Self service food shields
be 3/4 of the Max. vertical distance of 5.35.7.1 (.75 x 13” = 9.75”)
locations shell be 2 inches
Food shields for use on mobile buffet counters shall conform to 5.35.7
A vertical barrier (end shield) shall be provided at each end of a foodshield. The vertical barrier shall be
a minimum of 18 inches deep (front to back) beginning at the bottom leading edge of the foodshield.
The minimum height of the vertical barrier shall be equal to the overall height of the foodshield.
The maximum distance from the bottom edge of the vertical barrier and counter top shall be 1.5 inches.
A foodshield intended to be installed a maximum of 3" (76mm) from a building wall perpendicular to the
VGG15
Protected by US Patent 6,485,118 and US Patent D613,971
Other Patents Pending
Adjustable Self-Service Protector
FINISH:
Clear Anodized Aluminum
Powder Coat:
GLASS (Clear Tempered):
1/4" Front - Std
Frosted
Black Silver
RAL#
LENGTHS:
-2 = 35-1/4" O.A. - 1 Section
-3 = 49" O.A. - 1 Section
-4 = 62-3/4" O.A. - 2 Sections
-5 = 76-1/2" O.A. - 2 Sections
-6 = 90-1/4" O.A. - 2 Sections
Custom = ___________ O.A.
NSF/ANSI 2 - 2010 Standards Requirements:
This language is copied with permission of NSF International
5.35.7
Maximum vertical distance between counter top and bottom leading edge of shield shall be 13 inches
Minimum horizontal distance between the front inside edge of food and bottom leading edge of shield shall
The sum of a shield’s projected vertical plane (Y) and projected horizontal plane (X) shall be greater than or
equal to 20 inches. Either (X) or (Y) may equal 0
Maximum horizontal distance between vertical, horizontal, and angled panels at post and framing member
OPTIONS (*):
End Panel - LT
End Panel - RT
(*) Not all options available on all models.
Contact Factory for specific information.
For Mounting Options, see Mounting
Specification Sheet
foodshield is exempt from the requirements of 5.35.6 provided that the height of the building wall is not
lower than the overall height of the foodshield.
L L1*
L2
( * - Middle support is centered unless L1 dimension is specified )
- Centerline Dimensions L / L1 - 48" Max (1/4" Glass)
03/19/2011
7 9/16
13
5 1/4
9 13/16
(2) End Panels per unit unless
otherwise specified. End panels
are 1/4" clear tempered glass
unless otherwise specified.
20 3/16
13 1/2
20 9/16
1
q
q
VGG15
POSITION #1
20 9/16
3 3/4
13 1/2
7 9/16
13
POSITION #2
21 7/16
3 3/16
11 3/4
GLASS POSITIONS
POSITION #3
10
10
22 1/16
11 7/16
2 3/8
Protected by US Patent 6,485,118 and US Patent D613,971
Adjustable Self-Service Protector
POSITION #5POSITION #4
11 3/4
10 1/4
2 7/8
16 3/4
1 3/4
15
19 9/16
14 1/2
5 1/4
14 5/16
4 1/8
20 9/16
END PANEL OPTIONS
FIXED OPEN FULL FIXED OPEN NOTCHED
20 3/16
13 13
1
FIXED FULL SINGLE
END PANEL
3 3/4
"X" = DISTANCE FROM FRONT
OF FLANGE TO CUT BACK POINT
"X"
3 3/4
FIXED NOTCHED
SINGLE END PANEL
ON END PANEL
Versa-Gard,LLC - 1094 Parkway Industrial Park Drive, Buford, GA 30518
Copyright 2011