ATTO ExpressPCI FC 3321
Fibre Channel Interface
Advanced FC features
Advanced SCSI-FCP support
Exclusive Advanced Data Streaming (ADS
Accelerated PCI bus management
Environmental & physical specifications
ATTO ExpressPCI FC 3322
Fibre Channel Interface
Advanced FC Features
Advanced SCSI-FCP Support
Exclusive Advanced Data Streaming (ADS™) Technology
Accelerated PCI Bus Management
Environmental & Physical Specifications
ATTO ExpressPCI FC 3342
Fibre Channel Interface
Advanced FC Features
Advanced SCSI-FCP Support
Exclusive Advanced Data Streaming (ADS™) Technology
Accelerated PCI Bus Management
Environmental & Physical Specifications
TM
) Technology
2 Fibre Channel is a key technology for storage ...................................... 5
Glossary
3 Hardware installation and initial configuration ...................................... 7
System requirements
Fibre Channel address
Installation
LEDs
Cabling
ExpressPCI FC 3321
ExpressPCI FC 3322
ExpressPCI FC 3342
Initial configuration
4 Installing/updating device drivers and firmware ................................... 11
Windows 2000/XP driver installation
Windows NT driver installation
Mac OS X driver installation/update
Re-flashing firmware
Linux and Sun Solaris driver installation
Appendix A Standards and compliances ..................................................i
Appendix B Fibre Channel accessories .................................................... ii
Appendix C SCSI host adapter selection guide ........................................iii
Appendix D Contact ATTO Technology, Inc. ............................................iv
1ATTO provides Fibre Channel solutions
ATTO ExpressPCI FC host adapters have been designed to ensure interoperability with Fibre Channel
devices and compatibility with a broad range of servers and workstations to meet your needs.
ATTO ExpressPCI FC 3321
The ATTO ExpressPCI FC 3321 host adapter
incorporates dual independent channels with 2Gigabit Fibre Channel performance on a single
low-profile Fibre Channel host adapter. The
ATTO ExpressPCI FC 3321 is designed to
support data-intensive applications while using
only one PCI slot, representing a cost-effective
and efficient choice for Enterprise and
Workstation applications. It supports highperformance applications, including Digital
Video/Audio, Imaging/Fixed Content and
Backup/Archiving.
Fibre Channel Interface
❖
2.125 Gigabit data transfer rates on each
channel
❖
400 MB/sec. per channel, full duplex
❖
Auto negotiation between 1-Gigabit and
2-Gigabit speeds
❖
Short-wave optical LC SFF connectors
❖
Supports all Fibre Channel topologies
Point to point
Arbitrated loop
Switched fabric (FL-port, F-port)
LED indicates link activity, on line and
fault status for each channel
❖
Flash ROM for easy field upgrades
Advanced FC features
❖
Support for SNIA HBA API
❖
LUN masking
❖
Supports target and initiator modes
Advanced SCSI-FCP support
❖
Large command FIFO
❖
Asynchronous I/O support
❖
ASPI and SCSI Manager 4.3 compatible
❖
Bootable from attached disks
❖
Support for multiple block sizes
Exclusive Advanced Data Streaming
TM
(ADS
) Technology
❖
Improved PCI system bandwidth use
❖
Optimized FC and SCSI-3 algorithms
❖
Supports SCSI-3 tagged command
queuing
❖
RISC processor for high performance
Accelerated PCI bus management
❖
PCI Bus Master DMA
❖
PCI 2.2 and PCI 99 compliant
❖
64-bit/66 MHz PCI (backward
compatible with standard 32-bit and
33MHz busses)
Environmental & physical specifications
❖
Temperature: 0-50oC
❖
Humidity: 5-90% non-condensing
❖
Low profile dimensions
Height: 2.53”
Width: 6.6”
❖
Low profile and full height brackets
available
❖
MTBF: >250,000 hours
❖
MTTR: <15 minutes
❖
Power requirements:
1.5 Amp max @ 5.0 Volts
❖
Airflow: 100 LFM (min.)
❖
PCI signal compatibility:
3.3V/5V universal
1
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
ATTO ExpressPCI FC 3322
The ATTO ExpressPCI FC 3322 host adapter
incorporates dual independent channels of 2Gigabit Fibre Channel performance on a single,
low-profile host adapter. Its low-profile design
facilitates flexibility and maximum performance
in high-density environments. It supports highperformance applications, including Digital
Video/Audio, Imaging/Fixed Content and
Backup/Archiving.
Fibre Channel Interface
❖
2.125-Gigabit data-transfer rates on each
channel
❖
400 MB/sec. per channel, full duplex
❖
Auto negotiation between 1-Gigabit and
2-Gigabit speeds
❖
Short-wave optical LC SFP connectors
❖
Supports all Fibre Channel topologies
Point to Point
Arbitrated loop
Switched fabric (FL-port, F-port)
LEDs indicate link activity, on line and
fault status for each channel
❖
Flash ROM for easy field upgrades
Exclusive Advanced Data Streaming
(ADS™) Technology
❖
Improved PCI system bandwidth use
❖
Optimized FC and SCSI-3 algorithms
❖
Supports SCSI-3 tagged command
queuing
❖
RISC processor for high performance
Accelerated PCI Bus Management
❖
PCI bus master DMA
❖
PCI 2.2 and PCI 99 compliant
❖
64-bit/133 MHz PCI-X
Environmental & Physical Specifications
❖
Temperature:0-50ºC
❖
Humidity:5-90% non-condensing
❖
Low-profile dimensions:
Height: 2.53"
Width: 6.521"
❖
MTBF:>250,000 hours
❖
MTTR:<15 minutes
❖
Airflow:100 LFM (min)
❖
Power Requirements:
2.0 Amps max @ 3.3 Volts
5.0 Amps max @ 5.0 Volts
❖
PCI Signal Compatibility:
3.3V/5V universal
Features and benefits
Advanced FC Features
❖
Support for SNIA HBA API
❖
LUN Masking
❖
Supports target and initiator modes
Advanced SCSI-FCP Support
❖
Large command FIFO
❖
Asynchronous I/O support
❖
ASPI compatible
❖
Bootable from attached disks
❖
Support for multiple block sizes
2
ATTO ExpressPCI FC 3342
The ATTO ExpressPCI FC 3342 host adapter,
with four independent 2-Gigabit FC ports and
delivering data-transfer rates up to 400
MB/second per channel, provides the ultimate
performance for the most demanding data
environments. It is ideal for connecting servers
directly to multiple storage sub-systems for
advanced, aggregated performance, while still
conserving valuable PCI expansion slots. It
supports high-performance applications,
including Digital Video/Audio, Imaging/Fixed
Content and Backup/Archiving.
Fibre Channel Interface
❖
2.125-Gigabit data-transfer rates on each
channel
❖
400 MB/sec. per channel, full duplex
❖
Auto negotiation between 1-Gigabit and
2-Gigabit speeds
❖
Short-wave optical LC SFP connectors
❖
Supports all Fibre Channel topologies
Point to Point
Arbitrated loop
Switched fabric (FL-port, F-port)
Fibre Channel is a serial communications technology designed to transfer large amounts of data among
a variety of hardware systems over long distances. It is a key technology for applications that require
shared, high bandwidth access to storage.
Fibre Channel provides a logical, point-to-point,
serial channel for the transfer of data between a
buffer at a source device and a buffer at a
destination device. It moves buffer contents from
one port to another, without regard to the format
or meaning of the data so different upper level
protocols are able to run over Fibre Channel
The Fibre Channel architecture is structured as a
hierarchical set of protocol layers. Defined within
these layers are rules for signal interfaces, serial
encoding and decoding, error control, frame
format and communications protocols.
Some terms used in the Fibre Channel industry are defined below. More information is available
through the ATTO Technology website
(www.fibrechannel.com)
(www.snia.org)
TermDefinition
ANSIAmerican National Standards Institute
arbitrateprocess of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop
arbitrated loopa loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can
auto negotiationhardware senses and automatically responds depending on configuration
BERBit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent
bitSmallest unit of data a computer can process: a single binary digit with a value of either 0 or 1
busa collection of unbroken signal lines used to transmit information from one part of a computer
Bytean ordered set of 8 bits
channela point-to-point link which transports data from one point to another
CPUCentral Processing Unit: the portion of the computer that actually performs computations
CRCCyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
destination
address
device drivera program that allows a microprocessor to direct the operation of a peripheral device
DMADirect Memory Access: a way to move data from a storage device directly to RAM without using
DMA bus masterAllows a peripheral to control the flow of data to and from system memory by block as opposed to
, and the Fibre Channel Consortium (
at the same time
communicate at one time; low-cost solution which may or may not use hubs and switches
system to another; taps on the lines connect devices to the bus
and transmitted data; if no error has occurred during transmission, the CRC for both received and
transmitted data should be the same
a value in the frame header of each frame which identifies the port in the node where the frame is
being sent
the CPU’s resources
allowing the processor to control the data by bytes (PIO or programmed I/O)
, Cern (
(www.attotech.com)
www.cern.ch)
, the Storage Area Networking Industry Association
, the Fibre Channel Industry Association
www.iol.unh.edu/consortiums, click on FC)
.
5
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
TermDefinition
fabricA Fibre Channel switch or two or more Fibre Channel switches interconnected to physically
transmit data between any two N_Ports on the switch or switches
FCFibre Channel
F_portA port in the Fibre Channel fabric where a N_port may attach
FL_portA port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop
framean indivisible unit for transfer of information in Fibre Channel
frame headerthe first field in the frame containing the address and other control information about the frame
full duplexa communication protocol which allows transmission in both directions at the same time
half duplexa communication protocol which allows transmission in both directions, but only one direction at a
time
hosta processor, usually a CPU and memory, which communicates with devices over an interface
initiator deviceA component which originates a command
L_porta port in an arbitrated loop, either a NL_port or a FL_port
LEDLight-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
are used as indicator lights on all sorts of electronic devices
LUNLogical Unit Number: an identifier for a logical unit (0-7)
multi-mode fiberan optical fiber which can carry several beams of light at once
N_porta port attached to a node used with point to point or fabric configurations
NL_ porta port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration
originatoran initiating device; a component which originates a command
parity checkingA method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error
message occurs if the sum is not correct
PCIPeripheral Component Interconnect. Allows peripherals to be connected directly to computer
memory, bypassing the slower ISA and EISA busses
point-to-pointa topology where two ports communicate
portan access point in a device: see N_port, NL_port, etc.
port addressalso port number; the address, assigned by the PCI bus, through which commands are sent to a
host adapter board
port numbersee port address
receiverthe ultimate destination of data transmission; a terminal device
scatter/gathera device driver feature which allows the host adapter to modify a transfer data pointer so that a
single host adapter can access many segments of memory, minimizing interrupts and transfer
overhead
SCSISmall Computer Systems Interface: a processor-independent standard for system-level interface
between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers,
scanners, etc.
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source
topologylogical layout of the parts of a computer system or network and their interconnections
transceivera transmitter/receiver module
transfer ratethe rate at which bytes or bits are transferred, as in megabytes or gigabits per second
Glossary
6
3Hardware installation and initial configuration
You will need a basic understanding of Fibre Channel before installing the ATTO ExpressPCI host
adapter. Please refer to Chapter 2 for a list of Fibre Channel-related web sites.
WAR N ING
back up your system data before changing or installing
any hardware.
ATTO Technology recommends that you
System requirements
The ATTO ExpressPCI host adapter package
contains the host adapter, the ATTO Express ProTools CD and a warranty and registration card. If
any of these items are missing, contact your
ATTO authorized sales representative.
To install and use the ATTO ExpressPCI Fibre
Channel adapter you will need:
❖
A computer with an available PCI or PCI-X
expansion slot.
❖
The complete ATTO ExpressPCI FC host
adapter package.
Fibre Channel address
ATTO ExpressPCI host adapters are configured
with a unique address designated by the Institute
of Electrical and Electronic Engineers. The
WorldWide Port Name (WWN) and Node name
are the two components of the address assigned to
Fibre Channel products. This address, which is
stored in the NVRAM on the ATTO ExpressPCI
host adapter, allows the system to recognize it as
a unique part of your configuration. The address
is clearly marked on the back of the board for easy
identification. Please keep a reference copy of the
number in a safe place or write in the space
provided below.
ExpressPCI FC host adapter WWNs are assigned
for each channel. The WWN listed on your host
adapter is assigned to the first channel (0).
Sequential WWNs apply for additional channels.
WWN 0:_____________________
WWN 1_____________________
WWN 2_____________________(FC 3342 only)
WWN 3:____________________ (FC 3342 only)
Installation
WARNING
components that are sensitive to electrostatic discharge
(ESD). ESD can cause damage to the ExpressPCI host
adapter. Please follow standard methods to avoid ESD.
1Power down the computer and unplug the
2Open the case.
3Install the ATTO ExpressPCI host adapter in
Exhibit 3-1 Inserting the host adapter
4Connect Fibre Channel devices by inserting
5Close the case on the computer and power
ATTO ExpressPCI host adapters contain
computer from all power sources.
any open PCI expansion slot. If you have
questions about how to install an expansion
card in your system, consult your
computer’s documentation.
Bracket Screw
32-bit 5V PCI Slots
64-bit, 3.3V
PCI Slots
Note: If you have difficulty seating the ATTO
ExpressPCI host adapter in 32-bit PCI bus
computers, check to make sure the connector can
accommodate 64-bit host adapters.FC 3342 host
adapters will only fit in 3.3V slots.
a Fibre Channel cable to the connector on
the ATTO ExpressPCI host adapter until you
hear a click.
it up.
7
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
ExpressPCI FC 3321
The ATTO ExpressPCI FC 3321 has two SFF
duplex LC optical connectors and uses a short
wave laser. A multi-mode cable must be used with
short wave lasers. For best performance you
should use 50 micron multi-mode optical cables.
Cable length should be no more than 500 meters.
ExpressPCI FC 3322
The ATTO ExpressPCI FC 3322 has two
pluggable SFP LC optical connectors and uses a
short wave laser. A multi-mode cable must be
used with short wave lasers. For best performance
you should use 50 micron multi-mode optical
cables. Cable length should be no more than 500
meters.
ExpressPCI FC 3342
The ATTO ExpressPCI FC 3342 has four
pluggable SFP LC optical connectors and uses a
short wave laser. A multi-mode cable must be
used with short wave lasers. For best performance
you should use 50 micron multi-mode optical
cables. Cable length should be no more than 500
meters.
LEDs
Dual-purpose LEDs, one per port and visible
through the bracket, indicate activity on the Fibre
Channel link. A blinking green LED shows
activity on that channel; a yellow LED shows a
fault condition.
LinkActivityFault
Off Green blinking Yellow
Cabling
Fibre Channel technology offers a variety of
cabling options including standard copper,
equalized copper and fiber optic, depending on
the requirements of your environment.
Installation and configuration
Exhibit 3-2 ExpressPCI FC 3321 bracket and board
ExpressPCI FC 3321 bracket and board
FC link activity/fault LED
Port 1, SFF
Port 0, SFF
optical connectors
FC Controller
PCI bus edge connector
8
Exhibit 3-3 ExpressPCI FC 3322 bracket and board
ExpressPCI FC 3322 bracket and board
Exhibit 3-4 Express PCI FC 3342 bracket and board
FC Controller
FC Controller
ExpressPCI FC 3342 bracket and board
9
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
FC Controller
Initial configuration
While the factory settings on your ExpressPCI
host adapter should provide excellent
performance for a wide range of applications,
some specialized applications may benefit from
modification of the adapter settings to tune the
adapter for a specific performance range. The
ExpressPCI Utilities Installation and Operation
Manual
provides detailed information on using
ATTO Technology configuration utilities.
Installation and configuration
10
4Installing/updating device drivers and firmware
ExpressPCI FC host adapters require a device driver and firmware for proper operation. Your adapter
firmware was properly flashed before shipment, but the firmware may need to be updated as new
versions become available, or if the factory-installed version becomes corrupt. Visit the ATTO website,
www.attotech.com, to download the latest drivers and firmware.
ATTO recommends using the same device driver
and firmware version. To verify the version:
Windows
Use the ATTO ExpressPCI
Configuration Tool for complete information
about the driver and firmware version or use a
combination of the adapter boot string (firmware
Windows 2000/XP driver installation
New installation
1After initial devices have been loaded, press F6.
The installer will prompt the user to Specify Additional Device by using the S option.
2When prompted for vendor’s disk, insert the
ATTO ExpressPro-Tools CD-ROM, into the drive
and press the ENTER key.
3Select ExpressPCI FC and then press the ENTER
key.
4Continue the installation of the operating
system. The Windows 2000 installation may
request the ExpressPCI driver disk again.
5Reboot the system.
Pre-existing installation
1Boot into Windows 2000/XP. The New Hardware
Wizard window will appear.
2Click Next.
3Choose the Search for a suitable driver for my
device option.
4Insert the ATTO ExpressPro-Tools CD.
5In next window, be sure the CD-ROM is selected
as the source for the driver.
version) during system boot and the Device
Manager (driver version)
Mac OS X
Use the ATTO ExpressPCI
Configuration Tool (driver and firmware version
available) or Apple System Profiler (driver
version only)
6Once the system finds the driver, click the Next
button.
7Click Yes when the system prompts to continue
installation.
8Reboot system.
Updating the Windows 2000 driver
1Right-click My Computer and select Properties.
2Select the Hardware tab and select Device
Manager.
3Right-click the ATTO ExpressPCI adapter
description, located under SCSI and RAID
controllers, and select Properties.
4Go to the Driver tab and select Update Driver.
5Select Next.
6Choose the Search for a suitable driver for my
device option.
7Choose the appropriate path to the new driver
location.
8Once the system finds the driver, click the Next
button.
9Click Yes when the system prompts to continue
installation.
10 Reboot system
Windows NT driver installation
New installation
1Begin the Windows NT installation using the
Windows NT Installation floppy diskettes.
2During the installation after initial devices have
been loaded, press F6. The installer will prompt
you to Specify Additional Devices by using the S
option.
3When prompted for vendor’s disk, insert the
ATTO ExpressPro-Tools CD-ROM into the drive
and press the ENTER key.
4Select ExpressPCI FC and then press the ENTER
key.
11
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
5Continue the installation of the operating
system. The Windows NT installation may
request the Express FC driver disk again.
Pre-existing installation
1Enter the Control Panel on the Start Menu under
Settings.
2Locate and double click on the SCSI Adapter icon
3Click on the Drivers tab and then the Add button.
4When the Install Driver screen appears, select
Have Disk.
5Place the ATTO ExpressPro-Tools CD-ROM into
the drive
6Change the path in the Copy Manufacturers files
from to the appropriate drive.
7Select ExpressPCI FC and click OK.
8When the driver is finished loading, reboot the
system.
Updating the Windows NT driver
1Click on the Start menu and select Run.
2Type in RDISK.EXE and press ENTER to create
an emergency repair disk.
3Double-click My Computer and open the Control
Panel.
4Double-click the SCSI Adapter icon.
Mac OS X driver installation/update
New or previous installation
1Download the appropriate version of the device
driver from the ATTO web site at
www.attotech.com.
2Extract the file to your desktop.
3Double click the installer icon and follow the on
screen prompts
Re-flashing firmware
To re-flash firmware in Windows or Mac OS X
using the ATTO ExpressPCI Configuration
To ol :
1Download the most recent version of the
Configuration Tool from the ATTO web site at
www.attotech.com.
2Download the proper flash bundle (these are
adapter specific) from the ATTO web site
3Extract these files to your desktop and install the
Configuration Tool on your system.
4Launch the Configuration Tool.
5In the Device window, select the adapter that
needs to be updated.
6In the Flash window, click on the Browse button to
find the flash bundle that you previously
downloaded to your desktop.
7Click Update to update your flash
8Reboot your system for the firmware changes to
take effect
9Refer to the ExpressPCI Utilities Operation and
Installation Manual for additional information on
using the Configuration Tool
5Click on the Driver tab and highlight the AT TO
ExpressFC driver.
6Click on the Remove button to remove the old
driver.
7Click on the Add button and select Have Disk.
8Insert the ATTO ExpressPro-Tools CD-ROM.
9Enter the appropriate path to the drive
10 If prompted, select a New installation of the
driver. Do not select Current installation.
11 Reboot your system.
4Reboot your system for the changes to take
effect.
5Current device driver version can be verified
using the ATTO ExpressPCI Configuration Tool.
Refer to the ExpressPCI Utilities Operation and
Installation Manual for additional information.
To re-flash firmware on a PC using the BIOS
utilities:
1Obtain the latest firmware from the ATTO web
site www.attotech.com and extract it to a floppy
disk by executing the self-extracting file.
2Reboot the PC.
3During the reboot process, an ATTO Technology
banner will announce that the host adapter was
detected. Enter Control-F when prompted to
begin the set-up utility. This must be done within
a few seconds after the banner appears, or you
will not be able to enter the utility. If this happens,
simply repeat step 3.
4In the utility, select the Upgrade Flash ROM option
and insert the disk into the drive slot.
5Follow the on-screen instructions.
6Remove the disk and reboot your system for the
firmware changes to take effect
Note: Firmware must be loaded from a floppy
because the CD-ROM drivers are not loaded
at this point in the system boot process.
Device drivers
Linux and Sun Solaris driver installation
ATTO offers Linux and Sun Solaris drivers which
are compatible with ExpressPCI host adapters. A
complete download package, including all
necessary installation instructions, is available on
the ExpressPro-Tools CD-ROM or directly from
the ATTO web site. Please refer to these
documents for installation instructions.
12
5Troubleshooting
This chapter contains solutions for the most common problems you might encounter. If you need
additional assistance, please refer to the ATTO Technology web site (www.attotech.com) or contact an
ATTO Technology authorized representative.
General suggestions
❖
Check each cable connection on every
device. Verify all cables are in proper
working condition. Loose or broken cables
are often the cause of errors or problems.
❖
Check that your Fibre Channel devices are
plugged into an AC outlet and are turned
on before you add power to your computer.
❖
If using an MIA, check to see it is operating
properly.
If the devices connected to the ATTO
ExpressPCI host adapter are not accessible:
1Right-click My Computer and select
Properties.
2Select the Hardware tab and select Device
Manager.
3If the ATTO ExpressPCI host adapter does
not appear under the SCSI and RAID
controllers, shut down and make sure the
ATTO ExpressPCI host adapter is properly
seated in the PCI slot (remove power from
the PC, remove its case, check the PCI slot,
replace the case, apply power).
4Reload the driver.
5If the adapter has been identified but there is
an exclamation point (!) on the listing, right
click on the listing and select Uninstall.
Reboot system and repeat the installation
process. If problems persist, contact your
authorized ATTO Technology
representative.
❖
If the card has been recently re-flashed with
new firmware, the new Windows driver
must be installed. Follow the procedure in
Chapter 4.
❖
All of the external devices connected to the
host adapter should be identified. If they do
not appear in the
Device Manager,
the
external devices or connection may not be
working properly.
❖
For Intel-based PCs, check the computer
CMOS setup and verify that the PCI slots
are configured correctly. Procedures vary
greatly: refer to the manual supplied with
your system or call the computer supplier
for configuration assistance. Windows
2000 is a Plug-n-Play OS: be sure your
computer’s BIOS is set accordingly.
❖
If these do not solve the problem, re-flash
the host adapter and re-install the Windows
2000 driver.
Windows NT
❖
If using an Intel-based PC, Fibre Channel
drives should be booted up before the host
computer. If the PC is powered up before
the drives, the drives may not be visible to
Windows NT.
If the devices connected to ATTO ExpressPCI
host adapter are not accessible:
1Open the SCSI Adapters utility in the Control
Panel under Settings.
2Verify the ATTO ExpressPCI host adapter
64-bit PCI Fibre Channel host adapter
appears under the Devices List.
3If it does not appear in the Device List, verify
that the adapter is seated properly in the PCI
slot (remove power from the PC, remove its
case, check the PCI slot, replace the case,
apply power).
4If it has been identified, click on the Drivers
Tab to see if the ATTO ExpressPCI host
adapter driver has been started. It will say
Started in the right hand column of the
window. If the ATTO ExpressPCI host
adapter driver appears but is not started,
check on the device status. In the Control
Panel click on Devices and scroll down to
expresfc. Click Startup button. Startup type
should be Boot. Click on Hardware profiles,
status should be Enabled.
13
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
5If ExpressPCI FC does not appear in the
Device List, try reloading the driver software
as described in Chapter 4 of this manual.
6If it is started, go back to the Devices tab of
the SCSI adapters utility window and double
click on the ATTO ExpressPCI host adapter
description, and then on the bus it is
assigned to. All of the external devices
connected in the loop should be identified.
If they do not appear in the Device List, the
external devices or connection are not
working properly.
❖
If the card has been recently re-flashed with
new firmware, the new NT driver must be
installed.
❖
For Intel-based PCs, check the computer
CMOS setup and verify that the PCI slots
are configured correctly. Procedures vary
greatly: refer to the manual supplied with
your system or call the computer supplier
for configuration assistance.
❖
If these suggestions do not solve the
problem, re-flash the host adapter and reinstall the Windows NT driver.
Troubleshooting
14
Appendix AStandards and compliances
The equipment described in this manual generates and uses radio frequency energy. The Technical
Specification sheet for a particular ATTO ExpressPCI host bus adapter list certifications for that model.
FCC standards: radio and television interference
WAR N ING
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
❖
Reorient or relocate the receiving antenna
❖
Increase the separation between the equipment and receiver
❖
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
❖
Consult the dealer or an experienced radio/TV technician for help
Canadian standards
This Class B digital apparatus complies with Canadian ICES-003.
This equipment has been tested and found to comply with the limits for a
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European standards
Declaration of Conformity
This following statement applies to the ATTO Express PCI host bus adapter.
This device has been tested in the basic operating configuration and found to be compliant
with the following European Union standards:
Application of Council Directive: 89/336/EEC
Standard(s) to which conformity is declared: EN55024:1998
This Declaration will only be valid when this product is used in conjunction with other CE approved
devices and when the entire system is tested to the applicable CE standards and found to be compliant.
Usage restrictions
The use of optical instruments with this product will increase eye hazard.
The multimode transceiver is a Class 1 laser product complying with IEC 825-1 and FDA-21 CFR
1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum
ratings. The laser is non-OFC compliant as it is a Class 1 device.
The optical ports of the modules must be terminated with an optical connector or with a dust plug.
CAUTION
“manufacturing” and will require, under law, recertification of the modified product with the U.S. Food and Drug
Administration (ref. 21 CFR 1040.10(i)).
Failure to adhere to the above restrictions could result in a modification that is considered an act of
i
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
Appendix BFibre Channel accessories
The following Fibre Channel accessories are available through ATTO Technology and authorized
resellers. Contact an ATTO Technology authorized sales representative to order.
CBL-FCFI-05x5 m. cable– Duplex 50 Micron Multi-mode FC/Optical
CBL-LCSC-0033 m. 50/125 optical cable (LC to SC)
CBL-LCSC-01010 m. 50/125 optical cable (LC to SC)
MIA
ADAP-MIAS-BLKMedia Interface Adapter (MIA) Short Wave
A variety of Fibre Channel and SCSI products are also available from ATTO Technology. Please contact
your ATTO sales representative for product descriptions and part number information.
ATTO Accelware SAN (Storage Area Network) volume management software
ATTO ExpressRAID Creates RAID groups across storage in networks
ATTO ExpressPro-Tools Configuration and management software
ATTO ExpressStripe for OSX MacOS X RAID and benchmark software
ii
Appendix CSCSI host adapter selection guide
ATTO Technology offers a number of SCSI and Fibre Channel solutions for storage. The following chart
compares the features of ExpressPCI SCSI host adapters.
Supported platforms: Sun Solaris; Linux; Windows XP/2000/NT, 95/98, and Macintosh OS and OS X.
Complete RAID packages are also available and include an ExpressPCI SCSI host adapter, ExpressRAID
software and appropriate cable(s). Add "-KIT" suffix to host adapter product code (i.e. EPCI-UL3D-KIT)
Specific features
Single ChannelExpressPCI Ultra 320ExpressPCI Ultra 3ExpressPCI Ultra
Wide
Max. transfer rate320 MB/sec160 MB/sec.40 MB/sec.
LVD
HVD
64-bit
32-bit
33/66 MHZ
133 MHZ
Bus ID support303015
Part numberEPCI-UL4SEPCI-UL3SEPCI-PSC
Dual Channel--- 2
independent channels
Max. transfer rate640 MB/sec320 MB/sec.
LVD
64-bit
32-bit
33/66 MHZ
ExpressPCI Ultra 320Express PCI Ultra 3
133 MHZ
Bus ID support3030
Part numberEPCI-UL4DEPCI-UL3D
iii
ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual
Appendix DContact ATTO Technology, Inc.
Customer service, sales information and technical support are available by phone Monday through Friday,
Eastern Standard Time 8:00 a.m. to 8:00 p.m., or by e-mail and web site 24-hours a day.
ATTO Technology, Inc.
155 CrossPoint Parkway
Amherst, New York 14068
(716) 691-1999 • voice
(716) 691-9353 • fax
http://www.attotech.com
ATTO Technology can also be reached via e-mail at the following addresses: