The Atlona AT-VTP-550-BL and AT-VTP-550-WH are 5.5” touch panels in black and white,
respectively, for the Atlona Velocity™ Control System. They feature contemporary, rened styling
for modern presentation environments with 720x1280 native resolution, and a capacitive glass
surface that supports multi-touch and gesture interactions. These touch panels conveniently
install into a wall or furniture via a US or Euro one-gang opening. The VTP-550-BL and VTP-550WH feature Power over Ethernet (PoE), enabling a single network connection for data and power.
Setting up the touch panels is eortless as the AV control GUI is automatically uploaded from the
Velocity Control Gateway processor during system conguration.
Package Contents
1 x AT-VTP-550
1 x Metal mounting plate
4 x Mounting screws
1 x Installation Guide
Operating Notes
• The Velocity 5” Touch Panel (AT-VTP-550) must be on the same network as the Velocity
Gateway (AT-VGW-250) or it will be unable to sync for control.
• The AT-VTP-550 is PoE capable, to power the unit, simply plug it into a 802.3at compatible
network switch. If the network switch is not PoE capable, a PoE injector (purchased separately)
can be used.
IMPORTANT: Velocity Gateway (AT-VGW-250) must be set up before the AT-VTP-550 is
fully functional.
1
Installation Guide
AT-VTP-550
Mounting Instructions
The AT-VTP-550 can be mounted to a 1 gang back plate.
1 Select the type of 1 gang back box to use and install into a wall.
NOTE: Install using the region’s safety guidelines for electrical boxes.
2 Thread the Ethernet cable through the 1 gang box.
3 Install the included mounting plate into the 1 gang box.
a If using a UK back box, place the screws in the two inside mounting holes.
b If using a US back box, place the screws through the outside screw holes.
4 Loosen or remove the two screws located at the top and bottom of the unit.
5 Place the unit onto the metal back plate, the dual prongs inserting into the small opening on
the back of the unit.
6 Tighten/attach the screws at the top and bottom of the touch pad.
NOTE: To avoid damage to the unit, do not overtighten the screws.
802.3af compliant
LAN / PoE
Designedin the USA
Manufactured in Taiwan
24V DC / 0.5A
2
Installation Guide
AT-VTP-550
802.3af compliant
LAN / PoE
D
Manufactured in Taiwan
esignedin the USA
24V DC / 0.5A
Installation and Set Up
NOTE: Installation of the Velocity Touch Panel can only be done after the VGW-250
has been set up. View the AT-VGW-250 Installation Guide and Velocity Manual for
instructions.
1 Connect the Ethernet cable into the back of the unit.
a If the Ethernet cable is connected to a non PoE switch, use a PoE injector using 802.3at
(purchased separately).
2 Secure the unit in either the wall or optional stand, as explained in the mounting instructions.
3 The Velocity logo will display during the booting process and will go directly into setup.
Press CONTINUE to start the setup process.
Initial Setup
You will be guided through the setup process
in the next few screens.
CONTINUE
4 When the unit displays the IP information, press CONTINUE.
a If the touch panel does not display an IP, select the Set Static IP slider.
b Assign the unit a static IP. Ensure there are no other devices on the network with the
same IP to avoid connection issues.
3
Installation Guide
AT-VTP-550
Velocity Device Setup
Set Static IP
Subnet Mask
DNS Server
IP Address
Gateway
10.0.0.123
255.255.255.0
Default
10.0.0.1
75.75.75.75
CONTINUE
Velocity Device Setup
Velocity Touch Panel 550
Device Alias
Alt. URL
URL
SCAN FOR GATEWAYS
SAVE & CONTINUEBACK
0.0.0.0
0.0.0.0
5. The unit will load a new screen. Change the Device Alias (if needed) to help dierentiate
when there are multiple touch panels at a site.
6. Press the SCAN FOR GATEWAYS button.
Scanning for Gateways
CANCEL
Scanning for Gateways
10.0.0.234
CANCEL
USE
7 The touch panel will scan for new gateways. Once the correct gateway is found, press USE.
Synchronizing
Waiting for Approval
CANCEL
8 On a network computer, use a browser to log into Velocity.
9 A green message will appear at the top right corner of the screen. Select Buildings.
4
Installation Guide
AT-VTP-550
10 On the buildings screen, press the Synchronize button on the building the touch panel is
located.
11 When the rooms page opens, press the Synchronize button on the touch panel’s room.
12 Press the SAVE & CONTINUE button on the touch panel.
Velocity Device Setup
Velocity Touch Panel 550
Device Alias
13 Depending on the room options there may be multiple buttons on the home page. Select the
any icon to open the room’s control page.
14 Select sources and displays by tapping on them.
a To route sources to displays, drag and drop the source icon onto the display box.
Advanced Settings
Once th touch pad has been set up, the settings can be changed or reset only through the
advanced settings.
1 To access the settings, swipe from the left side of the touch pad to the right.
10.0.0.234
URL
10.0.0.234
URL
SCAN FOR GATEWAYS
SAVE & CONTINUEBACK
NOTE: The room must be completely set up to receive the control interface.
GATEWAY SETTINGS
URL
0.0.0.0
REFRESH PAGE
TOUCH SCREEN SETTINGS
System Volume
Screen Brightness
CLEAN SCREEN
CLOSE
ADVANCED SETUP
ABOUT VELOCITY
2 Select Advanced Setup.
3 Type in the PIN. Default PIN is 554361.
5
Verify your PIN
554361
CANCEL
123
ABC
456
GHIJKLMNO
7809
PQRS
TUVWXYZ
VERIFY
DEF
Installation Guide
ADVANCED SETTINGS
Gateway Settings
URL
Alternate URL
Device Settings
Alias
Touch Screen LAN Configuration
Set Static IP
IP Address
Subnet Mask
Default Gateway
DNS Server
CANCEL
SET PIN
CLEAR CACHE
Within the advanced settings, all the touch pad settings can be changed or reset.
Gateway Settings -
a If the gateway IP is known, it can be typed into the URL eld.
b If the gateway IP is unknown, press the Scan Network button to search for and add
the gateway.
Velocity Touch Panel 550
10.0.0.123
255.255.255.0
75.75.75.75
SAVE
SCAN NETWORK
FACTORY RESET
0.0.0.0
0.0.0.0
10.0.0.1
AT-VTP-550
ADVANCED SETTINGS
Gateway Settings
URL
Alternate URL
Device Settings
Velocity Touch Panel 800
Alias
Changing advanced settings requires
Touch Screen LAN Configuration
application restart.
Set Static IP
IP Address
Subnet Mask
Default Gateway
DNS Server
CANCEL
SCAN NETWORK
SET PIN
CLEAR CACHE
FACTORY RESET
10.0.0.123
255.255.255.0
75.75.75.75
SAVE
0.0.0.0
0.0.0.0
OK
10.0.0.1
ADVANCED SETTINGS
Gateway Settings
URL
Alternate URL
Device Settings
Velocity Touch Panel 800
Alias
Cache has been successfully cleared. Press
Touch Screen LAN Configuration
OK to restart.
Set Static IP
IP Address
Subnet Mask
Default Gateway
DNS Server
CANCEL
SCAN NETWORK
SET PIN
CLEAR CACHE
FACTORY RESET
10.0.0.123
255.255.255.0
75.75.75.75
SAVE
Set Configuration PIN
0.0.0.0
0.0.0.0
OK
10.0.0.1
(Note: Once a pin is set, it will be required to edit settings going
forward)
(Enter a blank pin to remove)
CANCEL
SAVE PIN
12
ABC
456
GHIJKLMNO
7809
PQRS
TUVWXYZ
3
DEF
Device Settings - The touch pad can be renamed for easier syncing with Velocity. Type the
name into the Alias eld.
Touch Screen LAN Conguration - The current IP settings will display in these elds. To
switch to a static IP, select the Set Static IP slider, ll in the IP information, and press Save.
Set PIN - The default PIN of 554361 can be changed to a new pin by pressing the Set PIN
button. Type the new PIN in and press Save PIN.
Clear Cache - Press the Clear Cache button to release the current cache of the VTP. Press
the OK button to verify.
Factory Reset - Press the Factory Reset button to clear all the settings and start the touch
pad set up again. Press the OK button to verify.
6
Connection Diagram
AT-VCC-RS232
AT-VTP-800-WH
Projector
Installation Guide
AT-VTP-550
2
1
ETHERNETHDMI OUTMDP OUT DC 19V
AT-VGW-250
AT-VGW-250
2
(redundancy)
1
ETHERNETHDMI OUTMDP OUT DC 19V
AT-VGW-250
AT-VGW-250
Ethernet / PoE
Ethernet / PoE
AT-VCC
Voltage
Sensor
Contact
Closure
SPDT
DPDT
SPST
Control
AT-VCC-RELAY
AT-VCC
Ethernet
IT Room
Ethernet / PoE
Ethernet
AV LAN
Ethernet / PoE
Ethernet / PoE
AT-VCC-IR
AT-VCC
Display
Control
AT-VTP-550-BL
Ethernet / PoE
Room n + 1
Projector
Screen
Room 1
Ethernet / PoE
AT-VTP-800-BL
AT-VCC-IR
AT-VCC
Troubleshooting
ProblemCauseSolution
My touchpad won’t power
on.
My touchpad isn’t receiving
an IP.
The touchpad is not
connected to a PoE switch.
The connected network is
not DHCP enabled.
• Connect the touchpad to a
• If a PoE switch is not
• Swipe from the left corner
• Set the touchpad to static IP
Display
Control
Room 2
switch that supports 802.3at
PoE.
available, use a PoE injector
(sold separately) to power
the unit.
to the right and press
the refresh button. It can
sometimes take up to 60
seconds to obtain an IP.
by selecting the Set Static IP slider and providing IP,