Atlas Metal VGG7 User Manual

Self service food shields
5.35.7.1
5.35.7.2
5.35.7.3
equal to 20 inches. Either (X) or (Y) may equal 0
5.35.7.5
5.35.7.10
5.35.6
A vertical barrier (end shield) shall be provided at each end of a foodshield. The vertical barrier shall be
a minimum of 18 inches deep (front to back) beginning at the bottom leading edge of the foodshield.
The minimum height of the vertical barrier shall be equal to the overall height of the foodshield.
The maximum distance from the bottom edge of the vertical barrier and counter top shall be 1.5 inches.
5.35.6.1
A foodshield intended to be installed a maximum of 3" (76mm) from a building wall perpendicular to the
foodshield is exempt from the requirements of 5.35.6 provided that the height of the building wall is not
VGG7
Protected by US Patent #D610,376
Self-Service Protector w/ Top Shelf
& Hatco GRAHL Foodwarmer
w/ Lights
FINISH:
Clear Anodized Aluminum
Powder Coat:
Black Silver
RAL#
GLASS (Clear Tempered):
3/8" Front - Std 1/2" Front
3/8" Top - Std
1/2" Top
Frosted
LENGTHS:
-2 = 35-1/4" O.A. - 1 Section
-3 = 49" O.A. - 1 Section
-4 = 62-3/4" O.A. - 2 Sections
-5 = 76-1/2" O.A. - 2 Sections
-6 = 90-1/4" O.A. - 2 Sections Custom = ___________ O.A.
NSF/ANSI 2 - 2010 Standards Requirements:
This language is copied with permission of NSF International
5.35.7
Maximum vertical distance between counter top and bottom leading edge of shield shall be 13 inches Minimum horizontal distance between the front inside edge of food and bottom leading edge of shield shall
The sum of a shield’s projected vertical plane (Y) and projected horizontal plane (X) shall be greater than or
Maximum horizontal distance between vertical, horizontal, and angled panels at post and framing member locations shell be 2 inches Food shields for use on mobile buffet counters shall conform to 5.35.7
(*) Not all options available on all models. Contact Factory for specific information. For Mounting Options, see Mounting Specification Sheet
PROTECTORS WITH LIGHTS AND/OR WARMERS REQUIRE (2) END PANELS
lower than the overall height of the foodshield.
T1
L
L1*
L2
( * - Middle support is centered unless L1 dimension is specified )
- Centerline Dimensions ­L / L1 - 60" Max (3/8" Glass)
- 66" Max (1/2" Glass) T1 - 96" Max in Single Section
03/11/2011
3 13/16
(2) End Panels per unit unless otherwise specified. End panels are 1/4" clear tempered glass unless otherwise specified.
20 7/8
13
14 3/4
11 3/4
17 15/16
13
Loading...