Base Unit 3000 Operating Features ................................................................................................................................................. 4
Base Unit 3000 LEDs ....................................................................................................................................................................... .5
Bracelet Operating Features ............................................................................................................................................................ .6
Enroll a Contact ............................................................................................................................................................................ .8
Contact Information Page ........................................................................................................................................................... .11
Enroll an Offender ....................................................................................................................................................................... .12
Offender General Information Page ............................................................................................................................................ .17
Create Schedule for Curfew ............................................................................................................................................................ 18
Activating the Base Unit 3000 ....................................................................................................................................................... .25
Equipment Range Test ................................................................................................................................................................ 38
Issue Date: 8/19/2015
2
Overview
3M Electronic Monitoring’s Home Curfew RF Monitoring System provides an effective curfew compliance system.
3M Electronic Monitoring’s Home Curfew RF Monitoring System consists of three main components: The 2 Way
Bracelet, the Base Unit 3000, and 3M Electronic Monitoring’s EM Manager (Smart View) Software.
2 Way Bracelet
• Serves as an electronic tether to the Base Unit 3000
Base
Unit 3000
• A small stationary device used to monitor the presence of the ankle bracelet and transmit
information via cellular network.
EM Manager (Smart View)
• The monitoring software that can be installed on almost any computer with Internet access. EM
Manager (Smart View) provides access to reports and offender’s information.
Issue Date: 8/19/2015
3
Base Unit 3000 Operating Features
Communication: The Base Unit 3000 will call 3M Electronic Monitoring to download event data every 6 hours. If the contract specifies, it will also call out immediately upon a violation or “Home” or “Away” status change.
Motion Sensor: There is a motion sensor located inside the Base Unit 3000 to allow it to determine if it is being
moved.
30 Day Event Memory: The Base Unit 3000 will store up to 11,000 events. This is useful in the event that the Base
Unit 3000 loses cellular coverage. The Base Unit 3000 will continue to store the information and will send the
information to 3M Electronic Monitoring when cellu lar covera ge is restored.
48 Hour Battery Backup: If the Base Unit 3000 loses power, it has a 48 hour back-up battery that will allow the Base
Unit 3000 to record and store events, as well as transmit the data to 3M EM, if cellular coverage is available.
Multiple Bracelet Tracking: Each Base Unit 3000 can track up to 15 offenders.
Incoming Calls: The Base Unit 3000 is capable of accepting calls from the Monitoring Center.
Outgoing Calls: The Base Unit 3000 is capable of making outgoing calls to a preprogrammed number.
Issue Date: 8/19/2015
4
Base Unit 3000 LEDs and Buttons
Power: The Power LED is solid green when connected to a power source. If the Base Unit 3000 loses power, the
LED will blink red once per second.
Cell/Line: If solid green, the phone line is in use. If cellular coverage is not available at the time of a call, the Base
Unit 3000 will continue to try and call in. The line LED will continue to turn on and off until a call is completed. If
cellular coverage is lost, the Line LED will blink red.
Curfew: When the Curfew LED is blinking red, the offender is not in range of the Base Unit 3000 when the curfew
schedule is in effect.
Ring: The Ring LED will blink red once per second when the device receives a call.
Answer Button: When the device receives a call, hold the Answer button for one second. The device will beep to let
you know that you have answered the call.
Hang Up Button: When the call is complete, press the Hang Up button. The device will beep to let you know that the
call is complete.
Call Button: To make a call to the preprogrammed number, hold the Call button for five seconds.
Issue Date: 8/19/2015
5
2 Way Bracelet Operating Features
Electronic Tether
The bracelet serves as an electronic tether to the Base Unit 3000. The bracelet communicates with the Base Unit
3000 via Radio Frequency.
Adjustable Range
The distance allowed between the bracelet (offender) and the Base Unit 3000 is adjustable. Low Range is
approximately up to 50 ft. Medium Range is approximately up to100 ft. High range is approximately up to150 feet.
(This is clear line of sight and is also dependent on environmental conditions.) The default is set to High range. The
range can be adjusted on the Curfew rule of the EM Manager (Smart View) software.
Waterproof
The bracelet is waterproof down to 66 feet.
Battery Life
The bracelet battery is designed to last approximately 12+ months while in use and has a 2 year shelf life.
Hypoallergenic Rubber Straps
The bracelet comes with a hypoallergenic rubber strap that contains a fiber optic cable designed to prevent
tampering.
Tamper Detection
If an offender interrupts the infrared light, located inside of the fiber optic cable, inside of the bracelet strap, an alarm
will occur.
Issue Date: 8/19/2015
6
Enrollment
EM Manager (Smart View) Log In
To access the secure website, go to https://smartview.ptm.com
password. When using EM Manager (Smart View) for the first time, you will create your own password. Enter your
User ID (often your three initials and last four digits of your social security number), the temporary password that was
emailed to you, and click OK. The next screen will tell you that your password has expired. Create your password,
(
the password you select must contain at least 8 characters), and click OK. You will now be logged into EM
Manager (Smart View).
Note: If you forget your password, click the Forgot your Password link. A new temporary password
will be emailed to you. To create your new password, follow the instructions contained withi n the
email.
. You will be required to enter a user ID and
Issue Date: 8/19/2015
7
Enroll a Contact
The Enroll Contact link is located on the left side of the Home page (see below). It is here that you will enter the
officer’s information (name, address, phone number, etc.), report types, and default notification settings.
1. Click the Enroll Contact link on the left side of the Home page.
2. You will be redirected to the Enroll Contact page (see below). Enter all Contact information.
3. Click Save.
Issue Date: 8/19/2015
8
Enroll a Contact, cont.
Issue Date: 8/19/2015
9
Enroll a Contact, cont.
Demographic Data
1. Enter the Contact’s information.
• All fields with red asterisks (*) are required fields.
Report Options
2. Enter an email address where the selected reports will be sent.
4. Select the type of Notification you would like to be your default method. The notification method is
dependent upon the information that you enter into the Notification Email or Text Message fields.
• Pager
• Fax
• E-mail
• Text Message
Finish Enrollment
5. When you have completed the form, click Save.
Issue Date: 8/19/2015
10
Contact Informa tion Page
When you click Save, you will be taken to the Contact Information page (see below). Here, you can edit the contact
information, as well as disable the contact.
1. To edit the contact information, move your mouse cursor over the Contact Functions dropdown menu and
left click Edit.
2. To disable the contact, move your mouse cursor over the Contact Functions dropdown menu and left click
Disable Contact.
Issue Date: 8/19/2015
11
Enroll an Offende r
The Enroll Offender link is located on the left side of the Home page (see below).
1. Click the Enroll Offender link.
Issue Date: 8/19/2015
12
Supervision Level
Clicking on the Enroll Offender link will redirect you to the Level of Supervision page (see below).
1. Click on the Level of Supervision drop down menu.
2. Select your Level of Supervision (see below).
3. Click the Continue button.
Issue Date: 8/19/2015
13
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.