The Atlona AT-UHD-SW-5000ED is a 5x1 switcher with two HDBaseT™ inputs, three HDMI inputs,
mirrored HDMI and HDBaseT outputs, balanced audio outputs, automatic input selection, and
advanced display control capability. The HDBaseT inputs match perfectly with the HDVS-200-TX
modules to enable VGA and HDMI sources to be easily integrated into a system. The switcher
supports 4K/UHD @ 60 Hz, 4:2:0; (10.2 Gbps). It transmits AV signals along with Ethernet, power,
and control over a single cable to displays up to 328 feet (100 meters) from the switcher. Control
options include automatic input selection, front-panel buttons, and compatibility with IR, RS-232,
or TCP/IP-based control systems. Displays are automatically turned on and off using CEC, IP, or RS-
232. Advanced features also include a web-based GUI for easy set-up and management of EDID,
HDCP, and display control. The switcher offers audio de-embedding of PCM audio over HDMI to
two-channel, balanced +4 dBu analog audio outputs. The switcher is a cost-effective product for
professional integration featuring a compact, 1U, half-rack width enclosure that is easily installed
with included 19” rack-mount brackets. Two units can be mounted side-by-side.
Package Content
• 1 x UHD-SW-5000ED
• 1 x 48V DC power supply (AT-PW48V0.83A-CAPT)
• 4 x Female captive screw connector
(5pin: analog audio, 4 pin: IR, 3 pin: RS-232, and 2 pin: power)
• 1 x Short rack ear
• 1 x Long rack ear
• 2 x Mounting plates
• 1 x Remote control
• 4 x Rubber feet
• 1 x User Manual
Features
• Mirrored HDMI and HDBaseT output
• Two HDBaseT Ethernet enabled PoE compatible input ports
• Automatic display control using TCP/IP/RS-232 commands, or CEC
• Auto input switching with video detection technology (activated through RS-232, TCP/IP, or webGUI)
• Analog audio de-embedding through captive screw connector
• +4 dBu balanced analog audio output
• Control volume using webGUI, IR, TCP/IP, or RS-232
• Supports 4K @ 60Hz 4:2:0 or 4K @ 30Hz RGB with 8 bit color
• Supports Dolby® TrueHD and DTS-HD Master Audio™ when using an HDMI/HDBaseT for audio
input and output
• Extended distance HDBaseT port w/PoE to power compatible receivers up to 100 meters (328 feet)
away
• Ability to switch HDCP reporting between compliant, noncompliant, and auto
• EDID management
• Easy to use webGUI through Ethernet connection
• Half-rack size
• Comes with rack mount ears and mounting plates
atlona.com
3
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Oval holes on the rack ears will
always be attached to the rack.
Rack Ear x 1
Circular holes will always
Larger oval hole will be
attached to the wall/table.
Mounting Plate x 2
Rack Ear x 1
be attached to the unit.
The UHD-SW-5000ED can be mounted in three ways: as a single unit in a rack, with a second unit
in a rack, or against a wall/table using the mounting plates.
Single unit mounting will use the long rack ear and short rack ear to affix the unit to the rack.
Two unit mounting will use two short rack ears (the second will be in the box with the second unit) and two
mountings plates to affix the two units together inside the rack.
Wall/table mounting will use both mounting plates to affix the unit to a table or wall.
Category Cable
For the category cables used in the installation of these products, please be sure to use a 568B
termination as pictured below:
1. White - Orange
2. Orange
3. White - Green
4. Blue
5. White - Blue
6. Green
7. White - Brown
8. Brown
Use the table below to verify the best category cable for the installation.
Performance RatingType of LAN cable
WiringShieldingCAT5e/6CAT6a/7
Solid
Stranded - Patch
cable
(Not recommended)
TerminationPlease use EIA/TIA-568-B termination
Shielded (STP/FTP)
Unshielded (UTP)**N/A
Unshielded (UTP)*N/A
Shielded (STP/FTP)
*******
*N/A
Important! 4K (UHD) signals are sensitive to cable quality and installation technique. It is recommended to use CAT6a/7 solid core cables for best results.
Note: For cable distances see the specifications on page 22
Connector
Connector type and size is very important to ensure extenders work correctly. Please use the
matching cable type with the correct RJ45 connector.
CAT5e cables should use only CAT5e RJ45 connectors
CAT6 cables should use only CAT6 connectors
CAT6a cables should use only CAT6a connectors
CAT7 cables should use only CAT7 connectors
Using the wrong size connectors may result in interference causing loss of signal.
Important! “EZ RJ45 connectors” are not recommended with HDBaseT extenders. Doing so may result in interference
with audio and video transmission.
atlona.com
4
Toll free: 1-877-536-3976
Local: 1-408-962-0515
HDMI 1
HDMI 2
HDMI 3
HDMI 4
HDMI 5
VOLUME
AT-UHD-SW-5000ED
POWER
INPUT
Panel Descriptions
Front Panel
INPUT
5
AT-UHD-SW-5000ED
HDMI 1
HDMI 2
HDMI 3
HDMI 4
HDMI 5
POWER
VOLUME
1
2
3
4
1. HDMI LEDs - Illuminates to indicate the selected source
2. Volume LEDs - Displays the volume level
3. Power Button - Turns switcher on, places the unit in standby mode, or control a connected
display through the HDBaseT output
4. Volume up/down - Adjusts output volume or display volume through the HDBaseT output
5. Input Button - Switches between HDMI inputs
Back Panel
INIROUT
LAN
12345
SS
RS-232
RX TX
INPUT
HDMI OUT
-
L
AUDIO
+ +
4321
R
-
HDBaseT OUT
5
FW
-
DC 48V
+
1. LAN port - Connect network switch or router to this port for Ethernet, TCP/IP, or webGUI control
2. IR port - Connect IR control system or compatible IR emitter/receiver to this port
3. RS-232 port - Connect control system to RS-232 port
4. Audio output - Connect to an amplifier, mixer, DSP, audio receiver, or other audio device
5. FW port: Firmware update port, connect a Mini USB to USB A cable to a computer
6. HDBaseT IN - Connect HDBaseT sources here (e.g. AT-HDVS-200-TX)
7. HDMI IN - Connect sources here
8. HDMI OUT - Connect to an HDMI display, extender, or switcher
9. HDBaseT OUT - Connect to an HDBaseT PoE receiver (e.g. AT-HDVS-150-RX or AT-UHD-EX-100CE-RX)
10. DC 48V: Connect included captive screw, 48V DC power supply here
The captive screw connectors allow you to cut cables to a suitable length, reducing cable clutter
while providing a more reliable connection.
Connecting
When connecting the cables to the female captive screw connector it is important that the wires be
terminated correctly. The female captive screw connector has a contact plate at the top and must
have the wires touching it for signal to pass. When wired correctly (see picture A) the signal will pass,
incorrectly (see picture B) no signal will pass.
A
B
The captive screw connectors have
a contact bar that is adjusted to
compress the wire against the top
contact plate. Use the screws at the
top of the connector to compress
Clockwise
Turn the screws clockwise to
raise the contact bar to the
upper contact plate and hold
the wires in place.
Turn the screws counter
clockwise to lower the
contact bar to release the
wires.
Counter
Clockwise
the wire against the contact plate.
1
2
3
Female captive screw connectors are included: Power (see picture 1),
RS-232 (see picture 2), and IR (see picture 3).
Power
4
Black: - White: +
Note: The IR receiver and IR transmitter is optional for the UHD-SW-5000ED. The compatible IR receiver (AT-IR-CS-RX)
and IR transmitter (AT-IR-CS-TX) can be purchased through atlona.com.
RS-232
- +
IR
The power cable
(picture 4)will have
exposed wires. Each
wire is encased in
a different colored
cover.
5
Pin out color will differ
per RS-232 cable.
RS-232 pin out will be
determined by the RS-232
cable and will connect as
Rx(receiver), Tx(transmitter),
and (ground). (See picture 5)
The wires of the emitter and receiver have been marked to differentiate the pin outs.
The IR emitter (AT-IR-CS-TX sold separately) has two wires: signal and ground. Signal will have a solid
line and ground will be blank. The IR emitter will plug into the IR OUT ports.
There are two wires on the IR captive screw ready cable (AT-LC-CS-IR-2M sold separately): signal and
ground. The signal wire is red and ground wire is black. The IR cable will plug into the IR IN ports
and connect to third party control systems.
atlona.com
S
Signal (S)
Ground ( )
Signal (S)
S
Ground ( )
Toll free: 1-877-536-3976
6
Local: 1-408-962-0515
Analog Audio
A captive screw analog audio connector is provided to ensure a more reliable and secure
connection. The captive screw connector supports balanced and unbalanced audio output.
Balanced audio connections use two signal wires and a ground to minimize interference to audio
signals. Unbalanced audio connections use one signal wire and a ground and are used if other
system components don’t support balanced signals.
XLR
1 ( )
3 ( - )
2 ( + )
Note: Pin outs may vary, please refer to the audio device’s manual to ensure a correct connection.
Important! When terminating cables, please ensure exposed adjacent wires do not touch. This may result in a short
that can damage connected devices.
BALANCEDUNBALANCED
L / R
+
-
+
-
Tip (+)
Sleeve ( Ground)
L / R
+
-
+
RCA
-
Important! With unbalanced connections a jumper is needed between ground and negative to reduce noise
atlona.com
+
-
+
-
++
Toll free: 1-877-536-3976
7
Local: 1-408-962-0515
Ethernet
For convenience, the UHD-SW-5000ED comes with DHCP on. This enables the switcher to be
connected to a network without knowing available IP addresses. If your network does not allow
dynamic IP addresses or if you are using the switcher with a TCP/IP control system, this feature may
be turned off and the IP address set using RS-232 commands or the webGUI.
WebGUI
Atlona has created an easy to use webGUI for initial setup and later changes to the configuration
of the switcher.
To begin, plug a LAN cable into the LAN port of the UHD-SW-5000ED and the network switch,
then type the IP address of the unit into a web browser of a PC connected to the same network (as
seen below).
To find the switcher IP: use RS-232 command “IPCFG”.
Note: IP addresses may also be found using common free IP scanner software such as “Advanced IP
Scanner”
Important:If any stability issues are experienced, disable any anti-virus or firewall that may interfere with network communication to the switcher. Once set up is done and the switcher webGUI is no
longer used, the firewall and anti-virus can be re-enabled.
A login screen will appear (this is the same log in for admin and general users). For the first log in (and future
admin changes) the username is “root” and password is “Atlona”.
Note: Only the admin password can be changed (see page 9). The username will always remain “root”.
atlona.com
8
Toll free: 1-877-536-3976
Local: 1-408-962-0515
The home screen tab
will display the general
system information.
The Network Setup Page will allow the IP information to be changed. When a change is made the
screen will grey and the ability to save or cancel will display at the bottom.
Note: When DHCP is on, the IP address cannot be configured. Turn DHCP off to enable IP configuration.
Note: For a stable connection when using a control system, it is best to set up a static IP. As you select an IP address,
make certain no other devices on your network are using that IP address.
Login Mode has been added to provide a secure telnet login. Once Login Mode has been turned on
a username and password will be required on all IP connections to the switcher.
Note: Login mode should be in off position when the UHD-SW-5000ED is used with control systems that do not
support passwords. If your control system supports password protection, you can turn login mode on. The
webGUI always requires a password.
Note: The username and password used in IP Login Mode will be the same login information as the webGUI.
atlona.com
9
Toll free: 1-877-536-3976
Local: 1-408-962-0515
System Settings
Auto Switch - Turn auto switching on/off. Default is off.
Factory Default - Resets all switcher settings to default
Video Settings
Source - Select one of the five inputs to be routed to the output.
Audio Settings
Volume - Adjust output volume up or down
HDMI Audio Mute - Toggle the HDMI output audio on/off
HDBT Audio Mute - Toggle the HDBT output audio on/off
L/R Audio Mute - Toggle the analog L/R audio output on/off
atlona.com
10
Toll free: 1-877-536-3976
Local: 1-408-962-0515
The Config Page will allow the admin password to be changed, users to be added, and the RS-232
ports to be configured.
Note: User information will display for the admin only. Up to 3 users other than admin can be added.
Note: Only the admin password can be changed. The username will always remain “root”. If the admin password is
lost the system must be returned to factory settings and setup repeated.
atlona.com
11
Toll free: 1-877-536-3976
Local: 1-408-962-0515
The EDID Page enables the input preferred timing to be selected and HDCP compliance reporting
to be set.
Note: To ensure compatibility, it is best to set the EDID to match the native resolution of the connected display and the
audio format of the connected sound system
Note: To use the analog audio output, a 2Ch EDID will need to be selected
Note: Internal EDIDs include audio EDIDs as well. 2Ch is two channel audio, MCh is multi-channel audio (including up
to Dolby TrueHD or DTS-HD Master Audio), DD is Dolby Digital, and DVI does not include audio.
HDCP selection allows the HDCP reporting of the input to be changed between compliant and
non-compliant
Note: This function is controllable through RS-232 and TCP/IP.
Note: UHD-SW-5000ED protects HDCP encoded content and will not pass HDCP content to a non-HDCP compliant
device.
Note: Some devices flag all content as protected when connected to an HDCP compliant display. This prevents what
should be non-protected content from reaching devices (e.g. teleconference system) through the
UHD-SW-5000ED.
Note: When HDCP reports as non-compliant, only user created content is transmitted. Protected content from all
sources (e.g. Blu-ray, AppleTV, etc) is blocked.
EDID Saved
Save the current output’s EDID to memory. There are eight total EDID memories to save to.
atlona.com
12
Toll free: 1-877-536-3976
Local: 1-408-962-0515
The Control Page includes settings which enable display controls by the switcher. It provides a
way to program button functions, turn auto switching on/off, and determine the type of control
commands (TCP/IP or RS-232) sent out.
Button Control Selection
Power - Set which device the power button controls
None: Power button will turn the UHD-SW-5000ED on and off
CEC: Sends CEC command over HDMI and HDBaseT (to the HDMI output of the receiver)RS-232: Power button will send power on/off command over HDBaseT using RS-232 to
compatible receivers and displays
IP: Power button will send power on/off command over Ethernet using either the LAN
connection or the HDBaseT connection
Volume/Mute
Audio Out: Volume buttons will control volume output of the switcher
RS-232: Volume/Mute buttons will send the commands over HDBaseT using RS-232 to
compatible receivers and displays
IP: Volume/Mute buttons will send the commands over Ethernet using either the LAN
connection or the HDBaseT connection
Display Mode - Sets functionality of the power button
DispSW AVon: Display switches on/off, source audio/video signal always on
DispSW AVSW: Display switches on/off, source audio/video signal switches on/off
AV SW: Display is always on, source audio/video signal switches on/off
Always ON: No function
Note: Must be in DispSW AVon or DispSW AVSW for RS-232 display control to work
CEC Control
Power
On - Sends a command over HDBaseT to the HDMI output of the connected receiver to turn
the connected display on
Off - Sends a command over HDBaseT to the HDMI output of the connected receiver to turn
the connected display off
Note: CEC may not work with every display type
atlona.com
13
Toll free: 1-877-536-3976
Local: 1-408-962-0515
System Settings
Display Auto Power On - When enabled, the unit will send a programmed command to the
display to turn on after detecting an A/V signal
Display Auto Power Off - When enabled, the unit will send a command to the display to turn off
after not detecting an A/V signal
Lamp Cool Down Timer (0-300) - Used with a projector whose lamp cannot be turned on for up
to 5 minutes after being shut off. Match settings with lamp delay on projector
Auto Power off timer (10-240) - Sets the period of time between the loss of A/V signal and when
the “Display Off” command is sent
Note: LED will blink red for the auto power off time period then go solid
Note: All functionality remains, only the HDBaseT output is turned off
Display Warm Up Timer (0-300) - Sets the period of time after the display is turned on, that the
power button will be locked
Note: LED will blink green for the warm up timer period and then stay solid
Note: When timers are set to 0 seconds, they will disable the timers’ functions
Control Type - Select whether the display on/off commands are sent using RS-232, TCP/IP, or
CEC
Feedback Verify
On: If receiving no feedback, the product will send the command up to 4 times
Off: The command will only be sent once, whether feedback is received or not
atlona.com
14
Toll free: 1-877-536-3976
Local: 1-408-962-0515
TCP/IP Settings of Controlled Device
This option sets the IP for display control. The static IP set here should match the display’s static IP.
To set or view the display’s IP address, check the display’s user manual.
Note: The switcher and the display must be on the same network for these commands to work
Note: Be sure the static IP address set for the display does not match any other device on the network
IP Mode
Non-login: Does not require a username and password when using TCP/IP to control the
display
Login: Requires a username and password to control the display through TCP/IP
IP Address & Port - Set to match the display’s static IP
Username & Password - Required when in login mode
Save - Saves the IP settings for accessing the controlled device
RS-232/IP Commands
ASCII/Hex - Set which type of commands are sent to the display
On/Off/Volume+/Volume-/Mute - Enter the specific commands and feedback that will be sent/
received when using any of the control options
Note: Individual commands will be found in the display’s manual
End of line symbols - None, CR, LF, CR-LF, Space, STX, ETX, Null - Select the appropriate symbol
from the drop down list. Carriage return, line feed, and carriage return with line feed
are the most commonly used symbols.
Note: Be sure to check the display’s manual for the correct symbol
atlona.com
15
Toll free: 1-877-536-3976
Local: 1-408-962-0515
1
2
4
6
HDVS Page
Input 1 - Set which device the power button controls
Model Name: Displays model number of connected transmitter
IP Link: Displays IP link to compatible transmitter’s webGUI
Input 2 -
1. Displays model number of connected HDVS transmitter
2. Refresh button - Update to ensure the current settings are displayed
3. Input selection - Switch between the HDVS inputs
4. Preferred resolution - Sets the HDVS VGA port preferred input resolution
5. Auto switch - Turns auto switching on/off for the HDVS transmitter
6. Display switch - Sets display switch function of the HDVS (default is AVS)Recommended set to disabled - product will be always on
Output Model Name: Displays model number of connected receiver
IP Link: Displays IP link to compatible receiver’s webGUI
3
5
atlona.com
16
Toll free: 1-877-536-3976
Local: 1-408-962-0515
For the best performance ensure the most current firmware is being used. Atlona frequently
updates firmware to add features, improve compatibility, and fix bugs. If any issues are experienced
with the switcher, check to make sure the most current firmware is installed.
Download the latest firmware from http://www.atlona.com/product/AT-UHD-SW-5000ED to a
specific place on the computer, unzip the firmware file, then update the unit using the browse and
upload buttons.
Click the browse button and select the firmware to be loaded from the PC. Once selected, press
the upload button. The progress bar displays the progress of the firmware update.
The Valens (HDBaseT) port has a separate firmware. This firmware can be found at http://www.
atlona.com/product/AT-UHD-SW-5000ED.
Click the browse button and select the Valens (HDBaseT) file that was downloaded. Once selected,
press the upload button, the progress bar displays the progress of the firmware update.
atlona.com
17
Toll free: 1-877-536-3976
Local: 1-408-962-0515
RS-232 & TCP/IP
Terminal
To set up the RS-232 terminal the first thing needed is to find the RS-232 communications port
under the computer’s device manager. Once there, right click the port and select “Properties”.
Under the properties menu select the port settings tab and set the menu to the switcher default:
Bits per second: 115200, Data bits: 8, Parity: None, Stop bits: 1 and Flow control: None.
A
B
C
Connection
RS-232 is connected through a 9-pin female D connector. Three pins will have specific functions
associated with them, some are unassigned.
5
432
9876
1
No.PinFunction
1----Not used
2TxTransmit
3RxReceive
4----Not used
5GndGround
6----Not used
7----Not used
8----Not used
9----Not used
atlona.com
18
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Commands (TCP/IP and RS-232)
The command codes are case sensitive, do not change capitalization, spacing, or lettering.
CommandFeedbackDescription
PWX
e.g. PWSTA
System sta
HDVS sta
MresetMresetReset device to manufacture default
PWLock X
e.g. PWLock sta
LockLockLocks the front panel buttons
UnlockUnlockUnlocks the front panel buttons
SetOff X
e.g. SetOff 43
x3AVx1x3AVx1Switch inputs Ex. Switch output 1 to input 3= x3AVx1
Statusx2AVx1, x3AVx2Displays what input is connected to the what output
x1$ Xx1$ onTurns on/off output channel (X= on, off, sta)
AutoSW XAutoSW onTurns auto switching on/off (X= on, off, sta)
IRONIRONTurns on the IR receiver window
IROFFIROFFTurns off the IR receiver window
EDIDCopyX memY
e.g. EDIDCopy1 mem2
EDIDMSetX defaultEDIDMSetX defaultSet the EDID of the input to the default EDID
EDIDMSetX saveYEDIDMSetX saveYSet the EDID of an input to the previously saved EDID memory
EDIDMSetX intYEDIDMSetX intYSets the EDID of an input to one of the internal EDIDs
HDCPSetX Y
e.g. HDCPSet1 on
AudioOutX YAudioOutX onTurns the HDMI audio of each output (X= 1, 2) on/off (Y= on, off, sta)
VOUT1 +VOUT1 XXIncreases volume output by 1
VOUT1 -VOUT1 XXDecreases volume output by 1
VOUT1 YY
e.g. VOUT1 -60
VOUT1 staVOUT1 YYDisplays current volume output
VOUTMute1 XVOUTMute1 XMute or unmute the output volume (X= on, off, sta)
PWX
e.g. PWON
Model: AT-UHD-SW-5000ED
MAC Addr: XX-XX-XX-XX-XXXX
Address Type: DHCP
IP: XXX.XXX.XX.XXX
Netmask: 255.255.255.0
Gateway: XXX.XXX.XX.X
HTTP Port: XX
Telnet Port: XX
Firmware: X.X.X
On/Up Time <dd HH:mm:ss>: 04
01:09:32
Power Status: PWON
In 1: AT-HDVS-200TX IP:XXX.
XXX.XX.XX MAC: XX-XX-XX-XXXX-XX
In 2: Null
Out: AT-HDVS-200RX IP:XXX.
XXX.XX.XX MAC: XX-XX-XX-XXXX-XX
PWLock X
e.g. PWLock off
SetOff X
e.g. SetOff 43
EDIDCopyX memY
e.g. EDIDCopy1 mem2
HDCPSetX Y
e.g. HDCPSet1 on
VOUT1 XX
e.g. VOUT1 -60
Turns switcher on, off, or display status
X= ON, OFF, STA
Lock or unlock the power key
X= on, off, sta
Set the time (seconds) before the product goes into standby
X= 0-240, sta
e.g. x2$ off - Turns output 2 off
Save the EDID of output X (1 or 2) to memory Y (1-8)
e.g. Copy EDID of output 2 to memory 5 = EDIDCopy2 mem5
e.g. EDIDMset3 save1 - sets input 3 to EDID memory 1
e.g. EDIDMSet2 int3 - Sets input 3 to internal EDID 3
Set HDCP reporting mode of the HDMI input (X= 1-5)(Y= on, off, sta)
e.g. Input 3 to report HDCP non-compliant = HDCPSet3 off
e.g. Turn Output 2 HDMI audio off = AudioOut2 off
Set volume output to a specific value (XX= -80 to 6)
Each command or feedback is terminated with a carriage return.
Note: If the command fails or is incorrect the feedback is “Command FAILED”
atlona.com
19
Toll free: 1-877-536-3976
Local: 1-408-962-0515
CommandFeedbackDescription
SetCmd x[y]
SetCmd x[y]
Sets the RS-232 or IP command for the selected button or
function x = on, off, vol+, vol-, and mute y = command
e.g. SetCmd on[PWR ON]
SetEnd x[y]
e.g. SetEnd off[CR-LF]
TrigCEC y
e.g. TrigCEC on
TrigRS y
e.g. TrigRS vol+
TrigIP y
e.g. TrigIP vol-
CtlType x
e.g. CtlType rs-232
CliMode x
e.g. CliMode non-login
CliUser x
e.g. CliUser
CliPass x
e.g. CliPass AtlonA
CliIPAddr x
e.g. CliIPAddr sta
CliPort x
e.g. CliPort 24
LampCool X
e.g. LampCool 30
DisWarmUp X
e.g. DisWarmUp 50
AutoPwrMode X
e.g. AutoPwrMode AVSW
PwrKeyMode X
e.g. PwrKeyMode ALWAYSON
ButtonPower X
e.g. ButtonPower IP
ButtonVol X
e.g. ButtonVol sta
e.g. SetCmd on[PWR ON]
SetEnd x[y]
e.g. SetEnd off[CR-LF]
TrigCEC y
e.g. TrigCEC on
TrigRS y
e.g. TrigRS vol+
TrigIP y
e.g. TrigIP vol-
CtlType x
e.g. CtlType rs-232
CliMode x
e.g. CliMode non-login
CliUser x
e.g. CliUser admin
CliPass x
e.g. CliPass AtlonA
CliIPAddr x
e.g. CliIPAddr 192.168.0.23
CliPort x
e.g. CliPort 24
LampCool X
e.g. LampCool 30
DisWarmUp X
e.g. DisWarmUp 50
AutoPwrMode X
e.g. AutoPwrMode AVSW
PwrKeyMode X
e.g. PwrKeyMode ALWAYSON
ButtonPower X
e.g. ButtonPower IP
ButtonVol X
e.g. ButtonVol IP
e.g. Set the on command to send the command PWR ON
Sets the line termination for the chosen command
x = on, off, vol+, vol-, mute, fbkon, fbkoff, fbkmute
y = None, CR, LF, CR-LF, Space, STX, ETX, and null
e.g. Set the command off to have a carriage return and line feed
Triggers the stored CEC command to turn the display on/off
y = on, off
Triggers the RS-232 command from RS-232 or IP
y = on, off, vol+, vol-, and mute
Triggers the IP command from RS-232 or IP
y = on, off, vol+, vol-, and mute
Sets the control type x = ip, rs-232, cec
e.g. Set the control type to RS-232
Sets the control device’s IP mode x = sta, login, non-login
e.g. Sets the IP mode to non-login
Sets the IP username for login x = username, (blank)
e.g. Display the IP username by leaving x blank
Sets the IP password for login x = password, (blank)
e.g. Set the IP password to AtlonaA
Sets the IP address of the controlled device x = ip, sta
e.g. Display the IP address of the controlled device
Sets the IP port of the controlled device x = port, sta
e.g. Set the IP port to 24
Set period of time after the display is turned off that the
power command will not send X= 0-300, sta
Set period of time after the display is turned on that the
power command will not send X= 0-300, sta
Set the display mode for auto power on and off
X= DISPAVON, DISPAVSW, AVSW, ALWAYSON, sta
Set the display mode for the power key
X= DISPAVON, DISPAVSW, AVSW, ALWAYSON, sta
Set what type of command the power buttons sends
X= NONE, RS232, IP, CEC, or sta - NONE will pull up the OSD menu
Set what type of command the volume button sends
X= AUD, RS232, IP, or sta - AUD controls the volume of the unit
FeedbackSW XFeedbackSW XTurns on/off feedback verification X= on, off, sta
Display XDisplay XTriggers display command X= on, off, sta
Baud Rate
Default baud rate to control the switcher is 115200 and default baud rate to control the display or projector
is 9600.Note: For the display’s actual baud rate, refer to the owner’s manual
To change the baud rate of the switcher (for switcher control) or the zone output (for display/projector control),
the commands below will be needed
Switcher parameter command
CSpara[baudrate,data-length,parity,stop-bit] (data-length, parity, and stop-bit for switcher must be 8,0,1)
e.g. To change the baud rate to 38400 use CSpara[38400,8,0,1]
Note: Use this command if the connected control system does not output 115200
Zone output parameter commands (for display control)
RS232para1[baudrate,data-length,parity,stop-bit]
e.g. To change the output baud rate to 19200 use RS232para1[19200,8,0,1]
Note: Use this command if the connected display uses a different baud rate
RS232zone3[command]
Once the switcher and zone output have been set up for the best communication, commands can be sent
to control the display. The commands will come from the user manual of the display or projector. The
commands and any carriage returns/line feeds in the commands will need to be placed in the bracket.
e.g. To turn the display or projector on if the command is PWRON carriage return, use the command:
RS232zone3[PWRON carriage return]
atlona.com
20
Toll free: 1-877-536-3976
Local: 1-408-962-0515
IP Commands
CommandFeedbackDescription
IPCFG
IPQuitIPQuitLogs out of TCP/IP Connection
IPAddUser X Y
e.g. IPAddUser Atlona 1234
IPAddUserusername password
IPDelUser XTCP/IP user was deletedDelete a user from TCP/IP X= username
IPDHCP XIPDHCP XTurns DHCP on or off X= on, off, sta
IPStatic X Y Z
e.g. IPStatic 192.168.1.1
255.255.255.0 192.168.1.200
IPPort XIPPort XSet the TCP/IP Port
IPLogin X
e.g. IPLogin off
Broadcast X
e.g. Broadcast on
IPTimeout XX
e.g. IPTimeout 300
IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port : x
TCP/IP user was addedAdds a user for TCP/IP control
username password
username password
IPStatic X Y Z
e.g. IPStatic 192.168.1.1
255.255.255.0
192.168.1.200
IPLogin X
e.g. IPLogin off
Broadcast X
e.g. Broadcast on
IPTimeout XX
e.g. IPTimeout300
Displays IP address configuration
X= user and Y= Password
Displays a list of users and passwords
Sets static IP address
IPStatic Address(X) Netmask(Y) Gateway(Z)
Enables IP Login
X= on, off, sta
Sets broadcast mode on or off
X= on, off, sta
Determines amount of seconds of inactivity before TCP/IP
disconnects
Each command or feedback is terminated with a carriage return.
Note: If the command fails or is incorrect the feedback is “Command FAILED”
3rd Party Control
The UHD-SW-5000ED is compatible with most 3rd party control systems. TCP/IP and RS-232
commands can be passed from 3rd party control systems to the UHD-SW-5000ED through the LAN
or RS-232 port.
Note: The switcher can also convert TCP/IP commands to RS-232 commands which are then sent to the compatible
HDBaseT devices.
The UHD-SW-5000ED can take either TCP/IP or RS-232 command protocol and transmit it to a
connected device: saving labor, cable, and control system ports.
The RS232zone command re-transmits RS-232 commands to the display through the compatible
HDBaseT receiver. The command may be initiated using either RS-232 or TCP/IP commands.
The Display On/Off command may be used to transmit a TCP/IP command by either RS-232 or TCP/
IP to a display.
CAT5e/6 @ 4K up to 70 meters up to 230 feet
CAT5e/6 @ 1080p up to 100 meters up to 328 feet
CAT6a/7 @ 4K up to 100 meters up to 328 feet
HDMI IN/OUT @ 4K up to 5 meters up to 15 feet
HDMI IN/OUT @ 1080p up to 10 meters up to 30 feet
**4096x2160@50/60Hz & 3840x2160@50/60Hz supported @ chroma subsampling 4:2:0 8-bit only
atlona.com
23
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Safety Information
Safeguards
To reduce the risk of electric shock, do not
expose this product to rain or moisture
If the wall plug does not fit into your local
power socket, hire an electrician to replace
your obsolete socket.
Do not modify the wall plug. Doing so will
void the warranty and safety features.
This equipment should be installed near
the socket outlet and the device should
be easily accessible in the case it requires
disconnection.
Precautions
FCC regulations state that any unauthorized changes or modifications to this equipment, not expressly
approved by the manufacturer, could void the user’s authority to operate this equipment.
Operate this product using only the included external power supply. Use of other power supplies could
impair performance, damage the product, or cause fires.
In the event of an electrostatic discharge this device may automatically turn off. If this occurs, unplug the
device and plug it back in.
Protect and route power cords so they will not be stepped on or pinched by anything placed on or against
them. Be especially careful of plug-ins or cord exit points from this product.
Avoid excessive humidity, sudden temperature changes or temperature extremes.
Keep this product away from wet locations such as bathtubs, sinks, laundries, wet basements, fish tanks,
and swimming pools.
Use only accessories recommended by Atlona to avoid fire, shock, or other hazards.
Unplug the product before cleaning. Use a damp cloth for cleaning and not cleaning fluid or aerosols. Such
products could enter the unit and cause damage, fire, or electric shock. Some substances may also mar the
finish of the product.
Never open, remove unit panels, or make any adjustments not described in this manual. Attempting to
do so could expose you to dangerous electrical shock or other hazards. It may also cause damage to your
product. Opening the product will void the warranty.
Do not attempt to service the unit. Disconnect the product and contact your authorized Atlona reseller or
contact Atlona directly.
atlona.com
24
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Atlona, Inc. (“Atlona”) Limited Product Warranty Policy
Coverage
Atlona warrants its products will substantially perform to their published specifications and will be free from defects in
materials and workmanship under normal use, conditions and service.
Under its Limited Product Warranty, Atlona, at its sole discretion, will either:
A) repair or facilitate the repair of defective products within a reasonable period of time, restore products to their
proper operating condition and return defective products free of any charge for necessary parts, labor and shipping
B) replace and return, free of charge, any defective products with direct replacement or with similar products deemed
by Atlona to perform substantially the same function as the original products
C) refund the pro-rated value based on the remaining term of the warranty period, not to exceed MSRP, in cases
where products are beyond repair and/or no direct or substantially similar replacement products exist.
Repair, replacement or refund of Atlona’s products is the purchaser’s exclusive remedy and Atlona’s liability does not
extend to any other damages, incidental, consequential or otherwise.
This Limited Product Warranty extends to the original end-user purchaser of Atlona’s products and is non-transferrable to
any subsequent purchaser(s) or owner(s) of these products.
Coverage Periods
Atlona’s Limited Product Warranty Period begins on the date of purchase by the end-purchaser. The date contained on
the end-purchaser‘s sales or delivery receipt is the proof purchase date.
Limited Product Warranty Terms – New Products
• 10 years from proof of purchase date for hardware/electronics products purchased on or after June 1, 2013
• 3 years from proof of purchase date for hardware/electronics products purchased before June 1, 2013
• Lifetime Limited Product Warranty for all cable products
• 3 years from proof of purchase date for all Refurbished (B-Stock) hardware and electronic products purchased on or
after June 1, 2013
Remedy
Atlona recommends that end-purchasers contact their authorized Atlona dealer or reseller from whom they purchased
their products. Atlona can also be contacted directly. Visit www.atlona.com for Atlona’s contact information and hours
of operation. Atlona requires that a dated sales or delivery receipt from an authorized dealer, reseller or end-purchaser is
provided before Atlona extends its warranty services. Additionally, a return merchandise authorization (RMA) and/or case
number, is required to be obtained from Atlona in advance of returns.
Atlona requires that products returned are properly packed, preferably in the original carton, for shipping. Cartons not
bearing a return authorization or case number will be refused. Atlona, at its sole discretion, reserves the right to reject
any products received without advanced authorization. Authorizations can be requested by calling 1-877-536-3976 (US
toll free) or 1-408- 962-0515 (US/international) or via Atlona’s website at www.atlona.com.
Exclusions
This Limited Product Warranty excludes:
• Damage, deterioration or malfunction caused by any alteration, modification, improper use, neglect, improper
packing or shipping (such claims must be presented to the carrier), lightning, power surges, or other acts of nature.
• Damage, deterioration or malfunction resulting from the installation or removal of this product from any installation,
any unauthorized tampering with this product, any repairs attempted by anyone unauthorized by Atlona to make
such repairs, or any other cause which does not relate directly to a defect in materials and/or workmanship of this
product.
• Equipment enclosures, cables, power supplies, batteries, LCD displays, and any accessories used in conjunction with
the product(s).
• Products purchased from unauthorized distributors, dealers, resellers, auction websites and similar unauthorized
channels of distribution.
atlona.com
25
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Disclaimers
This Limited Product Warranty does not imply that the electronic components contained within Atlona’s products will
not become obsolete nor does it imply Atlona products or their electronic components will remain compatible with any
other current product, technology or any future products or technologies in which Atlona’s products may be used in
conjunction with. Atlona, at its sole discretion, reserves the right not to extend its warranty offering in instances arising
outside its normal course of business including, but not limited to, damage inflicted to its products from acts of god.
Limitation on Liability
The maximum liability of Atlona under this limited product warranty shall not exceed the original Atlona MSRP for
its products. To the maximum extent permitted by law, Atlona is not responsible for the direct, special, incidental or
consequential damages resulting from any breach of warranty or condition, or under any other legal theory. Some
countries, districts or states do not allow the exclusion or limitation of relief, special, incidental, consequential or indirect
damages, or the limitation of liability to specified amounts, so the above limitations or exclusions may not apply to you.
Exclusive Remedy
To the maximum extent permitted by law, this limited product warranty and the remedies set forth above are exclusive
and in lieu of all other warranties, remedies and conditions, whether oral or written, express or implied. To the maximum
extent permitted by law, Atlona specifically disclaims all implied warranties, including, without limitation, warranties
of merchantability and fitness for a particular purpose. If Atlona cannot lawfully disclaim or exclude implied warranties
under applicable law, then all implied warranties covering its products including warranties of merchantability and fitness
for a particular purpose, shall provide to its products under applicable law. If any product to which this limited warranty
applies is a “Consumer Product” under the Magnuson-Moss Warranty Act (15 U.S.C.A. §2301, ET SEQ.) or other
applicable law, the foregoing disclaimer of implied warranties shall not apply, and all implied warranties on its products,
including warranties of merchantability and fitness for the particular purpose, shall apply as provided under applicable
law.
Other Conditions
Atlona’s Limited Product Warranty offering gives legal rights, and other rights may apply and vary from country to
country or state to state. This limited warranty is void if (i) the label bearing the serial number of products have been
removed or defaced, (ii) products are not purchased from an authorized Atlona dealer or reseller. A comprehensive list of
Atlona’s authorized distributors, dealers and resellers can be found at www.atlona.com.
Atlona Product Registration
Thank you for purchasing this Atlona product. - We hope you enjoy it and will take an extra few moments to
register your new purchase.
Registration creates an ownership record if your product is lost or stolen and helps ensure you’ll receive
notification of performance issues and firmware updates.
At Atlona, we respect and protect your privacy, assuring you that your registration information is completely
secure. Atlona product registration is completely voluntary and failure to register will not diminish your limited
warranty rights.
To register go to: http://www.atlona.com/registration
atlona.com
26
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.