VGG1
Protected by US Patent #D610,373
Sloped-Service Protector
FINISH:
Clear Anodized Aluminum
Powder Coat:
Black Silver
RAL#
LENGTHS:
-2 = 35-1/4" O.A. - 1 Section
-3 = 49" O.A. - 1 Section
-4 = 62-3/4" O.A. - 2 Sections
-5 = 76-1/2" O.A. - 2 Sections
-6 = 90-1/4" O.A. - 2 Sections
Custom = ___________ O.A.
NOTE:
VGG1 ONLY - FL6.5-A IS ONLY
MOUNTING FLANGE AVAILABLE
GLASS (Clear Tempered):
3/8" Front - Std
Frosted
Anti - Reflective
Starfire
®
OPTIONS (*):
End Panel - LT
End Panel - RT
(*) Not all option available on all models
Contact Factory for specific information
For Mounting Options see Mounting
Specifications Sheet
NSF/ANSI2 -2010 Standards Requirements:
This language is copied with permission of NSF International
5.35.11
Food Shields for use on cooking and/or carving station operations
Shields for use on a cooking and/or c arving station shall include a vertical barrier to a minimum height of 60
5.35.11.1
inches above the finished floor.
Maximum vertical distance from the bottom edge of the shield and counter top shall be 6 inches
5.35.11.2
Minimum horizontal distance between the f ront inside edge of displayed food and front (customer side) face
5.35.11.3
of shield shall be 3/4 of the vertical dis tance (.75 x 6" = 4") of 5.35.11.2
5.35.12
Food Shields for use on cafeteria counters
The sum of a shield’s pro tected horizontal plane (X) and its protected vertical plane (Y) shall be greater than
5.35.12.1
or equal to 32 inches. When (X ) = 0, (Y) shall be a minimum of 60 inches from finis hed floor
Maximum distance from the bottom edge of the front vertical glass and counter top shall be 1.5 inche s
5.35.12.2
Maximum distance between the ver tical glass and horizontal glass is 3/4 inch
5.35.12.3
Minimum horizontal distance between the f ront inside edge of displayed food and the bottom leading edge of
5.35.12.4
the shield s 1.5 inches
A vertical barrier (end shield) s hall be provided at each end of a foodshield. The vertical barrier shall be a
5.35.6
minimum of 18 inches deep (front to back) beginning at the bottom leading edge of the foodshield.
The minimum height of the vertical barrier shall be equal to the overall height of the foodshield.
The maximum distan ce from the bottom edge of the vertical barrier and counter top shall b e 1.5 inches.
A foodshield intended to be installed a max imum of 3" (76mm) from a building wall perpendicula r to the
5.35.6.1
foodshield is exempt from the requirements of 5.35.6 provided that the height of the building wall is not
lower than the overall height of the foodshield.
T1
L
L1*
L2
( * - Middle support is centered unless L1 dimension is specified )
- Centerline Dimensions L / L1 - 60" Max (3/8" Glass)
T1 - 96" Max in Single Section
(2) End Panels per unit unless
otherwise specified. End panels
are 1/4" clear tempered glass
unless otherwise specified.
24 5/16
26 1/4
80°
17 1/4
20 9/16
10/22/10