Ultra Lif
USER MANUAL
REV 0 [05/XX] SheLine-VRTM USER MANUAL | 1 00000XXX
Intellectual Property Rights
Purpose /Use/Use Prohibition Reasons/Attention
Purpose /Use/Use Prohibition Reasons/Attention
1. Product Introduction &
Components
1.1 Introduction to the product
1.2 Components and functions of the product
1.3 Signs used in the manual and the product
2. How to Prepare for Use
2.1 Checkpoints before use
2.2 Power supply and charging checkpoints
3.1 How to use the product
4. How to Maintain and Keep
4.1 Attention for management
4.2 Attention for storage
4.3 Preparation for transport
4.4 How to wash and clean
5.1 Measures in emergency
5.2 Treatments by failures
6.3 Matters excluded in warranty service in warranty period
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 2 00000XXX
Copyright ⓒ 2016 ATTIBE Beauty Corporation
The product described in this document is protected under domestic and foreign intellectual
property rights in various laws including Industrial Property Act and Copyright Act. Illegal
copy or use is not allowed without any written consent of attibe co., ltd
.
Intellectual Property Rights
The intellectual property rights pertinent to Ultra Lif described in this document include all
patents and trademarks applied for and registered in Korea and other countries. All rights
for the product are protected by relevant intellectual property rights.
The product described in this document is protected by our intellectual property rights
including our patent and family patent, trademark, and design right. Therefore, it is
revealed that illegal use violates our intellectual property rights and thereby can cause civil
and criminal punishments.
Patent applied for in
Korea
Trademark registered
in Korea
Design applied for in
Korea
Patent applied for
overseas
This product is an ultrasonic device used personally or at home. It converts electric energy to
ultrasonic waves, and ultrasonic energy to heat energy so as to be applied for the purpose of
improving skin elasticity.
A user is required to read this manual fully before using this product.
Incorrect use of the equipment may damage the equipment or human body. However,
our company has no liability for such damage.
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 3 00000XXX
Reasons for Use Prohibition
Ultra Lif should not be used by some persons or patients who have the following symptoms:
* Children
* Pregnant women
* Persons with opened injury
* Persons with severe or follicular acnes
* Persons with sensitive skin
* Persons with metal stent on the region to use
* Persons with bioabsorbable implant
* Persons with hypertrophic scars
*Persons with implantable medical appliances influencing electromagnetic waves (e.g., cardiac
pacemaker, implantable cardiac defibrillator, implantable electric stimulator, implantable electrical urinary
incontinence device)
* Persons with whole or local skin diseases that may influence injury healing process
It is unknown about the result of an operation of Ultra Lif to persons who have insert-typed
devices, like defibrillator or pace maker.
* Make sure to use ultrasonic gel for the product.
* If the product runs in the condition that it fails to get close to skin after ultrasonic gel is applied, a
scratch can occur in skin. In this case, apply an ice pack and a burn ointment.
* After use, if you give another use or a different use to the same region, consult with your medical
doctor.
* If you already have filler, autologous fat grafting, and others recently, do not apply the product to
the region.
* About 1 week after use, avoid severe exercise, sauna, or hot spa.
* Avoid drinking.
* Apply plenty of moisture cream and sun cream.
* Do not starch or touch on the applied region, though itchy.
If any potential safety issue or something abnormal is found in use, immediately stop using the
product and contact Customer Service of attibe beauty (Tel. 1661-7599).
To prevent this product from causing any secondary infection, a user should keep the contact part
of the product clean.
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 4 00000XXX
Using Ultra Lif with other equipment is not tested. Therefore, such a case may cause unexpected
result.
Read fully this user manual
before using Ultra Lif system.
Ultra Lif Customer Service
Customer Support Center: Tel. 1661-7599 Website: www.attibe.com
The side effects reported by the clinical test of Ultra Lif system are few or temporary as shown in
each of the following:
* Erythema: this side effect can be found in the applied region, but disappears after 48 hours,
generally.
* Edema: the applied region can be swollen temporarily after an operation.
* Pain: instantaneous inconvenience may occur in an operation.
* Bruising: Very rarely, a little bruising may occur within 48-72 hours after an operation.
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 5 00000XXX
The following signs are displayed on supplies and packages provided together with the system
components and the system.
BF Type-Portable Patient
Product; now allowed to
use together with
defibrillator
Electromagnetic
Interference Possibility
This electric device
should be disposed of in
a special way.
This waste battery
should be disposed of in
a special way.
※ It is recommended to read well the above Signs and their description before use.
Label
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 6 00000XXX
Ultra Lif System User Manual describes system components, operation method, trouble shootings
of the equipment, washing, and maintenance in detail.
Ultra Lif Product provides the manual of the main body, cartridge, cradle (main body support),
and others.
System User Manual describes system components, operation method, trouble shootings of the
equipment, washing, and maintenance in detail.
For Ultra Lif system, it is allowed to change the contents of the user document at any time.
Before using the system components, please take and read fully the latest user document.
All images included in Ultra Lif User Document are sample images.
The actual system hardware and information can be different from in the
document.
This sign indicates that a user may lose its life or get damaged severely
unless following the user manual.
This sign indicates that a user may get damaged or have a property loss
unless following the user manual.
This sign means the important information on product operation.
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 7 00000XXX
Product Introduction
& Components
1. Product Introduction and Components
1.1. Introduction to the product
Ultra Lif system supplies high-frequency pulses to concave ultrasonic ceramic to generate
ultrasonic waves and delivers them. Through the ultrasonic waves, heat is imposed on tissues.
Frictional loss arises during energy absorption and thereby a coagulation zone is created.
1.1.1. Overview of Ultra Lif
1.1.1.1 Electrical spec.
a) Protection grade and type for electric shock: Internal Power BF Type Device
b) Rated voltage and power consumption: 100-240VAC, 50/60 Hz, 1.5A
c) Technical spec.
● Battery : 11.1VDC, 750mAh
● Display: 1.2 Inch MONO LCD
d) Safety device
If something abnormal occurs in use, Black Light on the display window is turned on 2
minutes. And “ERROR” icon flickers on the display window.
In addition, an alert rings at an interval of 0.2 second. In this case, the product stops
running.
Abnormal phenomena detected are presented as follows:
● Non-recognition of cartridge
● Failure to initialize contact sensor
● Location error of ultrasound occurrence part (transducer) in cartridge
● The internal temperature of cartridge and main body exceeds a setup temperature.
1.1.1.2. . Mechanical spec.
a) Main Body[W×D× H]: 341 x 344 x 254mm
b) Cartridge[W×D× H]: 338 × 412 × 748mm
c) Cradle [W×D× H]: 53.5 mm x 76.6mm x 55.5
d) Micro 5 PIN USB, Cable length: 1.5M
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 8 00000XXX
Product Introduction
& Components
1.2 Components and functions of the product
1.2.1 Components of the product
Ultra Lif has the components as follows:
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 9 00000XXX
Product Introduction
& Components
1.2.2 2Name and function of each product component
1.2.2.1 Main Body (cartridge included)
Displays the operation status of the product on LCD
When the button is clicked, power is On or Off.
LCD for displaying the operation status and selecting a level
The component of ultrasonic output
Cartridge
Separation Button
This button keeps being pushed to separate the cartridge from the
main body.
Ultrasonic
Irradiation Part
Ultrasonic waves are generated by the part which has transducer built
in.
REV 0 [03/16] Ultra Focus Skin Lif User Manual | 10 00000XXX
Product Introduction
& Components
The component to get hold of the device
Components for connecting with the cartridge
The component for connecting between the cartridge and the
main body circuits
The joint gear for connecting with cartridge rotating axis
The component for connecting and separating with the
cartridge