ATTIAS
MANUFACTURERS OF ATTIAS DOUGH MIXERS
COMMERCIAL DOUGH MIXERS
INSTALLATION AND OPERATING
INSTRUCTION MANUAL
MODEL# USA-60
MODEL# USA-80
Installation, Operation and Care of USA-60 and USA-80
ATTIAS COMMERCIAL DOUGH MIXERS
SAVE THESE INSTRUCTIONS
GENERAL SPECIFICATIONS
ATTIAS USA-60 model mixer is a heavy duty 60 quart mixer which features a 5
horsepower motor, a timer and a # 12 attachment hub, with the use of bowl adapters
and special agitators.
ATTIAS USA-80 model mixer is a medium duty 80 quart mixer designed primarily for
use in general kitchen applications. This mixer features a timer and # 12 attachment
hub as standard equipment and is powered by a 5 horsepower motor.
ATTIAS USA-80 mixer is heavy duty 80 quart mixer which features a 5 horsepower
motor, a timer and a #12 attachment hub, with the use of bowl adapters & special
agitators.
ELECTRICITY- 208/220/240 – single phase or 3 phase
*AVAILABLE IN 50 CYCLES FOR OVERSEAS/INTERNATIONAL USE*
ALL MIXERS COME WITH:
-Stainless Steel Bowl
-Dough Hook
-Flat Beater
-Wire Whip
OPTIONAL
-Bowl Dolly
-Cheese Grater Attachment
-Meat Grinder Attachment
-Vegetable Shedder Attachment
INSTALLATION
UNPACKING
Immediately after unpacking the mixer, check for possible damage. If this machine is
found to be damaged after unpacking, save the packaging material and contact the
carrier with in 15 days of delivery.
Prior to installation, test your local electrical service to assure that it agrees with the
specifications on the machine plate. Call Attias with any questions.
LOCATION
Place the mixer in its operating location. There should be adequate space around the
mixer for the user to operate the controls and install and remove bowls. The area above
the mixer should allow the top cover to be removed for routine maintenance and
servicing.
CHECK LUBRICATION BEFORE USE
This mixer is shipped with oil in the transmission and planetary. Check oil levels before
starting mixer. Refer to LUBRICATION, for applicable lubrication procedures.
ELECTRICAL CONNECTIONS
WARNING:
COMPLY WITH THE APPLICABLE PORTION OF THE NATIONAL
ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING:
TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE
WORKING ON THE CIRCUIT.
USA60 208/220/240 Single or 3 Phase *available in 50 cycles for overseas*
USA80 208/220/240 Single or 3 Phase *available in 50 cycles for overseas*
ELECTRICAL AND GROUNDING CONNECTIONS MUST
DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A
ELECTRICAL DATA
Model Volt/Hz/Ph Phase Cycle