ATTO Technology FC-41EN, FC-41EL, adapter, FC-42EN, FC-44ES Installation And Operation Manual

...
Installation and Operation Manual
Celerity FC host adapters
Celerity FC-41EN
4-Gb FC single channel host adapter
Celerity FC-42EN
4-Gb FC dual channel host adapter
Celerity FC-44ES
4-Gb FC quad channel host adapter
Celerity FC-42ES
4-Gb FC dual channel host adapter
Celerity FC-41ES
4-Gb FC single channel host adapter
Celerity FC-42XS
4-Gb FC dual channel host adapter
4-Gb FC single channel host adapter
2-Gb FC single channel host adapter
© 2006 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
12/2006 Document Control Number: PRMA-0344-000
Celerity FC-41XS
Celerity FC-21PS
Celerity FC-24XL
Contents
1 ATTO provides Fibre Channel solutions ..........................................1
Celerity FC-41EN Adapter Celerity FC-42EN Adapter Celerity FC-44ES Adapter Celerity FC-42ES Adapter Celerity FC-41ES Adapter Celerity FC-42XS Adapter Celerity FC-41XS Adapter Celerity FC-21PS Adapter Celerity FC-24XL Adapter Celerity Selection Guide
2 Fibre Channel is a key technology for storage ................................11
Glossary
3 Hardware installation ..........................................................................13
Bracket details Adapter board details
4 Installing and updating drivers .........................................................23
Specialized configurations Windows 2000/XP/Server 2003 Mac OS X driver installation, update Linux driver installation, update
5 Updating hardware flash ....................................................................26
6 Troubleshooting ..................................................................................27
Mac OS X Windows 2000/XP/Server 2003 Linux
Appendix A Standards and compliances ............................................i
FCC standards: radio and television interference Canadian standards European standards Usage restrictions The following applies to the Celerity FC-42XS host adapter only
Appendix B Accessories .......................................................................iii
Appendix C SCSI adapter selection guide ..........................................iv
Appendix D Contact ATTO Technology, Inc. ......................................v
ATTO Technology Inc.Celerity FC Storage Adapters Installation and Operation Manual
1 ATTO provides Fibre Channel solutions
The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching, backup and data management. Specifically designed to enhance the functionality of third party fabric hardware and software, Celerity FC products are the industry-leading platform for storage connectivity.
Celerity FC-41EN Adapter
The Celerity FC-41EN is a single-channel host adapter. With 4-Gb FC speeds of up to 800 MB/sec., the FC-41EN supports the most demanding application requirements.
The FC-41EN takes advantage of the latest in host interconnect technology, PCI Express, a serial, high­speed connection that supports aggregate throughout up to 2 GB/sec.full-duplex. The FC-41EN is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC family products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb FC infrastructures, protecting existing technology investments.
Hardware specifications
• 1 Fibre Channel port
• 4-Gigabit data transfer rate
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 4
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation between 4­Gb, 2-Gb and 1-Gb Fibre Channel
• Supports initiator and target modes
• Supports Windows® FDMI and WMI
• Supports exclusive ATTO Advanced Data Streaming (ADS™) technology
Host bus specifications
• x4 mechanical and x4 electrical PCI Express interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
Environmental & physical specifications
• Conforms to PCIe low profile form factor specifications
• Operating temperature: 0 to 45º C (32-113º F)
• Storage temperature: -40 to 70ºC (-40 to 158º F)
• Relative humidity: 10 to 90% non-condensing
• 100 lf/m (minimum) airflow recommended
• Conforms to PCI Express low-profile form-factor specification
• 12V @ 0.5A (max)
• Length: 5.600 inches
• Height: 2.712 inches
External connectivity
• Easy-to-install full and low-profile connection plates
• External LEDs for on-line and speed status
• A pluggable optical LC SFP transceiver included
Software specifications
• Windows XP, 2000, and Server 2003
• Mac® OS X (10.4.x or later)
• Red Hat Linux (2.4 and 2.6 kernels)
• SUSE Linux (2.6 kernel)
1 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-42EN Adapter
The Celerity FC-42EN is a dual-channel host adapter, providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/sec.full-duplex per channel, the FC-42EN supports the most demanding application requirements.
The FC-42EN takes advantage of the latest in host interconnect technology, PCI Express, a serial, high­speed connection that supports aggregate throughout up to 2 GB/sec. The FC-42EN is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC family products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb FC infrastructures, protecting existing technology investments.
Hardware specifications
• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 4
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation between 4­Gb, 2-Gb and 1-Gb Fibre Channel
• Supports initiator and target modes
• Supports Windows FDMI and WMI
• Supports exclusive ATTO Advanced Data Streaming (ADS) technology
Host bus specifications
• x4 mechanical and x4 electrical PCI Express interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
Environmental & physical specifications
• Operating temperature: 0-45º C (32-113º F)
• Storage temperature: -40 to 70ºC ( -40 to 158º F)
• Relative humidity: 10 to 90% non-condensing
• 100 lf/m (minimum) airflow recommended
• Conforms to PCI Express low-profile form-factor specification
• 12V @ 0.5A (max)
• Length: 5.600 inches
• Height: 2.712 inches
External connectivity
• Easy-to-install full and low-profile connection plates
• External LEDs for on-line and speed status for each channel
• 2 pluggable optical LC SFP transceivers included
Software specifications
• Windows XP, 2000, and Server 2003
• Mac OS X (10.4.x or later)
• Red Hat Linux (2.4 and 2.6 kernels)
• SUSE Linux (2.6 kernel)
2
Celerity FC-44ES Adapter
The Celerity FC-44ES uses PCI Express Interconnect and 4-Gigabit Fibre Channel to provide 4-Gb FC speeds of up to 800 MB/sec. per channel. The FC­44ES supports high-definition video, rich content databases and other high bandwidth environments.
The FC-44ES uses PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec. (x8 PCIe) full-duplex. With software compatible with existing PCI and PCI-X products, the FC-44ES uses the same device drivers as other Celerity FC family products, simplifying installation and support.
Hardware specifications
• 4 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Supports exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI
Host bus specifications
• x8 mechanical and x8 electrical PCI Express Interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI Express to PCI/PCI-X Bridge spec 1.0
Environmental & physical specifications
• Conforms to PCI standard height, half length form-factor specifications
• Length: 6.525 inches
• Height: 3.81 inches
• Operating temperature: 0-45ºC (32-113ºF)
• Storage temperature: -40 to 70ºC (-40 to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 12V@ 2.1A (max.)
• 3.3V @ 3.0A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for each channel
• 4 pluggable optical LC SFP transceivers included
Software specifications
• Windows XP, 2000 and Server 2003
• Mac OS X (10.4.x or later)
• Red Hat Linux
• SUSE Linux (2.6 kernel)
(2.4 and 2.6 kernel)
Celerity FC-42ES Adapter
The Celerity FC-42ES is a dual-channel host adapter providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-42ES supports the most demanding application requirements.
Additionally the FC-42ES takes advantage of the latest in host interconnect technology, PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec. (x8 PCIe) full-duplex. The
3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
FC-42ES is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC family products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb Fibre Channel infrastructure, protecting existing technology.
Hardware specifications
• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-AL, FC-AL2, FC-FCP, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Supports exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI
Host bus specifications
• x8 mechanical and x8 electrical PCI Express Interconnect (non RoHS compliant); x4 mechanical and x4 electrical PCI Express interconnect (RoHS compliant)
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI Express to PCI/PCI-X Bridge spec 1.0
Environmental & physical specifications
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 100 lf/m (minimum) airflow recommended
• Non RoHS
• 12V@ .035A (max.); 3.3V @ 1.42A (max.)
• Conforms to PCI standard height, half length form-factor specifications
• Length: 6.525 inches
• Height: 3.81 inches
• RoHS
• Conforms to PCI half height, half length form-factor specifications
• 12V@ 04A (max.); 3.3V @ 1.5A (max.)
• Length: 5.6 inches
• Height: 2.712 inches
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for each channel
• 2 pluggable optical LC SFP transceivers included
Software specifications
• Windows XP, 2000 and Server 2003
• Mac OS X (10.4.x or later)
• Red Hat Linux
• SUSE Linux (2.6 kernel)
(2.4 and 2.6 kernel)
4
Celerity FC-41ES Adapter
The Celerity FC-41ES is a single-channel host adapter providing support for the most demanding application requirements. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-41ES is a cost effective connectivity solution for environments requiring maximum throughput.
The FC-41ES also takes advantage of the latest in host interconnect technology: PCI Express, a serial, high­speed connection that supports aggregate throughput up to 2 GB/sec. (x4 PCIe) full-duplex. The FC-41ES is software compatible with existing PCI and PCI-X products using the same device drivers as other Celerity FC products, simplifying user installation and support. It is backward compatible with existing 2-Gb and 1-Gb Fibre Channel infrastructure, protecting existing technology investments.
Hardware specifications
• 1 Fibre Channel port
• 4-Gigabit FC data transfer rates
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Features exclusive Advanced Data Streaming (ADS) Technology
FDMI and WMI
Host bus specifications
• x4 mechanical and x4 electrical PCI Express interconnect
• Supports PCI Express Base Spec 1.0a and CEM Spec 1.0a
• Supports PCI Express to PCI/PCI-X bridge spec
1.0
Environmental & physical specifications
• Conforms to PCIe low profile form factor specifications
• Length: 5.600 inches
• Height: 2.712 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 100 lf/m (minimum) airflow recommended
• Power: 12V@ 0.4A max; 3.3V@1.0A max.
External connectivity
• Easy-to-install full height connection bracket
• External LEDs for on-line and speed status
• Pluggable optical LC SFP transceiver included
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X (10.4.x or later)
5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-42XS Adapter
The dual-channel Celerity FC-42XS host adapter provides the highest available throughput for Fibre Channel applications while protecting technology investments via backward compatibility with existing infrastructure.
With speeds of up to 800 MB/sec. per channel, the FC­42XS is capable of supporting the most intensive data applications.
To ensure a smooth transition path, the FC-42XS leverages the existing Celerity FC software hardware architecture, allowing ATTO to deliver industry­leading quality and stable software architecture.
Hardware specifications
• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
• Includes exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI
PCI bus specifications
• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only
Environmental & physical specifications
• Conforms to PCI low profile form factor standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 3.3V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for each channel
• 2 optical LC SFP transceivers included
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X
6
Celerity FC-41XS Adapter
The single-channel Celerity FC-41XS provides speeds of up to 800 MB/sec. using full 4-Gigabit Fibre Channel performance while being fully backward­compatible with existing 2-GB and 1-Gb Fibre Channel infrastructure, protecting existing technology investments. It is capable of supporting the most data­intense applications.
Hardware specifications
• 1 Fibre Channel port
• 4-Gigabit data transfer rates
• 800 MB/sec. maximum full-duplex throughput
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb, 2­Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows WMI
• Includes exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and
PCI bus specifications
• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only
Environmental & physical specifications
• Conforms to PCI low profile form factor standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 3.3V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status
• Optical LC SFP transceiver included
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X
7 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-21PS Adapter
The Celerity FC-21PS Fibre Channel host adapter provides a single 2-Gb Fibre Channel connection from host devices to the Storage Area Network (SAN) fabric.
The FC-21PS supports the leading operating systems, providing a single solution for all connectivity needs. As with all Celerity FC products, the FC-21PS is designed for high-quality data transmission, ensuring that critical information is delivered correctly the first time to reduce fabric traffic and improve overall fabric efficiency.
Hardware specifications
• 1 Fibre Channel port
• 400 MB/sec. throughput full-duplex
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• Flash ROM for easy field upgrades
• Simultaneous multi-protocol support
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA, IETF-IPFC
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand, automatic negotiation between 2­Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows
FDMI and WMI
• Includes exclusive ATTO Advanced Data Streaming (ADS) Technology
PCI bus specifications
• 64-bit/32-bit, 66/33 MHz PCI compatible
• PCI 2.3 compliant
• 3.3V and 5V PCI signaling with universal connector
Environmental & physical specifications
• Conforms to PCI low profile form factor standards
• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• 5V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install full height connection plate
• Integrated optical LC SFF fixed transceiver
• External LEDs for on-line and speed status
Software specifications
• Windows XP, 2000, Server 2003
8
Celerity FC-24XL Adapter
The Celerity FC-24XL is a Fibre Channel advanced host adapter with four independent channels of 2-Gb connectivity and advanced functions featuring embedded processing and buffering capabilities to enable data stream manipulation, direct port-to-port transfers, off load processing, video handling and a myriad of other capabilities. The Integrated Off load & Processing Center (IOPC) uses an Intel XScale® processor core and an internal 133 MHz PCI-X data bus for top performance and low latency. IOPC simplifies and augments SAN fabric management, including:
• Port-to-port data streaming
• Hardware RAID
• Backup offload
• Metadata insertion
• Data protection
• Video handling
Hardware specifications
• 4 independent data channels, each supporting 2-Gb Fibre Channel performance
• 2.125-Gigabit data transfer rates per channel
• 400 MB/sec. maximum full-duplex throughput per channel
• Supports all FC topologies: direct fabric, arbitrated loop and point-to-point
• Flash ROM for easy field upgrades
• Simultaneous multi-protocol support
IOPC specifications
• Developer’s kit for OEMs
• Intel IOP80331 XScale processor core
• Supports up to 512 MB DDR 333 MHz SDRAM
• Internal 133 MHz PCI-X bus
• EDC error correction hardware capable of end­to-end data integrity
• ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA, IETF-IPFC
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand, automatic negotiation between 2­Gb and 1-Gb Fibre Channel
• Supports target and Initiator modes
• Supports Windows
• Includes exclusive ATTO Advanced Data Streaming (ADS) Technology
FDMI and WMI
PCI Bus specifications
• 64-bit, 133 MHz PCI-X
• 64/32-bit, 100/66/33 MHz PCI compatible
• PCI-X 1.0a compliant
• PCI 2.3 compliant
• 3.3V PCI signaling only
Environmental & physical specifications
• Conforms to PCI full form factor standards
• Length: 6.600 inches
• Height: 4.200 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to 158ºF)
• Relative humidity: 5 to 95% non-condensing
• +3.3 V@4.0A (max.)
• 100 lf/m (minimum) airflow recommended
External connectivity
• Easy-to-install connection plate
• Up to four shortwave optical LC SFP pluggable transceivers
• 2 optical LC SFP transceivers included
• External LEDs to show on-line and speed status for each channel
Software specifications
• Windows XP, 2000, Server 2003
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)
• Mac OS X
9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity Selection Guide
Product Features
Fibre Channel Ports FC protocol Maximum Transfer Rate (half
duplex)
Maximum Transfer Rate (full­duplex)
Bus Type
Bus Characteristics
3
Optical Interface
Maximum Cable Length
Low Profile form factor
ATTO Advanced Data
Celerity
FC-44ES
421211
4-Gb 4-Gb 4-Gb 4-Gb 4-Gb 2-Gb
1.6 GB/sec 800 MB/sec 400 MB/sec 800 MB/sec 400 MB/sec 200 MB/sec
2 GB/sec
PCIe PCIe PCIe PCI-X PCI-X PCI-X
8 lane 4 lane 4 lane
SFP LC SFP LC SFP LC SFP LC SFP LC SFF LC
300m@2-Gb 150m@4-Gb
Celerity
FC-42ES
FC-42EN
1 GB/sec
(ES)
1.6 GB/sec (EN)
300m@2-Gb 150m@4-Gb
• • • • •
• • • • • •
Celerity FC-41ES FC-41EN
800 MB/sec 1 GB/sec
300m@2-Gb 150m@4-Gb
Celerity
FC-42XS
64-bit
133 MHz
300m@2-Gb 150m@4-Gb
Celerity
FC-41XS
1
800 MB/sec 1 GB/sec
64-bit
2
133 MHz
300m@2-Gb 150m@4-Gb
2
Streaming (ADS) Technology
Software RAID support
Developer's Kit (Target Mode
3
• • • • • •
• • • • • •
& API)
Windows support
Linux (Red Hat, SUSE)
• • • • • •
• • • • • •
driver
Macintosh OS X driver
Novell Netware support
Solaris support
Free BSD
RoHS compliant
1 Performance ceiling is constrained by 133 MHz PCI-X bus transfer speed 2 Backward compatible to 32-bit and 33 MHz PCI; FC-21PS is 3.3V/5V Universal 3 ATTO ExpressStripe for OS X available; Express Power Center and other software RAID supported for Windows
• • • • • •
• • • • •
• • • • •
• • • • •
• • • • •
Celerity
FC-21PS
64-bit
133 MHz
500m@1-Gb 300m@2-Gb
2
10
2 Fibre Channel is a key technology for storage
Fibre Channel is a serial communications technology designed to transfer large amounts of data among a variety of hardware systems over long distances. It is a key technology for applications that require shared, high bandwidth access to storage.
Fibre Channel provides a logical, point-to-point, serial channel for the transfer of data between a buffer at a source device and a buffer at a destination device. It moves buffer contents from one port to another, without regard to the format or meaning of the data so different upper level
protocols are able to run over Fibre Channel hardware.
The Fibre Channel architecture is structured as a hierarchical set of protocol layers. Defined within these layers are rules for signal interfaces, serial encoding and decoding, error control, frame format and communications protocols.
Glossary
Some terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology website
(
www.fibrechannel.com
(
www.snia.org
)
, and the Fibre Channel Consortium (
Term Definition
ANSI American National Standards Institute
arbitrate process of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop
arbitrated loop a loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can
auto negotiation hardware senses and automatically responds depending on configuration
BER Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent
bit smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1
bus a collection of unbroken signal lines used to transmit information from one part of a computer
byte an ordered set of 8 bits
channel a point-to-point link which transports data from one point to another
CPU Central Processing Unit: the portion of the computer that actually performs computations
CRC Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
destination address
device driver a program that allows a microprocessor to direct the operation of a peripheral device
DMA Direct Memory Access: a way to move data from a storage device directly to RAM without using
DMA bus master allows a peripheral to control the flow of data to and from system memory by block as opposed to
)
, Cern (
(
www.attotech.com
www.cern.ch
at the same time
communicate at one time; low-cost solution which may or may not use hubs and switches
system to another; taps on the lines connect devices to the bus
and transmitted data; if no error has occurred during transmission, the CRC for both received and transmitted data should be the same
a value in the frame header of each frame which identifies the port in the node where the frame is being sent
the CPU’s resources
allowing the processor to control the data by bytes (PIO or programmed I/O)
)
, the Fibre Channel Industry Association
)
, the Storage Area Networking Industry Association
www.iol.unh.edu/consortiums
, click on FC)
.
11 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Term Definition
fabric a Fibre Channel switch of two or more Fibre Channel switches interconnected to physically
transmit data between any two N_Ports on the switch or switches
FC Fibre Channel
F_port a port in the Fibre Channel fabric where a N_port may attach
FL_port a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop
frame an indivisible unit for transfer of information in Fibre Channel
frame header the first field in the frame containing the address and other control information about the frame
full-duplex a communication protocol which allows transmission in both directions at the same time
half duplex a communication protocol which allows transmission in both directions, but only one direction at a
time
host a processor, usually a CPU and memory, which communicates with devices over an interface
initiator device a component which originates a command
L_port a port in an arbitrated loop, either a NL_port or a FL_port
LED Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
are used as indicator lights on all sorts of electronic devices
LUN Logical Unit Number: an identifier for a logical unit (0-7)
multi-mode fiber an optical fiber which can carry several beams of light at once
N_port a port attached to a node used with point to point or fabric configurations
NL_ port a port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration
originator an initiating device; a component which originates a command
parity checking a method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error message occurs if the sum is not correct
PCI Peripheral Component Interconnect. Allows peripherals to be connected directly to computer
memory, bypassing the slower ISA and EISA busses
point-to-point a topology where two ports communicate
port an access point in a device: see N_port, NL_port, etc.
port address also port number; the address, assigned by the PCI bus, through which commands are sent to a
host adapter board
port number see port address
receiver the ultimate destination of data transmission; a terminal device
scatter/gather a device driver feature which allows the host adapter to modify a transfer data pointer so that a
single host adapter can access many segments of memory, minimizing interrupts and transfer overhead
SCSI Small Computer Systems Interface: a processor-independent standard for system-level interface
between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers, scanners, etc.
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source
topology logical layout of the parts of a computer system or network and their interconnections
transceiver a transmitter/receiver module
transfer rate the rate at which bytes or bits are transferred, as in megabytes or gigabits per second
12
3 Hardware installation
You need a basic understanding of Fibre Channel before installing the Celerity FC host adapter. Please refer to
Fibre Channel is a key technology for storage
on page 11 for a list of related websites.
CAUTIONCAUTION
Back up your system data before changing or installing any hardware.
System requirements
The Celerity FC host adapter package contains the host adapter, the ATTO Utilities CD and a warranty and registration card. If any of these items are missing, contact your ATTO authorized sales representative.
To install and use the Celerity Fibre Channel host adapter you need
• A computer with an available PCI, PCI-X or PCI Express expansion slot
• The complete Celerity FC host adapter package
Fibre Channel address
Celerity FC adapters are configured with a unique address designated by the Institute of Electrical and Electronic Engineers. The WorldWide Port Name (WWN) and Node Name are the two components of the address assigned to Fibre Channel products. This address, stored in flash memory, allows the system to recognize the Celerity host adapter as a unique part of your configuration. The address is clearly marked on the back of the board for easy identification. Please keep a reference copy of the number in a safe place or write in the space provided on this page.
Celerity FC host adapter WWNs are assigned for each channel. The WWN listed on your host adapter is assigned to the first channel (0). Sequential WWNs apply for additional channels.
WWN 0 all adapters
WWN 1: 44ES, 42ES, 42XS, 24XL, 42EN
WWN 2 44ES, 24XL WWN 3 44ES, 24XL
Installation
CAUTIONCAUTION
Celerity FC host adapters contain components that are sensitive to electrostatic discharge (ESD). ESD can cause damage to the Celerity FC host adapter. Please follow standard methods to avoid ESD.
1 Power down the computer and unplug the
computer from all power sources.
2 Open the case.
3
Install the Celerity FC host adapter in any open
PCI, PCI-X or PCI Express expansion slot. If you have questions about how to install an expansion card in your system, consult your computer’s documentation.
Drawings of Celerity brackets begin on page 14 and drawings of boards begin on page 17.
Note
The Celerity FC-24XL, FC-41XS, and FC-42XS host adapters only fit in 3.3V slots.
The Celerity FC-44ES and FC-42ES (non RoHS) fit in x8 or x16 mechanical PCI Express slots.
The Celerity FC-42ES (RoHS), FC-41ES, FC­41EN and FC-42EN fit into x4, x8, or x16 mechanical PCI Express slots.
If you have trouble seating your adapter in a 32­bit PCI bus computer, check to make sure the connector can accommodate 64-bit host adapters.
4 Connect Fibre Channel devices by inserting a
Fibre Channel cable from the devices to the connectors on the Celerity FC host adapter until you hear a click.
5 Close the case on the computer and power it
up.
13 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Bracket details
Exhibit 3-1 FC-41EN Adapter Exhibit 3-2 FC-42EN Adapter
14
Exhibit 3-3 FC-44ES Adapter
Exhibit 3-5 FC-41ES Adapter
Exhibit 3-4 FC-42ES Adapter
Exhibit 3-6 FC-42XS Adapter
15 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Exhibit 3-7 FC-41XS Adapter Exhibit 3-8 FC-21PS Adapter
Exhibit 3-9 FC-24XL Advanced Adapter
16
Adapter board details
Exhibit 3-10 FC-41EN
Exhibit 3-11 FC-42EN
17 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Exhibit 3-12 FC-44ES
Exhibit 3-13 FC-42ES Non-RoHS
18
Exhibit 3-14 FC-42ES RoHS
Exhibit 3-15 FC-41ES
19 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Exhibit 3-16 FC-42XS
Exhibit 3-17 FC-41XS
Exhibit 3-18 FC-21PS
20
Exhibit 3-19 FC-24XL
21 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
22
4 Installing and updating drivers
After installing your Celerity adapter, you must configure your system to recognize and use it by installing drivers for your operating system.
Configure your system to recognize and use your Celerity adapter by
• installing drivers for your operating system
• updating the adapter firmware if necessary (refer to Updating hardware flash
Note
If you already have one or more Celerity adapters installed and you are installing additional adapter(s), you do not need to perform any of these procedures unless you are updating a previously installed driver.
on page 26)
Specialized configurations
Some specialized applications may benefit from modification of adapter settings. The ATTO Utilities Installation and Operation Manual provides detailed information on using ATTO Technology configuration utilities found on the ATTO Utilities CD or downloaded from the ATTO website. For best performance, use the most recent device driver and flash version.
Verify the version based on your operating system.
Windows:
from the ATTO Utilities CD, or download it from
www.attotech.com
string during system boot or look in the
Manager
Use the ATTO Configuration Tool
, or view the adapter boot
Device
.
ATTO Celerity adapters ship with the latest firmware installed.
The Celerity FC Installation CD shipped with your adapter contains the latest driver.
The Installation CD automatically starts when inserted in the system CD-ROM drive. Navigate the easy-to-use HTML-based menu to find the driver that you want to install.
If the CD does not automatically start, open the CD and click on
Note
Windows NT is only supported with Celerity driver version 1.31 or earlier. If you are using Windows NT, contact your service representative.
Mac OS X
autorun.bat
.
: Use the ATTO Configuration Tool on
the ATTO Utilities CD, or download it from
www.attotech.com,
or use the Apple System
Profiler.
Linux
: Use the ATTO Configuration Tool on the
ATTO Utilities CD, or download it from
www.attotech.com
examine
/proc/scsi/celerityfc/X
, or to find the driver version,
, where X is the
adapter’s host number.
Windows 2000/XP/Server 2003
Five procedures are described below. Review each thoroughly to ensure that you are using the one that best fits your needs. If you have one or more Celerity FC adapters installed in your system and you are installing additional adapter(s), you do not need to perform any of
23 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
these procedures unless you are updating a previously installed driver.
The Celerity FC Installation Disk can be the Installation CD shipped with your adapter, a folder containing the latest downloaded and expanded driver, or a Celerity FC installation floppy disk.
Upgrading an existing Celerity FC driver
1 Log on to Windows as the System
Administrator.
2 Insert your Celerity FC Installation Disk and run
autorun.bat
3In Windows Drivers, select your operating
system version.
4 Click on Install Driver.
Adding a Celerity FC adapter to an existing installation
Note
Complete this installation procedure before attaching any devices to the adapter.
1 Complete the steps in Updating hardware flash
on page 26 to pre-install the driver.
2 Close Windows and turn off power to your PC
when Setup prompts you to do so.
3 Install your new Celerity FC adapter into an
available PCI expansion slot. a. If the Celerity FC adapter is replacing
another adapter in the system, disconnect the FC cables from the adapter and remove the adapter from the system, or move the Celerity FC adapter to the PCI slot that the previous adapter occupied.
b. Attach the appropriate FC cables to the
Celerity FC adapter.
4 Close the computer chassis
5 Turn on the power and restart Windows.
6 During the boot process, Windows detects your
Celerity FC adapter and the Found New Hardware Wizard is displayed.
Follow the directions in the Found New Hardware Wizard, selecting the default settings for each adapter channel.
7 Insert the Celerity FC Installation disk when
asked to do so.
8 When adapter installation is complete, the
Found New Hardware Wizard displays an ATTO Phantom Device for each channel. Use
the wizard default settings to complete the installation.
Creating a boot disk
Note
The procedure described below does not apply to Windows Server 2003 for Itanium systems because the Celerity FC driver does not support boot functionality on Itanium systems.
1 Start Windows text mode setup as found in the
instructions provided with Windows.
2 Press F6 when Windows Setup, displays. The
setup program displays a prompt in the status window on the bottom left of the monitor. Setup continues to load files after you press F6.
3 A new window displays instructions to specify
additional mass storage devices. Press S to install the ATTO Celerity as a storage device.
4 Insert the Celerity FC installation diskette in
drive A and press Enter.
5 A screen displays a list of Celerity FC adapters.
Select your adapter and press Enter.
6 Windows Setup loads the files from the floppy
and then displays the screen described in Step
2. The ATTO Celerity FC device should now be
listed as detected.
7 Repeat steps 2
supplied driver installation disks.
8 After all other drivers have been processed,
press Enter and proceed with the rest of the Windows installation procedure.
Note
When Windows begins copying files to your hard disk, a display prompts you to insert the Celerity FC installation disk and any other vendor-supplied disks you used during custom installation. This is normal. The first time you inserted the disks, Windows loads the drivers into memory; the second time you insert the disk(s), Windows copies the driver to your hard disk.
to 6 for any other vendor-
24
Creating a Celerity FC installation floppy
Note
You must have a floppy disk with the Celerity FC driver software to install a fresh copy of the Windows OS onto a disk attached to a Celerity FC adapter.
1 Insert the Installation CD into a CD-ROM. The
installation starts automatically.
If the Celerity FC installation does not start, navigate to the root of the CD and run autorun.bat
2Select Windows Drivers from the items on the
left side of the screen.
3 Select the appropriate CPU-based operating
system from operating system choices.
4Select Create Miniport Driver Diskette or
Create StorPort Driver Diskette for the desired operating system.
5 Follow the instructions for creating the floppy
disk.
Creating a floppy disk from a download
1 Download the latest driver software from the
2 The download is a self-extracting executable
3 Navigate to the folder with the desired Celerity
4Run makedisk.bat and follow the instructions
Mac OS X driver installation, update
ATTO website,
that expands the driver software package. Run the self-extracting executable and select a folder to place the expanded software package.
FC driver.
Note
The expanded software package contains a Miniport driver and may contain a StorPort driver. The Celerity FC Windows Miniport driver is in the base directory of the expanded software package. The Celerity FC Windows StorPort driver is in the StorPort subdirectory.
for creating the floppy disk.
www.attotech.com.
1 Extract the latest version of the device driver file
to your desktop.
2 Double click the installer icon and follow the on
screen prompts.
Linux driver installation, update
Note
You must have kernel header files for the appropriate kernel installed.
You must be logged in as
1 At the command prompt type rmmod
celerityfc
root
.
3 Reboot your system for the changes to take
effect.
2 Download the appropriate version of the device
driver from the ATTO website.
3 At the command prompt, extract the file using
the command tar -xfz <filename.tgz>
4 Enter the directory created in the above step
and type make install to overwrite any previously-installed driver.
5 Start the driver by typing modprobe celerityfc
25 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
5 Updating hardware flash
Your Celerity FC host adapter was flashed before shipment, but the flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt. Visit the ATTO website,
www.attotech.com
, to download the latest drivers and flash bundle.
Hardware flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt.
Updating flash in all operating systems
1 Download the most recent version of the
Configuration Tool from the ATTO website.
Refer to the ATTO Utilities Installation and Operation Manual for additional information on downloading and using the Configuration Tool.
2 Download the proper flash bundle (adapter
specific) from the ATTO website.
3 Extract these files to your desktop.
4 Install the Configuration Tool on your system.
5 Launch the Configuration Tool.
6 In the Device window, select the adapter that
needs to be updated.
7 In the Flash window, click on the Browse
button to find the flash bundle that you previously downloaded to your desktop.
8 Click Update to update your flash ROM.
9 Reboot your system for the changes to take
effect.
Updating flash on a PC
You may update hardware flash on a PC using BIOS utilities.
Note
BIOS utilities do not work on Itanium systems. Use the ATTO Configuration Tool to update flash on Itanium systems.
1 Download the latest driver software from the
ATTO Technology website.
2 The download is a self-extracting executable
that expands the driver software package. Run the self-extracting executable and select a folder in which to place the expanded software package.
The expanded software package contains a Miniport driver and may contain a StorPort driver. The Celerity FC Windows Miniport driver is in the base directory of the expanded software package. The Celerity FC Windows StorPort driver is in the StorPort subdirectory.
3 Navigate to the folder with the desired Celerity
FC driver.
4Run makedisk.bat and follow the instructions
for creating the floppy disk.
Note
The flash update must be loaded from a floppy because CD-ROM drivers are not loaded at this point in the system boot process.
5 Reboot the PC.
6 During the reboot, an ATTO Technology
banner displays that the host adapter was detected.
7 Enter Control-F when prompted to begin the
set-up utility within a few seconds after the banner appears.
If you do not enter Control-F soon enough after the banner appears, repeat steps 5 and 6.
8 In the utility, select the Upgrade Flash ROM
option.
9 Insert the disk into the drive slot.
10 Follow the on-screen instructions.
11 Remove the disk and reboot your system for
the flash ROM changes to take effect
26
6 Troubleshooting
This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website, authorized ATTO Technology representative.
www.attotech.com
, or contact an
General suggestions
• Check each cable connection on every device.
• Verify all cables are in proper working condition. Loose or broken cables are often the cause of errors or problems.
Mac OS X
Note
The Celerity FC supports Mac OS X versions
10.3 and later.
1 Open the ATTO Configuration Tool from the
ATTO Utilities CD or download from the ATTO website. Refer to the ATTO Utilities Installation and Operation Manual for additional information.
2 If the adapter does not appear in the Device
Listing, make sure it is properly seated in the PCI slot.
a. Remove power from the PC. b. Remove the case. c. Check the PCI slot. d. Replace the case. e. Apply power.
Note
If the Celerity adapter is properly seated and devices are still not accessible, contact an authorized ATTO representative.
• Check that Fibre Channel devices are plugged into an AC outlet and are turned on before you add power to your computer.
3 Verify the driver is loaded.
a. Click on the adapter name in the
Device Listing to view the Basic Info screen.
b. If the Driver Information section
indicates Unknown: driver not loaded, reinstall the driver. Refer to
Installing and updating drivers
23.
c. If reinstalling the driver does not fix the
problem, contact an authorized ATTO representative.
4 Reset the NVRAM for all channels to defaults
and reboot. If the problem persists, contact an authorized ATTO representative.
Note
When calling ATTO Technical Support, please have a printout of the IOreg listing and output from the Apple System Profiler available.
on page
Windows 2000/XP/Server 2003
• If the card has been recently re-flashed, the new Windows driver must be installed. Follow the procedure in Installing and updating drivers page 23.
• All of the external devices connected to the host adapter should be identified. If they do not appear in the Device Manager, the external devices or connection may not be working properly.
• For Intel-based PCs, check the computer CMOS setup and verify that the PCI slots are configured correctly.
27 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
on
• Procedures vary greatly: refer to the manual supplied with your system or call the computer supplier for configuration assistance.
• Windows 2000/XP/Server 2003 are Plug-n-Play operating systems: be sure your computer’s BIOS is set accordingly.
• If these do not solve the problem, re-flash the host adapter and re-install the Windows 2000/XP/Server 2003 driver. See Installing and
updating drivers on page 23.
If the devices connected to the Celerity FC host adapter are not accessible
1 Right-click My Computer.
2Select Properties.
3 Select the Hardware tab.
4Select Device Manager.
• If the Celerity FC host adapter does not appear under the SCSI and RAID controllers, remove power from the PC, open the case, and check that the Celerity FC adapter is properly seated in the PCI slot. Replace the case and apply power.
Linux
• If the adapter has been identified but there is an exclamation point (!) on the listing, right click on the listing and select Uninstall.
5 Reload the driver (see Installing and updating
drivers on page 23).
6 Reboot the system and repeat the installation
process.
7 If problems persist, contact your authorized
ATTO Technology representative.
1Verify the celerityfc driver is loaded with the
lsmod
command. If lsmod does not show the driver, refer to the installation instructions to install and load the driver in Installing and
updating drivers on page 23.
2 Check the system log with the command
dmesg
messages during initialization. Make sure that all installed cards are properly detected and initialized.
. The celerityfc driver creates status
3 Examine the contents of the file(s)
/proc/scsi/celerityfc/X, where X is the adapter’s host number. This file contains details such as link status, connection speed and discovered devices.
Note
Advanced users only. Modify the
makefile
Upon loading, the detailed debugging information which may help troubleshoot the problem.
to enable debugging information.
celerityfc driver
driver
displays
28
Appendix A Standards and compliances
The equipment described in this manual generates and uses radio frequency energy. The Technical Specification sheet for a particular Celerity FC host adapter list certifications for that model.
FCC standards: radio and television interference
WARNING
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Canadian standards
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European standards
Declaration of Conformity
This following statement applies to the Celerity FC host adapter.
This device has been tested in the basic operating configuration and found to be compliant with the following European Union standards: Application of Council Directive: 89/336/EEC
Standard(s) to which conformity is declared: EN55024:2002; EN55022:2002 CLASS B
This Declaration will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant.
Some ATTO Celerity cards comply with Directive 2002/95/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO representative regarding RoHS compliant products.
i ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Usage restrictions
The use of optical instruments with this product will increase eye hazard.
The multimode transceiver is a Class 1 laser product complying with IEC 825-1 and FDA-21 CFR
1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum ratings. The laser is non-OFC compliant as it is a Class 1 device.
The optical ports of the modules must be terminated with an optical connector or with a dust plug.
CAUTIONCAUTION
Failure to adhere to the above restrictions could result in a modification that is considered an act of “manufacturing” and will require, under law, recertification of the modified product with the U.S. Food and Drug Administration (ref. 21 CFR 1040.10(i)).
The following apply to the Celerity FC-42XS host adapter only
This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.
ii
Appendix B Accessories
The following Fibre Channel accessories are available through ATTO Technology and authorized resellers. Contact an ATTO Technology authorized sales representative to order.
Optical Cables
CBL-FCFI-05x 5 m. cable– Duplex 50 Micron Multi-mode FC/Optical CBL-LCSC-003 3 m. 50/125 optical cable (LC to SC) CBL-LCSC-010 10 m. 50/125 optical cable (LC to SC)
A variety of iSCSI, Fibre Channel and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information.
Fibre Channel and iSCSI solutions
ATTO FibreBridge ATTO iPBridge iSCSI to SCSI, iSCSI to Fibre Channel bridges
SCSI solutions
ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix C)
Software
ATTO Utilities Configuration and management software ATTO ExpressStripe for OSX Mac OS X RAID and benchmark software ATTO Express Power Center Windows-based striping utility
TM
Fibre Channel-to-SCSI bridge
iii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Appendix C SCSI adapter selection guide
Ultra 320
Product Features UL5D UL4D UL4S
Maximum Transfer Rate (MB/sec.)
Low Voltage Differential 999
Single-ended SCSI 999
Number of SCSI channels
Number of SCSI IDs supported
Cable distances (m)
Large file transfers 999
32-bit PCI compatible 99
64-bit PCI compatible 99
33 MHz PCI 99
66 MHz PCI 99
133 MHz PCI-X 99
x4 PCI Express 9
Windows 2000/XP, Server 2003 support 999
Linux 999
640 640 320
221
30 30 30
12.5 12.5 12.5
Mac OS X support 999
Novell Netware support 999
RoHS compliant version 999
iv
Appendix D Contact ATTO Technology, Inc.
Customer service, sales information and technical support are available by phone Monday through Friday, Eastern Standard Time 8:00 a.m. to 8:00 p.m., or by e-mail and website 24-hours a day.
ATTO Technology, Inc. 155 CrossPoint Parkway Amherst, New York 14068 (716) 691-1999 • voice (716) 691-9353 • fax
http://www.attotech.com
ATTO Technology can also be reached via e-mail at the following addresses:
Sales Support: sls@attotech.com Technical Support: techsupp@attotech.com
v ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
vi
Loading...