The Atlona OmniStream™ 112 (AT-OMNI-112) is a networked AV encoder with two independent
channels of encoding for two HDMI sources up to 4K/UHD, plus embedded audio and RS-232
control. OmniStream is designed for distributing AV over 1 Gigabit Ethernet in enterprises and
other large-scale installations. The OmniStream 112 features SMPTE VC-2 visually lossless
compression for critical-quality video applications, with extremely low, sub-frame latency from
encode to decode. It also includes selectable AES-128 encryption, and SMPTE 2022-5 forward
error correction for robust AV distribution spanning multiple networks. This dual-channel encoder
is housed in a half-width rack enclosure and is ideal for high-density rack installations. With two
Ethernet ports, the OmniStream 112 can also deliver duplicate AV streams to two networks for
full system redundancy in mission-critical applications.
Package Contents
1 x AT-OMNI-112
1 x Push spring connector, 6-pin
1 x Wall/table mounting brackets
4 x Rubber feet
1 x Installation Guide
Operating Notes
• OmniStream requires the Atlona Management System (AMS) which provides discovery,
management, and conguration assistance. AMS is a free application that can be
downloaded from the Atlona web site at http://atlona.com/product/at-sw-ams/
• OmniStream uses mDNS as the discovery mechanism. In order for mDNS to function
properly, there must not be restrictions applied to the network. VPN can be used to
connect to a computer that is running AMS, on the same network. However, VPN cannot
be used when AMS is running on the local machine.
IMPORTANT: Visit http://www.atlona.com/product/AT-OMNI-112 for the latest rmware
updates and User Manual.
1
Installation Guide
HDMI
PWR
LINK
TM
O
MNISTREAM
VOLUME
DISPLAY
INPUT
ID
1212
Panel Descriptions
12345678
INPUT
PWR
HDMI
1 21 2
LINK
DISPLAY
ID
AT-OMNI-112
MNISTREAM
TM
1
HDMI IN
2
O
AT-OMNI-112
1 PWR
This LED indicator is green when the unit
is powered.
2 HDMI 1 / HDMI 2
These LED indicators show the active
input status.
3 LINK 1 / LINK 2
These LED indicators show the link status
of the encoder.
4 DISPLAY
Press this button to toggle the power state
of the desired display.
5 INPUT
Press this button to switch between HDMI
1 and HDMI 2 inputs.
6 VOLUME
Press these buttons to adjust the output
volume of the desired display.
7 ID
Press this button to identify the unit within
the AMS software.
ETHERNET
VOLUME
TX
RX
1
21
2
RS-232
1110912
8 REBOOT
Use a pointed object to press this
recessed button and reboot the unit.
9 HDMI 1 / HDMI 2
Connect HDMI cables from these ports to
an HD source.
10 ETHERNET 1 / ETHERNET 2
Connect Ethernet cables from these ports
to the Local Area Network (LAN).
11 RS-232 1 / RS-232 2
Use the included captive screw connector
to connect two RS-232 controllers or
automation systems. Refer to RS-232 on
page 3 for more information.
12 DC 48V
Connect the optional 48V DC power
supply to this power receptacle. This
power supply is available, separately.
DC 48V
2
Installation Guide
AT-OMNI-112
RS-232
The AT-OMNI-112 provides RS-232 over IP which allows communication between an automation
system and an RS-232 device. This step is optional.
1. Use wire strippers to remove a portion of the cable jacket.
2. Remove at least 3/16” (5 mm) from the insulation of the RX, TX, and GND wires.
3. Insert the TX, RX, and GND wires into correct terminal on the included push spring
connector, following the wiring diagram below. If using non-tinned stranded wire, press the
orange tab, above the terminal, while inserting the exposed wire.
NOTE: Typical DB9 connectors use pin 2 for TX, pin 3 for RX, and pin 5 for ground.
On some devices, the function of pins 2 and 3 are reversed.
TX
Push tab
to unlock
RX
GND
Installation
1. Connect an Ethernet cable from the ETHERNET 1 and ETHERNET 2 ports on the encoder
to a PoE-capable switch on the Local Area Network (LAN). Note that if a PoE-capable
switch is not available, the 48V DC power supply (sold separately) must be connected to the
encoder.
2. Connect an HDMI cable from each HD/Ultra HD source to the HDMI 1 and HDMI 2 ports on
the encoder.
3. If using RS-232, connect the 6-pin captive screw connector to the RS-232 port on the
encoder.
4. The PWR indicator, on the front panel, display the power status of the encoder. When the
encoder is powered, using either PoE or the optional 48V DC power supply (not included),
the LED initially turns red. After a few moments it will turn amber, and nally green.
INPUT
O
MNISTREAM
PWR
TM
HDMI
1 21 2
LINK
DISPLAY
VOLUME
ID
PWR indicator
3
1
2
HDMIPWR
1
2
LINKDISPLAYINPUTID
VOLUME
AT-OMNI-112
1
2
HDMIPWR
1
2
LINKDISPLAYINPUTID
VOLUME
AT-OMNI-112
1
2
HDMI
1
2
LINKDISPLAYINPUTID
VOLUME
Mounting Instructions
The AT-OMNI-112 encoder includes two
mounting brackets and four mounting screws,
which can be used to attach the unit to any at
surface.
1. Using a small Phillips screwdriver, remove
the two screws from the left side of the
enclosure.
2. Position one of the mounting brackets, as
shown below, aligning the holes on the
side of the enclosure with one set of holes
on the mounting bracket.
3. Use the enclosure screws to secure the
mounting bracket to the enclosure.
Included screws
Installation Guide
5. Repeat steps 1 through 4 to attach the
second mounting bracket to the opposite
side of the unit.
6. Mount the unit using the oval-shaped
holes, on each mounting bracket. If using
a drywall surface, a #6 drywall screw is
recommended.
NOTE: Mounting brackets can
also be inverted to mount the
unit under a table or other at
surface.
PWR
AT-OMNI-112
AT-OMNI-112
4. To provide added stability to the mounting
bracket, use two of the included screws
and attach them to the two holes, directly
below the enclosure screws, as shown
above.
4
Installation Guide
AT-OMNI-112
Conguration
By default, the AT-OMNI-112 is set to DHCP mode. In this mode, each encoder that is
connected to the Local Area Network (LAN) will automatically be assigned an IP address by
the DHCP server, allowing communication with AMS. AMS will only be able to discover the
encoders if they are on the same VLAN. Refer to the User Manual for details on conguring
encoders to static IP mode.
To determine the IP address of the encoder, use the Atlona Management System (AMS) app.
AMS is available only for the Windows® Operating Sytem. If necessary, mDNS/Bonjour can also
be used to discover the IP address of the encoder.
1. Launch the Atlona Management System app.
2. Launch a web browser and enter localhost:8080 in the address eld.
3. Enter the login information on the AMS web page, then click the Login button.
Login: admin
Password: admin123
4. Under the Domain View panel, locate the IP address for the encoder. Encoders will be
labeled as OMNI-112.
Connection Diagram
OmniStream 112
Encoder
HDMI 1 HDMI 2
Video
Eth 1Eth 2
TX
RX
RS-232
DVD Player
Automation
NO
COM
NC
2 3 4
NO
COM
NC
1
NO
COM
NC
Control System
NO
COM
NC
GND
+12V
SIG
GND
+12V
SIG
GND
+12V
SIG
GND
+12V
SIG
ETHERNET
L
DIGITAL
R
COAX OUT
AUDIO OUT AUDIO IN
Control
OR
LAN
COMPONENT
HDMI
VIDEO OUT
SERIAL 1
5
3
6
1
SERIAL 2
4
FACTORY
2
RESET
IR OUT
48V DC
+
DC 48V
2
Control
Ethernet
Ethernet
Video
Laptop
5
Troubleshooting
ProblemSolution
Installation Guide
AT-OMNI-112
PWR indicator is o.• If using a PoE (Power-over-Ethernet) switch, make
LINK indicator is red.• Connect an Ethernet cable to the ETHERNET port(s).
OmniStream encoders are
not displayed in AMS.
sure that the port on the switch that is connected to
the encoder, has PoE enabled. When the encoder is
powered using PoE, the PWR indicator will be green.
• Check the Ethernet cable for possible damage or loose
connections.
• Connect the optional 48V DC power supply (available
from atlona.com) to the encoder. When using an external
power supply, the PWR indicator will be red.
• Check the Ethernet cable for possible damage or loose
connections.
• Verify that AMS and the encoder are on the same
network.
• If a DHCP server is not found within 60 seconds, the
encoder will be placed in Auto IP mode and assigned
an IP address within the range of 169.254.xxx.xxx. If
so, then connect a laptop directly to the encoder and
congure a static IP address for the encoder.
• Check the Ethernet cable for possible damage or loose
connections.
trademarks are the property of their respective owners. Pricing, specications and availability subject to change without notice. Actual products, product images, and
online product images may vary from images shown here.
8
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.