Atlas Metal VGG5F User Manual

Self service food shields
5.35.7.1
Maximum vertical distance between counter top and bottom leading edge of shield shall be 13 inches
5.35.7.2
5.35.7.3
The sum of a shield’s projected vertical plane (Y) and projected horizontal plane (X) shall be greater than or
5.35.7.5
locations shell be 2 inches
5.35.7.10
Food shields for use on mobile buffet counters shall conform to 5.35.7
5.35.6
a minimum of 18 inches deep (front to back) beginning at the bottom leading edge of the foodshield.
The minimum height of the vertical barrier shall be equal to the overall height of the foodshield.
5.35.6.1
A foodshield intended to be installed a maximum of 3" (76mm) from a building wall perpendicular to the
foodshield is exempt from the requirements of 5.35.6 provided that the height of the building wall is not
lower than the overall height of the foodshield.
VGG5F
Protected by US Patent #D610,374
Single Sided
Self-Service Protector
FINISH:
Clear Anodized Aluminum
Powder Coat:
Black Silver
RAL#
LENGTHS:
-2 = 35-1/4" O.A. - 1 Section
-3 = 49" O.A. - 1 Section
-4 = 62-3/4" O.A. - 2 Sections
-5 = 76-1/2" O.A. - 2 Sections
-6 = 90-1/4" O.A. - 2 Sections Custom = ___________ O.A.
GLASS (Clear Tempered):
3/8" Top - Std
1/2" Top
Frosted
OPTIONS (*):
End Panel - LT
End Panel - RT
(*) Not all options available on all models. Contact Factory for specific information. For Mounting Options, see Mounting Specification Sheet
NOTE:
VGG5F - FL6.5-A IS ONLY
MOUNTING FLANGE AVAILABLE
NSF/ANSI 2 - 2010 Standards Requirements:
This language is copied with permission of NSF International
5.35.7
Minimum horizontal distance between the front inside edge of food and bottom leading edge of shield shall be 3/4 of the Max. vertical distance of 5.35.7.1 (.75 x 13” = 9.75”)
equal to 20 inches. Either (X) or (Y) may equal 0 Maximum horizontal distance between vertical, horizontal, and angled panels at post and framing member
A vertical barrier (end shield) shall be provided at each end of a foodshield. The vertical barrier shall be
The maximum distance from the bottom edge of the vertical barrier and counter top shall be 1.5 inches.
T1
L L1*
L2
( * - Middle support is centered unless L1 dimension is specified )
- Centerline Dimensions ­L / L1 - 60" Max (3/8" Glass)
- 66" Max (1/2" Glass) T1 - 96" Max in Single Section
01/31/2013
13
6 7/16
(2) End Panels per unit unless otherwise specified. End panels are 1/4" clear tempered glass unless otherwise specified.
20
13 3/8
1
10 9/16
Loading...