Atop Technology EHG2308 User Manual

Techn o lo g ie s
Atop Technologies, Inc.
Industrial DIN-Rail Unmanaged
Gigabit Ethernet Switch
EHG2308
8-port Industrial Unmanaged Gigabit Ethernet Switch
Hardware Installation Guide
Version 1.1
Updated on March, 2011
Introduction
Thank you for purchasing Atop EHG2308 Industrial Unmanaged Gigabit Ethernet Switch. This document intends to provide customers with brief descriptions about the product and to assist our customers to get started using our devices.
Inside the Package
- Main Product
One EHG2308 device
- Standard Accessories
Terminal block for power input
The hardcopy of Hardware Installation Guide
- Optional Accessories
US315-12(US), AC100V~240V 50/60HZ 12V/1.25A, US Plug (optional),
Atop PN:50500151120009G
US315-12(EU), AC100V~240V 50/60HZ 12V/1.25A, EU Plug (optional),
Atop PN:50500151120019G
Wall mount kit, 45.4*22.8mm(thick:1.5mm), Black color (optional),
Atop PN:201GW51CW37004G
Product Description
EHG2308
8-Port Industrial Unmanaged Gigabit Ethernet Switch
8 ports of 10/100/1000Base-TX with RJ45 connector
5 pins Terminal Block type of the power connector
2 LEDs with Power1(P1) and Power2(P2) status
P2P2P1
V+
V- V+ V- F.G.
Hardware Installation
Step1: Installation on “Din-Rail”
EHG2308 switch is equipped with a Din-Rail bracket attached onto the rear panel. Please follow the below steps to fasten the switch to the Din-Rail correctly.
Tip the switch forward and press it against the Din-Rail after align
the bracket springs to the Din-Rail.
Press the bracket against the upper ledge of the Din-Rail until it
clicks.
Notice :
The switches are designed to be mounted on a well-grounded place, such as a metal panel.
Step2: Connecting the Power
Prepare the suitable power source and connect it into the switch by Terminal Blocks (TB5).
DC 9-48V for EHG2308.
You can connect two DC inputs into the switch power if auto-backup is needed.
Check P1/P2 power LED. The LED(s) will be lighted when the device is ready.
Step3: Connecting the Network Devices
Connect your devices using standard UTP/STP cable with RJ-45 connectors to the switch. (For the cable wiring diagrams, please refer to the Pin Assignment)
The corresponding RJ-45 LED will be lighted if the Ethernet connection is linked successfully.
The LED will be blinked during data transfer by the switch.
UL Notice for Power supplier
All the series of products are intended to be supplied by a Listed Power Unit marked with “LPS”, “Limited Power Source” or “Class 2” with output rate 9-48VDC, 0.45A maximum. Or, use the recommended power supplies in “Optional Accessories”.
LED Indicators
There are some LED indicators located at the front panel of the switch.
Name
P1/P2
RJ-45
LED
Green
Green
Yellow
Status
Off
On Off
Blink
Off On
Power input 1/2 is not plugged yet Power status is ready Link is broken, or no cable is plugged in
The device is transferring data through the port
The link is operated at rate of 10/100 Mbps The link is operated at rate of 1000 Mbps
Description
Tel: 886-3-5508137
Fax: 886-3-5508131
www.atop.com.tw
90.6mm
45.4mm
5-pin Terminal Block for Power Input
P1
87
65
43
Pin Signal
Warning:
Before connecting the switch to the DC power input, please make sure
P2 P1
V+
V- V+ V- F.G.
V+ V- F.G.
DC9-48V 0V Frame Ground
the DC voltage supplied by the power source is correct and stable.
21
Configuration and Setting Methods
Any settings or configuration is unnecessary.
Pin Assignment of Network Connections
RJ-45
1 8
PIN
1
2
3
4
5
6
7
8
RJ-45 8-wiring normal definition
Switch PC(NIC)
RJ-45 Plug Pin 1
Straight-Through Cable
3 6 1 2 4 5 7 8
Cabel Wiring
MDI(1000base-T)
TP1+
TP1-
TP2+
TP3+
TP3-
TP2-
TP4+
TP4-
MDI(10/100base-T)
TX+
TX-
RX+
RX-
3 6 1 2 4 5 7 8
Mechanical dimensions(unit=mm)
P2P2P1
V- V+ V- F.G.
V+
P1
87
Front-panel view
90.6
103.2
115.2
65
43
21
45.4
27.2
90.6
Warranty Policy
Warranty Conditions
Products supplied by Atop Technologies are covered in this warranty for sub-standard performance or defective workmanship. The warranty is not, however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts (b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake (c) Use of unqualified power supply, connectors, or maintenance procedure (d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number from Atop before shipping the goods to be repaired to Atop. When in normal use, a sold product shall be replaced with a new one within 3 months after purchase. The shipping cost from the customer to Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to replace the unit with a new one; normally, as long as a product is under warranty, all parts and labor are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and labor.Three months after purchase, the shipping cost from the customer to Atop will not be reimbursed, but the shipping cost from Atop to the customer will be paid by Atop.
Limited Liability
90.6
Atop shall not be held responsible for any consequential losses from using Atop’s product.
The warranty certification will not be effective until an authorized stamp issued by Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd)
Serial Number:
RJ-45 8-wiring Cross-Over definition
Switch Switch
RJ-45 Plug Pin 1
3 6 1 2 4 5 7 8
Cross-Over Cable
Cabel Wiring
Warranty Period
Product Categories
78.7
1 2 3 6 7 8 4 5
32.2
45.4
EHG2308 Front-panel view, Backboard rear view and Housing side view (including the optional mounting kit)
90.3
Housing side view(Mount kit)Backboard rear view
Serial-to-Ethernet Server Serial-to WLAN Server Industrial Wireless Ethernet Device Modbus Gateway Series Industrial Ethernet Switch Embedded Serial Server Pick-to-Light System Auto-Identification and Data Collection-AIDC
Warranty coverage for accessories such as power adapters
Warranty
5 Years
1 Year
ATOP Customer Services and Supports
1. Please contact your local dealers or Atop Technical Support Center at the following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Web Sitewww.atop.com.tw, e-mailservice@atop.com.tw
Web Sitewww.atop.com.cn, e-mailservice@atop.com.cn
and high-gain antenna is one year.
Any change by website in material announcement primarily. ─
Loading...