![](/html/44/445c/445c9b25acae4055f2ebb911466ae2e0bc3ed8f4420f576faaa3a62e2c05fff9/bg1.png)
Subsidiary of Mercury Aircraft, Inc.
1135 N.W. 159th DR., MIAMI, FL 33169
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: sales@atlasfoodserv.com
PARTS LIST FOR HEATED CONDIMENT RAIL
WCPH
4
1
5
2
3
6
7
ITEM NUMBER PART NUMBER DESCRIPTION
1 1002-0 Power Cord
2 1099-0 Pilot Light
3 1097-0 Dial
4 86-3202 Perforated Snap-In Drain
5 49-1028 Grommet
6 3006-2 3/4 X 4 Brass Nipple
7 3016-1 3/4 Gate Valve
8 111-1040 Heating Element (Not Shown)
9 2040-0 Thermostat (Not Shown)
![](/html/44/445c/445c9b25acae4055f2ebb911466ae2e0bc3ed8f4420f576faaa3a62e2c05fff9/bg2.png)
HEATED CONDIMENT RAIL
WCPH
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
INSTALLATION
Provide a 14 3/4 x 21 7/8 cut-out in the counter top and drop the unit in.
A non-toxic silicone sealer may be used between the flange and counter top (not required).
The unit is supplied with a power cord and a NEMA plug. Refer to the data plate located on the control box for the
amperage and voltage information. Use a licensed electrician when installing power source.
----------------------------------------------------------------------------------------------------------------------------------------------------------------
OPERATION
The unit is ready to operate as soon as it is plugged in. The thermostat has an off position and numbers from 1
through 10 (number 10 is the highest).
----------------------------------------------------------------------------------------------------------------------------------------------------------------
MAINTENANCE
NEVER CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER CLEANING
COULD SCAR, MARK AND/OR CORRODE PANS. DO NOT USE STEEL WOOL OR ABRASIVE
PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE ALL
RESIDUES. FAILURE TO MEET THESE CONDITIONS WILL VOID WARRANTY.