Atlas Metal VGG7-LT-2 Specifications

VGG7
Protected by US Patent #D610,376
Self-Service Protector w/ Top Shelf
& Slimline T8 Fluorescent Lamp
FINISH:
Clear Anodized Aluminum
Powder Coat:
Black Silver
RAL#
GLASS (Clear Tempered):
3/8" Front - Std 1/2" Front
3/8" Top - Std
1/2" Top
Frosted
Anti - Reflective
Starfire
LENGTHS:
-2 = 35-1/4" O.A. - 1 Section
-3 = 49" O.A. - 1 Section
-4 = 62-3/4" O.A. - 1 Section**
-5 = 76-1/2" O.A. - 2 Sections
-6 = 90-1/4" O.A. - 2 Sections Custom = ___________ O.A.
NSF/ANSI2 -2010 Standards Requirements:
This language is copied with permission of NSF International
5.35.7
5.35.7.1
5.35.7.2
5.35.7.3
5.35.7.10
5.35.6
5.35.6.1
Self service food shields
Maximum vertical distance between counter top and bottom leading edge of shield shall be 13 inches Minimum horizontal distance between the front inside edge of food and bottom leading edge of shield shall be 3/4 of the Max. vertical distance of 5.35.7.1 (.75 x 13” = 9.75”) The sum of a shield’s projected vertical plane (Y) and projected horizontal plane (X) shall be greater than or equal to 20 inches. Either (X) or (Y) may equal 0 Maximum horizontal distance between vertical, horizontal, and angled panels at post and framing m ember locations shell be 2 inches Food shields for use on mobile buffet counters shall conform to 5.35.7
A vertical barrier (end shield) shall be provided at each end of a foodshield. The vertical barrier shall be a minimum of 18 inches deep (front to back) beginning at the bottom leading edge of the foodshield. The minimum height of the vertical barr ier shall be equal to the overall height of the foodshield. The maximum distance from the bottom edge of the vertical barrier and counter top shall be 1.5 inches. A foodshield intended to be installed a maximum of 3" (76mm) from a building wall perpendicular to the foodshield is exempt from the requirements of 5.35.6 provided that the height of the building wall is not lower than the overall height of the foodshield.
T1
®
- Centerline Dimensions ­L / L1 - 60" Max (3/8" Glass)
- 66" Max (1/2" Glass) T1 - 96" Max in Single Section
(*) Not all option available on all models Contact Factory for specific information For Mounting Options see Mounting Specifications Sheet
PROTECTORS WITH LIGHTS AND/OR WARMERS REQUIRE (2) END PANELS
(2) End Panels per unit unless otherwise specified. End panels are 1/4" clear tempered glass unless otherwise specified.
19 1/8
16 5/8
8 1/2
13
L
L1*
L2
3 7/8
17 15/16
11 1/4
( * - Middle support is centered unless L1 dimension is specified )
( ** - 1/2" Clear Tempered Glass Top Panel )
10/22/10