GENERAL INFORMATION
The BMM-1OOO series Self Serving Milk Units are equipped with refrigerated compartment to hold (12) 13" x 13" x 11" milk cases.
Examine the interior of the unit and make sure all packing materials, such as wood and cardboard removed before unit is plugged in to an outlet. Examine the exterior and interior of the unit to determine whether any damage was incurred during delivery. If so, notify the carrier or your dealer immediately to file a damage claim. All ATLAS equipment is carefully tested and inspected prior to shipment. When accepted for delivery by the carrier, the responsibility for safe arrival is assumed by the carrier.
INSTALLING:
These units have been carefully designed to meet your required operational needs: Prior to operating these units, it is important to check the following:
1. Supply cord and plug for possible damage due to shipping. (Loose wires, fraying, or cuts in cord.)
2. Temperature controls must not have any “play or movement with exception of control knob.”
3. Plug in to proper electrical receptacle as indicated on the rating plate of each unit .
WARNING: SHOULD ANY DAMAGE BE FOUND AFTER GOING THROUGH THE ABOVE CHECK LIST, DO NOT ATTEMPT TO OPERATE UNIT. CALL YOUR DEALER IMMEDIATELY TO ARRANGE FOR FACTORY AUTHORIZED SERVICE.
OPERATING:
For equipment containing refrigeration units, allow adequate time after 'turn-on" for units to reach proper temperature. Time varies depending on ambient temperature and locations. The unit will maintain proper temperature, cycling on its pressure control, so field adjustment should not be necessary.
MAINTENANCE:
This equipment has been designed to require minimum maintenance and has been constructed to meet National Sanitation Foundation, Underwriters Laboratory Standards, and U.S. Public Health Service Standards. Non-toxic chemical cleaners or mild detergents are recommended for cleaning of fixtures. Do NOT use steel wools at any kind. Steel wool particles will work in to the grains of the metal causing corrosion. Also, these particles can cause a health hazard. Should scouring be required, use a non-abrasive type of cleaner. Do not use caustic solutions on your equipment. Hosing or steam cleaning should not be necessary to keep these fixtures clean and sanitary. Do not allow water or steam to come In contact with electrical components.
WARNING: Be sure to disconnect power source before cleaning or servicing the unit. Liability for improper or careless use is the responsibility at the equipment owner or persons servicing the unit, including authorized service agents.
PARTS LIST
ITEM NO.
1
2
3
4
5
6
7
8
9
10
11
12
DESCRIPTION PART NO.
CONDENSING UNIT 2004-1
5” CASTER W/O BRAKE 1800-497
5” CASTER W/BRAKE 1800-499
LATCH, SASH. CHROME 1800-3870
SWITCH MAIN ON/OFF 1800-3955
COVER PLATE SWITCH 1800-4054
THERMOMETER CLIP-ON 4913-4
BOTTOM, FALSE P40225-000
LOCK, FRONT DOOR P41593-000
HINGE, LEFT LID P42293-000
HINGE, RIGHT LID P42294-000
HINGE, CENTER P42295-000
13
14
LATCH, DOOR LOCK P42760-000
BRACKET, TRAY SLIDE 70045-8
13
8
14
2
3
Loading...
+ 4 hidden pages