Protected) or by Front Panel Pots with Tamper Deterring Covers
• Four (4) GPIO Control Ports Assignable in GUI for Mute or Remote
Level
Applications
The flexible DSP, remote web monitoring, and control of the DPA Series
amplifiers makes them the perfect choice for presentation rooms,
classrooms, conference rooms, and retail background / foreground music
applications.
General Description
The AtlasIED DPA Series amplifiers feature a combination of flexibility,
performance, and control to provide high value features for applications
that require more than just great sound. The network enabled DPA
series amplifiers are DSP controlled four-channel amplifiers that can be
configured in three different amplification arrangements to meet a wide
range of installation design requirements.
DPA amplifiers can be used right out of the box in their factory default
configuration as traditional four-channel 70.7V commercial power
amplifiers requiring no programming, special set-up, or network
connectivity. However, when web enabled, the DPA amplifiers can be
configured in four-channel mode with either 4Ω or 8Ω load impedances
for two stereo zones. Many system designs require both low and
high impedance amplification. The DPA series can be configured for a
70.7V/100V paging/background system on two channels and the other
two channels can be used for 4Ω/8Ω foreground stereo applications.
The DPA comes standard with four balanced line inputs and an
accessory slot for an optional DPA-DAC4 four-channel Dante™ receiver
card or a DPA-AMIX (2) mic/line and (2) AUX input card, for a total of
eight inputs. All inputs can be mixed and routed to any of the four
amplifier channels. All amplifier channels have an assortment of DSP
tools including level controls, EQs, limiters, high & low pass filters, and
delay to provide flexibility for a range of applications.
The output level can be assigned to either the front panel
potentiometers or to the onboard GUI. Wired remote level controls
can be configured to allow simple control for the end user. Each
unit also features GUI based input and output level metering along
with assignable mute functions that are triggered via an audio signal
or contact closure. Access to the DSP settings is accomplished via
computer, tablet, or mobile device using a web browser. All settings can
be password protected.
The DPA series amplifiers also include PC based site manager software
that automatically searches within a specific network for all DPA
amplifiers on the network. It will list them and allow single click access
to any unit. The DPA Site Manager software can do a variety of functions
besides locating IP addresses such as; fault reporting, input & output
status, standby status and remote activation via a scheduler timer.
The flexibility of the DPA Series amplifiers and comprehensive
assortment of local or network control configurations make them an
ideal choice in today's sophisticated commercial audio market.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005591 RevA 3/17
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
AtlasIED.com
Page 2
System
Type800-Watt 4-Channel Configurable Network Digital Commercial Power Amplifier
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005591 RevA 3/17
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
AtlasIED.com
Page 3
Status Indicators
PowerBlue Indicator
Standby (Remote Turn ON)Blinking Blue Indicator, Front Panel Only
Output SignalGreen
LED Bar MeterGUI Only
Output Limit / ProtectRed
4/8 Ohm Yellow, CH 1/2 & CH 3/4
70V / 100V OperationYellow, CH 1/2 & CH 3/4
Output Mute StatusFlashing Red
DSP Elements
I/O RoutingMatrix Mixer
Hi & Low Pass FiltersOne per Output, Adjustable Slopes and Frequencies
EQ5 Parametric Filters per Output
Delay60mS per Output
LimiterEach Output up to 12dB of Assignable Limiting
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005591 RevA 3/17
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
AtlasIED.com
Page 4
AC Power Requirements
Operating Voltage110V - 120V & 220V - 230V 50/60Hz, Auto Sense
Mains InterfaceIEC 15A Receptical
Power Cord (Included)1.5m, IEC C13 to NEMA 5-15P Plug, 18AWG
Minimum Power-Up Voltage90V
Maximum Operating Voltage264V
Recommended AC Mains Current Requirements5.3A (Speech & Back Ground Music), 15A (Max Usage)
Power Consumption and Current Draw (Note 5)AmpsWattsBTU
Sleep Mode90mA 4W12 BTU
Standby / APD Mode (Note 2)225mA 18W56 BTU
Idle Active Mode (Note 2)650mA 40W126 BTU
Average Power 4Ω, All Channels Driven (Note 3)3.7A 270W964 BTU
Average Power 70V, All Channels Driven (Note 3)5.3A 425W1280 BTU
Max Power 4Ω, All Channels Driven (Note 4)9.5A 794W2369 BTU
Max Power 70V, All Channels Driven (Note 4)15.9A 1362W3692 BTU
Dimensions and Weight
Rack Mount Requirements1 RU, 19"
Dimensions - UnitW 19" x H 1.72" x D 15.5" (483mm x 45mm x 394mm)
Dimensions - ShippingW 24.5" x H 3.5" x D 18.7" (635mm x 89mm x 477mm)
Weight - Unit13 lbs. (5.92kg)
Weight - Shipping17.4 lbs (7.94kg)
Agency Approvals
North America AgencyTUV
Testing Standard North America60065
FCC Class A (Conducted & Radiated Emissions)Part 15 of the FCC Rules
RoHS / WEEE CompliantYes
CEYe s
Optional Accessories
DPA Site ManagerSoftware
AA-YSUMStereo Signal Passive Summing Cable
WPD-VC10KPotentiometer on Wall Plater for Remote Level Control
DPA-DAC44 CH Dante™ Receiver
DPA-AMIX Analog 4 CH Mic / Line / AUX Input Card
4/7
NOTES:
1. Power level measurment is define as follows: 1Hz Sine wave signal burst of 20 cycles (20mS) at 1% THD+N, followed by 480 cycles of a 1kHz sine wave at 10% of the
max power. Other power measurements are available upon requests.
2. Power measurement with Ethernet connected. Without Ethernet connected deduct .2W
3. Average Power is defined as Pink Noise input signal applied to achieve 1/4 of the 4 Ohm or 70.7V power rating.
4. Max Power is defined as 1 KHz input signal applied to achieve the maxium power output before clipping into a 4 Ohm or 70.7V load.
5. BTU is calcualed by the AC Mains Power consumed minus the total power output measured at the specified load and condition, multiplied by 3.412.
Example: 785 Watts from the AC Source - 600 Watts Total Output power = 185 x 3.412 = 631 BTU
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005591 RevA 3/17
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
AtlasIED.com
Page 5
Dimensional Drawings
19.00
1.72
0
0
15.5
19.00
FRONT
SIDE
0
DPA804
Digital Power Amplifier
1
Signal
Level
Channel
Limit/
Protect
4/8Ω
70/100V
234
Ch. 1/23/4
010010010010
Operating Mode
1
Channel
Signal
Limit/
Protect
Level
0 10 0 10 0 10 0 10
2 3 4
Operating Mode
Ch. 1/2 3/4
5/7
4/8Ω
70/100V
DPA804
Digital Power Amplifier
14.5
OUTPUT CHANNEL CONFIGURATIONS - SET IN GUI
Note: Factory Default Out of Box Configuration is 4 Channel 70V/100V Mode
Factory Default
4 CHANNEL 70V/100V CONFIGURATION
OUTPUTS
1+ 1- 2+ 2- 3+ 3- 4+ 4-
CH 1 CH 2 CH 3 CH 4
-
+-+-+-+
70V/100V
SPEAKERS
For Unbalanced
Line Tie Low to G
G
G
Input (1)Input (4)(2) (3)
CONTROL PORT SETTINGS FOR REMOTE LEVELLogging on to the DPA GUI Page
REMOTE LEVEL CONTROL ON CHANNEL 1, 2, 3 & 4
WPD-VC10K
WPD-VC10K
G
+
+
+
-
-
-
CH 1 CH 2CH 3 CH 4
INPUTS
(FACTORY DEFAULT)
+10V C2
C4
C1
C3 GND
P1
P2
P3
Remote
Remote
Remote
Level #2
Level #3
Level #4
10VDC
P1
10K Ohm
P3
LINEAR
RETURN
TAPER
P2
GND
DPA CONFIGURED IN 4 CHANNEL 4 or 8 Ohm MODEDPA SPLIT CONFIGURATION EXAMPLE
G
-
Note: Factory Default
The Control Ports are set
as follows: C1, C2, C3, and
C4, control CH1, CH2, CH3,
and CH4 respectively.
4 Individual 10K Linear Pots
can be used or, a single Pot
can be used as a Master.
Input (1)Input (4)(2) (3)
+
SET IN GUI
OUTPUTSOUTPUTS
1+ 1- 2+ 2- 3+ 3- 4+ 4-
CH 1 CH 2 CH 3 CH 4
+
G
-
4 or 8 Ohm
SPEAKERS
+
INPUTS
-
G
G
+
+
-
-
+-+-+-+
G
-
CH 1 CH 2CH 3 CH 4
DPA Discovery Software
• Visit AtlasIED.com/SoftwareLibrary and download the “DPA Amplifier
Discovery Software” and the Installation Guide. Follow the guide.
Manual Method
• The DPA is shipped with IP set to DHCP
• Connect the DPA to the router, and the computer to the same router or LAN
• Open a web browser (Google Chrome or Mozilla Firefox)
• In the address bar type: http://dpa404 (or DPA model being used) and press Enter
• The DPA GUI web page will launch
• Use Network Settings to configure the DPA
• Once the IP address is obtained, enter the IP address in the address bar
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005591 RevA 3/17
1601 Jack McKay Blvd. • Ennis, TX 75119
800.876.3333 • AtlasIED.com
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE
AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE
AtlasIED Digital IP Configuration
To Reset IP Configuration to Factory Default Settings:
• Disconnect the Power From the Device
• Wait 60 Seconds
• Connect Power To the Device
• Press and Hold Front Panel Power Switch Until LED Blinks 5 Times Quickly
• IP Configuration is Reset to Factory Default Settings
• Factory Settings DHCP Enabled
• For Direct Connection to Amp: Refer to Installation Guide
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
17.00
For Optimum Performance AtlasIED Recommends:
FAP Series In-Ceiling Speakers
SM Series Surface Mount Speakers
AP Series Paging Horns
Atlas Power Sequencers and Conditioners
500 Series Equipment Racks
LAR150 Rack Loading Tool
Note: Amplifier Output Load Configuration Is Set VIA DSP GUI
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
Note: Out of the Box, the DPA Amplifier
is Configured in 70 Volt Mode.
CAUTION: For continued protection
against risk of fire, replace only with
same type fuse and rating.
ATTENTION: Utiliser un fusible de
rechange de meme type et calibre.
FUSE RATING: T8A L 250VAC
120/220-240V~50/60Hz 8A
AtlasIED.com
Page 6
Optional Accessories
WPD-VC10K
WPD-VC10K
DPA-DAC4 - Dante™ Four-Channel Receiver Card
DPA-AMIX - Four-Channel Mic / Line AUX Mixer Amp Card
6/7
WPD-VC10K: Potentiometer on Wall Plater for Remote Level Control
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005591 RevA 3/17
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
AtlasIED.com
Page 7
Architect and Engineer Specications
7/7
The power amplifier shall be a four-channel switch mode power amplifier
with efficient BASH Hybrid topology output circuitry. The amplifier shall
be configurable as four-channel high impedance 70V/100V or fourchannel low impedance 4Ω or 8Ω or two-channel low impedance 4Ω
or 8Ω and two-channel high impedance 70V/100V mode. The amplifier
shall be shipped factory preset in four-channel 70V configuration. The I/O
router shall be configured as follows: Input 1 routed to Outputs 1, Input
2 to Output 2, Input 3 to Output 3 and Input 4 to Output 4. This out of
box configuration will not require a computer or network to operate.
The performance specifications shall match or exceed the following:
70V / 100V = 4CH x 200W; 8Ω = 4CH x 150W, 4Ω = 4CH x 100W;
70V / 100V = 2CH x 200W & 8Ω = 2 CH x 150W;
70V / 100V = 2CH x 200W & 4Ω = 4CH x 100W; (reference
specifications Notes 1-4); Input Sensitivity 750mV Balanced, 0dBU;
Input Impedance Balanced 40K Ohms; Max Input Level channels 1-4,
+14dBU, 7dBU inputs 5-8 with Dante™; THD 1% at rated output, .2%
Typical; Frequency Response -3dB 20Hz @ 20kHz (DSP set to flat);
Signal to Noise Ratio -100dB Below Rated Output A Weighted; Crosstalk
>70dB @1kHz; Protection circuits =Thermal, Short, Signal Limiter; Sleep
Mode (Ethernet Active) 3.5W, 12BTU; Standby/ADP mode 14W, 48BTU;
Max Power All CH driven 70.7V/100V (default mode) = 704W, 390BTU.
Dimensions: 1 x RU, 19" W x 1.72" H x 15.5" D. Weight 13.1 lbs.
The power amplifier shall have a front panel power switch and three
states of idle power: Idle Active Mode, Sleep Mode, and Standby Auto
Power Down (APD) Mode. Each mode shall have an LED indicator on
the front panel indicating the power status. When in Sleep Mode, the
Ethernet shall remain active for access to the amplifiers on board GUI.
The amplifier shall include convection cooling with dynamic fan assist
for extreme conditions. If the unit is not being used or in Standby mode,
the fan shall not be needed for cooling and shall remain Off until the unit
is in heavy use. As heat is generated in the amplifier during use, the fan
shall activate at a low speed and increase as needed to maintain the
amplifier at safe operating temperature. The amplifiers air flow shall be
from rear to front.
The front panel controls shall consist of four volume controls that can be
removed and replaced with included security covers. Above each volume
control, LED indicators for Signal and Limit/Protect/Mute shall signal the
amplifier output operating condition. The four-channel output operating
mode shall be displayed to the right of the output indicators by 4
multicolor LEDs. These indicators illustrate if Channels 1 and 2 and 3 and
4 are low impedance 4Ω or 8Ω or 70V/100V output. Amplifier operation
mode settings shall be completed using the internal DSP GUI.
On the rear panel, the amplifier shall have an IEC AC receptacle that
operates from 110V - 120V & 220V - 240V and shall automatically sense
the AC Mains voltage and change voltage settings. A removable AC
Mains fuse shall be provided for protection.
The rear-mounted Input connectors for inputs 1 - 4 shall be individually
removable 3-way 3.5mm Phoenix type connectors that accept balanced
line input signals (+) (–) and (GND) pins and will support unbalanced
signals by connecting the (–) and (GND) pins together. The amplifier
configuration and I/O Routing shall be done in the GUI. Any Input shall
be capable of being routed to any Output.
The rear-mounted Output connector shall be a screw terminal block
type for connecting speakers to the amplifier. The recommended wire
to use shall be Class 3 rated,14-gauge wire or lower for speaker wiring.
Amplifier output channel configurations shall be done in the amplifier
GUI. The amplifier shall be shipped with two speaker output terminal
covers for safety. Included in the carton with the amplifier shall be
eight (8) spade crimp terminals that accept 12-gauge wire and four (4)
security cover screws (M3 x 8mm). Terminal block screws shall be M4.
The amplifier shall be pre-configured at the factory for four-channel
70.7V/100V mode.
The amplifier shall have one (1) rear mounted Accessory Card Slot to add
accessory modules. Accessory modules shall make available 4 additional
inputs (for a total of 8) that can be routed to any of the four output
channels. Optional accessory cards shall include a four-channel Dante™
Digital Audio Input Card and a four-channel Analog Mic/Line, Auxiliary
Input Card.
The amplifier shall have a rear-mounted Ethernet connector to connect
to a Local Area Network (LAN), computer, or router/switch using a
standard RJ45 cable to access the amplifiers DSP and control settings.
When network enabled, the amplifier shall have a GUI home page with
Input and Output active meters, Output Configuration indicators, with
Tab selections to navigate to User PC Control page, Amplifier Setup
page, Mobil Control page, IP Configuration page where I/O can be
labeled, Update page for firmware upload, and About page. All four
amplifier channels shall have an assortment of DSP tools with navigation
icons to the following individual GUI pages: Amplifier Configuration,
Mute, Link & Ports Assign, I/O Router Assign, Hi & Lo Pass Filters,
5-Band Parametric EQ, Output Level, Delay, and Limiter.
The amplifier shall have four (4) rear-mounted Control Ports to allow
assigned/configured Remote Level or Mute functions to be activated
by external contact closure relay or controlled by voltage. Each Control
Port pin shall be assigned to one function such as Mute or Level, but
not both. Control Port assignment shall be done in the GUI Mute, Link,
Port Assignment Page. The factory default assignments for the Amplifier
Control Ports are assign as a Remote Level & shall be as follows:
C1 controls Output 1, C2 controls Output 2, C3 = controls Output 3,
C4 controls Output 4. The Control Ports shall provide +10V and GND
connections for Remote Level Control Port using 10kΩ Linear Taper pots.
The amplifier shall have Site Manager software to perform a variety of
functions including locating DPA amplifiers' IP addresses; fault reporting,
input & output status, standby status, and remote activation via a
scheduler timer.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005591 RevA 3/17
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
AtlasIED.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.