 USA
www.attotech.com
Tel (716) 691-1999 Fax (716) 691-9353
Sales support: sls@attotech.com Technical support: Monday -- Friday, 8am-6pm EST
techsupp@attotech.com (716) 691-1999 ext. 242
© 2015 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
.. ... ..... ....... ........ .... . . ........ ...... ..... .... ..... ... ............ .......... ............ ...,,,,,,,, ,,,,,,,,,,,,,,,,
4/2015
PRMA-0389-000MD
Contents
1 ATTO Provides Storage Solutions............................................................................. 1
ExpressSAS 12Gb Host HBAs ExpressSAS 6Gb Host HBAs ExpressSAS 6Gb RAID Adapters
2 Install Drivers................................................................................................................9
Downloading drivers from the ATTO website Windows OS X (ExpressSAS H6xx and R6xx only) Linux VMware ESXi 5.x (ExpressSAS H6xx only) VMware ESX/ESXi 4.1 (ExpressSAS H6xx only) VMware ESX 3.5 (ExpressSAS H6xx only)
3 New Windows OS Installation...................................................................................12
4 New OS X Installation.................................................................................................13
5 Install Hardware......................................................................................................... 17
Installing the Adapter Installing CacheAssure (ExpressSAS R6xx only)
Non-Volatile (NV) Memory Card Installation Power Module Installation Bracket details Adapter board details
6 Adaptive Path Optimization (ExpressSAS RAID only).............................................30
7 Data Path and LED Control....................................................................................... 31
LED Control for Internal SAS Connectors
8 Troubleshooting........................................................................................................ 40
Appendix A Glossry........................................................................................................ i
Appendix B VMware Configuration & Management....................................................iii
Driver Configuration Adapter Management
Appendix C Standards and Compliances....................................................................vi
Appendix D Safety and Warranty.................................................................................vii
Safety ATTO Technology, Inc. limited warranty
1 ATTO Provides Storage Solutions
Note
Note
CAUTIONCAUTION
ATTO Technology ExpressSAS low-profile HBAs and RAID adapters provide 6Gb and 12Gb SAS/SATA connectivity for IT and digital video environments.
The ATTO ExpressSAS adapter family provides enhanced reliability and performance thanks to more than 25 years of ATTO experience.
Installation procedure
The ExpressSAS RAID adapter has a Getting Started Guide. If you have not used this guide or you are installing an ExpressSAS HBA, follow the instructions in this manual.
You will need:
• ExpressSAS adapter.
• Access to www.attotech.com drivers, user manuals and utilities.
• The optional low-profile bracket and its installation procedure.
• A computer with an available x8 or x16 PCI Express expansion slot. The ExpressSAS adapter has been optimized for x8 electrical slots. Check your computer’s documentation.
• SAS/SATA storage, cables and connectors.
Download
1
for your operating system. Refer to page 9 for driver installation.
2 Install the configuration software, the ATTO
ConfigTool, found on www.attotech.com to the ATTO Utilities Installation and Operation Manual for details.
3 Install the adapter. Refer to Install Hardware on
page 17. 4 Attach SAS/SATA storage. 5 Configure your storage and adapter, including
RAID, using the ATTO ConfigTool.
device drivers
Logging features are only available if the ATTO ConfigTool service is installed. We recommend installing the service as a minimum configuration.
Default settings are appropriate for most systems but you may change settings using the ATTO ConfigTool.
from the ATTO website
to obtain
. Refer
ExpressSAS features
• Point-to-point technology delivers full throughput
• One-click installation
• User-friendly ATTO ConfigTool provides a
• Fully Thunderbolt aware, including hot plug and
• For RAID adapters, a user-friendly GUI allows
• ADS™ technology alleviates data transfer
• DriveAssure™ is an ATTO exclusive
• CacheAssure™ provides confidence that your
• Adaptive Path Optimization-has built-in
• Driver support for Windows®, Linux®,
Mac® OS X(6Gb only), and VMware®
• Fully support EFI-HII interface (H12xx HBAs
• RoHS compliant
• 3-year standard warranty
Back up your system data before changing or installing any hardware.
to each connected storage device
simple host-based utility for effortless configuration; BIOS and EFI setup utilities provide flexibility for custom applications
daisy chain support in a PCIe expansion slot
quick and easy RAID setup
bottlenecks and moves data more efficiently while managing latency
combination of features for the ATTO RAID series adapters that performs predictive and corrective actions to allow the continued operation of marginal drives, while ensuring continued and uninterrupted access to data (6Gb RAID adapter only).
cached data will remain intact in the event of an unexpected power loss, while offering an environmentally friendly, maintenance-free solution. (6Gb RAID adapter only)
intelligence to sense when multiples paths to drives are available and direct I/O accordingly.(6Gb RAID adapter only)
ESX/ESXi Server (HBAs only)
only)
1
ExpressSAS 12Gb Host HBAs
ExpressSAS 12Gb host bus adapters combine 12Gb/s SAS speeds and x8 PCI Express 3.0 to deliver low latency in real-time environments. They support a dense and efficient connection to storage from servers and workstations in datacenter, data warehousing, VOD and other high-availability, high-performance applications. Providing SAS/SATA connectivity to up to 2,048 end devices (H1208, H1244 and H1280 support 1,024 end devices), ATTO 12Gb SAS HBAs are ideal for both IT and digital video environments that require a high level of performance.
Power Center Pro
Power Center Pro is an integrated software RAID solution that brings the performance and protection of RAID to storage devices attached to your ATTO ExpressSAS 12Gb host adapters with internal ports.
ATTO’s Power Center Pro is a RAID 0, 1, 1e and 10 solution included for use with ExpressSAS 12Gb SAS HBAs with internal connections, providing a cost­effective option that adds performance and protection to your storage architecture.
To learn more about using and configuring Power Center Pro RAID groups, refer to the ATTO Utilities software manual (
www.attotech.com
).
H1208 technical specifications
• 8 internal SFF-8643 SAS ports to PCIe 3.0 host interface
• Up to 12Gb/s per port performance
• Conforms to PCIe low profile form factor
• Length: 6.600”
• Height: 2.536”
• Operating temperature: 0-55 °C (32 °F-131 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.9A; 3.3V @ 0.1A, 11W
• Airflow: 100 lf/m minimum
H1280 technical specifications
• 8 external SFF-8644 SAS ports to PCIe 3.0 host interface
• Up to 12Gb/s per port performance
• Conforms to PCIe low profile form factor
• Length: 6.600”
• Height: 2.536”
• Operating temperature: 0-55 °C (32 °F-131 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.9A; 3.3V @ 0.1A, 11W
• Airflow: 100 lf/m minimum
2 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual
H120F technical specifications
• 16 internal SFF-8643 SAS ports to PCIe 3.0 host interface
• Up to 12Gb/s per port performance
• Conforms to PCIe low profile form factor
• Length: 6.600”
• Height: 2.536”
• Operating temperature: 0-55 °C (32 °F-131 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 1.2A; 3.3V @ 0.1A, 15W
• Airflow: 200 lf/m minimum
H1244 technical specifications
• 4 external SFF-8644, 4 internal SFF-8643 SAS ports to PCIe 3.0 host interface
• Up to 12Gb/s per port performance
• Conforms to PCIe low profile form factor
• Length: 6.600”
• Height: 2.536”
• Operating temperature: 0-55 °C (32 °F-131 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 1.2A; 3.3V @ 0.1A, 11W
• Airflow: 100 lf/m minimum
H12F0 technical specifications
• 16 external SFF-8644 SAS ports to PCIe 3.0 host interface
• Up to 12Gb/s per port performance
• Conforms to PCIe low profile form factor
• Length: 6.600”
• Height: 2.536”
• Operating temperature: 0-55 °C (32 °F-131 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 1.2A; 3.3V @ 0.1A, 15W
• Airflow: 200 lf/m minimum
H1248 technical specifications
• 4 external SFF-8644, 4 internal SFF-8643 SAS ports to PCIe 3.0 host interface
• Up to 12Gb/s per port performance
• Conforms to PCIe low profile form factor
• Length: 6.600”
• Height: 2.536”
• Operating temperature: 0-55 °C (32 °F-131 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 1.2A; 3.3V @ 0.1A, 15W
• Airflow: 200 lf/m minimum
3
H1288 technical specifications
• 8 external SFF-8644, 8 internal SFF-8643 SAS ports to PCIe 3.0 host interface
• Up to 12Gb/s per port performance
• Conforms to PCIe low profile form factor
• Length: 6.600”
• Height: 2.536”
• Operating temperature: 0-55 °C (32 °F-131 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 1.2A; 3.3V @ 0.1A, 15W
• Airflow: 200 lf/m minimum
4 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual
ExpressSAS 6Gb Host HBAs
ATTO ExpressSAS Host HBAs are engineered for the most stringent IT server and digital media workgroup environments and are compatible with multiple operating systems, applications, and drives.
Providing SAS/SATA II connectivity to up to 1,024 end devices, the ATTO SAS Host HBA is ideal for both IT and digital video environments that require a high level of performance.
H644 technical specifications
• Four internal SFF-8087, four external SFF-8088 ports
• Up to 6-Gb/sec per port performance
• Form factor conforms to PCI low-profile specification
• Length: 6.600”
• Height: 2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 5-95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.6A; 3.3V @ 0.2A, 8W
• Airflow: 100 lf/m minimum
H680 technical specifications
• Eight external SFF-8088 ports
• Up to 6-Gb/sec per port performance
• Length: 6.600”
• Height: 2.846”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 5-95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.6A; 3.3V @ 0.2A, 8W
• Airflow: 100 lf/m minimum
H608 technical specifications
• Eight internal SFF-8087 ports
• Up to 6-Gb/sec per port performance
• Form factor conforms to PCI low-profile specification
• Length: 5.600”
• Height: 2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 5-95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.6A; 3.3V @ 0.2A, 8W
• Airflow: 100 lf/m minimum
5
H60F technical specifications
• 16 internal SFF-8087 ports
• Up to 6-Gb/sec per port performance
• Form factor conforms to PCI low-profile specification
• Length: 8.638”
• Height: 2.918”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 5-95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 1.6A; 3.3V @ 0.8A, 22W
• Airflow: 100 lf/m minimum
H6F0 technical specifications
• 16 external SFF-8088 ports
• Up to 6-Gb/sec per port performance
• Length: 5.600”
• Height: 4.376”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 5-95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 1.6A; 3.3V @ 0.6A, 22W
• Airflow: 100 lf/m minimum
6 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual
ExpressSAS 6Gb RAID Adapters
ATTO ExpressSAS RAID adapters are ideal for both IT and digital video environments that require a high level of protection and performance, supporting up to 256 end devices.
RAID improves data accessibility and reliability during normal operations. A RAID group is a virtual, independent single drive with data written to physical drives according to a RAID algorithm.
DriveAssure™ lets you run longer, faster and smoother without interrupting data flow while avoiding the unnecessary cost of replacing functional drives.
The ATTO ExpressSAS RAID adapters support JBOD, DVRAID™, RAID Level 0, 1, 4, 10, 5, 6, 50, 60 and advanced features such as read caching, Hot Spares, automatic RAID group rebuilding, hot swap and Simple Network Management Protocol (SNMP).
R644 technical specifications
• Four external SFF-8088 & four internal SFF­8087 ports
• Up to 6-Gb/sec per port performance
• Form factor conforms to PCI low-profile specification
• Length: 6.600”
• Height: 2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.8A; 9.6W
• 12V @1.22A; 3.3V @ .06A, 15.05W (NVCACHE charging), 12V @1.00A;
3.3V @ .06A, 12.34W (NVCACHE charged)
• Airflow: 150 lf/m minimum
R680 technical specifications
• Eight external SFF-8088 ports
• Up to 6-Gb/sec per port performance
• Form factor conforms to PCI low-profile specification
• Length: 6.600”
• Height: 2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.8A; 9.6W
• 12V @1.22A; 3.3V @ .06A, 15.05W (NVCACHE charging), 12V @1.00A;
3.3V @ .06A, 12.34W (NVCACHE charged)
• Airflow: 150 lf/m minimum
7
R60F technical specifications
• Sixteen internal SFF-8087 ports
• Up to 6-Gb/sec per port performance
• Form factor conforms to PCI low-profile specification
• Length: 6.600”
• Height: 2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.8A; 9.6W
• 12V @1.22A; 3.3V @ .06A, 15.05W (NVCACHE charging), 12V @1.00A; 3.3V @ .06A, 12.34W (NVCACHE charged)
Airflow: 150 lf/m minimum
R608 technical specifications
• Eight internal SFF-8087 ports
• Up to 6-Gb/sec per port performance
• Form factor conforms to PCI low-profile specification
• Length: 6.600”
• Height: 2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 10-90% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5-95% non-condensing
• Power (typ): 12V @ 0.8A; 9.6W
• 12V @1.22A; 3.3V @ .06A, 15.05W (NVCACHE charging), 12V @1.00A; 3.3V @ .06A, 12.34W (NVCACHE charged)
8 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual
2 Install Drivers
ATTO ExpressSAS adapters require a current device driver and hardware flash for proper operation.
Your adapter was properly flashed before shipment. However, you must add ExpressSAS drivers to your computer before continuing with installation.
If you already have one or more ExpressSAS adapters installed and you have the latest drivers found on the ATTO website, or you followed the instructions in the Getting Started Guide, you do not need to perform of these procedures.
any
Drivers are provided on the ATTO website. http://www.attotech.com/downloads.php. Log in, if previously registered, or register to proceed to the download pages. Once downloaded, continue with the driver installation procedures (below) for your operating system.
Downloading drivers from the ATTO website
Use this procedure if you need to update drivers. The latest driver for your adapters can be found on the ATTO website.
1Go to www.attotech.com. 2 On the home page menu, put your cursor over
Downloads then click on Downloads. 3 Register or log in if previously registered. 4Select SAS/SATA HBAs and RAID adapters
from the product list. 5 Select your model. 6 From the table, find your Operating System.
7 Click on the entry for the latest driver. 8 A download window appears. Follow the
instructions for downloading the driver.
Internet Explorer users may select Run to automatically run the downloaded self­extracting executable file.
All other browser users select a download destination and run the self-extracting executable file.
9 Continue with the driver installation as
described on the following pages for your Operating System.
at
Windows
Installing from the ATTO Technology website
1 Power on your system. 2 Log on to Windows as the system
administrator. 3 Locate the ATTO driver on your system and
click unzip. The driver files are extracted and
the driver installer is launched. 4 For Windows 8, 7, Vista and Server 2012,
2008: If you have User Account Control
enabled, you are asked for permission for the
installer to continue. If you do not have
administrator privileges, you are also asked for
an administrator user name and password.
Fulfill the required fields and click Continue. 5 Click Install. 6 Follow the on-screen instructions to complete
the driver installation. 7 Continue on to Install Hardware
on page 17.
Installing from a directory containing the ExpressSAS driver
1 Power on your system. 2 Log on as the system administrator. 3 Navigate to the directory containing the
ExpressSAS driver. 4Run Setup.exe. 5 Click Install.
For Windows 8, 7, Vista and Server 2012,
2008: If you have User Account Control
enabled, you are asked for permission for the
installer to continue. If you do not have
administrator privileges, you are also asked for
an administrator user name and password.
Fulfill the required fields and click Continue. 6 Follow the on-screen instructions to complete
the installation. 7 Continue on to Install Hardware
on page 17.
9 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual
OS X (ExpressSAS H6xx and R6xx only)
Note
Note
Note
1 Power on your system. 2 Double-click the downloaded driver file to
launch the installer
Linux
Newer PCs may ship with UEFI firmware with Secure Boot enabled. With Secure Boot the operating system boot loaders, Linux kernel, and all kernel modules must be signed with a private key and authenticated with a corresponding public key.
When trying to load an unsigned ATTO driver on a secure boot system, you will see the following error: modprobe: ERROR: could
not insert '<driver-name>': Required key not available
Refer to the Linux driver read me file (readme.html) contained in the driver bundle for instructions on signing and authenticating your ATTO Linux drivers.
ExpressSAS adapters are not supported under Linux kernel 2.4.
1 Power on your system. 2 Log in as root. 3 Verify that the kernel header files, usually
included with the Linux kernel development package, are installed.
4 Locate the downloaded driver and copy the
driver file to a directory such as /usr/src
5 Open a Terminal session and change to the
directory where you stored the driver.
6 Open your File Browser and browse to
/mnt/cdrom/Linux/Drivers.
7 Click on the driver:
• for the ExpressSAS HBAs, the driver
3 Follow the on-screen instructions. 4 Continue on to Install Hardware 5 Launch
filename appears as lnx_drv_esashba#_XXX.tgz where # is the product family and XXX is the driver’s current version number.
• for ExpressSAS RAID adapters, the driver filename appears as lnx_drv_esasraid#_XXX.tgz where # is the product family and XXX is the driver’s current version number.
8 Copy the driver file to a directory such as
/usr/src. 9 Open a Terminal session. 10 Change to the directory where you stored the
driver. 11 Extract the driver source:
• for ExpressSAS HBAs: tar xfz lnx_drv_esashba#_XXX.tgz.
• for ExpressSAS RAID adapters: tar xfz lnx_drv_esasraid#_XXX.tgz.
12 The driver files are extracted to a directory
called lnx_drv_esashba_XXX or lnx_drv_esasraid_XXX.
Navigate to that directory.
13 Compile and install the driver using ./install.sh.
The driver is now installed and ready to use.
14 Add the following line to /etc/modprobe.conf
after installing the driver:
• for ExpressSAS HBAs: alias scsi_hostHBAX esashba where X is the next available HBA number.
• for ExpressSAS RAID adapters: alias scsi_hostHBAX esasraid where X is the next available HBA number.
15 Continue on to Install Hardware
on page 17.
on page 17.
VMware ESXi 5.x (ExpressSAS H6xx only)
You can add an ATTO adapter and install the driver after installing ESXi 5.
ESXi 5.0 supports H6xx
ESX 5.5 supports H12XX
10
Note
Refer to Appendix B
Note
Note
on page iii for additional information on configuring and managing ExpressSAS adapters in VMware
1 Download the Driver Bundle from the VMware
or ATTO website for your ATTO adapter. Unzip the contents of the bundle on your local workstation. Within the bundle you will find the Driver VIB file (.vib) for your ATTO adapter.
2 Use the Datastore Browser in the vSphere
Client to upload the VIB file to your ESXi host. Alternatively, you can use a program like winscp on Windows or scp on Linux to upload the file directly to your ESXi host.
3 Log in to the ESXi host on the Local Tech
Support Console (ESXi), or through an SSH client.
4 Install the VIB using the following command on
the ESXi host:
Driver Configuration
# esxcli software vib install -v <full path to VIB file>
5 Once the VIB is installed, reboot the ESXi host. Some ATTO drivers for ESXi 5.0 are provided as
Community Supported drivers. These are not certified by VMware. Please contact ATTO Technical Support for questions about these drivers.
To install an ATTO Community Supported driver on ESXi 5.0, the acceptance level must be changed with the following command:
esxcli software acceptance set --
level=CommunitySupported
Including Driver in boot image
VMware vSphere 5 includes the ability to dynamically construct boot images for your ESXi 5 servers. This allows you to include ATTO drivers as part of a boot image and install or boot ESXi 5 with that image. The end result is that your server(s) will boot and have ATTO drivers included without any additional steps. Consult the VMware vSphere 5 documentation for more information on using vSphere Image Builder.
VMware ESX/ESXi 4.1 (ExpressSAS H6xx only)
1 During ESX installation, select Yes to install
custom drivers and click Add.
Refer to Appendix B on page iii for additional information on configuring and managing ExpressSAS adapters in VMware
ESX Installation (ESX only)
During ESX 4 installation, you may choose to install additional drivers. This will allow you to install ESX onto storage that is attached to your ATTO adapter. You will need to burn the appropriate ATTO driver ISO image to CD media.
Driver Configuration
2 The installer will prompt you to insert the media
containing the ATTO device driver.
3 After you add the ATTO driver, the installer will
prompt you to reinsert the ESX installation media and continue with the installation.
4 When the installer reaches the point to choose
the location for the ESX install, you can choose local storage, or storage that is attached to your ATTO adapter.
VMware ESX 3.5 (ExpressSAS H6xx only)
Creating a Boot or Update CD.
Refer to Appendix B on page iii for additional information on configuring and managing ExpressSAS adapters in VMware
Driver Configuration
1 Download the correct driver .iso file from the
VMware Drivers & Tools Download site. 2 Write the .iso image to a CD-ROM. 3 Use the CD-ROM as a Boot CD or an Update
CD.
11 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual
3 New Windows OS Installation
When you install a new or different copy of the Windows operating system on a disk attached to an ATTO ExpressSAS adapter, you must reinstall the ATTO ExpressSAS drivers.
If you are changing the version of Windows you are using or installing a fresh copy of your current version onto your system, you must ensure Windows recognizes your ATTO ExpressSAS and uses its drivers.
You may create an installation media (disk, CD or USB flash drive) from a file from the ATTO website, then use that media to install the adapter and its driver to the new version of Windows.
Follow these procedures after you have completed installation of the ExpressSAS adapter and you have connected storage devices (refer to on page 15).
Install Hardware
Adjusting Adapter settings with the EFI Configuration Utility
Depending on your configuration, it may be necessary to adjust adapter NVRAM settings prior to performing the Windows installation. For example, you may need to modify the device wait time. The EFI configuration utility can be launched from an EFI shell. A built-in EFI shell is included with many PC platforms. If your platform does not have a built-in EFI shell, one can be obtained at
Once in the EFI shell, do the following to open the EFI Configuration Utility:
1 At the prompt, enter the drivers -b command.
Scroll through the list of installed EFI drivers and find the ATTO ExpressSAS driver. There may be more than one entry based on the number and type of adapter(s). Note the two or three digit hexadecimal driver handle on the far left of the screen.
2 At the prompt, enter drvcfg -s {handle} where
{handle} is the hexadecimal number from the previous step. This will launch the EFI Configuration Utility for the associated adapter.
3 Use the on-screen menus to configure your
adapter. Help is available at the bottom of the screen.
4 When exiting the configuration utility, if you
changed any settings, the system will restart the adapter so the new settings take effect.
http://tianocore.sourceforge.net
.
5 At the prompt, enter exit to return to the EFI
boot manager or reset to restart the system.
Power Center Pro HBA RAID Solution
Power Center Pro is an integrated software RAID solution that brings the performance and protection of RAID to storage devices attached to your ATTO ExpressSAS 12Gb host adapters.
ATTO’s Power Center Pro is a RAID 0, 1, 1e and 10 solution included for use with ExpressSAS 12Gb SAS HBAs with internal connections, providing a cost­effective option that adds performance and protection to your storage architecture.
To learn more about using and configuring Power Center Pro RAID groups, refer to the EFI section ATTO Utilities Manual on setting up RG to install the
www.attotech.com
OS (
).
Creating ExpressSAS installation media from a file
1Go to www.attotech.com.
2 Put your cursor over Downloads then click on
Driver downloads from the splash screen
menu.
3 Register or log in if previously registered.
4Select SAS/SATA Host & RAID adapters from
the product list.
5 Select your model.
6 From the table, find your Operating System.
7 Click on the entry for the latest driver.
8 A download window appears. Follow the
instructions for downloading the driver.
Internet Explorer users may select Run to
automatically run the downloaded self-
extracting executable file.
All other browser users select a download
destination and run the self-extracting
executable file.
9 Uncheck When done unzipping open
\Setup.exe.
10 Select a destination folder and click Unzip to
extract the driver files.
12
11 The expanded software package contains a
Scsiport driver in the base directory and a Storport driver in the Storport directory.
Navigate to the folder with the desired ExpressSAS driver.
Select Scsiport for Windows 2000 and XP.
Select Storport for all other versions of
Windows.
12 Run makedisk.exe.
13 Follow the instructions to complete the
installation.
14 Continue with Install the driver into a new
version of Windows 8, 7, Server 2012, 2008.
Install the driver into a new version of Windows 8, 7, Server 2012, 2008
1 Start Windows text mode setup as described by
your Windows documentation.
2Select Custom installation.
3The Where do you want to install Windows
message appears. Click Load Driver.
4 Insert the ExpressSAS installation media into
the appropriate slot.
5 Click OK.
6 Windows Setup searches for drivers matching
devices in your system. If the ExpressSAS adapter is not in the Select the driver to be installed, click Browse and locate the driver.
7 Select the ExpressSAS adapter from the list.
8 Click Next.
9The Where to you want to install Windows
window appears. Your devices should be listed.
Remove the ExpressSAS installation media.
10 Configure and select a partition for installing
Windows.
11 Click Next.
12 Continue with the remainder of the Windows
installation procedure.
13 ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual
Loading...
+ 35 hidden pages