VGG7
Protected by US Patent #D610,376
Self-Service Protector w/ Top Shelf
& Hatco GRAH Foodwarmer
FINISH:
Clear Anodized Aluminum
Powder Coat:
Black Silver
RAL#
GLASS (Clear Tempered):
3/8" Front - Std 1/2" Front
3/8" Top - Std
1/2" Top
Frosted
Anti - Reflective
Starfire
LENGTHS:
-2 = 35-1/4" O.A. - 1 Section
-3 = 49" O.A. - 1 Section
-4 = 62-3/4" O.A. - 2 Sections
-5 = 76-1/2" O.A. - 2 Sections
-6 = 90-1/4" O.A. - 2 Sections
Custom = ___________ O.A.
NSF/ANSI2 -2010 Standards Requirements:
This language is copied with permission of NSF International
5.35.7
5.35.7.1
5.35.7.2
5.35.7.3
5.35.7.5
5.35.7.10
5.35.6
5.35.6.1
Self service food shields
Maximum vertical distance between counter top and bottom leading edge of shield shall be 13 inches
Minimum horizontal distance between the front inside edge of food and bottom leading edge of shield shall
be 3/4 of the Max. vertical distance of 5.35.7.1 (.75 x 13” = 9.75”)
The sum of a shield’s projected vertical plane (Y) and projected horizontal plane (X) shall be greater than or
equal to 20 inches. Either (X) or (Y) may equal 0
Maximum horizontal distance between vertical, horizontal, and angled panels at post and framing member
locations shell be 2 inches
Food shields for use on mobile buffet counters shall conform to 5.35.7
A vertical barrier (end shield) shall be provided at each end of a foodshield. The vertical barrier shall be
a minimum of 18 inches deep (front to back) beginning at the bottom leading edge of the foodshield.
The minimum height of the vertical barrier shall be equal to the overall height of the foodshield.
The maximum distance from the bottom edge of the vertical barrier and counter top shall be 1.5 inches.
A foodshield intended to be installed a maximum of 3" (76m m) from a building wall perpendicular to the
foodshield is exempt from the requirements of 5.35.6 provided that the height of the building wall is not
lower than the overall height of the foodshield.
T1
®
- Centerline Dimensions L / L1 - 60" Max (3/8" Glass)
- 66" Max (1/2" Glass)
T1 - 96" Max in Single Section
(*) Not all option available on all models
Contact Factory for specific information
For Mounting Options see Mounting
Specifications Sheet
PROTECTORS WITH LIGHTS AND/OR
WARMERS REQUIRE (2) END PANELS
(2) End Panels per unit unless
otherwise specified. End panels
are 1/4" clear tempered glass
unless otherwise specified.
20 7/8
11 3/4
13
L
L1*
L2
3 7/8
14 3/4
17 15/16
13
( * - Middle support is centered unless L1 dimension is specified )
10/22/10