Atlas Metal CATR PARTS LIST

Subsidiary of Mercury Aircraft, Inc.
1135 N.W. 159th DR., MIAMI, FL 33169
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: sales@atlasfoodserv.com
PARTS LIST REFRIGERATED BASE
RB-4, RB-5 SERIES
ITEM
2 S90253-4 Door Assembly RB-4 & RB-5 3 S83951-0 Door Assembly RB-5
4 5 6053-8 Hinge & Cover 6 7 113-5 Thermometer
8 2060-1 Condensate Water Evap. (Not Shown) 9 1002-0 Power Cord (Not Shown) 10 2006-4 1/4 H.P. Compressor (Not Shown)
11 2119-0
12 22-1406 Thermostat (Not Shown) 13 2013-0 Fan Motor (Not Shown) 14 2014-5 Fan Blade (Not Shown) 15 S81441-0 Fan Guard (Not Shown) 16 S81419-0 Fan Bracket (Not Shown) 17 1149-0 Wire Harness (Not Shown) 18 S83952-0 Tray Rack (Not Shown) 19 2026-0 0.042 Cap Tube (Not Shown) 20 2025-0 Drier (Not Shown)
PART
97-105 RB-4 & RB-5 Large Door Gasket 97-107 RB-5 Small Door Gasket
6055-1 Slam Action Latch 6052-1 Slam Action Latch W/Lock
S84051-0 RB-4 Grill S84050-0 RB-5 Grill
DESCRIPTION
Evaporator Coil RB-5 (Not Shown) Evaporator Coil RB-4 (Not Shown)
RB-5 SHOW N
SLIDE- IN REFRIGERATED BASE
RB SERIES
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
MODEL
RB-4
RB-5
CAPACITY 12 “ X 20” PANS
STORAGE
10 Pans- 1 Door
8 cu. ft.
15 Pans- 2 Doors
10 cu. ft.
OPERATION
The unit is ready to operate as soon as it is plugged in and turned on. The thermostat has an off position and numbers from #1 through #7 (number 7 is the coldest). The unit has been pre-tested and set for proper operation with the thermostat set for 35˚ to 40˚. Do not block air discharge openings inside the base of the unit. A timer is installed in the system to shut the compressor off every 4 hours (approximately 15 minutes) to eliminate ice build up on the evaporator coil. The unit is supplied with a power cord and NEMA plug. Refer to the data plate located in the compressor compartment for the amperage and voltage information. Use a licensed electrician when installing power source. Note: Proper ventilation must be provided in counter.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
CUT-OUT
REQUIRED
23 1/2" X 55 1/2"
23 1/2" X 69 1/4"
MAINTENANCE
NEVER CLEAN THE UNIT WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER CLEANING COULD SCAR, MARK AND/OR CORRODE METAL. DO NOT USE STEEL WOOL OR ABRASIVE PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE ALL RESIDUES.CLEAN CONDENSER COIL REGULARLY. FAILURE TO MEET THESE
CONDITIONS WILL VOID WARRANTY.