ATTACK DP25, DP 35, DP45, DP75 Technical Manual

ATTACKDP
WOODGASIFYINGBOILER
R
TECHNICALMANUAL
ATTACKDP-Woodgasifyingboiler
-Assembly,pre-heatingandtrainingoftheattendanceisperfomedbyanassemblytechnician trainedbythemanufacturer,whoalsofillsinadocumentontheinstallationoftheboiler
-Duringwoodgasifying,tarandcondensates(acids)arecreated.Therefore behindtheboilerthemixingapplianceregumatortemperature-responsivevalvemustbe installed,tokeeptheminimumtemperatureofreturnwaterof65intotheboiler.
-Operationtemperatureofwaterintheboilermustbeof80-90°C.
-Theboilermustnotbepermanentlyoperatedwiththeoutputlowerthan50%.
-Whenacirculationpumpisused,itmustbecontrolledbyaseparatedthermostatinorderto keeptheprescribedminimumtemperatureofreturnwater.
-Ecologicaloperationoftheboilerisduringnominaloutput.
-WerecommendtoinstalltheboilerwithstoragereservoirsandRegumatwhichguarantees economyinfuelin20až30%andlongerservicelifeoftheboileraswellascomfortable attendance.
-Iftheboilercannotbeattachedtotheaccumulation,werecommendtoconnectitatleast withoneequalisationbasinwiththevolumeofabout25lfor1kWoftheboileroutput.
-Duringthemodewithdecreasedoutput(summermodeandwaterheating)itisnecessaryto startburningdaily.
-Fuelmustbeusedonlydriedof12-20%moisturecontent(withahighermoisturecontent offueltheoutputofboilerdecreasesanditsconsumptionincreases)
inthefuelbin
°C
-Thechoiceoftherightboilersize,thatisitsheatingoutput,isaveryimportantconditionfor economicoperationandrightfunctionoftheboiler.Theboilermustbechosensothatits nominaloutputrespondstoheatlossoftheheatedobject.
Theguaranteedoesnotapplyfortheboilerif:
-itisoperatedwithwoodexceeding20%moisturecontentorwithfuelnotprescribedby themanufacturer.
-IfapropermixingapplianceRegumatisnotinstalledinthesystem,whíchprovidesfor returnwaterthetemperatureof65°C.
-afunctionalthermostaticvalve(WATTSSTS20)isnotinstalledonthecoolingcircuit ofboilerandconnectedtothesourceofcoolingwater.
2
Content:
2.Important 3Content 4Introduction,generaldescription 5Technicalparameters 6Dimensionsofboilers 7,8ControlboardofATTACKDPSTANDARD,PROFI 9Purposeofuse,technicalparamaters,operationalrules 10Warning 11TechnicaldescriptionofDPPROFI 12Overheatingoftheboiler,thewaysofregulation,displayingfaults 13Maintenanceofheatingsystem,Prescribedfuel 14Chimney,exhaustpipe,connectingboilertothemains 15Protectionofboileragainstcorrosion 16Recommendedconnection 17Protectionofboileragainstoverheating 18Defectsandtheirremedy 19Possiblefaultsandthemeansoftheirelimination 20Schemeofdependencyofresistanceonthetemperatureofheatingwaterbythe thermalprobe(DPPROFI) 21-22ElectricalschemesofboilerconnectionsATTACKDP
3
Introduction:
Dearcustomer,
Generaldescription:
DescriptionofATTACKDPbrand:
ATTACKDPwoodgasifyingboilerisdesignedforeconomicandecologicalheatingof
familyhouses,bungalows,smallplants,workshopsandsimilarobjects.
Thankyouforconfidencethatyoushowedusbypurchasingourproduct-ATTACKwood gasifyingboiler. Wewishyoulongandreliableoperation.Properattendanceoftheboilerisone oftheconditionsforreliableandrightoperation,sopleasereadthisinstructionforuse carefully.Themanualiswritteninthewaytorespecttherightoperationoftheboilerin centralheatingsystem. Theconditionsofrightoperationoftheboiler:
-tochoosetherighttypeandoutputoftheboiler
-impeccableputtingintooperation
-sensitiveattendance
-regulartechnicalmaintenance
-reliableservice
SpecifiedfuelforATTACKDPboilersisdrywood,e.g.logsoflengths,dependingonthetype ofboiler.Thewoodgasifyingboileristheholderof1015certificate.
ATTACKDP25Standard
35 45
75
ATTACKDP25Profi
35 45
75
Boileroutput
Woodgasifyingboiler
4
Version
Version
Boileroutput
Woodgasifyingboiler
Technicalparameters:
Specifiedmin.temperatureofreturnablewaterinoperationis65°C. Specifiedtemperatureofwaterduringoperationintheboileris80-90°C.
5
TypeofboilerDP75DP25DP35DP45
BoileroutputkW16-2522-3529-4548-75(verziaSTANDARD) OutputrangekW10-2514-3518-4530-75(verziaPROFI) Heatingsurface2,302,703,105,20m
2
Feedhoppercapacitydm105145185350
3
Dimensionoffeedingopenning235x445235x445294x544mm235x445 SpecifiedchimneyPa25252525
Max.workingwateroverpressurekPa250250250250 Boilerweightkg350390420650 Diameterofflueconnectionmm152152152219
Boilerheightmm1080132010801080 Boilerwidthmm580750580580
Boilerdepthmm1050115012651600 ShieldingofelectricpartsIP21212121
ElectricalinputW45454545 Boilerefficiency%86868686
COemisionclass3 Temp.offluegasinnominaloutput°C220220220220 Flowoffluegasinnominaloutputkg/s0,0150,0180,0210,045 Maximumnoiselevel656565dB65 Specifiedfuel Averagefuelconsumption7,510,513,522,5kgh
-1
mm550/580650/680750/7801000/1100 Burningtimeinnominaloutputhod.3333 Watervolumeinboilerl657892160 Min.volumeofequalisationbasinl5006257501500
VoltageV/Hz230/50
Consumptionforseason
1kW=1m
3
°C65-90 °C10-27
V/A230/1,5
Drywoodof15-17Mj/kg-1calorificvalue,watercontent min.12%-max.20%diameter80-150mm
Rangeoftemperature ofheatingwater
Rangeofroomtemperature (PROFIversion)
Currentcarryingcapacity ofboilerregulatorcontacts(PROFIversion)
Max.lengthoflogs/Depthofcombustionchamber
DimensionsofATTACKDPboilers
1.Boilerbody
2.Controlboard
3.Feedingdoor
4.Ashdoor
5.Suckingfan
6.Flue
7.Heatproofshapedpiece-jet
8.Heatproofshapedpiece-ashpan 9Boilerthermostat
10.Reset
11.Fluegasthermostat
12.Controlthermostatofventilator
13.Switch
14.Thermometer
15.Regulatorofoutput
16.Coolingdowncircuitagainstoverheatingofwaterinboiler
17.Coverofcleaninghole
18.C.H.flowconnection
19.
20.Controldoor
21.Pullrodofchimneyflap
C.H.returnconnection
22.Boilerregulator(PROFIversion)
6
ATTACK
®
C.H.flowconnection C.H.returnconnection
1
2
3
4
5
6
7
8
9,10,11,12,13,14,15,22
21151617
18
19
20
17
width
depth
152
G1/2"
80mm/100mm
(DP25,35,45)(DP75)
80
225mm/290mm
(DP25,35,45)(DP75)
DP25DP35DP45DP75
G6/4"G6/4"G2"G2"
G6/4"G6/4"G2"G2"
Controlboard
1.Reset
2.Fuse
3.Mainswitch
4.Fluegasthermostat
5.Boilerthermostat
6.Thermometer
7.Pullrodcontrol
Description:
1.Reset-
2.Fuse-
3.Mainswitch-
4.Fluegasthermostat-
5.Boilerthermostat-
6.Thermometer-
7.Pullrodcontrol-
protectionoftheboileragainstoverheating(incasethetemperatureishigherthan 110degreesC,theboilerisdisconnectedfromthepowernet) protectionoftheboileragainstshortcircuit
switchingonoftheboiler,switchingoffifnecessary
whenthetemperatureoffluegasdecreasesundersetupvalue,the
fanisswitchedoff
servesforsettingupmaximumtemperatureofwaterintheboiler(after exceedingsetuptemperaturethefanisswitchedoffandthe boilerworkswithminimumoutput.Afterdecreasingsetuptemperature thefanisswitchedonagainandtheboilerworkswithmaximum
output.
indicatesoutlettemperatureofwaterfromtheboiler
servesforopeningandclosingoffuelcut-offflap
7
ATTACKDPStandard
Woodgasifyingboiler"ATTACKDPStandard"iscontrolledbyaboilerandfluegasthermostat.
ATTACKDPProfi
TheassetofProfiversionofATTACKDPboilerscomparingwithStandardversionisinmore comfortableserviceandthepossibilityofheatoutputmodulationandadditionofcontrolelements.
Theboilertemperatureiskeptatthelevelsetbytheuser,bysettingupnumberofrevolutionsofthe fluegasfan.ATTACKPROFIboilerregulatormeasuresthetemperatureofwaterintheboiler continuouslyanddepictsitsvalueonthedisplay,controllingthepumpofcentralheatingatthesame time.Thereisapossibilitytoconnectaroomthermostattotheboilerregulator.Theroomthermostat providesthoroughregulationoftemperatureofheatedrooms.Thecontrolofdriveofthefour-way mixingvalveispossibleaswell.
Backwardviewofelectronicregulator:
Settingoffluegas fanspeedduring burningupmode
Settingofpostpurgetimeoffanafterreachingsetuptemperatureofheatingwater
Fuse 2A
Connectingof mixingvalve (12V)
Connectingofroomtemperaturesensororthermostat
8
7-Controllightofcirculatingpumpoperation 8-Controllightoflackoffuel
9-Turningbuttonofroom
thermostat
10-TESTbutton(bypressingthebutton thetemperaturesetupbytheturningbutton6. appearsandatthesametimefluegas fanswitchesoffforamoment)
1-Mainswitch 2-Displayshowingthe
boilertemperature
3-Controllightof
burningupprocess
4-Controllightofboileroverheating 5-Controllightof
roomthermostat
6-Turningbuttonofboiler
thermostat
1 2 3 4 5 6
9 8 7
10
Loading...
+ 16 hidden pages