AT&T PagePac, PARTNER PagePac Simplified User Manual

Page 1
AT&T
SIMPLIFIED USER GUIDE
PARTNER® PagePac®
OPERATION Accessing the System
1.
2.
3.
4.
1.
2.
3.
1.
2.
3.
] (If a Connect Password is enabled, you will hear a special tone. Enter the Connect Password.) You should hear the PARTNER PagePac dial tone.
Paging
Lift the receiver and access the system (see Accessing the System, above). Dial the zone or zone group code: [ 1 ] for zone 1
[ 4 ] for zones 2 and 3
[ 2 ] for zone 2
[ 5 ] for zones 1 and 3
[ 3 ] for zone 3
[ 6 ] for zones 1 and 2 [ 7 ] for all zones
Make page. Gently replace the receiver.
Talkback
Follow steps 1 and 2 of Paging. Make page or listen to speaker at talkback zone. Gently replace the receiver.
Microphone Page
Turn on the microphone. Make page. Turn off the microphone.
Night Bell
Pick up any ringing phone on line configured for Night Bell
Door Bell
Door Alert Mode: Dial into the system (see Accessing the System, above). Ring Down Mode: Pick up the ringing extension.
Harris Corporation Dracon Division
Door Ajar
Door Alert Mode: Dial into the system (see Accessing the System, above) Enter any touch-tone digit Ring Down Mode: Pick up the ringing extension Dial any touch-tone digit
Door Unlock
Enter Door Unlock Code
Silent Monitor
Follow steps 1 and 2 of Paging. Monitor conversation at Doorspeaker zone. Gently replace the receiver.
PROGRAMMING Selecting System or Zone Options
1.
2.
1.
2.
1.
2.
3.
1.
2.
3.
4.
5.
6.
Lift the receiver and access the system (see Accessing the System, above). Dial [
] [
] (followed by the programming password, if one has been configured). Dial appropriate buttons to change or verify an option (see Programming Options on back). You should hear the Configuration tone (two beeps). For Zone Options only: Dial the zone number. You should hear the Configuration tone. Dial the appropriate value (see Programming Options on back). You should hear the Configuration Complete tone (three beeps). Dial [ # ] to end programming.
Comcode-406980763
CIC 403-248-205
0II726070-001, Issue 1
Page 2
AT&T
PROGRAMMING OPTIONS
SYSTEM PROGRAMMING OPTIONS
SYSTEM OPTION
ACTION
VALUE
Connect Password
[ 3 ][ 0 ] to change; [ 3 ][ 1 ] to verify
Zero to six touch-tone digits; terminated by [ # ] if fewer than six digits specified
Programming
[ 3 ][ 2 ] to change; [ 3 ][ 3 ] to verify
Zero to six touch-tone digits; terminated by [ # ] if
Password
fewer than six digits specified
Door Unlock Code
[ 3 ][ 4 ] to change; [ 3 ][ 5 ] to verify
One to four touch-tone digits; terminated by [ # ] if fewer than six digits specified
Confirmation Tone
[ 4 ][ 0 ] to change; [ 4 ][ 1 ] to verify
[ 0 ] to disable; [ 1 ] to enable
Enabled Pre-Announcement
[ 4 ][ 2 ] to change; [ 4 ][ 3 ] to verify
[ 0 ] to disable; [ 1 ] to enable
Tone Talkback Warning
[ 4 ][ 4 ] to change; [ 4 ][ 5 ] to verify
[ 0 ] to disable; [ 1 ] to enable
Tone Enabled Reset to Factory
[ 1 ][ 0 ] to configure
Defaults
[ 2 ][ 5 ][ 3 ][ 2 ][ 7 ] ([ C ][ L ][ E ][ A ][ R ])
ZONE PROGRAMMING OPTIONS
ZONE OPTION
ACTION
ZONE
VALUE
NUMBER
Type of Zone
[ 6 ][ 0 ] to change; [ 6 ][ 1 ] to verify
[ 1 ] or [ 2 ]
[ 1 ] for Page/Speaker [ 2
] for Doorspeaker
[ 3
] for Remote Amp
Door Action
[ 6 ][ 2 ] to change; [ 6 ][ 3 ] to verify
[ 1 ] or [ 2 ]
[ 1 ] for Door Alert [ 2 ] for Ring Down
Page/Tone Level
[ 6 ][ 4 ] to change; [ 6 ][ 5 ] to verify [ 6
][ 6 ] to change; [ 6 ][ 7 ] to verify
[ 1 ] or [ 2 ]
[ 1 ] through [ 8 ] for Amplifier Level
Music Level
[ 1 ] or [ 2 ]
[ 1 ] through [ 8 ] for Amplifier Level
Station Page Enabled
[ 7 ][ 2 ] to change; [ 7 ][ 3 ] to verify
[ 1 ] , [ 2 ] , or [ 3 ]
[ 0 ] to disable;[ 1 ] to enable
Music Enabled
[ 7 ][ 4 ] to change; [ 7 ][ 5 ] to verify
[ 1 ] , [ 2 ] , or [ 3 ]
[ 0 ] to disable;[ 1 ] to enable
Talkback Enabled
[ 7 ][ 6 ] to change; [ 7 ][ 7 ] to verify
[ 1 ] or [ 2 ]
[ 0 ] to disable;[ 1 ] to enable
Night Bell Enabled
[ 7 ][ 8 ] to change; [ 7 ][ 9 ] to verify
[ 1 ] , [ 2 ] , or [ 3 ]
[ 0 ] to disable;[ 1 ] to enable
Pass DTMF to Zone
[ 9 ][ 0 ] to change; [ 9 ][ 1 ] to verify
[ 1 ] , [ 2 ] , or [ 3 ]
[ 0 ] to disable;[ 1 ] to enable
Enabled Microphone Page
[ 1 ] , [ 2 ] , or [ 3 ]
[ 0 ] to disable;[ 1 ] to enable
[ 9 ][ 2 ] to change; [ 9 ][ 3 ] to verify
Enabled Door Alert Enabled
[ 9 ][ 4 ] to change; [ 9 ][ 5 ] to verify
[ 1 ] , [ 2 ] , or [ 3 ]
[ 0 ] to disable;[ 1 ] to enable
Harris Corporation Dracon Division
0II726070-001, Issue 1
Loading...