Atlas Metal VGG1-2, VGG1 User Manual

VGG1
Protected by US Patent #D610,373
Sloped-Service Protector
FINISH:
Clear Anodized Aluminum
Powder Coat:
Black Silver
RAL#
LENGTHS:
-2 = 35-1/4" O.A. - 1 Section
-3 = 49" O.A. - 1 Section
-4 = 62-3/4" O.A. - 2 Sections
-5 = 76-1/2" O.A. - 2 Sections
-6 = 90-1/4" O.A. - 2 Sections Custom = ___________ O.A.
NOTE: VGG1 ONLY - FL6.5-A IS ONLY MOUNTING FLANGE AVAILABLE
GLASS (Clear Tempered):
3/8" Front - Std
Frosted
Anti - Reflective
Starfire
®
OPTIONS (*):
End Panel - LT
End Panel - RT
(*) Not all option available on all models Contact Factory for specific information For Mounting Options see Mounting Specifications Sheet
NSF/ANSI2 -2010 Standards Requirements:
This language is copied with permission of NSF International
5.35.11
Food Shields for use on cooking and/or carving station operations
Shields for use on a cooking and/or c arving station shall include a vertical barrier to a minimum height of 60
5.35.11.1
inches above the finished floor. Maximum vertical distance from the bottom edge of the shield and counter top shall be 6 inches
5.35.11.2
Minimum horizontal distance between the f ront inside edge of displayed food and front (customer side) face
5.35.11.3
of shield shall be 3/4 of the vertical dis tance (.75 x 6" = 4") of 5.35.11.2
5.35.12
The sum of a shield’s pro tected horizontal plane (X) and its protected vertical plane (Y) shall be greater than
5.35.12.1
or equal to 32 inches. When (X ) = 0, (Y) shall be a minimum of 60 inches from finis hed floor Maximum distance from the bottom edge of the front vertical glass and counter top shall be 1.5 inche s
5.35.12.2
Maximum distance between the ver tical glass and horizontal glass is 3/4 inch
5.35.12.3
Minimum horizontal distance between the f ront inside edge of displayed food and the bottom leading edge of
5.35.12.4
the shield s 1.5 inches
A vertical barrier (end shield) s hall be provided at each end of a foodshield. The vertical barrier shall be a
5.35.6
minimum of 18 inches deep (front to back) beginning at the bottom leading edge of the foodshield. The minimum height of the vertical barrier shall be equal to the overall height of the foodshield. The maximum distan ce from the bottom edge of the vertical barrier and counter top shall b e 1.5 inches. A foodshield intended to be installed a max imum of 3" (76mm) from a building wall perpendicula r to the
5.35.6.1
foodshield is exempt from the requirements of 5.35.6 provided that the height of the building wall is not lower than the overall height of the foodshield.
T1
L
L1*
L2
( * - Middle support is centered unless L1 dimension is specified )
- Centerline Dimensions ­L / L1 - 60" Max (3/8" Glass) T1 - 96" Max in Single Section
(2) End Panels per unit unless otherwise specified. End panels are 1/4" clear tempered glass unless otherwise specified.
24 5/16
26 1/4
80°
17 1/4
20 9/16
10/22/10