Contents of this Operation and maintenance handbook are property of ATMOS Chrást company. This handbook is altered
and updated regularly for each production series and it may not be copied without written permission.
The producer does not assume responsibility for errors occurring from this translation.
This Handbook contains all information necessary for routine operation and maintenance of the machine. More detailed
information and procedures for larger repairs are not included in this Handbook but they are available at authorized service
partners of ATMOS Chrást company.
There may appear minor inconsistencies between the Handbook and the actual machine due to improvements of the
machine. Ask your dealer if you have any questions or problems.
The machine design complies with relevant EU regulations. This CE Declaration of conformity is losing its validity in case of
any not-approved modification of individual machine parts and components.
All parts, accessories, piping, hoses and connections through which the compressed air flows should be
∙ of guaranteed quality and approved by the manufacturer for intended use,
∙ approved for the nominal pressure level at least equal to machine maximum operation pressure,
∙ usable in contact with compressor oil and coolant,
∙ delivered together with the Handbook for installation and safe operation of the machine.
You will be provided with all details concerning suitability of individual parts use by selling and servicing centres of ATMOS
Chrást company.
The use of other than original spare parts, fluids and lubricants given in ATMOS Spare Parts Catalogue could lead to the
situation, for which ATMOS Chrást company cannot bear any responsibility. In such a case ATMOS Chrást company does
not take any responsibility for potential damage.
Read the Handbook carefully before operating the machine to fully understand its operation and maintenance requirements.
Guarantee the Operation and maintenance handbook is always at disposal directly by the machine.
Guarantee the maintenance personnel are always professionally trained and acquainted with instructions for operation and
maintenance.
Make sure the operating personnel is acquainted with all safety signs and instructions for machine operation before putting it
into operation or under maintenance.
Make sure all protective covers are installed and shut before putting the machine into operation.
A weekly visual check must be made on all fasteners/fixing screws securing mechanical parts. Notably, safety-related parts
such as a coupling hitch, drawbar components, road-wheels, and a lifting bail should be checked for absolute security.
All components which are loose, damaged or out of order must be repaired without delay.
GUARANTEE CONDITIONS
The manufacturer or its authorized service centre provides all guarantee and after-guarantee service.
If necessary, please contact the manufacturer or its authorized service centre where you will be provided with all necessary
information and recommendations.
Guarantee does not cover
∙
damage caused by incompetent operation and maintenance carried out in contrast with instructions in the Operation
and Maintenance Handbook,
∙ damage caused by incompetent transport, manipulation (car accident) and storage,
∙ damage caused by the machine operation in extremely aggressive surroundings,
∙ consumable materials (filter and separator inserts, V-belts, etc.),
At 2020/N
X.11.2016
4
∙ air end damage caused by corrosion or oil degradation influenced by omission of required inspections.
Guarantee is void
∙ if filter inserts, separator inserts and other materials have not been replaced in intervals prescribed in the Handbook,
∙ if the machine has been used for other purposes than those defined in the Handbook,
∙ if damage has been caused by improper location of the machine in relation to cooling air supply and drain,
∙ if other than prescribed fuels and oils have been used,
∙ if other than original spare parts have been used,
∙ if seals have been damaged,
∙
if the Service Booklet of the machine has not been presented to service engineers during a guarantee inspection or if
prescribed operations have not been logged to the Handbook,
∙ if the machine breakdown has not been caused by a defect due to workmanship,
∙ if there has been and intervention carried out on the machine construction,
∙ if the machine has been repaired by other subjects than the manufacturer or its authorised service centre,
∙
if the machine has been handed over another owner without a technical inspection carried out by the manufacturer or
its authorised service centre,
∙
if prescribed guarantee inspections have not been carried out on time and have not been logged to this Service Booklet
with a coupon sent to the manufacturer,
∙ if a claim has not been lodged in writing at the latest on the 10th day following the day a defect occurred,
∙ if damage has been caused by a third person because of insufficient safety precautions,
∙
if the machine has not been put into operation, operating personnel have not been trained by the manufacturer’s
authorized service centre and this has not been logged to the Service Booklet,
∙ if the registration card has not been filled in.
Do notstandon cocksandotherpartsofthepressuresystem!
Attention!
Do notoperatethecompressor whiledoor or coversareopen!
Attention!
Do notopen theoutputcockbeforeair hosesareconnected!
Attention!
Hotgases!
Attention!
Pressure!
DIESEL
Fuel tanking
Třída/Class
APICH–4-
ACEAE5
Motor oilfilling
VDL 46
Compressoroil fillingCoolantfilling
LiftingpointAnchoringpoint
THIS TYPE OF MACHINE IS INTENDED FOR OUTSIDE OF EU EXPORT ONLY.
7At 2020/N
X.11.2016
TECHNICAL PARAMETERS
CompressorPDK 33-7PDK 33-10PDK 33-12
Air endB 100
–1
Nominal capacity[m
Nominal overpressure[bar]7,010,012,0
Safety valve setting[bar]10,012,514,5
Ambient temperature[∘C]–10 ÷ 50
Max. outlet temperature[∘C]110
Cooling systemoil injection
Compressor oil filling volume[l]7,27,27,2
Transmission oil filling vol.[l]---
Max. oil system temperature[∘C]110,0110,0110,0
Max. oil system overpressure[bar]8,611,613,5
3
· min
]5,03,83,2
Outlet cocks2x G 3/4“
(KAG3/4“)
2x G 3/4“
(KAG3/4“)
EnginePDK 33
Type/ModelKubota V1505-T
Cylinders4
Load speed[min–1]3000
Idle speed[min–1]1500 ± 50
Oil filling vol.[l]6,7
Fuel tank vol.[l]70,0
Coolant filling vol.[l]4,0
Battery[V / Ah]12 / 44
Noise emissionsPDK 33
Sound power level L
WA
Sound pressure level L
pA
[dB(A)/pW]98
[dB(A)/20
𝜇Pa
]
78
Undercarriage (braked/unbraked)PDK 33
2x G 3/4“
(KAG3/4“)
Type/ModelKnott
Max. transport velocity*[km/h]80
Total mass[kg]750
Max. mass on axle[kg]750
Max. mass on suspension[kg]75
At 2020/N
8
X.11.2016
* Recommended transport velocityPDK 33
Max. design velocity[km/h]80
Common roads[km/h]80
Gravel roads[km/h]50
Dirty tracks, etc.[km/h]30
Ground[km/h]10
Wheels and tyresPDK 33
Wheel discs4.5J x 13 - 100x4
Tyres155 R13 (155/80 R13)
Tyre pressure[kPa/bar]250 / 2.5
SAFETY SYSTEM
Consists of:
∙ low engine oil pressure switch,
∙ high air end discharge temperature switch,
∙ high engine coolant temperature switch,
∙ alternator / drive belt failure circuit.
Low engine oil pressure switch
At three month intervals, test the engine oil pressure switch circuit as follows:
∙ Start the machine.
∙ Run the machine at idle speed.
∙
Disconnect the switch connector. Short-circuit contacts in the connector. The machine should shut down (after 2
second delay).
At twelve month intervals, test the engine oil pressure switch circuit as follows:
∙ Remove the switch from the machine.
∙ Connect the switch to an independent low pressure supply (either air or oil).
∙ The switch should be switch offat 1.0 bar.
∙ Reinstall the switch.
Temperature switch(es)
At three month intervals, test the temperature switch circuit(s) as follows:
∙ Start the machine.
∙ Run the machine at idle speed.
∙
Disconnect the switch connectors one by one. Short-circuit contacts in the connector. The machine should shut down
(after 2 second delay).
∙ Reconnect the switches.
High air end discharge temperature switch(es)
At twelve month intervals, test the air end discharge temperature switch(es) by removing it (them) from the machine and
immersing in a bath of heated oil. The switch should be switch offat 110 ± 5∘C. Reinstall the switch(es).
High engine coolant temperature switch
At twelve month intervals, test the engine coolant temperature switch removing it from the machine and immersing in a bath
of heated oil. The switch should be switch offat 110 ± 3∘C Reinstall the switch.
9At 2020/N
X.11.2016
Alternator / drive belt failure circuit
Test the circuit before each machine start as follows:
1. Turn the key to ON position and check that the recharge indicator is on.
2. Complete the machine starting sequence.
3. The recharge indicator should switch off.
At 2020/N
X.11.2016
10
FUNCTIONAL DIAGRAM
Explanatory
notes
1air outlet6air end
2nozzle / min. pres. valve7engine
3manometer8oil cooler
4separator tank9oil filter
5safety valve10thermostat
oil
air
11At 2020/N
X.11.2016
DESCRIPTION OF THE WORKSTATION(S)
Does not apply.
At 2020/N
X.11.2016
12
DESCRIPTION OF THE INTENDED USE
Compressed air can be dangerous when used improperly! Before any operation, maintenance or machine repairs - the
pressure system should be completely empty (free from over-pressure). Besides this, the machine shall be secured against
accidental starting.
Guarantee the machine will be operated on nominal pressure only and the compressor operating personnel are acquainted
with this instruction. Pressure level of compressed air equipment connected to the machine must be at least the same as the
machine nominal pressure level.
Warning
Under no circumstances compressed air is allowed to be used for direct human respiration!
Warning
Compressed air can cause serious injury or death. Relieve overpressure before removing filler plugs/caps, fittings or covers.
Warning
Residual air pressure in the air system can cause serious injury or death. Always carefully vent the air supply
line to tools or cocks before any maintenance.
Output air contains a small amount of compressor oil. For this reason it is necessary to verify the compatibility of all used
equipment connected to the compressed air source.
If compressed air flows into the closed space, it is necessary to provide cooling of the air.
All personnel should always wear proper protective clothes when working with compressed air.
All pressure loaded parts including the pressure hoses should be tested regularly. No signs of damage should be observed
and all parts should be used in conformance with instructions for their use and/or for their intended purpose.
Avoid contact with compressed air.
The safety valve on the oil separator should be tested regularly according to given instructions.
When the machine is stopped, compressed air can flow back into the compressor system from devices or systems
downstream of the machine, unless the service valve is closed. Install a back pressure valve at the machine outlet cocks to
avoid reverse flow in the event of an unexpected shut-down when the outlet cocks are open.
Disconnected air hoses whip and can cause serious injury or death. Always attach a safety flow restrictor to each hose
according to safety rules.
The supposed ways of the machine use are presented below. If the machine should be used in an unusual way or in an
unusual surroundings, please contact the manufacturer.
This machine has been designed and supplied for use under following conditions only:
∙ compressing the usual air that does not contain any additional gases, vapours or additives,
∙ the machine will be operated at temperatures shown in chapter Technical parameters on page 6 ,
∙ the machine will be operated in conformance with this Operation and maintenance handbook.,
∙ the generator will be operated up to nominal current and voltage (when the machine is equipped with a generator).
13At 2020/N
X.11.2016
WARNINGS CONCERNING WAYS IN WHICH THE MACHINERY MUST NOT BE
USED
Due to machine design it is not possible to use the machine at locations where danger of explosion exists. If the machine is
to be operated in such places, all local rules, standards and regulations must be fulfilled by adding of suitable supplementary
devices, such as gas detectors, combustion products removal, safety valves, etc. to eliminate all risks.
Warning
Air discharged from this machine may contain carbon monoxide or other contaminants which will cause serious
injury or death. Do not breathe this air.
The machine produces loud noise with its doors open or a service valve vented. Extended exposure to loud noise can cause
hearing loss. Always wear hearing protectors when the doors are open or the service valve is vented.
Warning
Never inspect or service the machine without previous disconnection of battery cables to prevent accidental
starting of the machine.
Do not use petroleum products (solvents or fuels) under high pressure as this can penetrate the skin and result in serious
illness. Wear eye protection while cleaning the machine with compressed air to prevent eye injury.
Rotating fan blades can cause serious injury. Do not operate the machine without a fan guard installed.
Avoid contact with hot surfaces (an engine exhaust manifold and pipping, an air receiver and air discharge pipping, etc.).
Never use volatile substances (e. g. ether) as a starting aid.
Never operate the machine with guards, covers or screens removed. Keep hands, hair, clothing, tools, etc. away from
moving parts.
The machine is not allowed to be used :
∙ as a direct supply of pressurized air for respiration purposes,
∙ for indirect human consumption without suitable air filtration and purity check,
∙ out of temperature range specified in the general information section of this handbook,
∙ in surroundings containing explosive gases or vapours,
∙ in areas with no reliable device for combustion products removal,
∙ with accessories, components, lubricants and coolants not recommended by ATMOS Chrást company,
∙ for operation with not functional safety or control elements of without these elements.
At 2020/N
X.11.2016
14
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.