AC Characteristics for Read Operation
AT27C256R
-45 -55 -70 -90 -12
-15
Symbol Parameter Condition
Min Max Min Max Min Max Min Max Min Max Min Max
Units
t
ACC
(3)
Address to
Output Delay
CE = OE
= V
IL
45 55 70 90 120 150 ns
t
CE
(2)
CE to Output Delay OE = V
IL
45 55 70 90 120 150 ns
t
OE
(2, 3)
OE to Output Delay CE = V
IL
20 25 30 30 35 40 ns
t
DF
(4, 5)
OE or CE High to
Output Float, wh ic he ve r occ urred first
20 20 25 25 30 35 ns
t
OH
Output Hold from
Address, CE or OE,
whichever occurred firs t
777000 ns
Notes: 2, 3, 4, 5. - see AC Waveforms for Read Operation.
DC and AC Operating Conditions f or Read Operation
AT27C256R
-45 -55 -70
-90 -12
-15
Operating
Temp. (Case)
Com. 0°C - 70°C 0°C - 70°C 0°C - 70°C 0°C - 70°C 0°C - 70°C 0°C - 70°C
Ind. -40°C - 85°C -40°C - 85°C -40°C - 85°C -40°C - 85°C -40°C - 85°C -40°C - 85°C
V
CC
Supply 5V ± 10% 5V ± 10% 5V ± 10% 5V ± 10% 5V ± 10% 5V ± 10%
DC and Operating Characte ristics for Read Operation
Symbol Parameter Condition Min Max Units
I
LI
Input Load Current VIN = 0V to V
CC
±1 µA
I
LO
Output Leakage Current V
OUT
= 0V to V
CC
±5 µA
I
PP1
(2)
VPP
(1)
Read/Standby Current VPP = V
CC
10 µA
I
SB
VCC
(1)
Standby Current
I
SB1
(CMOS), CE = VCC ± 0.3V
100 µA
I
SB2
(TTL), CE = 2.0 to V
CC
+ 0.5V
1mA
I
CC
VCC Active Current
f = 5 MHz, I
OUT
= 0 mA,
CE = V
IL
20 mA
V
IL
Input Low Voltage -0.6 0.8 V
V
IH
Input High Voltage 2.0 VCC + 0.5 V
V
OL
Output Low Voltage IOL = 2.1 mA 0.4 V
V
OH
Output High Voltage IOH = -400 µA 2.4 V
Notes: 1. VCC must be applied simultaneou sl y or before VPP,
and removed simultaneously or aft er V
PP
.
2. V
PP
may be connected directly to VCC, except during program-
ming. The supp ly current would then be th e su m of I
CC
and IPP.
3-128 AT27C256R