Atlona Technologies AT-OME-EX-RX Installation Guide

Installation Guide
AT-OME-EX-RX
Omega™ 4K/UHD HDMI Over HDBaseT Receiver with USB, Control, and PoE
AT-OME-EX-RX
Package Contents
1 x AT-OME-EX-RX 1 x Captive screw connectors, 4-pin 2 x Mounting plates 2 x Mounting screws 1 x 48 V DC power supply 1 x Installation Guide
IMPORTANT: Visit http://www.atlona.com/product/AT-OME-EX-RX for the
latest rmware updates and User Manual.
* The AT-OME-EX-RX is not compatible with the AT-UHD-HDVS-300 system for extending USB.
1
Installation Guide
HDMI OUTHDBaseT IN
RX TXTX
RS-232 IR
AT-OME-EX-RX
DC 48V
AT-OME-EX-RX
1 3 4
LAN FW
Front
AT-OME-EX-RX
DC 48V
Rear
2
DEVICE
RX TXTX
RS-232 IR
65 7
HDBaseT IN
PWR
LINK
HDMI OUT
OMEGA
8
TM
1 LAN
Connect a category cable from this port to the display (sink) device. This cable provides IP pass-through transport control to the display (sink) device, from a control system connected to the transmitter.
2 DEVICE
3 FW
Connect up to two USB 2.0 devices (e.g. mouse, keyboard, etc.) to these ports. These ports provide 2.5 W per USB device.
Connect a mini USB-to-USB cable from this port, to a computer, to update the rmware.
Refer to Updating the Firmware (page 10) for more information.
4 PWR / LINK
The PWR LED indicator will glow green when the AT-OME-EX-RX is powered. The LINK LED indicator glows yellow when a solid link is established between the transmitter and the AT-OME-EX-RX. Refer to LED Indicators (page 5) for more information.
5 DC 48V
Connect the included 48 V DC power supply to this power receptacle.
6 RS-232 / IR
Connect the included 4-pin captive screw block to this receptacle. Refer to RS-232 and IR
(page 3) for more information.
7 HDBaseT IN
Connect a category cable from this port to the HDBaseT OUT port of the AT-OME-EX-TX or other PoE-compatible transmitter.
8 HDMI OUT
Connect an HDMI cable from this port to the display (sink) device.
2
Installation Guide
AT-OME-EX-RX
RS-232 and IR
The AT-OME-EX-RX provides pass-through transport of RS-232 protocol and/or IR over HDBaseT, which allows communication between a control system and an RS-232 or IR device. This step is optional.
1. Use wire strippers to remove a portion of the cable jacket.
2. Remove at least 3/16” (5 mm) from the insulation of the RX, TX, and GND wires for the RS-232 connection.
3. Insert the TX, RX, and GND wires into correct terminal using one of the included 4-pin captive screw connectors.
4. Repeat step 2 for the S and GND wires for the IR connection.
5. Insert the S (signal) wire in to the TX terminal and the ground wire to the GND terminal.
6. Tighten the captive screws to secure the wires in place. Do not over-tighten or use high-torque devices to prevent damage to the connector block.
NOTE: Typical DB9 connectors use pin 2 for TX, pin 3 for RX, and pin 5 for
ground. On some devices functions of pins 2 and 3 are reversed. Note that the
signal (S) pin for the IR is labeled as “TX” on the port.
TX
RX
GND
DE-9 (RS-232) port
S
GND
to control system
or AT-VCC-IR-KIT
3
Installation Guide
AT-OME-EX-RX
Installation
1. Connect a UHD/HD display to the HDMI OUT port.
2. Connect up to two USB devices (mouse, keyboard, etc.) to the DEVICE ports. These ports provide 2.5 W per USB device.
3. Connect a category cable, from the HDBaseT IN port on the AT-OME-EX-RX, to the HDBaseT OUT port on the transmitter.
4. OPTIONAL: Connect an Ethernet cable from the LAN port on the AT-OME-EX-RX, to the display (sink) device. This cable provide IP pass-through transport control from a control system to the display (sink) device connected to the AT-OME-EX-RX.
5. OPTIONAL: Connect the RS-232 device to the RS-232 port on the AT-OME-EX-RX. Refer to RS-232 and IR (page 3) for more information.
6. OPTIONAL: Connect an IR emitter to the IR port on the transmitter. Connect an IR receiver to the IR port on the AT-OME-EX-RX. Refer to RS-232 and IR (page 3) for more information.
7. Connect the included 48 V DC power supply to the DC 48V power receptacle on the transmitter.
8. Connect the power supply to an available AC outlet.
Cable Recommendation Guidelines
Refer to the tables below for recommended cabling when using Altona products with HDBaseT. The green bars indicate the signal quality when using each type of cable. Higher-quality signals are represented by more bars.
Core Shielding CAT5e CAT 6 CAT6a CAT 7
Solid UTP (unshielded) N/A
STP (shielded)
IMPORTANT: Stranded or patch cables are not recommended due to performance issues.
Cable* Max. Distance @ 4K Max. Distance @ 1080p
CAT5e 295 feet (90 meters) 330 feet (100 meters)
CAT6 / CAT6a / CAT7 330 feet (100 meters) 330 feet (100 meters)
*Atlona recommends TIA/EIA 568-B termination for optimal performance.
4
Installation Guide
LED Indicators
The PWR and LINK LED indicator provide basic information on the current status of the AT­OME-EX-RX.
PWR Description
Solid green AT-OME-EX-RX is powered.
O AT-OME-EX-RX is not powered.
Verify that the locking connector is securely fastened to the power receptacle.
Make sure that the power supply is connected to an active AC outlet.
LINK Description
AT-OME-EX-RX
Solid yellow The link integrity between the transmitter and the AT-OME-EX-
Blinking yellow Poor signal integrity between the transmitter and the AT-OME-
O The link integrity between the transmitter and the AT-OME-EX-
RX is good.
EX-RX.
Make sure that the category cable between the HDBaseT IN port on the transmitter and the HDBaseT OUT port on the AT-OME-EX-RX is secure.
The category cable may be compromised. Try using a
dierent category cable. Make sure that the cable is solid
core. Stranded or patch cables are not recommended.
RX is compromised.
Check the category cable between the HDBaseT IN port on the transmitter and the HDBaseT OUT port on the AT­OME-EX-RX.
5
Installation Guide
AT-OME-EX-RX
Mounting Instructions
The AT-OME-EX-RX provides two mounting brackets, which can be used to attach the AT-OME-
EX-RX to any at surface. Use the two enclosure screws, on the sides of the AT-OME-EX-RX to
attach the mounting brackets.
1. Using a small Phillips screwdriver, remove the two screws from the left side of the enclosure.
TM
OMEGA
PWR
LINK
DEVICE
LAN FW
2. Position one of the mounting brackets, as shown below, aligning the holes on the side of the enclosure with one set of holes on the mounting bracket.
3. Use the screws from Step 1 to attach the mounting bracket.
TM
OMEGA
PWR
LINK
DEVICE
LAN FW
6
Installation Guide
AT-OME-EX-RX
4. Repeat these steps to attach the second mounting bracket to the opposite side of the AT­OME-EX-RX.
5. Mount the AT-OME-EX-RX to a at surface using the oval-shaped holes, on each mounting bracket. If using a drywall surface, a #6 drywall screw is recommended.
TM
OMEGA
PWR
LINK
DEVICE
LAN FW
7
Installation Guide
AT-OME-EX-RX
Analyzer Software
The Analyzer software provides HDBaseT testing, debugging, and rmware update utilities. The software can be downloaded from the Resource tab located at https://atlona.com/product/
at-ome-ex-kit/.
HDBaseT Testing
1. Launch the Analyzer software.
2. Make sure the system is powered and the transmitter and receiver are connected using the HDBaseT OUT and HDBaseT IN ports.
3. Connect an active source to the transmitter and an active display to the receiver. Set the source to the highest resolution.
4. Connect a mini-USB to USB-A cable from the FW port, on the transmitter, to a computer.
5. Click the Port drop-down list and select the COM port, then click the Connect button.
6. Click Quality in the menu bar.
7. Click the Start button in the lower-right right corner of the window. The link information and cable pairing test results will display. Follow the instructions on the Analyzer software for any pair failures.
8
Installation Guide
AT-OME-EX-RX
Debug
1. Launch the Analyzer software.
2. Make sure the system is powered and the transmitter and receiver are connected using the HDBaseT OUT and HDBaseT IN ports.
3. Connect an active source to the transmitter and an active display to the receiver. Set the source to the highest resolution.
4. Connect a mini-USB to USB-A cable from the FW port, on the transmitter, to a computer.
5. Click the Port drop-down list and select the COM port, then click the Connect button
6. Click Debug in the menu bar.
7. Click the Debug button. Information will appear in the box eld if there is any data that can be logged. The log can be saved to the local computer if needed.
9
Installation Guide
AT-OME-EX-RX
Updating the Firmware
Requirements:
AT-OME-EX-RX
Firmware le
Computer running Windows
USB-A to USB mini-B cable
NOTE: The update process can take up to ve minutes to complete.
1. Disconnect power from the AT-OME-EX-RX.
2. Connect a USB-A to USB mini-B cable between the PC and the FW port on the AT-OME­EX-RX.
3. Connect the included power supply to the AT-OME-EX-RX.
4. The USB UPDATE folder will be displayed. If this folder is not displayed, automatically,
select the USB UPDATE drive from Windows Explorer.
5. Delete all les from the USB UPDATE drive, if any are present.
6. Drag-and-drop the rmware le to the drive.
7. The PWR LED indicator, on the front panel, will ash green while the AT-OME-EX-RX is being updated. Do not disconnect the USB cable during the update process. When the
PWR LED stops ashing and is solid green, the update process will be complete.
8. Disconnect the USB cable from the AT-OME-EX-RX.
10
Notes
Installation Guide
AT-OME-EX-RX
11
Installation Guide
AT-OME-EX-RX
Version 2
atlona.com 877.536.3976 41.43.508.4321
Toll free US International
© 2019 Atlona Inc. All rights reserved. “Atlona” and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered
trademarks are the property of their respective owners. Pricing, specications and availability subject to change without notice. Actual products, product images, and
online product images may vary from images shown here.
12
Loading...