DCU & Transmitter Field Installation Manual
1
Version 1.0 ElmoTech Ltd
2
DCU & Transmitter Field Installation Manual
ElmoTech Ltd Version 1.0
TABLE OF CONTENTS
Section Page
THE MONITOR CENTER/ PROBATION AGENCY ..................7
IGURE 7 DISCONNECTING THE TRANSMITTER.................................... 29
DCU & Transmitter Field Installation Manual
5
Version 1.0 ElmoTech Ltd
6
DCU & Transmitter Field Installation Manual
ElmoTech Ltd Version 1.0
THE MONITOR CENTER/
PROBATION AGENCY
At the Monitor Center/Probation Agency:
1. Enter the Offender’s data in the monitoring application.
This can be done well in advance, even before the actual
equipment is allocated and installed.
2. Enter the following equipment data in the monitoring
application.
• DCU Serial No. - Check that the number entered
matches the number on the DCU unit.
• Transmitter Serial No. - Check that the number
entered matches the number on the Transmitter.
The DCU and Transmitter Serial numbers are visible
on the back of each unit.
DCU & Transmitter Field Installation Manual
7
Version 1.0 ElmoTech Ltd
Equipment
Check that you have all the required equipment:
• DCU unit and power adapter
• Transmitter
• Electronic key
• Locking device
• Strap holder
• Strap clips (male and female)
• Screwdriver (to open a clip if necessary). It is
recommended to use a 5 mm flat head screwdriver.
It is always advisable to bring an extra set of strap
clips to cater for the event in which the first set may be
accidentally damaged during the installation.
8
DCU & Transmitter Field Installation Manual
ElmoTech Ltd Version 1.0
THE OFFENDER’S PREMISES
Monitoring System Location
In order to install the Monitoring System, you will need to find
the best location for the DCU unit. The ideal
unit is in the center of the house, 3 feet off the ground and at
least 1 foot away from the wall.
place for the DCU
Figure 1 Ideal DCU Location
DCU & Transmitter Field Installation Manual
9
Version 1.0 ElmoTech Ltd
The DCU unit should be in an open area away from other
electrical appliances (e.g. personal computers, laptops) or any
metal objects.
Installing the DCU Unit
In order to install the DCU unit:
1. Plug the appropriate end of the power adapter cord into
the 12VDC socket at the back of the DCU unit.
2. Plug the power adapter into a wall power socket. The
DCU unit makes an audible beeping sound and then runs
through a series of built-in-tests to check that everything
is in order.
3. After completing the tests successfully the DCU unit
beeps again and the two external LED’s, located at the
rear of the DCU unit, are turned on. This indicates that the
DCU unit is in working order. The LED indicators are:
• Left LED - indicates that power is connected
• Right LED - indicates that the DCU unit has
registered to a telephone network (network
registration may take up to one minute after built-intest completion).
10
DCU & Transmitter Field Installation Manual
ElmoTech Ltd Version 1.0
Figure 2 Diagrammatic View of a DCU
If, at the end of the start-up self test, audible beeping
sounds are heard and all three LED’s flash for 10
seconds, it indicates one of the following possible
failures:
i
Case open micro-switch malfunction.
i
Tilt sensor malfunction.
i
Range threshold values lost (maximum reception
range is used in this case).