ATOP Technologies SE5901B AF User Manual

Industrial Cellular Serial Device Server
Industrial Cellular Modbus Gateway
Industrial Cellular Modbus Concentrator
Industrial Cellular Protocol Gateway
SE5901B/MB5901B/PG5901B Series
Version V1.2
Updated in December, 2018
89900500G
Industrial 3G/4G Serial Gateway x 1 or
Industrial 3G/4G Modbus Gateway x 1 or Industrial 3G/4G Modbus Concentrator x 1 or Industrial 3G/4G Protocol Gateway x 1
3-Pin 5.08mm Lockable Terminal Block
(Already mounted to the device) x 1
2x7 Pin 3.5mm Lockable Terminal Block (IO version only) x 1 DIN-Rail Kit (Already mounted to the device) x 1 Installation Guide with Warranty Card x 1
Never install or work on electrical or cabling during periods of lightning activity. Never connect or disconnect power when hazardous gases are present.
Warning:Hot Surface Do Not Touch. This equipment should be installed indoor and not connect directly
IndoorIndoor
with equipment installed outdoor.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that maycause undesired operation.
Notice: Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not nstalled and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help. The antenna(s) used for this transmitter must not be co-located of operating in
conjunction with any other antenna or transmitter. This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment. Ln order to avoid the possibility of exceeding the Fcc radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8inches) during normal operation.
3G DB9 Type
1~4
4G DB9 Type
1~4
5
11
12
13
14
1. PWR LED
2. RUN LED
3. COM1 Tx LED
4. COM1 Rx LED
5. 9-Pin Male D-Sub Connector for RS-232/485
6. 14-Pin 3.5 mm Terminal Block for RS-232/485(COM1), RS-232(COM2), Relay, and DI
TOP View Bottom View
3 4
1
2
5
6
Front View
5
11
12
13
7. Relay2 LED
8. Relay1 LED
9. DI2 LED
10. DI1 LED
11. Default Button
12. PWR USB
13. 10/100/1000 BASE-T(X) Ports
14. SMA Connector for Antenna (D3G version only)
1. Grounding Screw
2. SMA Connector for Antenna (4G version only)
3. Frame Ground
4. Terminal for Power
5. USB2
6. PWR Reset
7
7. SMA Connector for Antenna (4G version only)
3G IO Type
1~4
6
7~10 11
12
13
14
4G IO Type
1~4
6
7~10 11
12
13
ground the device properly
3. Proceed then to fix the antennas to the female RP-SMA connectors deemed to (Fig. 3). You can then choose whether to plug in the I/O ports at this point or do it later depending on the actual location of the device or level of comfort for performing such operation.
4
5
5.
The device's
3
1
2
4
1
2
5
9-Pin Male D-Sub Connector for RS-232/485
– –
– –
– –
2 x 7-pin Male Terminal Block for RS-232/485(COM 1), RS-232(COM 2) Relay and DI
1 2 3 4 5 6 7
8 9 10 11 12 13 14
1 2 3 4 5 6 7
Assignment
DI1
DI2 RY1c RY1+ RY2c RY2+
SG
Assignment
8
9 10 Tx1/D+ 11 12 13 14
Rx1
CTS
RTS/D-
SG Rx2 Tx2
Relay Output with current carrying capacity of 1A@30 VDC (Normal open)
COM-TX
COM-RX
Green
Green
Orange
(Speed)
LAN
Green (Data)
Power Green
RUN
Green
Blinking
Off
Blinking
Off On
Blinking
slowly
Off
Blinking
Off On Off
Blinking
On/Off
COM port is transmitting data COM port is not transmitting data COM port is receiving data COM port is not receiving data Ethernet is transmitting at 1Gbps
Ethernet is transmitting at 100Mbps
Ethernet is transmitting at 10Mbps Ethernet data is transmitting Ethernet no data transmit Power is being supplied Power is not supplied AP Firmware is running normally System is not ready or halt
SE/MB/PG5901B
-D3G
32
SE/MB/PG5901B
Side View
-4G
Front View
SE/MB/PG5901B
-IO-D3G
Warranty Policy
Warranty Conditions
Products supplied by Atop Technologies are covered in this warranty for
SE/MB/PG5901B
-IO-4G
Bottom ViewTop View
Rear View
18,5
sub-standard performance or defective workmanship. The warranty is not, however, extended to goods damaged in the following circumstances: (a) Excessive forces or impacts (b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake (c) Use of unqualified power supply, connectors, or unauthorized parts/kits (d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number from Atop before shipping the goods to be repaired to Atop. When in normal use, a sold product shall be replaced with a new one within 3 months after purchase. The shipping cost from the customer to Atop will be reimbursed by Atop. After 3 months and still within the warranty period, it is up to Atop whether to replace the unit with a new one; normally, as long as a product is under warranty, all parts and labor are free of charge to the customers. After the warranty period, the customer shall cover the cost for parts and labor.Three months after purchase, the shipping cost from the customer to Atop will not be reimbursed, but the shipping cost from Atop to the customer will be paid by Atop.
Limited Liability
Atop shall not be held responsible for any consequential losses from using Atop’s product.
Warranty Period
Product CategoriesWarranty WarrantyProduct Categories
Ethernet Switches Wireless Serial Device Servers Modbus Gateways Protocol Gateways Media Converters Embedded Device Servers
The warranty certification will not be effective until an authorized stamp issued by Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd) Serial Number
5 Years
DIN-Rail Power Supplies 3 years
Power Adaptors
Antennas
Other Accessories
1 years
Pin Assignments and Connections
10/100/1000BASE-T(X) Ethernet Pinout
10/100Base-T(X)
1000Base-T(X)
134,6
107
12,5
48,3
121,5
122,6
90
31,5
1. Please contact your local dealers or Atop Technical Support Center at the following numbers. + 886-3-550-8137 (Atop Taiwan) + 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account Web Sitewww.atop.com.tw, e-mailservice@atop.com.tw Web Sitewww.atop.com.cn, e-mailservice@atop.com.cn
3. Company Addr: 2F, No. 146, Sec. 1, Tung-Hsing Rd., Jubei, Hsinchu 30261, Taiwan, R.O.C. Manufacturer Addr: 1st FL 30 R&D RD II,SCIENCE-BASED INDUSTRIAL PARK,HSINCHU 300 TAIWAN, R.O.C
─ Any changes to this material will be announced on Atop website. ─
Atop Customer Services and Supports