The accumulation tanks ATTACK HR, HRS are made from the quality steel
and serve for accumulation of the heating water as well as for preparation of
the D.H.W. by an internal enameled exchanger. The ATTACK HRS model is
accessorized with an extra exchanger to be connected to the solar system.
Tanks of this type have a built-in magnesium anode in the D.H.W. tank
to increase resistance against corrosion. The manual deaeration valve is installed in the upper part.
ATTACK HR: 9× socket G 1 ½", 6× socket G ½"
ATTACK HRS: 9× socket G 1 ½", 6× socket G ½", 2× socket G 1" – solar circuit
KEY FOR THE ACCUMULATION TANKS
1 – Flow connection – boiler . . . . . . . . . . . . . 1 ½"
2 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
3 – Electrical heating coil (EL) . . . . . . . . . . . . 1 ½"
4 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
5 – Return connection – heating circuit . . . . . . 1 ½"
6 – Flow connection – heating circuit (radiators) 1 ½"
7 – Flow connection – heating circuit (floor) . . . 1 ½"
8 – Return connection – gas, oil and pellet boiler 1 ½"
9 – Return connection – wood boiler . . . . . . . 1 ½"
10 – Sensor of solar system or heating . . . . . . . ½"
AS – Flow connection of solar system . . . . . . . . 1"
RS – Return connection of solar system . . . . . . . 1"
D1 – Diameter without insulation
D2 – Diameter with insulation
CN – Pump of the circulation tank . . . . . . . . . . ¾"
AF – Cold drinking water . . . . . . . . . . . . . . . . ¾"
AC – Hot drinking water . . . . . . . . . . . . . . . . . ¾"
MA – Magnesium anode . . . . . . . . . . . . . . . . . –
TECHNICAL PARAMETERS
Tank
Solar
excha nger
Internal
tank
Tank
Type
Position 1–6
Position 2–7
Position 3
L-max. length of th e el. heating
body
Position 4–8
Position 5–9
Position RS
Position AS
∅ D1 – Diameter without
insulation
∅ D2 – Diameter with insula -
tion of 100 mm
Height
Height with insulation of
100 mm
R – Slope dimension wit hout
insulation
Max. operating temperature (°C)
Static loss (W )
Max. operating pressure (bar)
Area of exchanger (m²)
Volume of e xchanger (l)
Max. operating pressure (bar)
Volume (l)
Max. operating temperature (°C)
Max. operating pressure (bar)
Volume (l)
Weight (kg)
HR600K
1 515 1 123 794 650 684 245 - - 70 0 900 1 754 1 854 1 841 95 99 3 - - - 160 95 6 445 157
HR800K
1 545 1 135 8 46 735 725 315 - - 790 9 90 1 806 1 906 1 898 95 105 3 - - - 160 95 6 553 157
HR1000K
1 735 1 255 1 036 735 775 295 - - 790 9 90 1 996 2 096 2 081 95 121 3 - - - 160 95 6 731 172
HR1250K
1 655 1 175 988 880 695 285 - - 950 1 150 1 948 2 048 2 064 95 142 3 - - - 160 95 6 1 079 172
HR1500K
1 755 1 345 1 072 920 820 375 - - 1 00 0 1 200 2 032 2 132 2 160 95 161 3 - - - 160 95 6 1 260 265
HR2000K
1 955 1 408 1 314 1 000 862 315 - - 1 100 1 300 2 274 2 374 2 390 95 188 3 - - - 160 95 6 1 800 296
HRS600K
1 515 1 123 794 650 684 245 245 725 700 900 1 754 1 854 1 841 95 99 3 1,8 11,9 10 160 95 6 445 157
HRS80 0K
1 545 1 135 8 46 735 725 315 315 725 790 9 90 1 806 1 906 1 898 95 105 3 2,4 15,9 10 160 95 6 553 157
HRS1000K
1 735 1 255 1 036 735 775 295 295 860 790 9 90 1 996 2 096 2 081 95 121 3 3 19,8 10 160 95 6 731 172
HRS1250K
1 655 1 175 988 880 695 285 285 850 950 1 150 1 948 2 048 2 064 95 142 3 3 19,8 10 160 95 6 1 079 172
HRS1500K
1 755 1 345 1 072 920 820 375 375 895 1 0 00 1 200 2 032 2 132 2 160 95 161 3 3,6 19,8 10 160 95 6 1 260 265
HRS200 0K
1 955 1 408 1 314 1 000 862 315 315 843 1 100 1 300 2 274 2 374 2 390 95 188 3 4,2 23,7 10 160 95 6 1 800 296